Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Nat Immunol ; 22(3): 336-346, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33574616

RESUMO

The anatomic location and immunologic characteristics of brain tumors result in strong lymphocyte suppression. Consequently, conventional immunotherapies targeting CD8 T cells are ineffective against brain tumors. Tumor cells escape immunosurveillance by various mechanisms and tumor cell metabolism can affect the metabolic states and functions of tumor-infiltrating lymphocytes. Here, we discovered that brain tumor cells had a particularly high demand for oxygen, which affected γδ T cell-mediated antitumor immune responses but not those of conventional T cells. Specifically, tumor hypoxia activated the γδ T cell protein kinase A pathway at a transcriptional level, resulting in repression of the activatory receptor NKG2D. Alleviating tumor hypoxia reinvigorated NKG2D expression and the antitumor function of γδ T cells. These results reveal a hypoxia-mediated mechanism through which brain tumors and γδ T cells interact and emphasize the importance of γδ T cells for antitumor immunity against brain tumors.


Assuntos
Neoplasias Encefálicas/imunologia , Citotoxicidade Imunológica , Glioblastoma/imunologia , Linfócitos Intraepiteliais/imunologia , Linfócitos do Interstício Tumoral/imunologia , Evasão Tumoral , Microambiente Tumoral , Animais , Apoptose , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/metabolismo , Neoplasias Encefálicas/patologia , Antígenos CD8/genética , Antígenos CD8/metabolismo , Linhagem Celular Tumoral , Técnicas de Cocultura , Proteínas Quinases Dependentes de AMP Cíclico/metabolismo , Regulação Neoplásica da Expressão Gênica , Genes Codificadores da Cadeia delta de Receptores de Linfócitos T , Glioblastoma/genética , Glioblastoma/metabolismo , Glioblastoma/patologia , Humanos , Linfócitos Intraepiteliais/metabolismo , Linfócitos Intraepiteliais/patologia , Linfócitos do Interstício Tumoral/metabolismo , Linfócitos do Interstício Tumoral/patologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Endogâmicos NOD , Camundongos Knockout , Camundongos Nus , Subfamília K de Receptores Semelhantes a Lectina de Células NK/genética , Subfamília K de Receptores Semelhantes a Lectina de Células NK/metabolismo , Fenótipo , Transdução de Sinais , Hipóxia Tumoral
2.
Small ; 19(47): e2302713, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37485739

RESUMO

The fundamental aspects of energy dissipation on 2-dimensional (2D) atomic layers are extensively studied. Among various atomic layers, transition metal dichalcogenides (TMDs) exists in several phases based on their lattice structure, which give rise to the different phononic and electronic contributions in energy dissipation. 2H and 1T' (distorted 1T) phase MoS2 and MoTe2 atomic layers exfoliated on mica substrate are obtained and investigated their nanotribological properties with atomic force microscopy (AFM)/ friction force microscopy (FFM). Surprisingly, 1T' phase of both MoS2 and MoTe2 exhibits ≈10 times higher friction compared to 2H phase. With density functional theory analyses, the friction increase is attributed to enhanced electronic excitation, efficient phonon dissipation, and increased potential energy surface barrier at the tip-sample interface. This study suggests the intriguing possibility of tuning the friction of TMDs through phase transition, which can lead to potential application in tunable tribological devices.

3.
NMR Biomed ; 36(7): e4901, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36632695

RESUMO

The purpose of the current study was to develop spatially and velocity-selective (SVS) magnetization preparation pulses for noncontrast-enhanced peripheral MR angiography (MRA) to provide comparisons with velocity-selective (VS) MRA with comparison to velocity-selective (VS). VS preparation pulses were designed by concatenating multiple excitation steps, each of which was a combination of a hard RF pulse, VS unipolar gradient pulses, and refocusing RF pulses. SVS preparation pulses were designed by replacing the hard RF pulse with a sinc-shaped RF pulse combined with a symmetric tripolar gradient pulse (which does not perturb the velocity encoding by the VS unipolar gradient pulses). Numerical simulations were performed to verify the intended hybrid excitation selectivity of SVS pulses taking account of tissue relaxation, magnetic field errors, and eddy currents. In vivo experiments were performed in healthy subjects to verify the hybrid excitation selectivity, as well as to demonstrate the visualization of the entire peripheral arteries using six-station protocols. As demonstrated by numerical simulations, SVS preparation yielded a notch-shaped longitudinal magnetization (Mz )-velocity response within the spatial stopband (the same as VS preparation) and preserved the Mz of spins outside the stopband, regardless of its velocity. We confirmed these observations also through in vivo tests with good agreement in normalized arterial and muscle signal intensities. In six-station peripheral MRA experiments, the proposed SVS-MRA yielded significantly higher arterial signal-to-noise ratio (SNR) (51.6 ± 14.3 vs. 38.9 ± 10.9; p < 0.001) and contrast-to-noise ratio (CNR) (41.2 ± 13.0 vs. 31.3 ± 10.5; p < 0.001) compared with VS-MRA. The proposed SVS-MRA improves arterial SNR and CNR compared with VS-MRA by mitigating undesired presaturation of arterial blood upstream the imaging field of view.


Assuntos
Artérias , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Razão Sinal-Ruído
4.
Eur Radiol ; 33(4): 2686-2698, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36378250

RESUMO

OBJECTIVES: The study aimed to develop a deep neural network (DNN)-based noise reduction and image quality improvement by only using routine clinical scans and evaluate its performance in 3D high-resolution MRI. METHODS: This retrospective study included T1-weighted magnetization-prepared rapid gradient-echo (MP-RAGE) images from 185 clinical scans: 135 for DNN training, 11 for DNN validation, 20 for qualitative evaluation, and 19 for quantitative evaluation. Additionally, 18 vessel wall imaging (VWI) data were included to evaluate generalization. In each scan of the DNN training set, two noise-independent images were generated from the k-space data, resulting in an input-label pair. 2.5D U-net architecture was utilized for the DNN model. Qualitative evaluation between conventional MP-RAGE and DNN-based MP-RAGE was performed by two radiologists in image quality, fine structure delineation, and lesion conspicuity. Quantitative evaluation was performed with full sampled data as a reference by measuring quantitative error metrics and volumetry at 7 different simulated noise levels. DNN application on VWI was evaluated by two radiologists in image quality. RESULTS: Our DNN-based MP-RAGE outperformed conventional MP-RAGE in all image quality parameters (average scores = 3.7 vs. 4.9, p < 0.001). In the quantitative evaluation, DNN showed better error metrics (p < 0.001) and comparable (p > 0.09) or better (p < 0.02) volumetry results than conventional MP-RAGE. DNN application to VWI also revealed improved image quality (3.5 vs. 4.6, p < 0.001). CONCLUSION: The proposed DNN model successfully denoises 3D MR image and improves its image quality by using routine clinical scans only. KEY POINTS: • Our deep learning framework successfully improved conventional 3D high-resolution MRI in all image quality parameters, fine structure delineation, and lesion conspicuity. • Compared to conventional MRI, the proposed deep neural network-based MRI revealed better quantitative error metrics and comparable or better volumetry results. • Deep neural network application to 3D MRI whose pulse sequences and parameters were different from the training data showed improvement in image quality, revealing the potential to generalize on various clinical MRI.


Assuntos
Aprendizado Profundo , Humanos , Estudos Retrospectivos , Melhoria de Qualidade , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos
5.
Sensors (Basel) ; 23(16)2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37631659

RESUMO

In this study, the problems encountered in radar cross-section (RCS) measurement experiments utilizing a dielectric barrier discharge (DBD) plasma system are examined and an effective solution is proposed. A DBD plasma system generates heat due to the high bias voltage required for plasma generation. The thermal-induced structural deformation of the DBD structure caused by this high voltage and its impact on RCS measurements are analyzed. In addition, techniques for minimizing the thermal-induced deformation and compensation methods for addressing the minimized deformation are proposed. Furthermore, RCS measurements are conducted on two kinds of DBD structures using the proposed method to experimentally demonstrate the improved agreement between the simulation and measurement results. For both structures, the RCS experimental results are in very good agreement with the simulation results, which enables accurate plasma characterization. In conclusion, it can be expected that the proposed method can be used to provide more accurate RCS measurements on various DBD structures that generate high heat.

6.
Sensors (Basel) ; 23(22)2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-38005554

RESUMO

This paper deals with the practical application of Radar Cross Section (RCS) reduction technology using plasma. Although various plasma application technologies for RCS reduction have been studied, there are still many issues to be addressed for practical implementation. In order to achieve actual application, the discharge should be sustained regardless of the external environment of the aircraft. It is also important to investigate the actual plasma parameters to determine the expected RCS reduction effect. Building upon previous studies that optimized the electrodes for RCS reduction, this study fabricates a Dielectric Barrier Discharge (DBD) source suitable for dynamic environments and verifies the power consumption during one cycle of plasma generation. The obtained results are expected to contribute to the optimization of DBD electrodes for plasma RCS reduction.

7.
Nature ; 535(7610): 131-5, 2016 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-27362224

RESUMO

Three-dimensional graphene architectures with periodic nanopores­reminiscent of zeolite frameworks­are of topical interest because of the possibility of combining the characteristics of graphene with a three-dimensional porous structure. Lately, the synthesis of such carbons has been approached by using zeolites as templates and small hydrocarbon molecules that can enter the narrow pore apertures. However, pyrolytic carbonization of the hydrocarbons (a necessary step in generating pure carbon) requires high temperatures and results in non-selective carbon deposition outside the pores. Here, we demonstrate that lanthanum ions embedded in zeolite pores can lower the temperature required for the carbonization of ethylene or acetylene. In this way, a graphene-like carbon structure can be selectively formed inside the zeolite template, without carbon being deposited at the external surfaces. X-ray diffraction data from zeolite single crystals after carbonization indicate that electron densities corresponding to carbon atoms are generated along the walls of the zeolite pores. After the zeolite template is removed, the carbon framework exhibits an electrical conductivity that is two orders of magnitude higher than that of amorphous mesoporous carbon. Lanthanum catalysis allows a carbon framework to form in zeolite pores with diameters of less than 1 nanometre; as such, microporous carbon nanostructures can be reproduced with various topologies corresponding to different zeolite pore sizes and shapes. We demonstrate carbon synthesis for large-pore zeolites (FAU, EMT and beta), a one-dimensional medium-pore zeolite (LTL), and even small-pore zeolites (MFI and LTA). The catalytic effect is a common feature of lanthanum, yttrium and calcium, which are all carbide-forming metal elements. We also show that the synthesis can be readily scaled up, which will be important for practical applications such as the production of lithium-ion batteries and zeolite-like catalyst supports.

8.
Magn Reson Med ; 86(5): 2656-2665, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34184310

RESUMO

PURPOSE: To implement a single-shot centric-reordered EPI (1sh-CenEPI), which reduces TE significantly, thus enabling to improve SNR for magnetization-prepared imaging. METHODS: We proposed a 1sh-CenEPI in which grouped oscillating readout gradients, phase-encoding blips within each group, and big phase-encoding jumps between two consecutive groups are incorporated to encode whole k-space from the center to the edges in a single shot. The concept was tested on phantoms and human brains at 3 T. In addition, the proposed reordering scheme was applied to pseudo-continuous arterial spin labeling for evaluating the efficiency of the centric reordering in magnetization-prepared imaging. RESULTS: The proposed 1sh-CenEPI reduced TE from 50 ms to 1.4 ms for gradient-echo EPI, and from 100 ms to 7 ms for spin-echo EPI, while the elongation of readout duration was below 10% of the whole readout duration in most cases. The 1sh-CenEPI images exhibited no distinct geometric distortion both in phantom and human brain, comparable to the conventional two-shot center-out EPI. In pseudo-continuous arterial spin labeling results, 3-fold temporal SNR increase and 2-fold spatial SNR increase in the perfusion-weighted images were achieved with 1sh-CenEPI compared with the conventional linear ordering, whereas the cerebral blood flow values were consistent with previous studies. CONCLUSION: The proposed 1sh-CenEPI significantly reduced TE while maintaining similar readout window and providing images comparable to the conventional linear and multishot center-out EPI images. It can be a qualified candidate as a new readout for various magnetization-prepared imaging techniques.


Assuntos
Circulação Cerebrovascular , Imagem Ecoplanar , Encéfalo/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Marcadores de Spin
9.
Am J Pathol ; 190(1): 125-133, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31669306

RESUMO

Neuroinflammation plays an important role in the pathogenesis of ocular surface disease, including dry eye disease (DED), but little is known about the contribution of substance P (SP) to DED. In this study, we investigated the expression of SP at the ocular surface and evaluated its effect on maturation of antigen-presenting cells (APCs), the key cell component involved in the induction of type 17 helper T-cell (Th17) response in DED. The effect of topical blockade of SP signaling was further investigated using neurokinin-1 receptor (NK1R) inhibitors on APC maturation, Th17 cell activation, and disease severity in a mouse model of DED. The results demonstrate that SP is constitutively expressed at the ocular surface, and trigeminal ganglion neurons are the major source of SP in DED. SP derived from trigeminal ganglion enhanced the expression of major histocompatibility complex class II maturation marker by bone marrow-derived dendritic cells, an effect that is abrogated by blockade of SP signaling using NK1R antagonist spantide. Finally, using a well-established murine model of DED, topical treatment of DED mice with NK1R antagonists CP-99,994 and L-733,060 suppressed APC acquisition of major histocompatibility complex class II, reduced Th17 cell activity, and ameliorated DED severity. These findings are of translational value, as they suggest that antagonizing NK1R-mediated SP signaling may be an effective strategy in suppressing Th17-mediated ocular surface disease.


Assuntos
Células Apresentadoras de Antígenos/imunologia , Modelos Animais de Doenças , Síndromes do Olho Seco/prevenção & controle , Antagonistas dos Receptores de Neurocinina-1/farmacologia , Receptores da Neurocinina-1/química , Células Th17/imunologia , Animais , Células Apresentadoras de Antígenos/efeitos dos fármacos , Córnea/efeitos dos fármacos , Córnea/imunologia , Síndromes do Olho Seco/imunologia , Síndromes do Olho Seco/metabolismo , Síndromes do Olho Seco/patologia , Feminino , Linfonodos/efeitos dos fármacos , Linfonodos/imunologia , Camundongos , Camundongos Endogâmicos C57BL , Células Th17/efeitos dos fármacos
10.
Nano Lett ; 19(2): 891-896, 2019 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-30608712

RESUMO

Direct measurement of hot electron flux from a plasmonic Schottky nanodiode is important for obtaining fundamental insights explaining the mechanism for electronic excitation on a surface. Here, we report the measurement of photoinduced hot electrons on a triangular Au nanoprism on TiO2 under incident light with photoconductive atomic force microscopy (pc-AFM), which is direct proof of the intrinsic relation between hot electrons and localized surface plasmon resonance. We find that the local photocurrent measured on the boundary of the Au nanoprism is higher than that inside the Au nanoprism, indicating that field confinement at the boundary of the Au nanoprism acts as a hot spot, leading to the enhancement of hot electron flow at the boundary. Under incident illumination with a wavelength near the absorption peak (645 nm) of a single Au nanoprism, localized surface plasmon resonance resulted in the generation of a higher photoinduced hot electron flow for the Au nanoprism/TiO2, compared with that at a wavelength of 532 nm. We show that the application of a reverse bias results in a higher photocurrent for the Au nanoprism/TiO2, which is associated with a lowering of the Schottky barrier height caused by the image force. These nanoscale measurements of hot electron flux with pc-AFM indicate efficient photon energy transfer mediated by surface plasmons in hot electron-based energy conversion.

11.
Angew Chem Int Ed Engl ; 59(43): 19202-19208, 2020 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-32618117

RESUMO

Distance-dependent electromagnetic radiation and electron transfer have been commonly employed in washing-free fluorescence and electrochemical bioassays, respectively. In this study, we combined the two distance-dependent phenomena for sensitive washing-free DNA detection. A distance-dependent surface plasmonic field induces rapid photoredox catalysis of surface-bound catalytic labels, and distance-dependent mediated electron transfer allows for rapid electron transfer from the surface-bound labels to the electrode. An optimal system consists of a chemically reversible acceptor (Ru(NH3 )63+ ), a chemically reversible photoredox catalyst (eosin Y), and a chemically irreversible donor (triethanolamine). Side reactions with O2 do not significantly decrease the efficiency of photoredox catalysis. Energy transfer quenching between the electrode and the label can be lowered by increasing the distance between them. Washing-free DNA detection had a detection limit of approximately 0.3 nm in buffer and 0.4 nm in serum without a washing step.


Assuntos
DNA/análise , Luz , Catálise , Transporte de Elétrons , Limite de Detecção , Oxirredução , Ressonância de Plasmônio de Superfície
12.
Sensors (Basel) ; 19(5)2019 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-30813514

RESUMO

Recently, device-free human activity⁻monitoring systems using commercial Wi-Fi devices have demonstrated a great potential to support smart home environments. These systems exploit Channel State Information (CSI), which represents how human activities⁻based environmental changes affect the Wi-Fi signals propagating through physical space. However, given that Wi-Fi signals either penetrate through an obstacle or are reflected by the obstacle, there is a high chance that the housing environment would have a great impact on the performance of a CSI-based activity-recognition system. In this context, this paper examines whether and to what extent housing environment affects the performance of the CSI-based activity recognition systems. Activities in daily living (ADL)⁻recognition systems were implemented in two typical housing environments representative of the United States and South Korea: a wood-frame apartment (Unit A) and a reinforced concrete-frame apartment (Unit B), respectively. The experimental results show that housing environments, combined with various environmental factors (i.e., structural building materials, surrounding Wi-Fi interference, housing layout, and population density), generate a significant difference in the accuracy of the applied CSI-based ADL-recognition systems. This outcome provides insights into how such ADL systems should be configured for various home environments.

13.
Magn Reson Med ; 78(1): 254-263, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27417134

RESUMO

PURPOSE: To develop single and double acquisition methods to compensate for artifacts from eddy currents and transient oscillations in balanced steady-state free precession (bSSFP) with centric phase-encoding (PE) order for magnetization-prepared bSSFP imaging. THEORY AND METHODS: A single and four different double acquisition methods were developed and evaluated with Bloch equation simulations, phantom/in vivo experiments, and quantitative analyses. For the single acquisition method, multiple PE groups, each of which was composed of N linearly changing PE lines, were ordered in a pseudocentric manner for optimal contrast and minimal signal fluctuations. Double acquisition methods used complex averaging of two images that had opposite artifact patterns from different acquisition orders or from different numbers of dummy scans. RESULTS: Simulation results showed high sensitivity of eddy-current and transient-oscillation artifacts to off-resonance frequency and PE schemes. The artifacts were reduced with the PE-grouping with N values from 3 to 8, similar to or better than the conventional pairing scheme of N = 2. The proposed double acquisition methods removed the remaining artifacts significantly. The proposed methods conserved detailed structures in magnetization transfer imaging well, compared with the conventional methods. CONCLUSION: The proposed single and double acquisition methods can be useful for artifact-free magnetization-prepared bSSFP imaging with desired contrast and minimized dummy scans. Magn Reson Med 78:254-263, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Artefatos , Encéfalo/diagnóstico por imagem , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Técnica de Subtração , Humanos , Imageamento por Ressonância Magnética/instrumentação , Oscilometria/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Nanotechnology ; 27(33): 335603, 2016 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-27389518

RESUMO

We synthesized black SnO single-crystal microplates via a sonochemical process and engineered the work function of the SnO microplates using thermal treatments. The as-synthesized SnO microplates have a wide (001) plane, as is clearly evident from TEM images and diffraction patterns. Surface potential measurements on the SnO microplates show that the work function changes as the annealing temperature increases. The TEM and XAS results after thermal treatments imply that the micro-sized SnO(001) single-crystals are stable up to about 400 °C in air, after which the surface starts to become locally oxidized. Consequently, the long-range ordering and lattice parameter of the SnO(001) single crystals started to change to make polycrystalline SnO2 at about 600 °C. These results demonstrate the ability to tune the work function of the microplates and suggest an intriguing way to engineer the electrical properties of nanostructures.

15.
Nanotechnology ; 27(21): 215601, 2016 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-27087356

RESUMO

We demonstrate the charge transport properties of a self-assembled organic monolayer on Au nanoplates with conductive probe atomic force microscopy (CP-AFM). Atomically flat Au nanoplates, a few hundred micrometers on each side, that have only (111) surfaces, were synthesized using the chemical vapor transport method; these nanoplates were employed as the substrates for hexadecanethiol (HDT) self-assembled monolayers (SAMs). Atomic-scale high-resolution images show (√3 x √3) R30° molecular periodicity, indicating a well-ordered structure of the HDT on the Au nanoplates. We observed reduced friction and adhesion forces on the HDT SAMs on Au nanoplates, compared with Si substrates, which is consistent with the lubricating nature of HDT SAMs. The electrical properties, such as I-V characteristics and current as a function of load, were measured using CP-AFM. We obtained a tunneling decay constant (ß) of 0.57 Å(-1), including through-bond (ßtb = 0.99 Å(-1)) and through-space (ßts = 1.36 Å(-1)) decay constants for the two-pathway model. This indicates that the charge transport properties of HDT SAMs on Au nanoplates are consistent with those on a Au (111) film, suggesting that SAMs on nanoplates can provide a new building block for molecular electronics.

16.
Alzheimer Dis Assoc Disord ; 29(3): 213-21, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25187218

RESUMO

INTRODUCTION: Cognitive Testing on Computer (C-TOC) is a novel computer-based test battery developed to improve both usability and validity in the computerized assessment of cognitive function in older adults. METHODS: C-TOC's usability was evaluated concurrently with its iterative development to version 4 in subjects with and without cognitive impairment, and health professional advisors representing different ethnocultural groups. C-TOC version 4 was then validated against neuropsychological tests (NPTs), and by comparing performance scores of subjects with normal cognition, Cognitive Impairment Not Dementia (CIND) and Alzheimer disease. C-TOC's language tests were validated in subjects with aphasic disorders. RESULTS: The most important usability issue that emerged from consultations with 27 older adults and with 8 cultural advisors was the test-takers' understanding of the task, particularly executive function tasks. User interface features did not pose significant problems. C-TOC version 4 tests correlated with comparator NPT (r=0.4 to 0.7). C-TOC test scores were normal (n=16)>CIND (n=16)>Alzheimer disease (n=6). All normal/CIND NPT performance differences were detected on C-TOC. Low computer knowledge adversely affected test performance, particularly in CIND. C-TOC detected impairments in aphasic disorders (n=11). DISCUSSION: In general, C-TOC had good validity in detecting cognitive impairment. Ensuring test-takers' understanding of the tasks, and considering their computer knowledge appear important steps towards C-TOC's implementation.


Assuntos
Transtornos Cognitivos/diagnóstico , Cognição/fisiologia , Demência/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Envelhecimento , Transtornos Cognitivos/fisiopatologia , Demência/fisiopatologia , Diagnóstico Precoce , Função Executiva/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos
17.
Nanotechnology ; 26(1): 015702, 2015 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-25484106

RESUMO

Using the conductive tip of an atomic force microscope as an electrode, we found that the electrical conductance of graphite terraces separated by steps can vary by large factors of up to 100, depending on the relative lattice orientation of the surface and subsurface layers. This effect can be attributed to interlayer interactions that, when stacked commensurately in a Bernal sequence (ABAB...), cause the band gap to open. Misaligned layers, on the other hand, behave like graphene. Angular misorientations of a few degrees were found to cause large increases in the conductance of the top layer, with the maximum occurring around 30°. These results suggest new applications for graphene multilayers by stacking layers at various angles to control the resistance of the connected graphene ribbons in devices.

18.
Nanotechnology ; 26(13): 135707, 2015 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-25765817

RESUMO

The relation between surface structure and friction and adhesion is a long-standing question in tribology. Tuning the surface structure of the exposed facets of metal nanoparticles is enabled by shape control. We investigated the effect of the shape of Au nanoparticles on friction and adhesion. Two nanoparticle systems, cubic nanoparticles with a low-index (100) surface and hexoctahedral nanoparticles with a high-index (321) surface, were used as model nanoparticle surfaces. Atomic force microscopy was used to probe the nanoscale friction and adhesion on the nanoparticle surface. Before removing the capping layers, the friction results include contributions from both the geometric factor and the presence of capping layers. After removing the capping layers, we can see the exclusive effect of the surface atomic structure while the geometric effect is maintained. We found that after removing the capping layer, the cubic Au nanoparticles exhibited higher adhesion and friction, compared with cubes capped with layers covering 25% and 70%, respectively. On the other hand, the adhesion and friction of hexoctahedral Au nanoparticles decreased after removing the capping layers, compared with nanoparticles with capping layers. The difference in adhesion and friction forces between the bare Au surfaces and Au nanoparticles with capping layers cannot be explained by geometric factors, such as the slope of the nanoparticle surfaces. The higher adhesion and friction forces on cubic nanoparticles after removing the capping layers is associated with the atomic structure of (100) and (321) (i.e., the flat (100) surfaces of the cubic nanoparticles have a larger contact area, compared with the rough (321) surfaces of the hexoctahedral nanoparticles). This study implies an intrinsic relation between atomic structure and nanomechanical properties, with potential applications for controlling nanoscale friction and adhesion via colloid chemistry.

19.
BMC Ophthalmol ; 15 Suppl 1: 159, 2015 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-26817830

RESUMO

Although the mechanism of dry eye disease is not clearly understood, it is certain that inflammation and the immune response play a major role in determining the health of the ocular surface in dry eye patients. Accurate ocular surface characterization during the early stages of dry eye disease is critical for successful treatment, because there exists no single standard, objective test to diagnose the early phase of dry eye disease. The treatment target should be direct to prevent the perpetuation of chronic inflammation and immune responses. Numerous studies have categorized dry eye disease as an autoimmune-related inflammatory disease. However, relatively little is known about how innate immune mechanisms act following a local insult, why some patients are particularly vulnerable, and why local inflammation fails to resolve in these patients. Within this review, particular attention will be given to the very early events and corresponding defense mechanism in dry eye disease. The transition from innate to adaptive immunity will also be discussed.


Assuntos
Imunidade Adaptativa/fisiologia , Síndromes do Olho Seco/imunologia , Imunidade Inata/fisiologia , Doenças Autoimunes/imunologia , Congressos como Assunto , Túnica Conjuntiva/imunologia , Humanos , Inflamação/imunologia
20.
J Cardiovasc Electrophysiol ; 25(2): 146-53, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24118250

RESUMO

INTRODUCTION: Complex fractionated atrial electrograms (CFAEs) are a substrate modification target in patients with atrial fibrillation (AF). However, whether CFAEs can be also arrhythmogenic grounds of atrial tachycardia (AT) presenting after AF ablation remains to be determined. We investigated the relationship between CFAEs and the critical site of AT after CFAE-guided AF ablation. METHODS AND RESULTS: Seventy-two patients showing AT after pulmonary vein isolation and further CFAE-guided ablation were included. The termination sites of the 95 distinct ATs were annotated on color-coded CFAE cycle maps. Of the 95 ATs, 61 (64.2%) had a termination site at the border zone of CFAE or in a highly dense CFAE area. The cycle length (CL) of the ATs terminated in the CFAE area was significantly shorter than the CL of those terminated in the non-CFAE area. The cut-off CL for ATs terminated at the CFAE area was 270 milliseconds, with sensitivity/specificity of 70%/75%. In 67.2% of the ATs terminating at the CFAE-related area, the major termination sites were the anterior wall near the LA appendage, septum and roof, whereas the peri-mitral isthmus was the most common termination site of ATs in the non-CFAE area. CONCLUSIONS: The areas showing CFAE and their border zones were frequently associated with termination of ATs presenting after AF ablation. The mean CL of ATs originating near CFAEs was significantly shorter than that of those terminated in non-CFAE areas. The targeted CFAE areas also provided the arrhythmogenic milieu for AT developing after AF ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Atrial Ectópica/etiologia , Adulto , Idoso , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cirurgia Assistida por Computador , Taquicardia Atrial Ectópica/prevenção & controle , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA