Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 271
Filtrar
1.
Eur Radiol ; 33(10): 6948-6958, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37195432

RESUMO

OBJECTIVES: To evaluate at 1.5 and 3 T MRI the safety and performance of trademarked ENO®, TEO®, or OTO® pacing systems with automated MRI Mode and the image quality of non-enhanced MR examinations. METHODS: A total of 267 implanted patients underwent MRI examination (brain, cardiac, shoulder, cervical spine) at 1.5 (n = 126) or 3 T (n = 141). MRI-related device complications, lead electrical performances stability at 1-month post-MRI, proper functioning of the automated MRI mode and image quality were evaluated. RESULTS: Freedom from MRI-related complications at 1 month post-MRI was 100% in both 1.5 and 3 T arms (both p < 0.0001). The stability of pacing capture threshold was respectively at 1.5 and 3 T (atrial:: 98.9% (p = 0.001) and 100% (p < 0.0001); ventricular: both 100% (p < 0001)). The stability of sensing was respectively at 1.5 and 3 T (atrial: 100% (p = 0.0001) and 96.9% (p = 0.01); ventricular: 100% (p < 0.0001) and 99.1% (p = 0.0001)). All devices switched automatically to the programmed asynchronous mode in the MRI environment and to initially programmed mode after the MRI exam. While all MR examinations were assessed as interpretable, artifacts deteriorated a subset of examinations including mostly cardiac and shoulder ones. CONCLUSION: This study demonstrates the safety and electrical stability of ENO®, TEO®, or OTO® pacing systems at 1 month post-MRI at 1.5 and 3 T. Even if artifacts were noticed in a subset of examinations, overall interpretability was preserved. CLINICAL RELEVANCE STATEMENT: ENO®, TEO®, and OTO® pacing systems switch to MR-mode when detecting magnetic field and switch back on conventional mode after MRI. Their safety and electrical stability at 1 month post MRI were shown at 1.5 and 3 T. Overall interpretability was preserved. KEY POINTS: • Patients implanted with an MRI conditional cardiac pacemaker can be safely scanned under 1.5 or 3 Tesla MRI with preserved interpretability. • Electrical parameters of the MRI conditional pacing system remain stable after a 1.5 or 3 Tesla MRI scan. • The automated MRI mode enabled the automatic switch to asynchronous mode in the MRI environment and to initial settings after the MRI scan in all patients.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Segurança de Equipamentos/métodos , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos
2.
Clin Auton Res ; 33(4): 469-477, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37338634

RESUMO

PURPOSE: The effect of postural orthostatic tachycardia syndrome (POTS) on health-related quality of life (HrQoL) remains poorly studied. Here, we sought to compare the HrQoL in individuals with POTS to a normative age-/sex-matched population. METHODS: Participants enrolled in the Australian POTS registry between 5 August 2021 and 30 June 2022 were compared with propensity-matched local normative population data from the South Australian Health Omnibus Survey. The EQ-5D-5L instrument was used to assess HrQoL across the five domains (mobility, self-care, usual activities, pain/discomfort, and anxiety/depression) with global health rating assessed with a visual analog scale (EQ-VAS). A population-based scoring algorithm was applied to the EQ-5D-5L data to calculate utility scores. Hierarchical multiple regression analyses were undertaken to explore predictors of low utility scores. RESULTS: A total of 404 participants (n = 202 POTS; n = 202 normative population; median age 28 years, 90.6% females) were included. Compared with the normative population, the POTS cohort demonstrated significantly higher burden of impairment across all EQ-5D-5L domains (all P < 0.001), lower median EQ-VAS (p < 0.001), and lower utility scores (p < .001). The lower EQ-VAS and utility scores in the POTS cohort were universal in all age groups. Severity of orthostatic intolerance symptoms, female sex, fatigue scores, and comorbid diagnosis of myalgic encephalomyelitis/chronic fatigue syndrome were independent predictors of reduced HrQoL in POTS. The disutility in those with POTS was lower than many chronic health conditions. CONCLUSIONS: This is the first study to demonstrate significant impairment across all subdomains of EQ-5D-5L HrQoL in the POTS cohort as compared with a normative population. TRIAL REGISTRATION: ACTRN12621001034820.


Assuntos
Síndrome da Taquicardia Postural Ortostática , Qualidade de Vida , Humanos , Feminino , Adulto , Masculino , Síndrome da Taquicardia Postural Ortostática/epidemiologia , Austrália , Inquéritos Epidemiológicos , Comorbidade , Inquéritos e Questionários
3.
Heart Lung Circ ; 32(2): 252-260, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36443175

RESUMO

BACKGROUND: Most modern cardiac implantable electronic device (CIED) systems are now compatible with magnetic resonance imaging (MRI) scans. The requirement for both pre- and post-MRI CIED checks imposes significant workload to the cardiac electrophysiology service. Here, we sought to determine the burden of CIED checks associated with MRI scans. METHODS: We identified all CIED checks performed peri-MRI scans at our institution over a 3-year period between 1 July 2017 to 30 June 2020, comprising three separate financial years (FY). Device check reports, MRI scan reports and clinical summaries were collated. The workload burden was determined by assessing the occasions and duration of service. Analysis was performed to determine cost burden/projections for this service and identify factors contributing to the workload. RESULTS: A total of 739 CIED checks were performed in the peri-MRI scan setting (370 pre- and 369 post-MRI scan), including 5% (n=39) that were performed outside of routine hours (weekday <8 am or >5 pm, and weekends). MRIs were performed for 295 patients (75±13 years old, 64% male) with a CIED (88% permanent pacemaker, and 12% high voltage device), including 49 who had more than one MRI scan. The proportion of total MRI scans for patients with a CIED in-situ increased each FY (from 0.5% of all MRIs in FY1, to 0.9% in FY2, to 1.0% in FY3). The weekly workload increased (R2=0.2, p<0.001), but with week-to-week variability due to ad hoc scheduling (209 days with only one MRI vs 78 days with ≥2 MRIs for CIED patients). The projected annual cost of this service will increase to AUD$161,695 in 10 years for an estimated annual 546 MRI scans for CIED patients. CONCLUSIONS: There is an increasing workload burden and expense associated with CIED checks in the peri-MRI setting. Appropriate budgeting, staff allocation and standardisation of automated CIED pre-programming features among manufacturers are urgently needed.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Imageamento por Ressonância Magnética/métodos
4.
J Cardiovasc Electrophysiol ; 33(3): 414-422, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34981859

RESUMO

OBJECTIVE: To summarize data on the prevalence/incidence, risk factors and prognosis of atrial fibrillation (AF) in patients with acute coronary syndromes (ACS). METHODS: MEDLINE, Embase, and Web of Science were searched to identify all published studies providing relevant data through August 23, 2020. Random-effects meta-analysis method was used to pool estimates. RESULTS: We included 109 studies reporting data from a pooled population of 8 239 364 patients. The prevalence rates were 5.8% for pre-existing AF, 7.3% for newly diagnosed AF, and 11.3% for prevalent (total) AF, in patients with ACS. Predictors of newly diagnosed AF included age (per year increase) (adjusted odds ratio [aOR]: 1.05), C-reactive protein (aOR: 1.49), left atrial (LA) diameter (aOR: 1.08), LA dilatation (aOR: 2.32), left ventricular ejection fraction <40% (aOR: 1.82), hypertension (aOR: 1.87), and Killip ˃ 1 (aOR: 1.85), p < .01 in all analyzes. Newly diagnosed AF was associated with an increased risk of acute heart failure (adjusted hazard ratio [aHR]: 3.20), acute kidney injury (aHR: 3.09), re-infarction (aHR: 1.96), stroke (aHR: 2.15), major bleeding (aHR: 2.93), and mortality (aHR: 1.80) in the short term; and with an increased risk of heart failure (aHR: 2.21), stroke (aHR: 1.75), mortality (aHR: 1.67), CV mortality (aHR: 2.09), sudden cardiac death (aHR: 1.53), and a composite of major adverse cardiovascular events (aHR: 1.54) in the long term (beyond 1 month), p < .05 in all analyzes. CONCLUSION: One in nine patients with ACS has AF, with a high proportion of newly diagnosed AF. AF, in particular newly diagnosed AF, is associated with poor short-term and long-term outcomes in patients with ACS.


Assuntos
Síndrome Coronariana Aguda , Fibrilação Atrial , Acidente Vascular Cerebral , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/terapia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Humanos , Incidência , Prevalência , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Volume Sistólico , Função Ventricular Esquerda
5.
J Cardiovasc Electrophysiol ; 33(4): 608-617, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35077605

RESUMO

INTRODUCTION: Although single ring isolation is an accepted strategy for undertaking pulmonary vein (PV) and posterior wall isolation (PWI) during atrial fibrillation (AF) ablation, the learning curve associated with this technique as well as procedural and clinical success rates have not been widely reported. METHODS AND RESULTS: Prospectively collected data from 250 consecutive patients undergoing de novo AF ablation using single ring isolation. PWI was achieved in 212 patients (84.8%) and PV isolation without PWI was achieved in 37 patients (14.4%). Thirty-one cases (12.4%) demonstrated inferior line sparing where PWI was achieved without a continuous posterior wall inferior line. A learning curve was observed, with higher rates of PWI (98% last 50 vs. 82% first 50 cases, p = .016), higher rates of inferior line sparing (20% last 50 vs. 8% first 50 cases, p = .071) and lower ablation times (43.8 min (interquartile range [IQR]: 34.6-57.0 min) last 50 versus. 96.5 min (IQR: 80.8-115.8 min) first 50 cases; p < .001). Three (1.3%) major procedure-related complications were observed. Twelve-month, single-procedure freedom from atrial arrhythmia without drugs was 70.5% (95% confidence interval [CI]: 61.5%-77.7%) and 60.0% (95% CI: 50.2%-68.4%) for paroxysmal and persistent/longstanding persistent AF. Twelve-month multi-procedure freedom from atrial arrhythmia was 92.2% (95%CI: 85.6%-95.9%) and 85.6% (95%CI: 77.2%-91.0%) for paroxysmal and persistent/longstanding persistent AF. CONCLUSION: Employing a single ring isolation approach, PWI can be achieved in most cases. There is a substantial learning curve with higher rates of PWI, reduced ablation times, and higher rates of inferior line sparing as procedural experience grows. Long-term freedom from arrhythmia is comparable to other AF ablation techniques.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Curva de Aprendizado , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
6.
Europace ; 24(8): 1229-1239, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35061884

RESUMO

AIMS: To systematic review and meta-analyse the association and mechanistic links between atrial fibrillation (AF) and cognitive impairment. METHODS AND RESULTS: PubMed, EMBASE, and Cochrane Library were searched up to 27 March 2021 and yielded 4534 citations. After exclusions, 61 were analysed; 15 and 6 studies reported on the association of AF and cognitive impairment in the general population and post-stroke cohorts, respectively. Thirty-six studies reported on the neuro-pathological changes in patients with AF; of those, 13 reported on silent cerebral infarction (SCI) and 11 reported on cerebral microbleeds (CMB). Atrial fibrillation was associated with 39% increased risk of cognitive impairment in the general population [n = 15: 2 822 974 patients; hazard ratio = 1.39; 95% confidence interval (CI) 1.25-1.53, I2 = 90.3%; follow-up 3.8-25 years]. In the post-stroke cohort, AF was associated with a 2.70-fold increased risk of cognitive impairment [adjusted odds ratio (OR) 2.70; 95% CI 1.66-3.74, I2 = 0.0%; follow-up 0.25-3.78 years]. Atrial fibrillation was associated with cerebral small vessel disease, such as white matter hyperintensities and CMB (n = 8: 3698 patients; OR = 1.38; 95% CI 1.11-1.73, I2 = 0.0%), SCI (n = 13: 6188 patients; OR = 2.11; 95% CI 1.58-2.64, I2 = 0%), and decreased cerebral perfusion and cerebral volume even in the absence of clinical stroke. CONCLUSION: Atrial fibrillation is associated with increased risk of cognitive impairment. The association with cerebral small vessel disease and cerebral atrophy secondary to cardioembolism and cerebral hypoperfusion may suggest a plausible link in the absence of clinical stroke. PROSPERO CRD42018109185.


Assuntos
Fibrilação Atrial , Doenças de Pequenos Vasos Cerebrais , Disfunção Cognitiva , Acidente Vascular Cerebral , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Doenças de Pequenos Vasos Cerebrais/complicações , Doenças de Pequenos Vasos Cerebrais/epidemiologia , Disfunção Cognitiva/diagnóstico , Disfunção Cognitiva/epidemiologia , Humanos , Razão de Chances , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
7.
Europace ; 24(9): 1469-1474, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35178566

RESUMO

AIMS: There is a paucity of epidemiological evidence on alcohol and the risk of bradyarrhythmias. We thus characterized associations of total and beverage-specific alcohol consumption with incident bradyarrhythmias using data from the UK Biobank. METHODS AND RESULTS: Alcohol consumption reported at baseline was calculated as UK standard drinks (8 g alcohol)/week. Bradyarrhythmia events were defined as sinus node dysfunction (SND), high-level atrioventricular block (AVB), and permanent pacemaker implantations. Outcomes were assessed through hospitalization and death records, and dose-response associations were characterized using Cox regression models with correction for regression dilution bias. We studied 407 948 middle-aged individuals (52.4% female). Over a median follow-up time of 11.5 years, a total of 8 344 incident bradyarrhythmia events occurred. Increasing total alcohol consumption was not associated with an increased risk of bradyarrhythmias. Beer and cider intake were associated with increased bradyarrhythmia risk up to 12 drinks/week; however, no significant associations were observed with red wine, white wine, or spirit intake. When bradyarrhythmia outcomes were analysed separately, a negative curvilinear was observed for total alcohol consumption and risk of SND, but no clear association with AVB was observed. CONCLUSION: In this predominantly White British cohort, increasing total alcohol consumption was not associated with an increased risk of bradyarrhythmias. Associations appeared to vary according to the type of alcoholic beverage and between different types of bradyarrhythmias. Further epidemiological and experimental studies are required to clarify these findings.


Assuntos
Bloqueio Atrioventricular , Bradicardia , Consumo de Bebidas Alcoólicas/efeitos adversos , Consumo de Bebidas Alcoólicas/epidemiologia , Bebidas Alcoólicas/efeitos adversos , Bloqueio Atrioventricular/epidemiologia , Bradicardia/epidemiologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Síndrome do Nó Sinusal
8.
Europace ; 24(6): 1015-1024, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35348667

RESUMO

AIMS: Although in persistent atrial fibrillation (AF) a complex AF substrate characterized by a high incidence of conduction block has been reported, relatively little is known about AF complexity in paroxysmal AF (pAF). Also, the relative contribution of various aspects of structural alterations to conduction disturbances is not clear. In particular, the contribution of endomysial fibrosis to conduction disturbances during progression of AF has not been studied yet. METHODS AND RESULTS: During cardiac surgery, epicardial high-density mapping was performed in patients with acutely induced (aAF, n = 11), pAF (n = 12), and longstanding persistent AF (persAF, n = 9) on the right atrial (RA) wall, the posterior left atrial wall (pLA) and the LA appendage (LAA). In RA appendages, overall and endomysial (myocyte-to-myocyte distances) fibrosis and connexin 43 (Cx43) distribution were quantified. Unipolar AF electrogram analysis showed a more complex pattern with a larger number of narrower waves, more breakthroughs and a higher fractionation index (FI) in persAF compared with aAF and pAF, with no differences between aAF and pAF. The FI was consistently higher at the pLA compared with the RA. Structurally, Cx43 lateralization increased with AF progression (aAF = 7.5 ± 8.9%, pAF = 24.7 ± 11.1%, persAF = 35.1 ± 11.4%, P < 0.001). Endomysial but not overall fibrosis correlated with AF complexity (r = 0.57, P = 0.001; r = 0.23, P = 0.20; respectively). CONCLUSIONS: Atrial fibrillation complexity is highly variable in patients with pAF, but not significantly higher than in patients with acutely induced AF, while in patients with persistent AF complexity is higher. Among the structural alterations studied, endomysial fibrosis, but not overall fibrosis, is the strongest determinant of AF complexity.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Tecido Conjuntivo , Conexina 43 , Fibrose , Átrios do Coração , Humanos
9.
BMC Cardiovasc Disord ; 22(1): 204, 2022 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-35508964

RESUMO

Atrial fibrillation (AF) is the most common cardiac tachyarrhythmia and has a rising global prevalence. Given the increasing burden of AF-related symptoms and complications, new approaches to management are required. Anemia and iron deficiency are common conditions in patients with AF. Furthermore, emerging evidence suggests that the presence of anemia may be associated with worse outcome in these patients. The role of anemia and iron deficiency has been extensively explored in other cardiovascular states, such as heart failure and ischemic heart disease. In particular, the role of iron repletion amongst patients with heart failure is now an established treatment modality. However, despite the strong bidirectional inter-relationship between AF and heart failure, the implications of anemia and iron-deficiency in AF have been scarcely studied. This area is of mechanistic and clinical relevance given the potential that treatment of these conditions may improve symptoms and prognosis in the increasing number of individuals with AF. In this review, we summarise the current published literature on anemia and iron deficiency in patients with AF. We discuss AF complications such as stroke, bleeding, and heart failure, in addition to AF-related symptoms such as exercise intolerance, and the potential impact of anemia and iron deficiency on these. Finally, we summarize current research gaps on anemia, iron deficiency, and AF, and underscore potential research directions.


Assuntos
Anemia , Fibrilação Atrial , Insuficiência Cardíaca , Deficiências de Ferro , Acidente Vascular Cerebral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Acidente Vascular Cerebral/diagnóstico
10.
J Electrocardiol ; 73: 42-48, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35633601

RESUMO

BACKGROUND: Little data exists on electrogram sensing in current generation of miniaturized insertable cardiac monitors (ICMs). OBJECTIVE: To compare the sensing capability of ICM with different vector length: Medtronic Reveal LINQ (~40 mm) vs. Biotronik Biomonitor III (BM-III, ~70 mm). METHODS: De-identified remote monitoring transmissions from n = 40 patients with BM-III were compared with n = 80 gender and body mass index (BMI)-matched patients with Reveal LINQ. Digital measurement of P- and R-wave amplitude from calibrated ICM electrograms was undertaken by 3 investigators independently. Further, we evaluated the impact of BMI and gender on P-wave visibility. RESULTS: Patients in both groups were well matched for gender and BMI (53% male, mean BMI 26.7 kg/m2, both p = NS). Median P- and R-wave amplitude were 97% & 56% larger in the BM-III vs. LINQ [0.065 (IQR 0.039-0.10) vs. 0.033 (IQR 0.022-0.050) mV, p < .0001; & 0.78 (IQR 0.52-1.10) vs. 0.50 (IQR 0.41-0.89) mV, p = .012 respectively). The P/R-wave ratio was 36% greater with the BM-III (p < .001). The 25th percentile of P-wave amplitude for all 120 patients was .026 mV. Logistic regression analysis showed BM-III was more likely than LINQ to have P-wave amplitude ≥.026 mV (OR 7.47, 95%CI 1.965-29.42, p = .003), and increasing BMI was negatively associated with P-wave amplitude ≥.026 mV (OR 0.84, 95%CI 0.75-0.95, p = .004). However, gender was not significantly associated with P-wave amplitude ≥.026 mV (p = .37). CONCLUSION: The longer ICM sensing vector of BM-III yielded larger overall P- and R- wave amplitude than LINQ. Both longer sensing vector and lower BMI were independently associated with greater P-wave visibility.


Assuntos
Eletrocardiografia Ambulatorial , Eletrocardiografia , Feminino , Humanos , Masculino
11.
Eur Heart J ; 42(5): 520-528, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33321517

RESUMO

AIMS: Our objective was to determine the ventricular arrhythmia burden in implantable cardioverter-defibrillator (ICD) patients during COVID-19. METHODS AND RESULTS: In this multicentre, observational, cohort study over a 100-day period during the COVID-19 pandemic in the USA, we assessed ventricular arrhythmias in ICD patients from 20 centres in 13 states, via remote monitoring. Comparison was via a 100-day control period (late 2019) and seasonal control period (early 2019). The primary outcome was the impact of COVID-19 on ventricular arrhythmia burden. The secondary outcome was correlation with COVID-19 incidence. During the COVID-19 period, 5963 ICD patients underwent remote monitoring, with 16 942 episodes of treated ventricular arrhythmias (2.8 events per 100 patient-days). Ventricular arrhythmia burden progressively declined during COVID-19 (P < 0.001). The proportion of patients with ventricular arrhythmias amongst the high COVID-19 incidence states was significantly reduced compared with those in low incidence states [odds ratio 0.61, 95% confidence interval (CI) 0.54-0.69, P < 0.001]. Comparing patients remotely monitored during both COVID-19 and control periods (n = 2458), significantly fewer ventricular arrhythmias occurred during COVID-19 [incident rate ratio (IRR) 0.68, 95% CI 0.58-0.79, P < 0.001]. This difference persisted when comparing the 1719 patients monitored during both the COVID-19 and seasonal control periods (IRR 0.69, 95% CI 0.56-0.85, P < 0.001). CONCLUSIONS: During COVID-19, there was a 32% reduction in ventricular arrhythmias needing device therapies, coinciding with measures of social isolation. There was a 39% reduction in the proportion of patients with ventricular arrhythmias in states with higher COVID-19 incidence. These findings highlight the potential role of real-life stressors in ventricular arrhythmia burden in individuals with ICDs. TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry; URL: https://www.anzctr.org.au/; Unique Identifier: ACTRN12620000641998.


Assuntos
Arritmias Cardíacas/epidemiologia , COVID-19 , Desfibriladores Implantáveis , Fibrilação Ventricular/epidemiologia , Adulto , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , COVID-19/epidemiologia , COVID-19/prevenção & controle , Efeitos Psicossociais da Doença , Feminino , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Pandemias , Distanciamento Físico , Fatores de Proteção , Sistema de Registros , Fatores de Risco , Estresse Psicológico , Telemedicina , Estados Unidos/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia
12.
Heart Lung Circ ; 31(4): 537-543, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34674955

RESUMO

BACKGROUND: The use of cardiac implantable electronic devices (CIED), which includes pacemakers, implantable cardioverter-defibrillators (ICD), cardiac resynchronisation therapy pacemakers (CRT-P) and cardiac resynchronisation therapy defibrillators (CRT-D) has increased over the past 20 years, but there is a lack of real world evidence on the longevity of these devices in the older population which is essential to inform health care delivery and support clinical decisions. METHODS AND RESULTS: We conducted a retrospective cohort study using data from the Australian Government Department of Veterans' Affairs database. The cohort consisted of people who had a CIED procedure between 2005 and 2015. The cumulative risk of generator replacement/reoperations was estimated accounting for the competing risk of death. A total of 16,662 patients were included. In pacemaker recipients with an average age of 85 years, the 5-year risk of reoperation ranged from 2.8% in single chamber, 3.6% in dual chamber to 7.6% in CRT-P recipients, while the 5-year risk of dying with the index pacemaker in situ was 63% in single chamber, 46% in dual chamber and 56% in CRT-P recipients. In defibrillator recipients with an average age of 80 years, the 5-year risk of reoperation ranged from 11% in single chamber, 13% in dual chamber to 24% in CRT-D recipients, while the 5-year risk of dying with the index defibrillator in situ was 46% in single chamber, 40% in dual chamber and 41% in CRT-D recipients. CONCLUSION: In this cohort of older patients the 5-year risk of generator reoperation was low in pacemaker recipients whereas up to one in four CRT-D recipients would have a reoperation within 5 years.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Idoso de 80 Anos ou mais , Austrália/epidemiologia , Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos , Reoperação , Estudos Retrospectivos , Fatores de Risco
13.
Heart Lung Circ ; 31(8): 1119-1125, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35461785

RESUMO

BACKGROUND: Requests from the emergency department (ED) for cardiac implantable electronic device (CIED) checks constitute a large workload for cardiac electrophysiology services. We sought to determine the yield of, and clinical characteristics associated with, clinically relevant (remarkable) issues from ED CIED checks. METHODS: Consecutive CIED checks from our ED over a 12-month period were studied. A remarkable issue (RI) was defined as arrhythmia relating to the presentation or device/lead issue requiring reprogramming or intervention. The association between the presenting complaint and an RI was assessed using regression analysis. Multivariable regression model was used to identify pre-specified patient-level characteristics that were predictive of a RI. RESULTS: A RI was found in 28% (n=98) of 354 ED CIED checks for 306 patients (76±16 yrs, 59% male). Most patients had no RI (n=224, 73%). One third of checks occurred after-hours and these had a higher yield of RIs than those during routine clinic hours (35% vs 23%, p=0.018). Presenting with a perceived ICD shock was predictive of a RI (odds ratio [OR] 6.0, 95% CI=1.8-20.0). Syncope/presyncope was five-fold less likely to be predictive of a RI (OR 0.19, 95% CI=0.13-0.28) despite being the most common indication for CIED check (51%, n=180 checks). Only history of AF was predictive of RI while advancing age was predictive of not finding a RI. CONCLUSION: Almost three-quarters of ED CIED checks did not yield any RI. Patient-reported ICD shock and history of AF were predictive of RI, while syncope/presyncope was not. New models of care especially during after-hours, may help to reduce the burden on cardiac electrophysiology services and health care costs.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Atenção à Saúde , Eletrônica , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino
14.
J Cardiovasc Electrophysiol ; 32(3): 686-694, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33476452

RESUMO

BACKGROUND: Anemia frequently coexists with atrial fibrillation (AF) and has been variably associated with worse outcomes. We performed a systematic review and meta-analysis to comprehensively assess the effect of anemia on mortality, stroke/systemic thromboembolism, and bleeding events in patients with AF. METHODS: MEDLINE and Embase were searched from inception until May 2020. Studies examining associations of anemia with the above outcomes in AF patients were included, and maximally adjusted hazard ratios (HRs) meta-analysed. PROSPERO registration number CRD42020171113. RESULTS: Twenty-eight studies involving 365 484 patients (41% female, mean age 74.7 years) were included. The average study follow-up ranged from 0.2 to 4.0 years, and the prevalence of anemia was 16%. Anemia was associated with a 78% increase in all-cause mortality (HR, 1.78; 95% confidence interval [CI], 1.44-2.20), 60% increase in cardiovascular mortality (HR, 1.60; 95% CI, 1.17-2.19), 134% increase in noncardiovascular mortality (HR, 2.34; 95% CI, 1.58-3.47) 15% increase in stroke/systemic thromboembolism (HR, 1.15; 95% CI, 1.01-1.31), 78% increase in major bleeding (HR, 1.78; 95% CI, 1.54-2.05), and 77% increase in gastrointestinal bleeding (HR, 1.77; 95% CI, 1.23-2.55). Sensitivity analyses including studies that reported odds ratios did not result in any material change. CONCLUSION: Anemia is a frequently observed comorbidity in patients with AF, and is associated with an increased risk of all-cause, cardiovascular and noncardiovascular mortality, stroke/systemic thromboembolism, and major and gastrointestinal bleeding. Future studies are required to explore the causes of anemia in AF, and whether investigation and treatment may be clinically beneficial in affected individuals.


Assuntos
Anemia , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Anemia/diagnóstico , Anemia/epidemiologia , Anticoagulantes , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Feminino , Hemorragia/diagnóstico , Humanos , Masculino , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
15.
Europace ; 23(23 Suppl 2): ii52-ii60, 2021 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-33837759

RESUMO

The management of atrial fibrillation (AF) is multifaceted and treatment paradigms have changed significantly in the last century. The treatment of AF requires a comprehensive approach which goes beyond the treatment of the arrhythmia alone. Risk factor management has been introduced as a crucial pillar of AF management. As a result, the landscape of care delivery is changing as well, and novel models of comprehensive care delivery for AF have been introduced. This article reviews the evidence for the role of risk factor management in AF, how this can be integrated and implemented in clinical practice by applying novel models of care delivery, and finally identifies areas for ongoing research and potential healthcare reform to comprehensively manage the burgeoning AF population.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Atenção à Saúde , Humanos , Fatores de Risco , Gestão de Riscos
16.
Europace ; 23(10): 1528-1538, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34279604

RESUMO

AIMS: The aim of this study is to summarize data from prospective cohort studies on clinical predictors of stroke and systemic embolism in anticoagulant-naïve atrial fibrillation (AF) patients. METHODS AND RESULTS: EMBASE, MEDLINE, Global Index Medicus, and Web of Science were searched to identify all studies published by 28 November 2019. Forty-seven studies reporting data from 1 756 984 participants in 15 countries were included. The pooled incidence of stroke in anticoagulant-naïve AF patients was 23.8 per 1000 person-years (95% CI 19.7-28.2). Older age was associated with incident stroke or systemic embolism, with a pooled hazard ratio (HR) of 2.14 (95% CI 1.85-2.47), 2.83 (95% CI 2.27-3.51), and 6.87 (95% CI 6.33-7.44) for age 65-75, ≥75, and ≥85 years, respectively. Other predictors of stroke or systemic embolism included history of stroke or TIA (HR 2.84, 95% CI 2.19-3.67), hypertension (HR 1.60, 95% CI 1.37-1.86), diabetes (HR 1.28, 95% CI 1.20-1.37), heart failure (HR 1.25, 95% CI 1.11-1.40), peripheral artery disease (pooled HR 1.35, 95% CI 1.04-1.75), vascular disease (pooled HR 1.21, 95% CI 1.06-1.39), and prior myocardial infarction (pooled HR 1.08, 95% CI 1.03-1.14). Female sex was a predictor of thromboembolism in studies outside Asia (HR 1.35, 95% CI 1.15-1.59), but not in those done in Asia (HR 0.95, 95% CI 0.81-1.10). CONCLUSION: This study confirms age and prior stroke as the strongest predictors of stroke or systemic embolism in anticoagulant-naive AF patients. Other predictors include hypertension, diabetes, heart failure, and vascular disease. Female sex seems not to be universally associated with stroke or systemic embolism.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Anticoagulantes , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Feminino , Humanos , Estudos Prospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
17.
Europace ; 23(9): 1493-1501, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-34077513

RESUMO

AIMS: The aim of this study is to determine the association between the coronavirus disease 2019 (COVID-19) pandemic and atrial fibrillation (AF) occurrence in individuals with cardiac implantable electronic devices (CIEDs). METHOD AND RESULTS: Multi-centre, observational, cohort study over a 100-day period during the COVID-19 pandemic (COVID-19) in the USA. Remote monitoring was used to assess AF episodes in patients with a CIED (pacemaker or defibrillator; 20 centres, 13 states). For comparison, the identical 100-day period in 2019 was used (Control). The primary outcomes were the AF burden during the COVID-19 pandemic, and the association of the pandemic with AF occurrence, as compared with 1 year prior. The secondary outcome was the association of AF occurrence with per-state COVID-19 prevalence. During COVID-19, 10 346 CIEDs with an atrial lead were monitored. There were 16 570 AF episodes of ≥6 min transmitted (16 events per 1000 patient days) with a significant increase in proportion of patients with AF episodes in high COVID-19 prevalence states compared with low prevalence states [odds ratio 1.34, 95% confidence interval (CI) 1.21-1.48, P < 0.001]. There were significantly more AF episodes during COVID-19 compared with Control [incident rate ratio (IRR) 1.33, 95% CI 1.25-1.40, P < 0.001]. This relationship persisted for AF episodes ≥1 h (IRR 1.65, 95% CI 1.53-1.79, P < 0.001) and ≥6 h (IRR 1.54, 95% CI 1.38-1.73, P < 0.001). CONCLUSION: During the first 100 days of COVID-19, a 33% increase in AF episodes occurred with a 34% increase in the proportion of patients with AF episodes observed in states with higher COVID-19 prevalence. These findings suggest a possible association between pandemic-associated social disruptions and AF in patients with CIEDs. CLINICAL TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry: ACTRN12620000692932.


Assuntos
Fibrilação Atrial , COVID-19 , Desfibriladores Implantáveis , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Austrália , Estudos de Coortes , Humanos , Pandemias , SARS-CoV-2
18.
Europace ; 23(4): 494-495, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-32860039

RESUMO

AIMS: To develop quality indicators (QIs) that may be used to evaluate the quality of care and outcomes for adults with atrial fibrillation (AF). METHODS AND RESULTS: We followed the ESC methodology for QI development. This methodology involved (i) the identification of the domains of AF care for the diagnosis and management of AF (by a group of experts including members of the ESC Clinical Practice Guidelines Task Force for AF); (ii) the construction of candidate QIs (including a systematic review of the literature); and (iii) the selection of the final set of QIs (using a modified Delphi method). Six domains of care for the diagnosis and management of AF were identified: (i) Patient assessment (baseline and follow-up), (ii) Anticoagulation therapy, (iii) Rate control strategy, (iv) Rhythm control strategy, (v) Risk factor management, and (vi) Outcomes measures, including patient-reported outcome measures (PROMs). In total, 17 main and 17 secondary QIs, which covered all six domains of care for the diagnosis and management of AF, were selected. The outcome domain included measures on the consequences and treatment of AF, as well as PROMs. CONCLUSION: This document defines six domains of AF care (patient assessment, anticoagulation, rate control, rhythm control, risk factor management, and outcomes), and provides 17 main and 17 secondary QIs for the diagnosis and management of AF. It is anticipated that implementation of these QIs will improve the quality of AF care.


Assuntos
Fibrilação Atrial , Adulto , Comitês Consultivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Humanos , Indicadores de Qualidade em Assistência à Saúde , Fatores de Risco , Revisões Sistemáticas como Assunto
19.
Pacing Clin Electrophysiol ; 44(2): 266-273, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33433913

RESUMO

OBJECTIVE: To characterize contemporary pacemaker procedure trends. METHODS: Nationwide analysis of pacemaker procedures and costs between 2008 and 2017 in Australia. The main outcome measures were total, age- and gender-specific implant, replacement, and complication rates, and costs. RESULTS: Pacemaker implants increased from 12,153 to 17,862. Implantation rates rose from 55.3 to 72.6 per 100,000, a 2.8% annual increase (incidence rate ratio [IRR] 1.028; 95% CI, 1.02-1.04; p < .001). Pacemaker implants in the 80+ age group were 17.37-times higher than the < 50 group (95% CI 16.24-18.59; p < .001), and in males were 1.48-times higher than in females (95% CI 1.42-1.55; p < .001). However, there were similar increases according to age (p = .10) and gender (p = .68) over the study period. Left ventricular lead rates were stable (IRR 0.995; 95% CI 0.98-1.01; p = .53). Generator replacements decreased from 20.5 to 18.3 per 100,000 (IRR 0.975; 95% CI 0.97-0.98; p < .001). Although procedures for generator-related complications were stable (IRR 0.995; 95% CI 0.98-1.01; p = .54), those for lead-related complications decreased (IRR 0.985; 95% CI 0.98-0.99; p < .001). Rates for all pacemaker procedures were consistently greater in males (p < .001). Although annual costs of all pacemaker procedures increased from $178 million to $329 million, inflation-adjusted costs were more stable, rising from $294 million to $329 million. CONCLUSIONS: Increasing demand for pacemaker implants is driven by the ageing population and rising rates across all ages, while replacement and complication procedure rates appeared more stable. Males have consistently greater pacemaker procedure rates than females. Our findings have significant clinical and public health implications for healthcare resource planning.


Assuntos
Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Austrália , Custos e Análise de Custo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/economia , Marca-Passo Artificial/estatística & dados numéricos , Marca-Passo Artificial/tendências , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Utilização de Procedimentos e Técnicas/tendências , Estudos Retrospectivos , Fatores de Tempo
20.
Eur Heart J ; 41(15): 1479-1486, 2020 04 14.
Artigo em Inglês | MEDLINE | ID: mdl-31951255

RESUMO

AIMS: Physical activity reduces cardiovascular disease burden and mortality, although its relationship with cardiac arrhythmias is less certain. The aim of this study was to assess the association between self-reported physical activity and atrial fibrillation (AF), ventricular arrhythmias and bradyarrhythmias, across the UK Biobank cohort. METHODS AND RESULTS: We included 402 406 individuals (52.5% female), aged 40-69 years, with over 2.8 million person-years of follow-up who underwent self-reported physical activity assessment computed in metabolic equivalent-minutes per week (MET-min/wk) at baseline, detailed physical assessment and medical history evaluation. Arrhythmia episodes were diagnosed through hospital admissions and death reports. Incident AF risk was lower amongst physically active participants, with a more pronounced reduction amongst female participants [hazard ratio (HR) for 1500 vs. 0 MET-min/wk: 0.85, 95% confidence interval (CI) 0.74-0.98] than males (HR for 1500 vs. 0 MET-min/wk: 0.90, 95% CI 0.82-1.0). Similarly, we observed a significantly lower risk of ventricular arrhythmias amongst physically active participants (HR for 1500 MET-min/wk 0.78, 95% CI 0.64-0.96) that remained relatively stable over a broad range of physical activity levels between 0 and 2500 MET-min/wk. A lower AF risk amongst female participants who engaged in moderate levels of vigorous physical activity was observed (up to 2500 MET-min/wk). Vigorous physical activity was also associated with reduced ventricular arrhythmia risk. Total or vigorous physical activity was not associated with bradyarrhythmias. CONCLUSION: The risk of AF and ventricular arrhythmias is lower amongst physically active individuals. These findings provide observational support that physical activity is associated with reduced risk of atrial and ventricular arrhythmias.


Assuntos
Fibrilação Atrial , Bancos de Espécimes Biológicos , Adulto , Idoso , Fibrilação Atrial/epidemiologia , Estudos de Coortes , Exercício Físico , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Reino Unido/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA