Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Jt Comm J Qual Patient Saf ; 41(3): 108-14, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25977126

RESUMO

BACKGROUND: The safety profile of anticoagulants, which are being used with increasing frequency in pediatric populations, is not well studied. Automatic triggers built into electronic health record systems (EHR) have been shown to be an effective way to monitor for and identify medication errors. Anticoagulant-associated adverse events were examined through the use of an anticoagulant trigger panel. METHODS: In a retrospective, five-year (September 2007-September 2012) observational study, four automated triggers were used to detect anticoagulant-related adverse events: activated partial thromboplastin time (aPTT) > 100 seconds in patients on an unfractionated heparin (UFH) infusion, International Normalized Ratio (INR) > 4, anti-factor Xa (anti-FXa) >1.5U/mL for patients on enoxaparin, and the documented use of protamine. RESULTS: For the 1,664 triggers evaluated, 12 were associated with the aPTT trigger, only 1 of which was preventable. Receiver operator characteristic curve analysis indicated that increasing the aPTT trigger > 140 seconds would optimize sensitivity and specificity. The INR trigger identified four outpatients with adverse events. No adverse events were associated with the anti-FXa trigger. The protamine trigger identified 12 adverse events and was associated with more severe events. Minimal overlap was found with protamine and aPTT triggers. CONCLUSION: Laboratory- and medication-based triggers can be effective monitoring tools for anticoagulants. For patients receiving a UFH infusion, an aPTT cutoff value of > 140 seconds is more precise. We also found that protamine use as a trigger adds value to a trigger-based anticoagulant monitoring system. Continued improvement in the logic algorithms associated with the EHR-based trigger tool will allow expanded use of this tool in a clinical manner.


Assuntos
Anticoagulantes/efeitos adversos , Monitoramento de Medicamentos/métodos , Registros Eletrônicos de Saúde/organização & administração , Hospitais Pediátricos/organização & administração , Erros de Medicação/efeitos adversos , Humanos , Coeficiente Internacional Normatizado , Tempo de Tromboplastina Parcial , Qualidade da Assistência à Saúde , Estudos Retrospectivos
2.
Pediatrics ; 135(6): 1036-42, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25986015

RESUMO

OBJECTIVES: An efficient and reliable process for measuring harm due to medical care is needed to advance pediatric patient safety. Several pediatric studies have assessed the use of trigger tools in varying inpatient environments. Using the Institute for Healthcare Improvement's adult-focused Global Trigger Tool as a model, we developed and pilot tested a trigger tool that would identify the most common causes of harm in pediatric inpatient environments. METHODS: After formal training, 6 academic children's hospitals used this novel pediatric trigger tool to review 100 randomly selected inpatient records per site from patients discharged during the month of February 2012. RESULTS: From the 600 patient charts evaluated, 240 harmful events ("harms") were identified, resulting in a rate of 40 harms per 100 patients admitted and 54.9 harms per 1000 patient days across the 6 hospitals. At least 1 harm was identified in 146 patients (24.3% of patients). Of the 240 total events, 108 (45.0%) were assessed to have been potentially or definitely preventable. The most common patient harms were intravenous catheter infiltrations/burns, respiratory distress, constipation, pain, and surgical complications. CONCLUSIONS: Consistent with earlier rates of all-cause harm in adult hospitals, harm occurs at high rates in hospitalized children. Availability and use of an all-cause harm identification tool will establish the epidemiology of harm and will provide a consistent approach to assessing the effect of interventions on harms in hospitalized children.


Assuntos
Erros Médicos/prevenção & controle , Segurança do Paciente , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Pacientes Internados , Masculino
3.
Pediatr Clin North Am ; 59(6): 1269-78, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23116524

RESUMO

Voluntary reporting has been the standard method for identifying adverse events in hospitals, yet its effectiveness at identifying a comprehensive array of adverse events has always been in question. The electronic health record (EHR) contains clinical data that can be systematically reviewed to identify adverse events and improve adverse event detection. Active use of an automated trigger tool that is embedded in an EHR can identify systematic issues with delivery of high-risk medications and is cost-effective and efficient. Further development of an automated adverse event detection protocol for pediatrics is needed to apply this approach systematically across pediatric institutions.


Assuntos
Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/diagnóstico , Registros Eletrônicos de Saúde , Erros Médicos , Segurança do Paciente , Criança , Humanos , Qualidade da Assistência à Saúde , Gestão da Segurança/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA