Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Catheter Cardiovasc Interv ; 99(7): 2117-2124, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35395142

RESUMO

Rescue transcatheter aortic valve replacement (TAVR) in patients with cardiogenic shock is challenging, and there is limited literature on these critical patients. The aim of this study was to determine the characteristics and outcomes of patients undergoing TAVR, feasibility and safety of the procedure, and 1-year mortality factors. Thirty-eight patients with severe aortic disease and cardiogenic shock admitted to two French hospitals from 2015 to 2019 were included. The patients were critical, 78.9% of them had a left ventricular ejection fraction of <30%, and all of them received inotropic support. "Valve-in-valve" procedures were performed in 15.8% and 13.2% underwent balloon aortic valvuloplasty before TAVR. Edwards Sapien3® and Medtronic CoreValve EvolutR® were used. The survival probability remained reasonable for patients with cardiogenic shock who underwent rescue TAVR. The 30-day mortality rate was 7.9% and 21.1% at 1 year. No patient died during the intervention. The procedure was safe, with few complications except for acute kidney failure, the development of a left bundle branch block, and the need for pacemaker implantation. Both functional and echocardiographic results were good at 1 year, although 29% of the patients underwent rehospitalization within 1 year. The development of a left bundle branch block was found to be a mortality risk factor. This procedure is a safe and effective therapy with acceptable survivorship in critically ill patients. The benefits to their quality of life should be evaluated in future studies, and the need for providing early cardiac resynchronization therapy must be emphasized.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas , Bloqueio de Ramo/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Qualidade de Vida , Estudos Retrospectivos , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
2.
Catheter Cardiovasc Interv ; 99(6): 1829-1838, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35324050

RESUMO

OBJECTIVES: Report contemporary outcomes in patients included in the Mitragister registry and treated with transcatheter mitral valve implantation for failed surgical annuloplasty rings or deteriorated bioprosthesis. BACKGROUND: Midterm survival rates have been reported, but little is known about contemporary morbimortality endpoints. METHODS: The primary safety outcome was the technical success rate. The primary efficacy composite endpoint was a composite of cardiovascular mortality and heart failure hospitalizations. RESULTS: From 2016 to 2021, 102 patients (median age: 81 [74;84] years, 61% female, Euroscore II 11.0% [7.8;16.0]) undergoing valve-in-valve (ViV; n = 89) or valve-in-ring (ViR; n = 13) procedures were consecutively included. At baseline, ViR group patients had worse left ventricular ejection fraction (50% vs. 60%; p = 0.004) and more frequently severe regurgitation (46% vs. 15%; p = 0.014). The primary safety outcome was 95%: 77% and 98% in the ViR and ViV populations, respectively, (p = 0.014). At intermediate follow-up (6-12 months) clinical improvement was notable, 88% of the patients were in NYHA class ≤ II (vs. 25% at baseline; p < 0.001). At a mean follow-up of 17.1 ± 11.0 months, the primary efficacy composite reached 27%. By multivariate analysis, paravalvular leak (PVL) was the only independent predictor (hazard ratio: 2.39, 95% confidence interval: 1.08-5.29; p = 0.031) while ViR was not found statistically associated (p = 0.456). CONCLUSIONS: This study confirms the safety and efficacy of the mitral ViV procedure. ViR patients appear at higher risk of procedural complications. The presence of PVL could be associated with markedly worse midterm prognosis. Whatever the intervention, procedural strategies to reduce PVL incidence remain to be assessed to prevent latter adverse outcomes.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Bioprótese/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese , Sistema de Registros , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
J Card Surg ; 37(12): 5019-5026, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378912

RESUMO

BACKGROUND AND AIM: The mortality rate of patients with post-myocardial infarction (MI) ventricular septal defects (VSDs) is high, and the benefit of surgery is unclear. We aimed to investigate the management and outcomes of post-MI VSD over a 10-year period in a large cohort. METHODS: Data of patients with post-MI VSD admitted in three French university hospitals from 2008 to 2019 were examined. The characteristics of those who underwent surgery were compared with those who received medical treatment. Mortality risk factors, survival curves, and outcomes at 30 days and 1 year after treatment were determined. RESULTS: Of the 92 patients whose data were examined, 50 underwent surgery and 42 received exclusive medical treatment. All patients were critically ill. Overall, 76.1% of patients received inotropic support, and 63% received mechanical ventilation. Circulatory assistance, mainly via intra-aortic balloon pump and extra-corporeal membrane oxygenation, was provided to 46.7% patients, with 14.1% requiring a second assistance. The median time to surgery was 4 days. At 1 year, mortality was 46% in those who underwent surgery and 83.3% in those treated medically (p < .001). Survival curves at 1 and 3 months showed major differences, and the survival rate showed little change 30 days after treatment. Cardiogenic shock and cardiac arrest emerged as risk factors for mortality. CONCLUSIONS: In our retrospective, multicenter study, the mortality resulting from post-MI VSD did not seem to improve over the last decade. Although surgery carried considerable risks, it improved survival.


Assuntos
Comunicação Interventricular , Infarto do Miocárdio , Humanos , Estudos Retrospectivos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/cirurgia , Choque Cardiogênico/etiologia , Choque Cardiogênico/terapia , Comunicação Interventricular/etiologia , Fatores de Risco , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 98(5): 990-999, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34227735

RESUMO

OBJECTIVES: This study sought to investigate patient intermediate-term outcomes after transcatheter pulmonary valve replacement (TPVR) with Edwards SAPIEN valve. BACKGROUND: The Edwards SAPIEN valve, initially designed for percutaneous aortic valve replacement, has been approved for TPVR in patients with dysfunctional right ventricular outflow tracts (RVOT), but only short-term follow-up has been reported. METHODS: From 2011 to 2016, 62 patients undergoing successful TPVR using the SAPIEN XT valve were consecutively included into the study. Primary efficacy and safety endpoints were defined as freedom from valve-reintervention and freedom from infective endocarditis at last follow-up, respectively. RESULTS: The primary efficacy outcome was met for 87.1% patients after a mean follow-up of 4.6 ± 1.8 years, corresponding to a freedom of reintervention at 5 years of 89% (95% CI 74.8-95.6%). Reinterventions were exclusively due to recurrent obstruction, no significant valvular regurgitation was observed. One case of infective endocarditis was reported, corresponding to a rate of 0.35% per patient-year (95% CI 0.01-2.00%). At 5 years, freedom from infective endocarditis was 98.4% (95% CI 89.1-99.8%). Six patients died or were transplanted due to advanced cardiac failure, without relationship with TPVR. In univariate analysis, reintervention was associated with young age, a smaller tube-graft, a higher pulmonary valve gradient after the procedure and a ratio of largest implanted stent diameter to invasive balloon conduit diameter over 1.35. CONCLUSIONS: This study documents the mid-term safety and efficacy of the Edwards SAPIEN XT valve in patients with dysfunctional RVOT, and identifies a patient profile associated with an uncertain benefit-risk balance.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo , Cateterismo Cardíaco/efeitos adversos , Seguimentos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Sistema de Registros , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/cirurgia
5.
Artigo em Inglês | MEDLINE | ID: mdl-38468115

RESUMO

PURPOSE: Pre-stenting of the right ventricular outflow tract (RVOT) is commonly performed before percutaneous pulmonary valve implantation (PPVI), to relieve obstruction, prevent valved stent fractures, and provide a landing zone. This study aimed to evaluate the biomechanical characteristics of the stents currently used to perform pre-stenting of the RVOT. METHODS: We assessed five commercially available stents: Cheatham-Platinum Stent ("CP Stent"), AndraStent XL, AndraStent XXL, Optimus XL, and Optimus XXL. Following stent deployment at nominal pressure, radial and longitudinal elastic recoils and radial resistance were measured. The bending stiffness of the stents crimped onto the balloons was also evaluated. RESULTS: Three samples were tested for each stent. Our study showed no significant difference between the stent platforms in terms of radial elastic recoil, which was relatively low (< 10%). The longitudinal elastic recoil was also low for all the devices (< 5%). Significant differences were observed in radial resistance (P < 0.001). CP Stent and AndraStent XL exhibited the highest radial resistances. The bending stiffnesses of the stents crimped on their balloons were significantly different (P < 0.00001). Optimus XL and XXL were more flexible than the other stents. CONCLUSION: This study highlights the significant differences between the stents currently used in RVOT pre-stenting. Stents with good radial resistance are preferred, especially for calcified vessels, and flexibility is crucial for tortuous vessels. We proposed an algorithm for selecting the most suitable stent according to the need for radial force and flexibility, which will help inform clinicians considering RVOT revalvulation.

6.
Heart ; 110(9): 666-674, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38148157

RESUMO

OBJECTIVE: Variants in the FLNA gene have been associated with mitral valve dystrophy (MVD), and even polyvalvular disease has been reported. This study aimed to analyse the aortic valve and root involvement in FLNA-MVD families and its impact on outcomes. METHODS: 262 subjects (37 (18-53) years, 140 male, 79 carriers: FLNA+) from 4 FLNA-MVD families were included. Echocardiography was performed in 185 patients and histological analysis in 3 explanted aortic valves. The outcomes were defined as aortic valve surgery or all-cause mortality. RESULTS: Aortic valve alterations were found in 58% of FLNA+ compared with 6% of FLNA- (p<0.001). 9 (13.4%) FLNA+ had bicuspid aortic valve compared with 4 (3.4%) FLNA- (p=0.03). Overall, the transvalvular mean gradient was slightly increased in FLNA+ (4.8 (4.1-6.1) vs 4.0 (2.9-4.9) mm Hg, p=0.02). The sinuses of Valsalva and sinotubular junction diameters were enlarged in FLNA+ subjects (all p<0.05). 8 FLNA+ patients underwent aortic valve surgery (0 in relatives; p<0.001). Myxomatous remodelling with an infiltration of immune cells was observed. Overall survival was similar between FLNA+ versus FLNA- subjects (86±5% vs 85±6%, p=0.36). There was no statistical evidence for an interaction between genetic status and sex (p=0.15), but the survival tended to be impaired in FLNA+ men (p=0.06) whereas not in women (p=0.71). CONCLUSION: The patients with FLNA variants present frequent aortic valve disease and worse outcomes. Bicuspid aortic valve is more frequent in patients carrying the FLNA-MVD variants. These unique features should be factored into the management of patients with dystrophic and/or bicuspid aortic valve.


Assuntos
Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Cardiopatia Reumática , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Filaminas/genética , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/genética , Doenças das Valvas Cardíacas/cirurgia
7.
Int J Cardiol ; 390: 131139, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37355239

RESUMO

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Esquerda , Fatores de Tempo , Transplante de Coração/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Sistema de Registros , Implante de Prótese de Valva Cardíaca/métodos
8.
Arch Cardiovasc Dis ; 115(10): 521-528, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36115768

RESUMO

BACKGROUND: Management of mitral regurgitation recurrence after failed surgical valve repair with ring implantation is controversial. AIM: To describe the French experience regarding midterm safety and efficacy of transcatheter edge-to-edge mitral valve repair (TEER) in patients with failed surgical valve repair with ring implantation. METHODS: The "Clip-in-Ring" registry is a multicentre registry conducted in 11 centres in France, approved by local institutional review boards, of consecutive TEER following surgical valve repair with ring implantation. Outcomes were Mitral Valve Academic Research Consortium (MVARC) technical success, modified 30-day device and procedural success (where 10mmHg is considered as a cut-off for significant mitral stenosis) and MVARC complications. RESULTS: Twenty-three patients were studied: mean age, 69±10years; male sex, 74%; EuroSCORE II, 16±17; left ventricular ejection fraction, 53±12%; mitral regurgitation grade 3+/4+, 17%/78%; New York Heart Association class III/IV, 47%/22%; median surgery to TEER delay, 23 (6-94) months. Technical success was 100%. At discharge, residual mitral regurgitation grade was≤2+ in 87% and median transmitral gradient was 4 (3-5) mmHg. Thirty-day modified MVARC device and procedural success was 82%: four patients (17%) had residual mitral regurgitation grade>2+, including two patients who needed complementary surgery. No patient had a 30-day transmitral gradient>7mmHg. No patient died or had a stroke or any life-threatening complications. One patient presented a vascular access complication requiring transfusion. No other MVARC-2 adverse event was reported. CONCLUSIONS: TEER in patients with failed mitral ring is feasible and safe. Further studies should delineate its exact role in the therapeutic armamentarium for this medical issue.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Instrumentos Cirúrgicos , Sistema de Registros , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos
9.
JACC Case Rep ; 3(3): 486-490, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34317564

RESUMO

Intra-axial pumps are increasingly used to support cardiogenic shock. The occurrence of electrical storms in this setting is a rising issue, and data remain scarce about optimal management. We report the feasibility of ventricular tachycardia ablation in the presence of a recent surgically inserted Impella 5.0 device (Abiomed, Danvers, Massachusetts). (Level of Difficulty: Intermediate.).

10.
JACC Case Rep ; 3(1): 64-68, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34317470

RESUMO

Transcatheter aortic valve replacement is currently used off-label for noncalcified aortic valve regurgitation and therefore is restricted to selected cases. In this setting we describe a rare complication of Sapien 3 (Edwards Lifesciences, Irvine, California) embolization from the left ventricle to the descending aorta. Given their technical challenges, such procedures require specific considerations and management. (Level of Difficulty: Advanced.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA