RESUMO
INTRODUCTION: Chronic kidney disease (CKD) in stages 3-5 without albuminuria occurs more often in women than in men; however, most patients initiating and receiving kidney replacement therapy are men. Sex-determined biological factors and gender-related aspects both likely account for this discrepancy. Patient opinions on gender-related discrepancies in kidney care have not been investigated. METHODS: Building upon the findings of semi-structured interviews previously conducted with CKD patients and their caregivers, two questionnaires were developed to investigate patient behavior and opinions relating to gender and CKD. These questionnaires containing 39 items were distributed to eight outpatient clinics in Austria. Responses were descriptively analyzed and compared between genders, as well as between age-groups and CKD stages. RESULTS: Questionnaires from 783 patients and 98 caregivers were included in the analysis and covered health awareness and self-management of disease, the impact of gender roles and gender equality, and patient autonomy and trust in the health-care system. A total of 56.1% of men patients and 63.1% of women patients found that women were better at looking after their health compared to men (41.1%/34.3% no difference, 2.8%/2.6% men better). A total of 95.4% of men patients, 95.0% of women patients, 100% of men caregivers, and 95.5% of women caregivers stated that all patients with kidney disease were treated completely equally, irrespective of gender. CONCLUSION: Neither the patients nor the caregivers stated gender-determined treatment decisions in CKD care. Both men and women however agreed that women are better at maintaining their own health and excel in disease self-management.
Assuntos
Cuidadores , Insuficiência Renal Crônica , Humanos , Masculino , Feminino , Cuidadores/psicologia , Cuidadores/estatística & dados numéricos , Pessoa de Meia-Idade , Idoso , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/psicologia , Inquéritos e Questionários , Adulto , Fatores Sexuais , Idoso de 80 Anos ou mais , Entrevistas como Assunto , Áustria/epidemiologia , Conhecimentos, Atitudes e Prática em SaúdeRESUMO
The aim of the study was to systematically review evidence on the effectiveness and safety of oral mexiletine administered in monotherapy or in combination with other antiarrhythmic drugs for recurrent ventricular arrhythmia (ventricular tachycardia/ventricular fibrillation, VT/VF) in adult patients with structural heart disease (SHD) and implantable cardioverter defibrillators (ICDs). We systematically searched MEDLINE, Embase, and CENTRAL databases from inception to 27 August 2021 for prospective and retrospective studies investigating mexiletine in the target population. The main outcome was the reduction of ICD therapy. The main safety outcome was the presence of any serious adverse events (SAEs) leading to mexiletine discontinuation. Study quality was assessed using the Cochrane risk of bias tool or the Newcastle-Ottawa scale. Four studies comprising 86 mexiletine recipients were included in the review. We also obtained individual data of 50 patients from two studies. Ischaemic cardiomyopathy (ICM) was present in 86% of patients. The quality of included studies was moderate/low. A narrative review was undertaken as studies varied widely in terms of study population and treatment. Across studies, mexiletine treatment (with or without amiodarone) seemed to consistently reduce the number of ICD therapies especially in a population where catheter ablation (CA) was unsuccessful or contraindicated. In ICM patients deemed eligible for CA, mexiletine seemed to be inferior to CA. Mexiletine was discontinued in 14% of cases, mainly for gastrointestinal or neurological SAE. Mexiletine seems to be an option for the long-term treatment of recurrent VT/VF in adult patients with SHD, especially ICM, and ICD in whom CA was unsuccessful or not suitable.
Assuntos
Amiodarona , Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Adulto , Antiarrítmicos/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Humanos , Mexiletina/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/terapia , Resultado do Tratamento , Fibrilação VentricularRESUMO
BACKGROUND: Young implantable cardioverter defibrillator (ICD) recipients have a high rate of complications, some of which seem to be underestimated. We report our clinical experience with ICD therapy in children and young adults during a 15 year follow up. METHODS: We reviewed the database of ICD recipients at the present institution and chose 73 consecutive patients who underwent implantation at age 6-21 years. We analyzed intervention rate, mortality, rate and characteristics of complications and treatment options. RESULTS: A total of 20/73 patients (27.4%) received ≥1 episode of appropriate therapy (AT) for ventricular tachycardia/ventricular fibrillation (anti-tachycardia pacing or shock) and 24/73 patients (32.8%) had one or multiple episodes of inappropriate therapy (IT). Eight patients (11%) had both interventions: AT + IT. A total of 15/73 patients (20.5%) had ventricular lead dysfunction, with 13 re-implantations (17.8%) of a new system. Four of 73 patients (5.5%) had infection: endocarditis or device pocket infection. A total of 2/73 patients (2.7%) died due to ventricular lead dysfunction, while 22/73 patients (30.1%) needed elective device replacement, five of them twice (6.8%). CONCLUSION: Endocardial ICD implantation in children and young adults is a feasible and life-saving procedure, according to the present 15 year follow up. The rate of complications including IT was high: 72.8% in the young ICD recipients. Re-implantation of a new system was often required due to ventricular lead dysfunction or infection in 25% of the patients.
Assuntos
Desfibriladores Implantáveis/efeitos adversos , Cardiopatias/terapia , Adolescente , Criança , Feminino , Seguimentos , Cardiopatias/mortalidade , Humanos , Masculino , Resultado do Tratamento , Adulto JovemRESUMO
Image acquisition is an important step in the study of cytoskeleton organization. As visual interpretations and manual measurements of digital images are prone to errors and require a great amount of time, a freely available software package named MicroFilament Analyzer (MFA) was developed. The goal was to provide a tool that facilitates high-throughput analysis to determine the orientation of filamentous structures on digital images in a more standardized, objective and repeatable way. Here, the rationale and applicability of the program is demonstrated by analyzing the microtubule patterns in epidermal cells of control and gravi-stimulated Arabidopsis thaliana roots. Differential expansion of cells on either side of the root results in downward bending of the root tip. As cell expansion depends on the properties of the cell wall, this may imply a differential orientation of cellulose microfibrils. As cellulose deposition is orchestrated by cortical microtubules, the microtubule patterns were analyzed. The MFA program detects the filamentous structures on the image and identifies the main orientation(s) within individual cells. This revealed four distinguishable microtubule patterns in root epidermal cells. The analysis indicated that gravitropic stimulation and developmental age are both significant factors that determine microtubule orientation. Moreover, the data show that an altered microtubule pattern does not precede differential expansion. Other possible applications are also illustrated, including field emission scanning electron micrographs of cellulose microfibrils in plant cell walls and images of fluorescent actin.
Assuntos
Citoesqueleto de Actina/metabolismo , Arabidopsis/metabolismo , Microscopia Confocal/instrumentação , Microtúbulos/metabolismo , Software , Citoesqueleto de Actina/ultraestrutura , Actinas/metabolismo , Actinas/ultraestrutura , Arabidopsis/fisiologia , Arabidopsis/ultraestrutura , Proteínas de Arabidopsis/metabolismo , Proteínas de Arabidopsis/ultraestrutura , Gravitropismo , Meristema/metabolismo , Meristema/fisiologia , Meristema/ultraestrutura , Microscopia Confocal/métodos , Microtúbulos/ultraestrutura , Epiderme Vegetal/metabolismo , Epiderme Vegetal/fisiologia , Epiderme Vegetal/ultraestrutura , Raízes de Plantas/metabolismo , Raízes de Plantas/fisiologia , Raízes de Plantas/ultraestrutura , Brotos de Planta/metabolismo , Brotos de Planta/fisiologia , Brotos de Planta/ultraestrutura , Plantas Geneticamente Modificadas , Proteínas Recombinantes de FusãoRESUMO
BACKGROUND: Chronic kidney disease (CKD) affects more women than men worldwide, however, men comprise the majority of patients who receive kidney replacement therapy. We aimed to describe the perspectives of patients and their caregivers regarding gender disparities in CKD. METHODS: Semi-structured interviews were conducted with 45 patients with CKD (20 women) and 14 caregivers (12 women) from seven clinics in Austria. The interviews were analyzed thematically. RESULTS: Five themes were identified in this study. Participants perceived that women were "disadvantaged and vulnerable" (silent and intimidated, single mother predicament, impeded access to care and support due to socioeconomic disadvantage, had to fend for themselves); "fulfilling gender roles and norms" (primarily responsible for childcare, pressure to perform well as homemakers, put others' needs before their own, encouraging husband's treatment adherence), and "protecting their own health" (self-disciplined, vigilant, confronted health challenges, advocated for their needs). Men were seen to "place the onus of care on others" (expected help from family, relied on others for decisions). Both men and women experienced a "disease-related identity crisis and distress" (women: impaired body image, mental distress; men: denial and self-destruction, emasculated by sickness). CONCLUSIONS: Women with CKD felt vulnerable and were inclined to fulfill gender norms and responsibilities as caregivers but were also vigilant about protecting their own health. Men tended to be reluctant to accept CKD and appeared to depend on others for disease management. Better awareness and addressing these concerns can inform strategies to minimize gender disparities in access to care and outcomes in CKD.
RESUMO
AIMS: The aim of the study was to analyze the value of a completely new fuzzy logic-based detection algorithm (FA) in comparison with arrhythmia classification algorithms used in existing ICDs in order to demonstrate whether the rate of inappropriate therapies can be reduced. METHODS: On the basis of the RR intervals database containing arrhythmia events and controls recordings from the ICD memory a diagnostic algorithm was developed and tested by a computer program. This algorithm uses the same input signals as existing ICDs: RR interval as the primary input variable and two variables derived from it, onset and stability. However, it uses 15 fuzzy rules instead of fixed thresholds used in existing devices. The algorithm considers 6 diagnostic categories: (1) VF (ventricular fibrillation), (2) VT (ventricular tachycardia), (3) ST (sinus tachycardia), (4) DAI (artifacts and heart rhythm irregularities including extrasystoles and T-wave oversensing-TWOS), (5) ATF (atrial and supraventricular tachycardia or fibrillation), and 96) NT (sinus rhythm). This algorithm was tested on 172 RR recordings from different ICDs in the follow-up of 135 patients. RESULTS: All diagnostic categories of the algorithm were present in the analyzed recordings: VF (n = 35), VT (n = 48), ST (n = 14), DAI (n = 32), ATF (n = 18), NT (n = 25). Thirty-eight patients (31.4%) in the studied group received inappropriate ICD therapies. In all these cases the final diagnosis of the algorithm was correct (19 cases of artifacts, 11 of atrial fibrillation and 8 of ST) and fuzzy rules algorithm implementation would have withheld unnecessary therapies. Incidence of inappropriate therapies: 3 vs. 38 (the proposed algorithm vs. ICD diagnosis, respectively) differed significantly (p < 0.05). VT/VF were detected correctly in both groups. Sensitivity and specificity were calculated: 100%, 97.8%, and 100%, 72.9% respectively for FA and tested ICDs recordings (p < 0.05). CONCLUSIONS: Diagnostic performance of the proposed fuzzy logic based algorithm seems to be promising and its implementation could diminish ICDs inappropriate therapies. We found FA usefulness in correct diagnosis of sinus tachycardia, atrial fibrillation and artifacts in comparison with tested ICDs.
Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Diagnóstico por Computador/métodos , Lógica Fuzzy , Algoritmos , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: The use of subcutaneous implantable cardioverter-defibrillators (S-ICD) has been growing in Poland since 2014. The Polish Registry of S-ICD Implantations was run by the Heart Rhythm Section of the Polish Cardiac Society between May 2020 and September 2022 to monitor the implementation of that therapy in Poland. AIMS: To investigate and present the state-of-the-art of S-ICD implantation in Poland. METHODS: Implanting centers reported clinical data of patients undergoing S-ICD implantations and replacements, including age, sex, height, weight, underlying disease, history of pacemaker and defibrillator implantations, indications for S-ICD, electrocardiographical parameters, procedural techniques, and complications. RESULTS: Four hundred and forty patients undergoing S-ICD implantation (411) or replacement (29) were reported by 16 centers. Most patients were in New York Heart Association class II (218 patients, 53%) or I (150 patients, 36.5%). Left ventricular ejection fraction was 10%-80%, median (IQR) was 33% (25%-55%). Primary prevention indications were present in 273 patients (66.4%). Non-ischemic cardiomyopathy was reported in 194 patients (47.2%). The main reason for the choice of S-ICD were: young age (309, 75.2%), risk of infectious complications (46, 11.2%), prior infective endocarditis (36, 8.8%), hemodialysis (23, 5.6%), and immunosuppressive therapy (7, 1.7%). Electrocardiographic screening was performed in 90% of patients. The rate of adverse events was low (1.7%). No surgical complications were observed.
Assuntos
Desfibriladores Implantáveis , Humanos , Polônia , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Sistema de Registros , Morte Súbita Cardíaca/prevenção & controleRESUMO
BACKGROUND: A discrepancy between sex-specific treatment of kidney failure by dialysis (higher in men) and the prevalence of chronic kidney disease in the general population (higher in women) has been reported internationally, but the prevalence by sex has not been described for Austria. Sex disparity among nephrology outpatients has not been studied. METHODS: We employed two formulae (2009 CKD-EPI suppressing the race factor, and race-free 2021 CKD-EPI) to estimate the sex distribution of CKD in Austrian primary care, based on creatinine measurements recorded in a medical sample of 39,800 patients from general practitioners' offices (1989-2008). Further, we collected information from all clinic appointments scheduled at nephrology departments of 6 Austrian hospitals (Wien, Linz, Wels, St. Pölten, Villach, Innsbruck) during 2019 and calculated visit frequencies by sex. RESULTS: Using the 2009 CKD-EPI formula, the prevalence of CKD in stages G3-G5 (estimated glomerular filtration rate <â¯60â¯mL/min/1.73â¯m2) was 16.4% among women and 8.5% among men aged >â¯18 years who had attended general practitioners' offices in Austria between 1989 and 2008 and had at least one creatinine measurement performed. Using the 2021 CKD-EPI formula, the respective CKD prevalence was 12.3% among women and 6.1% among men. In 2019, 45% of all outpatients at 6 participating nephrology departments were women. The median of nephrology clinic visits in 2019 was two (per year) for both sexes. CONCLUSION: CKD is more prevalent among Austrian women than men. Men are more prevalent in nephrology outpatient services. Research into causes of this sex disparity is urgently needed.
Assuntos
Nefrologia , Insuficiência Renal Crônica , Masculino , Humanos , Feminino , Áustria/epidemiologia , Creatinina , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/terapia , Taxa de Filtração Glomerular , Instituições de Assistência AmbulatorialRESUMO
BACKGROUND: Along the root axis of Arabidopsis thaliana, cells pass through different developmental stages. In the apical meristem repeated cycles of division increase the numbers of cells. Upon leaving the meristem, these cells pass the transition zone where they are physiologically and mechanically prepared to undergo subsequent rapid elongation. During the process of elongation epidermal cells increase their length by 300% in a couple of hours. When elongation ceases, the cells acquire their final size, shape and functions (in the differentiation zone). Ethylene administered as its precursor 1-aminocyclopropane-1-carboxylic acid (ACC) is capable of inhibiting elongation in a concentration-dependent way. Using a microarray analysis, genes and/or processes involved in this elongation arrest are identified. RESULTS: Using a CATMA-microarray analysis performed on control and 3h ACC-treated roots, 240 differentially expressed genes were identified. Quantitative Real-Time RT-PCR analysis of the 10 most up and down regulated genes combined with literature search confirmed the accurateness of the analysis. This revealed that inhibition of cell elongation is, at least partly, caused by restricting the events that under normal growth conditions initiate elongation and by increasing the processes that normally stop cellular elongation at the end of the elongation/onset of differentiation zone. CONCLUSIONS: ACC interferes with cell elongation in the Arabidopsis thaliana roots by inhibiting cells from entering the elongation process and by immediately stimulating the formation of cross-links in cell wall components, diminishing the remaining elongation capacity. From the analysis of the differentially expressed genes, it becomes clear that many genes identified in this response, are also involved in several other kind of stress responses. This suggests that many responses originate from individual elicitors, but that somewhere in the downstream signaling cascade, these are converged to a 'common pathway'. Furthermore, several potential keyplayers, such as transcription factors and auxin-responsive genes, were identified by the microarray analysis. They await further analysis to reveal their exact role in the control of cell elongation.
Assuntos
Aminoácidos Cíclicos/farmacologia , Arabidopsis/crescimento & desenvolvimento , Arabidopsis/genética , Genes de Plantas/genética , Raízes de Plantas/citologia , Raízes de Plantas/crescimento & desenvolvimento , Arabidopsis/efeitos dos fármacos , Regulação para Baixo/efeitos dos fármacos , Regulação para Baixo/genética , Perfilação da Expressão Gênica , Regulação da Expressão Gênica de Plantas/efeitos dos fármacos , Raízes de Plantas/efeitos dos fármacos , Raízes de Plantas/genética , Regulação para Cima/efeitos dos fármacos , Regulação para Cima/genéticaRESUMO
Introduction: Globally, there are more women with chronic kidney disease (CKD), yet they comprise only 40% of patients receiving kidney replacement therapy by dialysis. We aimed to describe the perspectives of nephrologists on gender disparities in access to care and outcomes in CKD and dialysis. Methods: We conducted semistructured interviews with 51 nephrologists (28, 55% women) from 22 countries from October 2019 to April 2020. Transcripts were analyzed thematically. Results: We identified 6 themes. Related to women were primary commitment to caregiving (with subthemes of coordinating care, taking charge of health management, deprioritizing own health, centrality of family in decision-making); vigilance and self-reliance (diligence and conscientiousness, stoicism and tolerating symptoms, avoiding burden on family, isolation and coping alone); and stereotyping, stigma, and judgment (body image, dismissed as anxiety, shame and embarrassment, weakness and frailty). Related to men was protecting masculinity (safeguarding the provider role, clinging to control, self-regard, and entitled). Decisional power and ownership included men's dominance in decision-making and women's analytical approach in treatment decisions. Inequities compounded by social disadvantage (financial and transport barriers, without social security, limited literacy, entrenched discrimination, vulnerability) were barriers to care for women, particularly in socioeconomically disadvantaged communities. Conclusion: Nephrologists perceived that women with CKD faced many challenges in accessing care related to social norms and roles of caregiving responsibilities, disempowerment, lack of support, stereotyping by clinicians, and entrenched social and economic disadvantage. Addressing power differences, challenging systemic patriarchy, and managing unconscious bias may help to improve equitable care and outcomes for all people with CKD.
RESUMO
Sudden cardiac death (SCD) constitutes a major clinical and public health problem, whose death burden is comparable to the current worldwide pandemic. This comprehensive review encompasses the following topics: available rescue systems, wearable electrocardiograms (ECG), detection and transmission technology, and a newly developed fuzzy logic algorithm (FA) for heart rhythm classification which is state-of-the art in the field of SCD prevention. Project "PROTECTOR", the Polish Rapid Transtelephonic ECG to Obtain Resuscitation for development of a rapid rescue system for patients at risk of sudden cardiac arrest (SCA), is presented. If a lethal arrhythmia is detected on the basis of FA, the system produces an alarm signal audible for bystanders and transmits the alarm message along with location to the emergency medical center. Phone guided resuscitation can be started immediately because an automated external defibrillator (AED) localization map is available. An automatic, very fast diagnosis is a unique feature of the PROTECTOR prototype. The rapid detection of SCA is based on a processor characterized by 100% sensitivity and 97.8% specificity (as measured in the pilot studies). An integrated circuit which implements FA has already been designed and a diagnosis is made within few seconds, which is extremely important in ischemic brain damage prophylaxis. This circuit could be implemented in smart implants (Sis).
RESUMO
BACKGROUND: Prediction of sudden cardiac death remains a significant challenge. There is some evidence that ventricular ectopic activity could be regarded as a predictive marker. OBJECTIVES: We carried out an analysis to explore whether premature ventricular complexes (PVCs) are a risk factor in implantable cardioverter-defibrillator (ICD) interventions. MATERIAL AND METHODS: The study method was a RR interval series analysis (n = 184) of arrhythmic events and controls from the ICD. Study group consisted of patients with a mean age of 55 ±27 years; 74% of them were male, 85% were secondary prevention patients, 62% had coronary artery disease (CAD), 15% hypertropic cardiomyopathy (HCM), 15% dilated cardiomyopathy (DCM), and 8% diseases of other etiology. The mean follow-up time was 64 months (range: 3-126 months). The study population was divide into patients with at least 1 appropriate intervention ventricular tachycardia/ventricular fibrillation (VT/VF) (group A, n = 101) and controls without interventions (group B, n = 83). The number of PVC/4000 RR cycles, the shortest coupling intervals between a PVC and preceding R as well as the number of PVCs of very short (180-220 ms), short (220-280 ms) and different cycle lengths (CL) as well as the incidence of short-long-short (SLS) sequences were compared. RESULTS: The number of PVCs/4000 RR cycles was significantly higher in group A (263 ±32 compared to 43 ±17, p < 0.0001). The mean shortest PVC CL was significantly shorter in group A (320 ±13 compared to 400 ±38, p = 0.029). The number of PVCs with a very short CL was 1 ±0.4 compared to 0.1 ±0.1 (p = 0.028). The number of PVCs with a short CL was 5 ±1.2 compared to 0.6 ±0.4 (p = 0.0007) in groups A and B, respectively. The incidence of SLS sequences was significantly higher in group A than in group B (67 (94% of patients) and 4 (33% of patients) respectively (p < 0.0001)). CONCLUSIONS: Significant differences were found in the characteristics of PVCs and SLS sequences between patients with appropriate ICD interventions and controls. A newly developed basic computer program called PCRR was applied for RR interval analysis. This simple method could be a predictor of PVC burden and life-threatening arrhythmias in different populations.
Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Adulto , Idoso , Idoso de 80 Anos ou mais , Morte Súbita Cardíaca/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/terapia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/terapiaRESUMO
The implantation of a subcutaneous cardioverter-defibrillator (S-ICD) may be used instead of a traditional transvenous system to prevent sudden cardiac death. Our aim was to compare the characteristics of S-ICD patients from the multi-center registry of S-ICD implantations in Poland with the published results of the European Snapshot Survey on S-ICD Implantation (ESSS-SICDI). We compared data of 137 Polish S-ICD patients with 68 patients from the ESSS-SICDI registry. The groups did not differ significantly in terms of sex, prevalence of ischemic cardiomyopathy, concomitant diseases, and the rate of primary prevention indication. Polish patients had more advanced heart failure (New York Heart Association (NYHA) class III: 11.7% vs. 2.9%, NYHA II: 48.9% vs. 29.4%, NYHA I: 39.4% vs. 67.7%, p < 0.05 each). Young age (75.9% vs. 50%, p < 0.05) and no vascular access (7.3% vs. 0%, p < 0.05) were more often indications for S-ICD. The percentage of patients after transvenous system removal due to infections was significantly higher in the Polish group (11% vs. 1.5%, p < 0.05). In the European population, S-ICD was more frequently chosen because of patients' active lifestyle and patients' preference (both 10.3% vs. 0%, p < 0.05). Our analysis shows that in Poland, compared to other European countries, subcutaneous cardioverters-defibrillators are being implanted in patients at a more advanced stage of chronic heart failure. The most frequent reason for choosing a subcutaneous system instead of a transvenous ICD is the young age of a patient.
Assuntos
Desfibriladores Implantáveis , Europa (Continente) , Humanos , New York , Polônia/epidemiologia , Sistema de Registros , Resultado do TratamentoRESUMO
BACKGROUND: Systematic analyses about sex differences in wait-listing and kidney transplantation after dialysis initiation are scarce. We aimed at identifying sex-specific disparities along the path of kidney disease treatment, comparing two countries with distinctive health care systems, the US and Austria, over time. METHODS: We analyzed subjects who initiated dialysis from 1979-2018, in observational cohort studies from the US and Austria. We used Cox regression to model male-to-female cause-specific hazard ratios (csHRs, 95% confidence intervals) for transitions along the consecutive states dialysis initiation, wait-listing, kidney transplantation and death, adjusted for age and stratified by country and decade of dialysis initiation. RESULTS: Among 3,053,206 US and 36,608 Austrian patients starting dialysis, men had higher chances to enter the wait-list, which however decreased over time [male-to-female csHRs for wait-listing, 1978-1987: US 1.94 (1.71, 2.20), AUT 1.61 (1.20, 2.17); 2008-2018: US 1.35 (1.32, 1.38), AUT 1.11 (0.94, 1.32)]. Once wait-listed, the advantage of the men became smaller, but persisted in the US [male-to-female csHR for transplantation after wait-listing, 2008-2018: 1.08 (1.05, 1.11)]. The greatest disparity between men and women occurred in older age groups in both countries [male-to-female csHR for wait-listing after dialysis, adjusted to 75% age quantile, 2008-2018: US 1.83 (1.74, 1.92), AUT 1.48 (1.02, 2.13)]. Male-to-female csHRs for death were close to one, but higher after transplantation than after dialysis. CONCLUSIONS: We found evidence for sex disparities in both countries. Historically, men in the US and Austria had 90%, respectively, 60% higher chances of being wait-listed for kidney transplantation, although these gaps decreased over time. Efforts should be continued to render kidney transplantation equally accessible for both sexes, especially for older women.
RESUMO
Titin truncating variants (TTNtv) are known as the leading cause of inherited dilated cardiomyopathy (DCM). Nevertheless, it is unclear whether circulating cardiac biomarkers are helpful in detection and risk assessment. We sought to assess 1) early indicators of cardiotitinopathy including the serum biomarkers high-sensitivity cardiac troponin T (hs-cTnT) and N-terminal pro-B-type natriuretic peptide (NT-proBNP) in clinically stable patients, and 2) predictors of outcome among TTNtv carriers. Our single-center cohort consisted of 108 TTNtv carriers (including 70 DCM patients) from 43 families. Clinical, laboratory and follow-up data were analyzed. The earliest abnormality was left ventricular dysfunction, present in 8, 26 and 47% of patients in the second, third and fourth decade of life, respectively. It was followed by symptoms of heart failure, linked to NT-proBNP elevation and severe left ventricular systolic dysfunction, and later by arrhythmias. Hs-cTnT serum levels were increased in the late stage of the disease only. During the median follow-up of 5.2 years, both malignant ventricular arrhythmia (MVA) and end-stage heart failure (esHF) occurred in 12% of TTNtv carriers. In multivariable analysis, NT-proBNP level ≥650 pg/mL was the best predictor of both composite endpoints (MVA and esHF) and of MVA alone. In conclusion, echocardiographic abnormalities are the first detectable anomalies in the course of cardiotitinopathies. The assessment of circulating cardiac biomarkers is not useful in the detection of the disease onset but may be helpful in risk assessment.
RESUMO
INTRODUCTION: Although implantable cardioverter-defibrillators (ICDs) are used in sudden cardiac death (SCD) prevention in high-risk patients with hypertrophic cardiomyopathy (HCM), long-term results as well as precise risk stratification are discussed in a limited number of reports. The aim of the study was to assess the incidence of ICD intervention in HCM patients with relation to clinical risk profile. METHODS AND RESULTS: We studied 104 consecutive patients with HCM implanted in a single center. The mean age of study population was 35.6 (SD, 16.2) years with the average follow-up of 4.6 (SD, 2.6) years. ICD was implanted for secondary (n = 26) and primary (n = 78) prevention of SCD. In the secondary prevention group, 14 patients (53.8%) experienced at least 1 appropriate device intervention (7.9%/year). In the primary prevention (PP) group appropriate ICD discharges occurred in 13 patients (16.7%) and intervention rate was 4.0%/year. Nonsustained VT was the only predictive risk factor (RF) for an appropriate ICD intervention in the PP (positive predictive value 22%, negative predictive value 96%). No significant difference was observed in the incidence of appropriate ICD discharges between PP patients with 1, 2, or more RF. Complications of the treatment included: inappropriate shocks (33.7%), lead dysfunction (12.5%), and infections: 4.8% of patients. Four patients died during follow-up. CONCLUSION: ICD therapy is effective in SCD prevention in patients with HCM, although the complication rate is significant. Nonsustained ventricular tachycardia seems to be the most predictive RF for appropriate device discharges. Number of RF did not impact the incidence of appropriate ICD interventions.
Assuntos
Cardiomiopatia Hipertrófica/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Taquicardia Ventricular/terapia , Adulto , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/mortalidade , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Intervalo Livre de Doença , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Eletrocardiografia Ambulatorial , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Polônia , Modelos de Riscos Proporcionais , Falha de Prótese , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Resultado do Tratamento , Adulto JovemRESUMO
AIMS: Young implantable cardioverter-defibrillator (ICD) recipients present a high rate of inappropriate interventions. Some of them are caused by suboptimal pre-discharge programming of the device. There are conflicting data as regards antitachycardia pacing (ATP) effectiveness in children and young adults. We report our experience with ICD programming and a rate of complications during a 10 year follow-up. METHODS AND RESULTS: We analysed the use and effectiveness of ATP and complications rate in 63 patients aged 6-21 years. Antitachycardia pacing (burst or ramp) was programmed ON in 14 patients (22%), 49 patients (78%) had only ventricular fibrillation (VF) therapy when discharged after implantation. The incidence of effective vs. ineffective or harmful ATP therapy: 5% of patients vs. 19% of patients differed significantly (P < 0.05). Fourteen patients (22%) received > or =1 appropriate shock(s) for ventricular tachycardia/VF and 17 patients (27%) had one or multiple inappropriate therapy (IT). Inappropriate therapy resulted from T-wave over-sensing (nine patients), sinus tachycardia (three patients), fast atrial fibrillation (five patients), and lead insulation disruption (1%). Reprogramming of the device eliminated IT in all cases. There were 13 (21%) surgical complications. Serious psychological sequelae developed in 27 (43%) patients. There was one death during the follow-up period. CONCLUSION: Antitachycardia pacing therapy is rarely effective and often harmful in young ICD recipients. In most patients, programming ICD for only VF therapy is sufficient. Routine pre-discharge programming against inappropriate interventions (especially T-wave over-sensing) helps to reduce the incidence of discharges during the follow-up. The incidence of complications and inappropriate therapies is high in young ICD recipients and affects 50% of patients.
Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Ventricular/terapia , Adolescente , Adulto , Criança , Feminino , Seguimentos , Humanos , Masculino , Software , Volume Sistólico , Taquicardia/terapia , Falha de Tratamento , Adulto JovemRESUMO
BACKGROUND: Implantation of a left ventricular (LV) lead for cardiac resynchronisation therapy (CRT) may be challenging. Wider use of various implantation techniques increases the success rate of CRT. AIM: Short-term analysis of the success rate of transvenous LV lead implantation for CRT. METHODS: All CRT procedures performed in 2009 with first-time LV lead implantation attempt were analysed in terms of efficacy, total number of procedures, procedure and fluoroscopy time, complications, and reinterventions. Final LV lead location and the number of tested sites were analysed. Complex procedures were defined and described. RESULTS: We studied 122 patients aged 67.6 +/- 10.6 years (98 males/80%) selected for CRT. The CRT implantation was an upgrade procedure in 17 patients. Fifty-six (46%) patients had coronary artery disease and 111 (91%) patients were in NYHA class III. The mean LV ejection fraction was 27% (range 10-35%). The implantation success rate was 97.5%. There were 87 (73%) CRT-D systems implanted and 32 (27%) CRT-P systems. Mean procedure time was 118 +/- 41 min, and fluoroscopy time was 15.9 +/- 12.1 min. An optimal location of the LV lead was achieved in 107 (90%) patients. More than one LV lead sites were tested in 42 (35.3%) patients. Complex procedures were performed in 4 (3.4%) patients. Early LV lead reintervention (< 30 days) was necessary in 10 (8.4%) patients (11 procedures), and epicardial lead placement was performed in one patient. The LV lead location in the antero-lateral branch demonstrated the lowest reintervention rate (1/22, 4.5%) v. other sites (great cardiac vein: 1/8, 12.5%, lateral branches: 9/86, 10.5%, p = NS). The LV lead-related reinterventions and initial procedure failure were associated with the upgrade procedures. No serious periprocedural complications were recorded. In one patient, the CRT system was explanted due to pocket infection. One patent died three months after CRT implantation due to progressive end-stage congestive heart failure. CONCLUSIONS: 1. In a tertiary centre, CRT implantation success rate is high and implantation procedures are safe. 2. Achieved LV lead location is optimal in a vast majority of patients. 3. We noted a significant rate of early reinterventions related to LV lead dislodgement. 4. The LV lead implantation failure and reinterventions occurred more frequently in subjects with upgrade- to-CRT procedures. A similar trend was also noted in patients after cardiac surgery. 5. In selected cases, advanced techniques must be used to achieve successful CRT implantation.
Assuntos
Estimulação Cardíaca Artificial/métodos , Doença da Artéria Coronariana/terapia , Vasos Coronários/cirurgia , Eletrodos Implantados , Ventrículos do Coração/cirurgia , Marca-Passo Artificial , Idoso , Arritmias Cardíacas/terapia , Feminino , Seguimentos , Insuficiência Cardíaca/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Polônia , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Transvenous implantable cardioverter-defibrillators (ICD) have been implanted in Poland since 1995. As the method spreads it is important to consider its long-term benefits and disadvantages. AIM: To assess survival, efficacy and complication rate in ICD patients, who received the device more than ten years earlier. METHODS: Retrospective analysis of 60 ICD patients implanted between 1995-1999. RESULTS: There were 42 (70%) males, mean age 50.6 ± 16.4 years. In 59 patients ICD was implanted for sudden cardiac death (SCD) secondary prevention. Thirty eight patients (34 M, 63.3%) had coronary artery disease (CAD). The CAD was diagnosed in 89.5% of males and 10.5% of females (pã 0.0001). Mean follow-up time was 75.4 ± 34.7 months. During this time 22 patients died (37%, 19 M, 3 F). Three deaths were SCD. Mean one-year mortality was 6.7%. Deaths were more frequent among males: 45.2% vs 16.7%, pã 0.005. In CAD mortality was higher than in non-CAD patients (50% vs 13.6%, pã 0.005). Appropriate ICD discharges in the ventricular fibrillation (VF) zone occurred in 35 (58%) patients, and in ventricular tachycardia (VT) zone - in 26 (43%) patients. Mean intervention rate per year was 3.7 for VF and 0.6 for VT. Complications occurred in 27 (45%) patients and 5 (8%) of them had no ICD intervention during follow-up. In 5 patients more than one complication was diagnosed. There were inappropriate discharges in 15 (25%) patients, 11 (18%) had electrical storm, and ICD-related infections were noted in 3 (5%) patients. During the perioperative period, lead revisions were done in 4 patients; in 3 with discharges induced by T-wave oversensing and in one with lead dislocation. Four cases of lead failure occurred during follow-up, requiring new lead implantation. In 4 patients, electrical storm (3 patients) and supraventricular tachycardia with ICD discharges (1 patient) were treated with radiofrequency ablation. Only 10 (17%) patients did not demonstrate any ICD interventions or ICD-related complications. CONCLUSIONS: 1. ICD interventions caused by malignant ventricular arrhythmias occurred in 75% patients with the device implanted more than 10 years earlier. 2. Almost a half of the analysed population suffered from complications and side effects related to implanted ICD and they were present in 8% of subjects without ICD intervention. Neither ICD interventions nor device-related adverse events were recorded in 17% of patients.