Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Br J Anaesth ; 120(2): 361-367, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29406184

RESUMO

BACKGROUND: Previous data showed that non-invasive ventilation (NIV) applied for 3 min before tracheal intubation ensured better oxygenation compared with using a non-rebreather bag-valve-mask. We aimed to determine whether preoxygenation using NIV is effective in reducing the incidence of organ dysfunction in hypoxaemic, critically ill patients in intensive care. METHODS: A multicentre, randomised, open-label trial evaluating 100% FiO2 administered with NIV (99 patients) vs with face mask (102 patients) for 3 min before tracheal intubation. The primary endpoint was the maximal value of Sequential Organ Failure Assessment score within 7 days after intubation. RESULTS: The median (inter-quartile range) values of the maximal value of the Sequential Organ Failure Assessment score within 7 days post-intubation were not significantly different between the two randomised groups: nine (6-12) in the NIV group vs 10 (6-12) in the face mask group (P=0.65). In patients treated by NIV prior to the randomisation, there was a significant increase in the occurrence in adverse events in patients randomised to face mask [odds ratio=5.23 (1.61;16.99), P=0.0059]. CONCLUSIONS: This study failed to demonstrate any benefits of using NIV as a preoxygenation method to reduce organ dysfunction compared with usual preoxygenation in hypoxaemic, critically ill patients requiring tracheal intubation for invasive ventilation. NIV should not be discontinued for preoxygenation in the cases of patients treated by NIV before the decision to intubate. CLINICAL TRIAL REGISTRATION: NCT00472160.


Assuntos
Hipóxia/complicações , Intubação Intratraqueal/métodos , Insuficiência de Múltiplos Órgãos/prevenção & controle , Ventilação não Invasiva/métodos , Oxigênio/uso terapêutico , Idoso , Cuidados Críticos , Estado Terminal , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Insuficiência de Múltiplos Órgãos/epidemiologia , Resultados Negativos , Oxigênio/administração & dosagem , Insuficiência Respiratória/prevenção & controle
2.
Br J Anaesth ; 118(2): 223-231, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28100526

RESUMO

BACKGROUND: Several techniques exist for measuring central venous pressure (CVP) but little information is available about the accuracy of each method. The aim of this study was to compare different methods of CVP measurements in mechanically ventilated patients. METHODS: CVP was measured in mechanically ventilated patients without spontaneous breathing using four different techniques: 1) end expiratory CVP measurement at the base of the" c" wave (CVPMEASURED), chosen as the reference method; 2) CVP measurement from the monitor averaging CVP over the cardiac and respiratory cycles (CVPMONITOR); 3) CVP measurement after a transient withdrawing of mechanical ventilation (CVPNADIR); 4) CVP measurement corrected for the transmitted respiratory pressure induced by intrinsic PEEP (calculated CVP: CVPCALCULATED). Bias, precision, limits of agreement, and proportions of outliers (difference > 2 mm Hg) were determined. RESULTS: Among 61 included patients, 103 CVP assessments were performed. CVPMONITOR bias [-0.87 (1.06) mm Hg] was significantly different from those of CVPCALCULATED [1.42 (1.07), P < 0.001 and CVPNADIR (1.04 (1.29), P < 0.001]. The limits of agreement of CVPMONITOR [-2.96 to 1.21 mm Hg] were not significantly different to those of CVPNADIR (-1.49 to 3.57 mm Hg, P = 0.39) and CVPCALCULATED (-0.68 to 3.53 mm Hg, P = 0.31). The proportion of outliers was not significantly different between CVPMONITOR (n = 5, 5%) and CVPNADIR (n = 9, 9%, P = 0.27) but was greater with CVPCALCULATED (n = 16, 15%, P = 0.01). CONCLUSIONS: In mechanically ventilated patients, CVPMONITOR is a reliable method for assessing CVPMEASURED Taking into account transmitted respiratory pressures, CVPCALCULATED had a higher proportion of outliers and precision than CVPNADIR.


Assuntos
Pressão Venosa Central , Estado Terminal , Respiração Artificial , Adulto , Idoso , Determinação da Pressão Arterial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
J Antimicrob Chemother ; 71(2): 464-70, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26538503

RESUMO

OBJECTIVES: Few data are available to guide linezolid dosing during renal replacement therapy. The objective of this study was to compare the population pharmacokinetics of linezolid during continuous venovenous haemofiltration (CVVHF, 30 mL/kg/h) and continuous venovenous haemodiafiltration (CVVHDF, 15 mL/kg/h + 15 mL/kg/h). METHODS: Patients requiring linezolid 600 mg iv every 12 h and CVVHF or CVVHDF were eligible for this prospective study. Seven blood samples were collected over one dosing interval and analysed by a validated chromatographic method. Population pharmacokinetic analysis was undertaken using Pmetrics. Monte Carlo simulations evaluated achievement of a pharmacodynamics target of an AUC from 0-24 h to MIC (AUC0-24/MIC) of 80. RESULTS: Nine CVVHDF and eight CVVHF treatments were performed in 13 patients. Regimens of CVVHDF and CVVHF were similar. A two-compartment linear model best described the data. CVVHDF was associated with a 20.5% higher mean linezolid clearance than CVVHF, without statistical significance (P = 0.39). Increasing patient weight and decreasing SOFA score were associated with increasing linezolid clearance. The mean (SD) parameter estimates were: clearance (CL), 3.8 (2.2) L/h; volume of the central compartment, 26.5 (10.3) L; intercompartmental clearance constants from central to peripheral, 8.1 (12.1) L/h; and peripheral to central compartments, 3.6 (4.0) L/h. Achievement of pharmacodynamic targets was poor for an MIC of 2 mg/L with the studied dose. CONCLUSIONS: During CVVHF and CVVHDF, there is profound pharmacokinetic variability of linezolid. Suboptimal achievement of therapeutic targets occurs at the EUCAST breakpoint MIC of 2 mg/L using 600 mg iv every 12 h.


Assuntos
Antibacterianos/farmacocinética , Hemodiafiltração , Hemofiltração , Linezolida/farmacocinética , Idoso , Análise Química do Sangue , Cromatografia , Estado Terminal , Feminino , Humanos , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Estudos Prospectivos
4.
Br J Anaesth ; 116(2): 215-22, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26787790

RESUMO

BACKGROUND: Axillary vein catheterization via a distal approach is an alternative to the proximal approach to axillary/subclavian vein catheterization under ultrasound (US) guidance. The aim of this trial was to compare the two approaches. METHODS: In a randomized single-centre study, all patients requiring central vein catheterization in intensive care or the operating room were randomly assigned to proximal or distal approach groups. If catheterization failed after two attempts using the approach allocated, the non-allocated approach was used. The primary endpoint was the initial success rate of distal to compared with the proximal approach, using a non-inferiority analysis (lower limit 90% CI greater than -8% non-inferiority margin for group difference). The secondary endpoints were: overall success rates, catheter position and complications. RESULTS: 119/122 included patients were analysed (57 and 62 in the proximal and distal axillary approach groups, respectively). Primary success rates for proximal and distal sites were 87.7 and 85.5%, respectively (difference -2.2%, 90% CI [-12.5-8.1%], non-inferiority P=0.18). The proximal and distal overall success rates were 96.5 and 98.4%, respectively (difference -1.9%, 90% CI [-4.9-8.7%], non-inferiority P<0.01). Thrombogenic catheter positions were 7 (12.3%) in proximal approach group vs 19 (31.7%) in the distal approach group (P=0.01). Complications were comparable in the two groups (2 (3.3%) vs 4 (6.5%), P=0.68). CONCLUSION: In terms of absolute and overall success rates, a distal approach is not non-inferior to a proximal approach. Although associated with a more thrombogenic catheter extremity position, the distal approach can be considered as a rescue alternative after failure of a proximal approach. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01543360.


Assuntos
Veia Axilar/diagnóstico por imagem , Cateterismo Venoso Central/métodos , Ultrassonografia de Intervenção/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
Br J Anaesth ; 112(5): 835-41, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24496782

RESUMO

BACKGROUND: The link between preoperative fasting and hypovolaemia remains unclear. We tested the hypothesis that preoperative fasting does not significantly increase the proportion of patients with hypovolaemia according to transthoracic echocardiography (TTE) criteria. METHODS: Patients of ASA status I-III and without bowel preparation were included in a non-inferiority, prospective, single-centre trial. Patients underwent passive leg raising (PLR) test and TTE at admission (Day 0) and after 8 h fasting (Day 1). The primary hypothesis was that an 8 h preoperative fasting does not increase the proportion (margin=5%) of patients with a positive PLR test ('functional approach'). The secondary hypothesis was that echocardiographic filling pressures or stroke volume (margin 10%) are not affected by preoperative fasting ('static approach'). RESULTS: One hundred patients were included and 98 analysed. After an 8 h fasting, the change in the proportion of responders to PLR was -6.1% [95% confidence interval (CI)=-16.0 to 3.8] of responders to PLR test on Day 0 when compared with Day 1. Because 95% CI was strictly inferior to 5%, there was no significant increase in the proportion of PLR responders on Day 1 when compared with Day 0. The 95% CI changes of static variables were always fewer than 10%, meaning that preoperative fasting induced significantly no relevant changes in static variables. CONCLUSION: Preoperative fasting did not alter TTE dynamic and static preload indices in ASA I-III adult patients. These results suggest that preoperative fasting does not induce significant hypovolaemia. Clinical trial registration NCT 01258361.


Assuntos
Ecocardiografia/métodos , Jejum/fisiologia , Hemodinâmica/fisiologia , Hipovolemia/diagnóstico , Cuidados Pré-Operatórios/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Volume Sistólico/fisiologia
6.
Br J Anaesth ; 112(6): 1015-23, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24293326

RESUMO

BACKGROUND: The optimal resuscitation fluid for the early treatment of severe bleeding patients remains highly debated. The objective of this experimental study was to compare the rapidity of shock reversal with lactated Ringer (LR) or hydroxyethyl starch (HES) 130/0.4 at the early phase of controlled haemorrhagic shock. To assess the influence of vascular permeability in this model, we measured plasma vascular endothelial growth factor (VEGF) levels during the experiment. METHODS: Thirty-six anaesthetized and mechanically ventilated piglets were bled (<30 ml kg(-1)) to hold mean arterial pressure (MAP) at 40 mm Hg for more than 30 min and were resuscitated in two randomized groups: LR (n=14) or HES (n=14) at 1 ml kg(-1) min(-1) until MAP reached its baseline value of ±10%. MAP was maintained at its baseline value for 1 h. The time and fluid volume necessary to restore the baseline MAP value were measured. RESULTS: The time to restore the baseline MAP value of ±10% was significantly lower in the HES group (P<0.001). During the initial resuscitation phase, the infused volume was 279 (119) ml in the HES group and 1011 (561) ml in the LR group (P<0.0001). During the stabilization phase, the infused volume was 119 (124) ml in the HES group and 541 (506) ml in the LR group. Biological data and plasma VEGF levels were similar between the groups. CONCLUSIONS: Restoration of MAP was four times faster with HES than with LR in the early phase of controlled haemorrhagic shock. However, there was no evidence of increased vascular permeability.


Assuntos
Hidratação/métodos , Derivados de Hidroxietil Amido/uso terapêutico , Soluções Isotônicas/uso terapêutico , Substitutos do Plasma/uso terapêutico , Ressuscitação/métodos , Choque Hemorrágico/tratamento farmacológico , Animais , Pressão Sanguínea/efeitos dos fármacos , Permeabilidade Capilar/efeitos dos fármacos , Modelos Animais de Doenças , Derivados de Hidroxietil Amido/sangue , Distribuição Aleatória , Lactato de Ringer , Choque Hemorrágico/sangue , Suínos , Fatores de Tempo , Fator A de Crescimento do Endotélio Vascular/sangue
7.
J Crit Care ; 83: 154828, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38759580

RESUMO

PURPOSE: We aimed to identify factors associated with achieving target BL plasma concentrations and describe real world data for therapeutic drug monitoring (TDM). METHODS: A retrospective single center study was conducted. We collected data from patients admitted to ICU with at least one BL TDM. We assessed the proportion of patients attaining the recommended plasma concentrations (i.e 100%fT > 4 to 8 MIC). Univariate and multivariate analyses was performed to identify the determinants of BL target attainment. RESULTS: 156 patients were included. At the first dosing, 34% achieved target BL plasma concentrations, 50% were overdosed, and 16% were underdosed. Median time for 1st TDM were 4 (SD = 2.9) days. Multivariate analysis revealed that CKD-EPI estimated glomerular filtration rate (OR = 1.02; CI [1.01; 1.03]; p < 0.0001) and total body weight (OR = 1.03; CI [1.01; 1.04]; p = 0.0048) were the main determinant of BL target attainment. Conversely, Continuous Renal Replacement Therapy (OR = 0.28; CI [0.09; 0.89]; p = 0.0318) and meropenem use (OR = 0.31; CI [0.14; 0.69]; p = 0.0041) were identified as risk factors for overdosing. No factor was associated with underdosing. CONCLUSION: Achieving target BL plasma concentrations remains challenging in ICUs. Identifying predictive factors of BL target attainment would favor implementing rapid dosing optimization strategies in both under and overdosing high risk patients.


Assuntos
Antibacterianos , Estado Terminal , Monitoramento de Medicamentos , Unidades de Terapia Intensiva , beta-Lactamas , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Antibacterianos/farmacocinética , Antibacterianos/administração & dosagem , Antibacterianos/sangue , beta-Lactamas/farmacocinética , beta-Lactamas/administração & dosagem , beta-Lactamas/uso terapêutico , Taxa de Filtração Glomerular
8.
Anaesthesia ; 67(9): 999-1008, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22708696

RESUMO

We conducted an observational prospective multicenter study to describe the practices of mechanical ventilation, to determine the incidence of use of large intra-operative tidal volumes (≥10 ml.kg(-1) of ideal body weight) and to identify patient factors associated with this practice. Of the 2960 patients studied in 97 anaesthesia units from 49 hospitals, volume controlled mode was the most commonly used (85%). The mean (SD) tidal volume was 533 (82) ml; 7.7 (1.3) ml.kg(-1) (actual weight) and 8.8 (1.4) ml.kg(-1) (ideal body weight)). The lungs of 381 (18%) patients were ventilated with a tidal volume>10 ml.kg(-1) ideal body weight. Being female (OR 5.58 (95% CI 4.20-7.43)) and by logistic regression, underweight (OR 0.06 (95% CI 0.01-0.45)), overweight (OR 1.98 (95% CI 1.49-2.65)), obese (OR 5.02 (95% CI 3.51-7.16)), severely obese (OR 10.12 (95% CI 5.79-17.68)) and morbidly obese (OR 14.49 (95% CI 6.99-30.03)) were the significant (p ≤ 0.005) independent factors for the use of large tidal volumes during anaesthesia.


Assuntos
Manuseio das Vias Aéreas/métodos , Anestesia Geral , Peso Corporal/fisiologia , Cuidados Intraoperatórios/métodos , Volume de Ventilação Pulmonar/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Feminino , França , Humanos , Insuflação , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva , Estudos Prospectivos , Respiração Artificial , Testes de Função Respiratória
9.
Br J Anaesth ; 106(3): 336-43, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21205626

RESUMO

BACKGROUND: Pain management is challenging in intensive care unit (ICU) patients. The analgesic efficacy, tolerance, and haemodynamic effects of nefopam have never been described in critically ill patients. METHODS: In consecutive medical-surgical ICU patients who received 20 mg of nefopam i.v. over 30 min, we measured pain, Richmond Agitation Sedation Scale (RASS), respiratory parameters, and adverse drug events at T0 (baseline), T30 (end-of-infusion), T60, and T90 min. Haemodynamic variables were assessed every 15 min from T0 to T60 and T90. Pain was evaluated by the behavioural pain scale (BPS, 3-12) or by the self-reported visual numeric rating scale (NRS, 0-10) according to communication capacity. RESULTS: Data were analysed for 59 patients. As early as T30, median NRS and BPS decreased significantly from T0 to a minimum level at T60 for NRS [5 (4-7) vs 1 (1-3), P<0.001] and T90 for BPS [5 (5-6) vs 3 (3-4), P<0.001]. No significant changes were detected for RASS, ventilatory frequency, or oxygen saturation. Increased heart rate and decreased mean arterial pressure, defined as a change ≥15% from baseline, were found in 29% and 27% of patients, respectively. For the 18 patients monitored, cardiac output increased by 19 (7-29)% and systemic vascular resistance decreased by 20 (8-28)%, both maximally at T30. Heat sensation, nausea/vomiting, sweating, and mouth dryness were found, respectively, in 6%, 9%, 22%, and 38% of patients. CONCLUSIONS: A single slow infusion of nefopam is effective in critically ill patients who have moderate pain. The risk of tachycardia and increased cardiac output and also hypotension and decreased systemic vascular resistance should be known to evaluate the benefit/risk ratio of its prescription.


Assuntos
Analgésicos não Narcóticos/uso terapêutico , Estado Terminal/terapia , Nefopam/uso terapêutico , Dor/tratamento farmacológico , Analgésicos não Narcóticos/administração & dosagem , Analgésicos não Narcóticos/efeitos adversos , Débito Cardíaco/efeitos dos fármacos , Cuidados Críticos/métodos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Nefopam/administração & dosagem , Nefopam/efeitos adversos , Medição da Dor/métodos , Estudos Prospectivos
10.
Anaesth Crit Care Pain Med ; 37(3): 201-205, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28826982

RESUMO

OBJECTIVE: Ensuring the availability of ultrasound devices is the initial step in implementing clinical ultrasound (CUS) in emergency services. In France in 2011, 52% of emergency departments (EDs) and only 9% of mobile intensive care stations (MICS) were equipped with ultrasound devices. The main goal of this study was to determine the movement of these rates since 2011. METHODS: We conducted a cross-sectional, descriptive, multicentre study in the form of a questionnaire. To estimate the numbers of EDs and MICS equipped with at least one ultrasound system with a confidence level of 95% and margin of error of 5%, 170 responding EDs and 145 MICS were required. Each service was solicited three times by secure online questionnaire and then by phone. RESULTS: Three hundred and twenty-eight (84%) services responded to the questionnaire: 179 (86%) EDs and 149 (82%) MICS. At least one ultrasound machine was available in 127 (71%, 95% CI [64; 78]) EDs vs. 52% in 2011 (P<0.01). 42 (28%, 95% CI [21; 35]) MICS were equipped vs. 9% in 2011 (P<0.01). In 97 (76%) EDs and 24 (55%) MICS, less than a half of physicians were trained. CUS was used at least three times a day in 52 (41%) EDs and in 8 (19%) MICS. CONCLUSION: Our study demonstrates improved access to ultrasound devices in French EDs and MICS. Almost three-quarters of EDs and nearly one-third of MICS are now equipped with at least one ultrasound device. However, the rate of physicians trained per service remains insufficient.


Assuntos
Serviços Médicos de Emergência/tendências , Serviço Hospitalar de Emergência/tendências , Testes Imediatos/tendências , Ultrassonografia/tendências , Estudos Transversais , Serviços Médicos de Emergência/estatística & dados numéricos , Serviço Hospitalar de Emergência/estatística & dados numéricos , França , Pesquisas sobre Atenção à Saúde , Acessibilidade aos Serviços de Saúde , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Testes Imediatos/estatística & dados numéricos , Inquéritos e Questionários , Ultrassonografia/instrumentação , Ultrassonografia/estatística & dados numéricos
11.
Transfus Clin Biol ; 24(2): 47-51, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28214244

RESUMO

BACKGROUND: In France, blood group determination requires the completion of two samples collected at two different times to detect identity mistake and "wrong blood in tube". The aims of the present study were: (1) to evaluate the compliance with guidelines and (2) to identify risk factors of non-compliance. MATERIALS AND METHODS: Samples for ABO group determination collected between January 1st and December 15th, 2013 in the University hospital of Nîmes, France were analyzed. An ABO group determination demand was considered non-compliant if more than one tube arrived in the laboratory within ten minutes apart. Between May 1st and June 30th 2014, a self-administered questionnaire was offered to the nurses of the hospital on a random day for each service during this period. The aim was to validate the non-compliance criterion and the identification of risk factors using logistic regression. RESULTS: Among the 16,450 analyzed blood samples, the overall compliance rate was 65.1%. Lower compliance rates were found in the surgical services. Independent risk factors for wrong practice were work overload, surgical service and individual intermediate transfusion frequency. DISCUSSION: More than one third of ABO group determinations did not follow national recommendations, which induces a substantial risk of "wrong blood in tube" and group error. The study revealed major variations among hospital services. Identification of risk factors allows targeted corrective actions.


Assuntos
Tipagem e Reações Cruzadas Sanguíneas/normas , Transfusão de Sangue/normas , Fidelidade a Diretrizes/estatística & dados numéricos , Erros Médicos/estatística & dados numéricos , Tipagem e Reações Cruzadas Sanguíneas/estatística & dados numéricos , Transfusão de Sangue/estatística & dados numéricos , Análise Fatorial , França , Humanos , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco
12.
Ann Fr Anesth Reanim ; 25(2): 180-8, 2006 Feb.
Artigo em Francês | MEDLINE | ID: mdl-16226862

RESUMO

OBJECTIVE: Central venous catheter (CVC) insertion is routinely performed in critically ill patients but causes mechanical, thrombotic, or infectious adverse events in 15% of cases. It should be possible to improve the benefit/risk ratio of central venous catheterization in intensive care unit. DATA SOURCE: We searched Pubmed using the terms: "catheterization, central venous, peripheral, adverse effects"; then "thrombosis, phlebitis, thrombophlebitis, jugular vein, femoral vein, subclavian vein, pneumothorax, haemothorax, extravasation of diagnostic and therapeutic materials". We then discuss this with a panel of intensivists in a workshop. DATA SYNTHESIS: Few data are available on the risk/benefit ratio of central vs. peripheral venous catheterization. In some cases (cardiac arrest, rapid fluid loading, parenteral nutrition) the choice is based on clear recommendations. In others (irritating drugs, pressure monitoring, peripheral access failure), the choice depends on medical and nurses daily evaluation. When CVC insertion is mandatory, it is important to implement the recommendations of the consensus conferences to prevent infectious and thrombotic complications. Mechanical complications should be improved by selecting the most appropriate insertion site, and, if unsuccessful, switching to another operator before the complications occurs. Doppler-ultrasound guidance is recommended, but is limited by the cost and training of the technique. CONCLUSION: Studies evaluating the risk/benefit ratio of CVCs versus peripheral catheters are needed to develop a venous-access strategy for ICU patients. When a CVC is mandatory, recent data are available to improve the risk/benefit ratio and can be used to build a decision algorithm.


Assuntos
Cateterismo Venoso Central/métodos , Unidades de Terapia Intensiva , Cateterismo Venoso Central/efeitos adversos , Cateterismo Periférico/efeitos adversos , Cuidados Críticos , Tomada de Decisões , Humanos , Medição de Risco , Ultrassonografia Doppler , Doenças Vasculares/prevenção & controle
13.
Ann Fr Anesth Reanim ; 25(7): 696-701, 2006 Jul.
Artigo em Francês | MEDLINE | ID: mdl-16698231

RESUMO

OBJECTIVE: To test reliability of the Richmond Agitation Sedation Scale (RASS) after French translation. STUDY DESIGN: Prospective psychomotor evaluation study. PATIENTS AND METHODS: Two bilingual physicians performed the translation from English to French language. The French version was then translated to English by a bilingual non physician ("backtranslation") and compared to the original version. The translated scale was tested according to usual guidelines concerning the translation of neuropsychological evaluation tools. The French version of RASS was tested on the morning of every fifth or sixth day, and 30-min after any procedure, in 43 consecutive patients admitted to a 12-bed medical-surgical intensive care unit during two months, by a group of four observers: the principal investigator, two anaesthesiology residents and one pharmacology student. Inter-rater reliability was tested using the simple and weighted Kappa coefficients (with their 95% confidence interval). A consensual and detailed "operating instructions" guide of RASS, intended for medical and nursing staff, has been added in the Annexe section. RESULTS: Four hundred twenty measures were performed during 105 grouped observations. Reliability of the French version of RASS was substantial. Simple Kappa coefficient, testing the concordance between observers, was ranged from 0.72 (0.62-0.81) to 0.87 (0.79-0.94) and weighted Kappa coefficient from 0.95 (0.92-0.98) to 0.99 (0.98-0.99). CONCLUSIONS: The French translation of RASS was acceptable. The translated scale preserved substantial inter-rater reliability. Monitoring of vigilance status in intensive care settings can be performed with this reliable clinical tool.


Assuntos
Nível de Alerta/fisiologia , Testes Neuropsicológicos/normas , Agitação Psicomotora/psicologia , Idoso , Feminino , França , Humanos , Idioma , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Estudos Prospectivos , Reprodutibilidade dos Testes
14.
Ann Fr Anesth Reanim ; 25(5): 493-500, 2006 May.
Artigo em Francês | MEDLINE | ID: mdl-16488102

RESUMO

OBJECTIVES: Assessment of relationship between general practitioners and intensivists. STUDY DESIGN: Intensivists were questioned by phone from June 14th to September 28th 2004. METHODS: 245 out of 264 intensivists from 8 French Southern regional areas were questioned concerning their relationship with critically ill patients' general practitioner. RESULTS: Patients were mainly admitted into Intensive care Unit (ICU) from the Emergency Department (55%). An information letter from the general practitioner was reported for 20% of admitted patients but 50% of these letters was assumed as not informative. The informations concerning the patient's medical history, therapies, and disease leading to admission and the patient's status were assessed with 6.5, 7.0, 6.0 and 2.0, respectively (maximal note=10). The intensivists contacted the general practitioner for 30% of admitted patients. During the stay in ICU, 33% general practitioners were reported to request informations by phone or visit in ICU. When the stay in ICU was>10 days, the general practitioner was nearly never regularly informed about patient's status. When the patient was discharged from the ICU, 80% of intensivists used an exhaustive typed report to inform the general practitioner. The overall relationship between the general practitioner and the intensivist was assessed as 5.5/10. Insufficient information in the general practitioner's letter at admission, the lack of request for information during the stay in ICU, the lack of contact with the general practitioner by the intensivist and an intensivist's age between 46 and 55 were associated with a relationship assessment<4/10).


Assuntos
Anestesiologia , Relações Interprofissionais , Médicos de Família , Adulto , Comunicação , Cuidados Críticos , Feminino , França , Humanos , Entrevistas como Assunto , Masculino , Prontuários Médicos , Serviço Hospitalar de Registros Médicos , Pessoa de Meia-Idade , Equipe de Assistência ao Paciente , Alta do Paciente , Médicos de Família/psicologia
15.
Ann Fr Anesth Reanim ; 24(3): 291-3, 2005 Mar.
Artigo em Francês | MEDLINE | ID: mdl-15792566

RESUMO

In order to decrease the risks of colonisation and infection of central venous catheters, their impregnation has been suggested using anti-infectious agents (antiseptic, antibiotic, silver). Many methodological flaws and contradictory results have been reported in the published trials. The use of impregnated catheter should only be discussed when the issues of anatomic site and type of insertion of the catheter have been adequately addressed.


Assuntos
Antibacterianos , Anti-Infecciosos Locais , Cateterismo/efeitos adversos , Infecção Hospitalar/prevenção & controle , Ensaios Clínicos como Assunto , Humanos , Prata
16.
Intensive Care Med ; 28(8): 1036-41, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12185422

RESUMO

OBJECTIVE: To identify the risk factors of failure and immediate complication of subclavian vein catheterization (SVC). DESIGN: Prospective observational study. SETTING: Surgical critical care unit of a tertiary university hospital. PATIENTS: Critically ill patients requiring a first SVC. INTERVENTION: Subclavian vein catheterization was attempted in 707 patients without histories of surgery or radiotherapy in the subclavian area. Failed catheterizations, arterial punctures, pneumothoraces and misplacements of the catheter tip were recorded. Risk factors of failure and immediate complication were isolated among patients' characteristics, procedure parameters (side and number of venipunctures) and the operator's experience using a univariate +/- multivariate analysis. MEASUREMENTS AND MAIN RESULTS: Five hundred sixty-two SVCs (79.5%) were achieved without adverse events. Among the remaining 145 catheterizations, 67 (9.5%) failures, 55 (7.8%) arterial punctures, 22 (3.1%) pneumothoraces and 30 (4.2%) misplacements of the catheter tip occurred. More than one venipuncture was the only risk factor of failed catheterization [2 venipunctures, odds ratio =7.4 (2.1-26); >2 venipunctures, odds ratio =49.1 (16.8-144.1)]. More than one venipuncture and age 77 years or more were predictive of the occurrence of immediate complications [2 venipunctures, odds ratio =3.6 (1.8-7.0); >2 venipunctures, odds ratio =14 (7.7-25.3); age >or=77, odds ratio =1.8 (1.0-3.1)]. The operator's training was not predictive of failed catheterization or immediate complication. CONCLUSION: For SVC, more than one venipuncture is predictive of failed catheterization and immediate complication. Age 77 years or more was predictive of immediate complications.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Cuidados Críticos/normas , Unidades de Terapia Intensiva/normas , Veia Subclávia , Adolescente , Adulto , Idoso , Cuidados Críticos/métodos , Estado Terminal , Feminino , França , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Fatores de Risco , Falha de Tratamento
17.
Intensive Care Med ; 26(6): 693-7, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10945385

RESUMO

OBJECTIVE: Comparison of suprasternal Doppler (SST) and thermodilution (TD) for the measurement of cardiac output (CO) in critically ill patients. DESIGN: Prospective study. SETTING: Intensive care unit of a university hospital. PATIENTS AND PARTICIPANTS: 65 consecutive critically ill patients requiring a pulmonary artery catheter. INTERVENTIONS: Paired CO measurements were made simultaneously using SST and TD by two independent operators. The time to obtain a CO value by SST was measured. Correlation coefficients and the linear regression equation were determined. A Bland and Altman diagram was plotted. A Bland and Altman diagram was also plotted for the level of cardiac index (CI) values (low: CI < 2.5 l min(-1) m(-2); normal: 2.5 < or = CI < or = 4.5 l min(-1) m(-2); high: CI > 4.5 l min(-1) m(-2)). MEASUREMENTS AND RESULTS: In seven patients SST failed to measure CO. In the remaining 58 patients 314 paired CO measurements were performed. The mean time to measure CO by SST was 73 +/- 45 s. The equation of linear regression was: SST(CO) = 0.84 TD(CO) + 1.39. The correlation coefficient was 0.84. The bias between SST and TD was -0.2 +/- 1.4 l min(-1). Biases were -0.23 +/- 0.50, -0.20 +/- 0.68, and 0.25 +/- 0.92 l min(-1) m(-2) for low, normal, and high levels of CI, respectively. CONCLUSION: SST does not accurately measure CO but allows a rapid assessment of CI level in critically ill patients.


Assuntos
Débito Cardíaco , Ecocardiografia Doppler/métodos , Unidades de Terapia Intensiva , Termodiluição , Adulto , Feminino , Hemodinâmica , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Pancreatite/diagnóstico , Cuidados Pós-Operatórios , Estudos Prospectivos , Choque Séptico/diagnóstico
18.
Intensive Care Med ; 29(3): 414-8, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12577157

RESUMO

OBJECTIVE: Comparisons of urinary bladder, oesophageal, rectal, axillary, and inguinal temperatures versus pulmonary artery temperature. DESIGN: Prospective cohort study. SETTING: Intensive Care Unit of a University-Hospital. PATIENTS: Forty-two intensive care patients requiring a pulmonary artery catheter (PAC). INTERVENTION: Patients requiring PAC and without oesophageal, urinary bladder, and/or rectal disease or recent surgery were included in the study. Temperature was simultaneously monitored with PAC, urinary, oesophageal, and rectal electronic thermometers and with axillary and inguinal gallium-in-glass thermometers. Comparisons used a Bland and Altman method. MEASUREMENTS AND MAIN RESULTS: The pulmonary arterial temperature ranged from 33.7 degrees C to 40.2 degrees C. Urinary bladder temperature was assessed in the last 22 patients. A total of 529 temperature measurement comparisons were carried out (252 comparisons of esophageal, rectal, inguinal, axillary, and pulmonary artery temperature measurements in the first 20 patients, and 277 comparisons with overall methods in the last patients). Nine to 18 temperature measurement comparisons were carried out per patient (median = 13). The mean differences between pulmonary artery temperatures and those of the different methods studied were: oesophageal (0.11+/-0.30 degrees C), rectal (-0.07+/-0.40 degrees C), axillary (0.27+/-0.45 degrees C), inguinal (0.17+/-0.48 degrees C), urinary bladder (-0.21+/-0.20 degrees C). CONCLUSION: In critically ill patients, urinary bladder and oesophageal electronic thermometers are more reliable than the electronic rectal thermometer which is better than inguinal and axillary gallium-in-glass thermometers to measure core temperature.


Assuntos
Temperatura Corporal/fisiologia , Cuidados Críticos , Artéria Pulmonar/fisiologia , Idoso , Axila/fisiologia , Esôfago/fisiologia , Feminino , Humanos , Canal Inguinal/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reto/fisiologia , Termômetros , Bexiga Urinária/fisiologia
19.
Intensive Care Med ; 24(4): 347-52, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9609413

RESUMO

OBJECTIVES: Assessment of and effect of training on reliability of esophageal Doppler (ED) versus thermodilution (TD) for cardiac output (CO) measurement. DESIGN: Prospective study. SETTING: Intensive care unit of a university hospital. PATIENTS: 64 consecutive critically ill patients requiring a pulmonary artery catheter, sedation, and mechanical ventilation. INTERVENTIONS: Esophageal Doppler CO measurements were performed by the same operator, whereas TD CO measurements were carried out by other independent operators. A training period involving the first 12 patients made the operator self-confident. In the remaining patients, the reliability of ED was assessed (evaluation period), using correlation coefficients and the Bland and Altman diagram. Between training and evaluation periods, correlation coefficients, biases, and limits of agreement were compared. MEASUREMENTS AND RESULTS: During training and evaluation periods, 107 and 320 CO measurements were performed in 11 out of 12 patients and in 49 out of 52 patients, respectively. Continuous CO monitoring was achieved in 6 out of 11 patients and in 38 out of 49 patients during training and evaluation periods, respectively. Between the two periods, correlation coefficients increased from 0.53 to 0.89 (p < 0.001), bias decreased from 1.2 to 0.1 l x min(-1) (p < 0.001), and limits of agreement decreased from 3.2 to 2.2 l x min(-1) (p < 0.001). CONCLUSION: A period of training involving no more than 12 patients is probably required to ensure reliability of CO measurement by ED.


Assuntos
Débito Cardíaco , Competência Clínica/normas , Ecocardiografia Doppler/normas , Ecocardiografia Transesofagiana/normas , Recursos Humanos em Hospital/educação , Termodiluição/normas , Idoso , Viés , Cuidados Críticos , Estado Terminal , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
20.
J Clin Pharmacol ; 41(1): 44-50, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11144993

RESUMO

The authors have studied 10 critically ill patients with acute respiratory distress syndrome who required a neuromuscular blocking drug to assist mechanical ventilation. Patients received a bolus dose of 1 mg/kg of atracurium followed by a constant infusion rate of 1 mg/kg/h of this drug for 72 hours. Neuromuscular block was monitored using an accelerograph. Blood samples were obtained over a 96-hour period. A preliminary independent analysis was done to estimate the individual pharmacokinetic parameters; data were consistent with a one-compartment model. The pharmacodynamic data analysis was then performed using the changes in train-of-four (TOF) count as an index of the therapeutic effect of atracurium. Pharmacokinetic-dynamic variables were calculated using the Sheiner model and the Hill equation. The elimination half-life of atracurium averaged 22 minutes. Mean volume of distribution and plasma clearance were 217 ml/kg and 550 ml/min, respectively. There was a significant hysteresis loop when the TOF count was plotted against predicted plasma atracurium concentrations. The mean sigmoidicity factor, gamma, was 4.04. The concentration producing 50% of the Emax was 1.36 micrograms/mL, and the mean ke0 was 0.059 min-1. Recovery time ranged from 30 to 80 minutes, and none of the patients of this study had residual paralysis.


Assuntos
Atracúrio/farmacocinética , Modelos Biológicos , Fármacos Neuromusculares não Despolarizantes/farmacocinética , Síndrome do Desconforto Respiratório/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Atracúrio/sangue , Atracúrio/farmacologia , Estado Terminal , Esquema de Medicação , Humanos , Infusões Intravenosas , Isoquinolinas/farmacocinética , Pessoa de Meia-Idade , Fármacos Neuromusculares não Despolarizantes/sangue , Fármacos Neuromusculares não Despolarizantes/farmacologia , Respiração Artificial , Síndrome do Desconforto Respiratório/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA