Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Radiol Med ; 127(4): 407-413, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35258775

RESUMO

OBJECTIVES: To evaluate the quality of the reports of loco-regional staging computed tomography (CT) or magnetic resonance imaging (MRI) in head and neck (H&N) cancer. METHODS: Consecutive reports of staging CT and MRI of all H&N cancer cases from 2018 to 2020 were collected. We created lists of quality indicators for tumor (T) for each district and for node (N). We marked these as 0 or 1 in the report calculating a report score (RS) and a maximum sum (MS) of each list. Two radiologists and two otolaryngologists in consensus classified reports as low quality (LQ) if the RS fell in the percentage range 0-59% of MS and as high quality (HQ) if it fell in the range 60-100%, annotating technique and district. We evaluated the distribution of reports in these categories. RESULTS: Two hundred thirty-seven reports (97 CT and 140 MRI) of 95 oral cavity, 52 laryngeal, 47 oropharyngeal, 19 hypo-pharyngeal, 14 parotid, and 10 nasopharyngeal cancers were included. Sixty-six percent of all the reports were LQ for T, 66% out of all the MRI reports, and 65% out of all CT reports were LQ. Eight-five percent of reports were HQ for N, 85% out of all the MRI reports, and 82% out of all CT reports were HQ. Reports of oral cavity, oro-nasopharynx, and parotid were LQ, respectively, in 76%, 73%, 100% and 92 out of cases. CONCLUSION: Reports of staging CT/MRI in H&N cancer were LQ for T description and HQ for N description.


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Hospitais , Humanos , Imageamento por Ressonância Magnética/métodos , Estadiamento de Neoplasias , Glândula Parótida , Tomografia Computadorizada por Raios X/métodos
2.
Eur Radiol Exp ; 7(1): 9, 2023 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-36826698

RESUMO

BACKGROUND: Our purpose was to evaluate the correlations between right ventricular (RV) late gadolinium enhancement (LGE) at cardiac magnetic resonance (CMR) in patients with tetralogy of Fallot (ToF) scheduled for pulmonary valve replacement (PVR) and post-PVR functional data. METHODS: We retrospectively reviewed ToF patients scheduled for PVR who underwent two CMR examinations at our institution, one before the procedure (CMR-0), including contrast-enhanced sequences, and one after the procedure (CMR-1). Functional left and RV data were obtained by segmenting short-axis stacks on both CMR examinations, and normalised variations were calculated by dividing differences between CMR-1 and CMR-0 by the intercurring time interval, whereas the RV scar burden was assessed on CMR-0 LGE sequences both semiquantitatively and quantitatively. Data were reported as median and interquartile range, differences were appraised with the Mann-Whitney U test, while correlations were assessed with Spearman's ρ. RESULTS: Fifteen patients with a median age of 25 years (16-29), including 9 (60%) males, with a median time interval between CMR-0 and CMR-1 of 17 months (12-23), were retrospectively reviewed. The semiquantitative LGE score at CMR-0 was 7 (6-9), and LGE volume was 4.49 mL (3.70-5.78), covering 5.63% (4.92-7.00) of the RV. RV LGE score showed a moderate positive correlation with the normalised variation of RV stroke volume (ρ = 0.662, p = 0.007) and a borderline moderate positive correlation with the normalised variation of RV end-diastolic indexed volume (ρ = 0.513, p = 0.050). CONCLUSIONS: The assessment of RV LGE before PVR may provide insights on post-PVR functional data, potentially facilitating a patient-tailored treatment pathway.


Assuntos
Valva Pulmonar , Tetralogia de Fallot , Masculino , Humanos , Adolescente , Adulto Jovem , Adulto , Feminino , Tetralogia de Fallot/cirurgia , Valva Pulmonar/cirurgia , Meios de Contraste , Gadolínio , Estudos Retrospectivos
3.
Eur J Radiol ; 136: 109521, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33450661

RESUMO

PURPOSE: The aim of this study is to review the literature concerning myocardial late gadolinium enhancement (LGE) with cardiac magnetic resonance in patients with Tetralogy of Fallot (ToF), with regards to its prevalence, characteristics and clinical relevance. METHODS: We performed a systematic search, aiming to retrieve original articles that evaluated LGE in ToF, running a search string on MEDLINE and EMBASE in November 2019 and November 2020. Papers were then selected by two independent, blinded readers based on title and abstract, and then on full-text reading, and articles which did not include LGE evaluation were excluded. From each included paper two readers extracted descriptive data concerning technical parameters of LGE acquisition, LGE description and clinical significance. RESULTS: 18 articles were eventually included in our review. The included studies observed that a higher amount of right ventricular LGE relates with higher right ventricular volumes, lower ejection fraction and a higher pulmonary regurgitant fraction, thus acting as a marker of progressive impairment of myocardial function. Moreover, LGE in ToF patients correlated with the onset of arrhythmias, and with serum biomarkers indicative of myocardial stress and fibrosis. CONCLUSIONS: LGE could be used in the follow-up repaired ToF patients as its appraisal can provide information concerning cardiac dysfunction. Moreover, it may be ideal to aim towards a common framework for standardizing assessment and quantification of LGE in ToF patients.


Assuntos
Gadolínio , Tetralogia de Fallot , Meios de Contraste , Fibrose , Ventrículos do Coração/patologia , Humanos , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Valor Preditivo dos Testes , Tetralogia de Fallot/diagnóstico por imagem
4.
Eur J Radiol ; 131: 109235, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32919263

RESUMO

PURPOSE: To assess right ventricular (RV) myocardial strain both globally and segmentally through feature-tracking cardiac magnetic resonance (CMR) in patients with Tetralogy of Fallot (ToF), with regards to pulmonary valve replacement (PVR). METHODS: After Ethics Committee approval, we retrospectively included 46 consecutive ToF patients who had two CMR examinations performed at our institution between March 2014 and June 2019. We divided patients into those who had not undergone PVR between the two CMR examinations (Group-0), and those who had (Group-1). Ventricular volumes were quantified on cine sequences, and strain was calculated through feature-tracking, using the previously traced segmentations. RV longitudinal and radial strain were assessed both globally and separately for the septum and free wall. Variations were normalized for intercurrent years, differences were appraised with t-tests or Mann-Whitney U. RESULTS: 30 patients belonged to Group-0 and 16 to Group-1. Median age was 22 years (interquartile range [IQR] 17-29 years) in Group-0, and 21 years (IQR 16-29 years) in Group-1. No significant differences were reported in RV strain between groups (p ≥ 0.254) except for RV septal radial strain, significantly higher (p = 0.010) in Group-0 (24.2 %, IQR 10.1-52.4 %) than in Group-1 (6.0 %, IQR -3.3-23.3 %) at the second CMR. Both global and segmental RV strains decreased over time in both groups, and yearly variations did not differ significantly (p ≥ 0.081) between groups. CONCLUSIONS: While PVR performed at the appropriate timing eases the burden on the RV allowing for a reduction in volumes, RV strain seems to continuously deteriorate as in patients who do not undergo PVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Tetralogia de Fallot/fisiopatologia , Tetralogia de Fallot/cirurgia , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Feminino , Humanos , Estudos Longitudinais , Masculino , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
5.
Med Ultrason ; 22(4): 402-408, 2020 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-32399536

RESUMO

AIMS: Carotid intima-media thickness (CIMT) is used increasingly as an imaging biomarker of cardiovascular risk (CVR). Our aim was to compare semiautomatic CIMT (sCIMT) versus manual CIMT (mCIMT) for reproducibility and prediction of CVR. MATERIALS AND METHODS: Two independent readers measured sCIMT and mCIMT on previously acquired images of the right common carotid artery of 200 consecutive patients. Measurements were performed twice, four weeks apart; sCIMT was reported along with an image quality index (IQI) provided by the software. CVR stratification was compared for thresholds established by mCIMT studies, adapted for sCIMT according to a regression model. RESULTS: sCIMT (median 0.67 mm, interquartile range [IQR] 0.57‒0.76 mm) was significantly lower (p<0.001) than mCIMT (median 0.76 mm, IQR 0.63‒0.84 mm; ρ=0.832, p<0.001, slope 0.714, intercept 0.124). Overall, intra-reader reproducibility was 76% for sCIMT and 83% for mCIMT (p=0.002), inter-reader reproducibility 75% and 76%, respectively (p=0.316). In 129 cases with IQI≥0.65, reproducibility was significantly higher (p≤0.004) for sCIMT than for mCIMT (intra-reader 85% versus 83%, inter-reader 80% versus 77%,). The agreement between sCIMT and mCIMT for CVR stratification was fair both overall (κ=0.270) and for IQI≥0.65 (κ=0.345), crude concordance being 79% and 88%, respectively. CONCLUSIONS: Reproducibility of sCIMT was not higher than mCIMT overall but sCIMT was significantly more reproducible than mCIMT for high-IQI cases. sCIMT cannot be used for CVR stratification due to fair concordance with mCIMT, even for high IQI. More research is required to improve image quality and define sCIMT-based thresholds for stratification of CVR.


Assuntos
Doenças Cardiovasculares , Espessura Intima-Media Carotídea , Doenças Cardiovasculares/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Fatores de Risco de Doenças Cardíacas , Humanos , Reprodutibilidade dos Testes , Fatores de Risco
6.
Clin Imaging ; 68: 102-107, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32585415

RESUMO

PURPOSE: The aim of this paper was to compare the open 1-T (O-1T) versus the closed 1.5-T (C-1.5T) cardiac magnetic resonance (MR). PATIENTS/METHODS: The MR examinations of two concurrent cohorts (each including 100 subjects) of patients with suspected or known cardiac disease were reviewed. Such examinations were obtained using O-1T or C-1.5T MRI. The bright-blood cine, T1-weighted (T1), T2-weighed short-tau inversion recovery (T2-STIR), late gadolinium enhancement (LGE) sequences were performed. Signal-to-noise ratio of blood (SNRb) or myocardium (SNRm), and contrast-to-noise ratio of myocardium (CNRm) were calculated. Subjective image quality (SIQ) of each sequence was graded as 0 = poor, 1 = intermediate, or 2 = optimal. Each examination was considered as diagnostic when the report answered the clinical question. RESULTS: C-1.5T was better than O-1T on cine for SNRb(median 172 versus 452), SNRm(71 versus 160) and CNRm (107 versus 265) and on T2-STIR for SNRb(10 versus 29), SNRm(74 versus 261) and CNRm(-67 versus -233)(P < 0.001). On LGE, SNRm was higher with O-1T than for C-1.5T (312 versus 79, P < 0.001) while CNR was lower (158 versus 389; P < 0.001). No significant differences were found for SNRb on LGE and both SNRm and CNRm on T1 (P ≥ 0.215). SIQ of O-1T was not significantly different from that of C-1.5T for both R1 and R2 for cine, T1, and LGE (P ≥ 0.157); for T2-STIR, SIQ of O-1T was significantly lower (P = 0.003). R1-R2 concordance was almost perfect (κ = 0.816-0.894), and all examinations were diagnostic. CONCLUSION: Even though quantitative measurements mostly favored C-1.5T, the SIQ of O-1T was not significantly different for any sequence, with the only exception of T2-STIR.


Assuntos
Meios de Contraste , Gadolínio , Coração , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
7.
Eur J Radiol ; 105: 153-161, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30017273

RESUMO

The importance of childhood and adolescence for bone development and mineral accrual is increasingly accepted, leading to a need of suitable methods for monitoring bone health even in pediatric setting. Among the several different imaging methods available for clinical measurement of bone mineral density (BMD) in children, dual-energy X-ray absorptiometry (DXA) is the most widely available and commonly used due to its reproducibility, negligible radiation dose and reliable pediatric reference data. Nevertheless, DXA in children has some technical specific features that should be known by those physicians who interpret and report this examination. We provide recommendations for optimal DXA scan reporting in pediatric setting, including indications, skeletal sites to be examined, parameters to be measured, timing of follow-up BMD measurements. Adequate report and analysis of DXA examinations are essential to prevent over- and underdiagnosis of bone mineral impairment in pediatric patients. In conclusion, a complete and exhaustive DXA report in children and adolescents is mandatory for an accurate diagnosis and a precise monitoring of pediatric bone status.


Assuntos
Absorciometria de Fóton , Densidade Óssea/fisiologia , Osso e Ossos/fisiologia , Desenvolvimento Infantil/fisiologia , Absorciometria de Fóton/métodos , Adolescente , Estatura , Peso Corporal , Criança , Feminino , Humanos , Masculino , Exame Físico/métodos , Guias de Prática Clínica como Assunto , Valores de Referência , Reprodutibilidade dos Testes , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA