1.
Ecotoxicol Environ Saf ; 255: 114800, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36933481

RESUMO

Epidemiological studies have demonstrated that particulate matter (PM) can induce or exacerbate hypertension. High relative humidity has been associated with elevated blood pressure in certain regions. However, the coupling effect of humidity and PM on elevated blood pressure and the underlying mechanisms remain unknown. Herein, we aimed to explore the effects of exposure to PM and/or high relative humidity on hypertension, as well as elucidate underlying mechanisms. Male C57/BL6 mice were intraperitoneally administered NG-nitro-L-arginine methyl ester (L-NAME) to establish a hypertensive mouse model. The hypertensive mice were exposed to PM (0.15 mg/kg/day) and/or different relative humidities (45/90%) for eight weeks. Histopathological changes, systolic blood pressure (SBP), endothelial-derived contracting factors (thromboxane B2 [TXB2], Prostaglandin F2α [PGF2α], endothelin-1 [ET-1], and angiotensin II [Ang II]), and relaxing factors (prostaglandin I2 [PGI2] and nitric oxide [NO]) were measured to assess the effects of PM exposure and humidity on hypertension in mice. Levels of transient receptor potential vanilloid 4 (TRPV4), cytosolic phospholipase A2 (cPLA2), and cyclooxygenase 2 (COX2) were measured to explore their potential mechanisms. Herein, exposure to 90% relative humidity or PM alone had a slight but insignificant effect on hypertension. However, pathological changes and elevated blood pressure were markedly exacerbated following exposure to PM and 90% relative humidity. Levels of PGF2α, TXB2, and ET-1 were significantly increased, whereas the PGI2 level was substantially decreased. HC-067047-mediated blockade of TRPV4 suppressed TRPV4, cPLA2, and COX2 expression and effectively alleviated the increased blood pressure induced by exposure to PM and 90% relative humidity. These results indicate that 90% relative humidity and PM can activate the TRPV4-cPLA2-COX2 ion channel in the aorta, altering the endothelial-derived contracting and relaxing factors and enhancing blood pressure in hypertensive mice.


Assuntos
Antineoplásicos , Hipertensão , Animais , Masculino , Camundongos , Antineoplásicos/farmacologia , Pressão Sanguínea , Ciclo-Oxigenase 2/genética , Ciclo-Oxigenase 2/metabolismo , Umidade , Hipertensão/induzido quimicamente , Óxido Nítrico/metabolismo , Canais de Cátion TRPV/metabolismo , Canais de Cátion TRPV/farmacologia , Canais de Cátion TRPV/uso terapêutico , Fosfolipases A2 Citosólicas/metabolismo
2.
Indoor Air ; 32(9): e13113, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36168229

RESUMO

The presence of dampness and visible molds leads to concerns of poor indoor air quality which has been consistently linked with increased exacerbation and development of allergy and respiratory diseases. Due to the limitations of epidemiological surveys, the actual fungal exposure characteristics in residences has not been sufficiently understood. This study aimed to characterize household fungal diversity and its annual temporal and spatial variations. We developed combined cross-sectional survey, repeated air sampling around a year, and DNA sequencing methods. The questionnaire survey was conducted in 2019, and 4943 valid cases were received from parents; a follow-up case-control study (11 cases and 12 controls) was designed, and onsite measurements of indoor environments were repeated in typical summer, transient season, and winter; dust from floor and beddings in children's room were collected and ITS based DNA sequencing of totally 68 samples was conducted. Results from 3361 children without changes to their residences since birth verified the significant associations of indoor dampness/mold indicators and prevalence of children-reported diseases, with increased adjusted odd ratios (aORs) >1 for studied asthma, wheeze, allergic rhinitis, and eczema. The airborne fungal concentrations from air sampling were higher than 1000 CFU/m3 in summer, regardless of indoors and outdoors, indicating an intermediate pollution level. The DNA sequencing for dust showed the Aspergillus was the predominant at genus level and the Aspergillus_penicillioides was the most common at species level; while the fungal community and composition varied significantly in different homes and seasons, according to α and ß diversity analyses. The comprehensive research methods contribute to a holistic understanding of indoor fungal exposure, including the concentrations, seasonal variations, community, and diversity, and verifies the relations with children's adverse health outcomes. The study further elucidates the role of microbiome in human health, which helps setting health-protective thresholds and managing mold treatments in buildings, to promote indoor air quality and human well-beings.


Assuntos
Poluição do Ar em Ambientes Fechados , Rinite Alérgica , Poluição do Ar em Ambientes Fechados/análise , Estudos de Casos e Controles , Criança , Estudos Transversais , Poeira , Fungos , Visita Domiciliar , Humanos , Rinite Alérgica/epidemiologia , Inquéritos e Questionários
3.
Indoor Air ; 32(6): e13063, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35762240

RESUMO

Common cold is usually considered to be associated with outdoor climate, but the evidence linking with indoor environmental factors is lacking. The role of indoor renovations during which critical timing window on childhood common cold remains unclear. Therefore, we investigated the effect of exposure to new furniture and/or redecoration during prenatal and postnatal periods on the occurrence and duration of common cold in preschool children. We conducted a retrospective cohort study of 39 782 children aged 3-6 years in seven cities of China. The occurrence and duration of common cold in children, and their lifetime exposures to indoor new furniture and redecoration (including pregnancy, the first year of life, and after one year old) were assessed using a questionnaire administered by the parents. Associations between high frequency (>5 colds) and long duration (≥2 weeks per cold) of common cold during past 12 months and exposure to indoor new furniture/redecoration were examined by logistic regression models in terms of odds ratio (OR) and 95% confidence interval (CI). We found that the prevalence of high frequency and long duration of common cold in preschool children in China were, respectively, 9.2% and 11.9%. Frequent common cold was significantly associated with exposure to indoor new furniture/redecoration during pregnancy, first year, and after 1 year old, respectively, with the ORs (95% CI) = 1.25 (1.12-1.39), 1.11 (1.00-1.25), and 1.09 (1.01-1.18). Furthermore, childhood long duration per cold was associated with exposure to indoor new furniture/redecoration during pregnancy with OR (95% CI) of 1.14 (1.03-1.25) but not with postnatal exposure. We identified that prenatal exposure to home renovation was more critical than postnatal exposure for an increased risk of high frequency and long duration of common cold. Sensitivity analysis showed that the association between prenatal exposure to indoor renovations and the risk of childhood common cold was consistent and robust, and the associations were modified by some personal and indoor environmental factors. Our findings indicated that prenatal and postnatal exposure to home renovation played an important role in the risk of childhood common cold, supporting the hypothesis of "fetal origin of childhood infection."


Assuntos
Poluição do Ar em Ambientes Fechados , Resfriado Comum , Efeitos Tardios da Exposição Pré-Natal , Poluição do Ar em Ambientes Fechados/análise , Pré-Escolar , China/epidemiologia , Resfriado Comum/epidemiologia , Exposição Ambiental , Feminino , Humanos , Lactente , Gravidez , Estudos Retrospectivos , Fatores de Risco
4.
Indoor Air ; 32(1): e12918, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34337784

RESUMO

A questionnaire survey on dermal symptoms and home environment was performed in eight Chinese cities (40 279 participants). Data on city level temperature, precipitation, PM10 , NO2, and gross domestic product (GDP) per capita were collected. In total, 2.2% had eczema, 2.4% facial erythema (FE) and 2.6% seborrheic dermatitis symptoms (SD). Higher temperature was associated with eczema (OR = 1.09). Higher GDP per capita was related to less SD. Higher PM10 was related to SD. Suburban living was protective for eczema (OR = 0.77) (vs. urban). Living in old buildings (built before 1991) was related to eczema (OR = 1.42). Living near heavily trafficked roads was related to FE (OR = 1.33) and SD (OR = 1.35). Having new furniture was related to all symptoms (OR = 1.26-1.47). Burning mosquito coils (OR = 1.37-1.57) and incense (OR = 1.33-1.37) were associated with eczema, FE, or SD. Presence of cockroaches and rats/mice was associated with FE or SD (OR = 1.31-1.40). Using air conditioner, daily cleaning and frequently exposing bedding to sunshine were protective (OR = 0.60-0.83). In conclusion, higher temperature, higher PM10 , urban living, living near heavily trafficked roads, old buildings, new furniture, burning mosquito coils and incense, and presence of cockroaches/rats/mice increased the risk of eczema, FE, or SD. Higher GDP, air conditioner, daily cleaning, and exposing bedding to sunshine were protective.


Assuntos
Poluição do Ar , Dermatite Seborreica , Eczema , Eritema , Poluentes Atmosféricos/análise , Poluentes Atmosféricos/toxicidade , Poluição do Ar/análise , Poluição do Ar/estatística & dados numéricos , Poluição do Ar em Ambientes Fechados/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Animais , China/epidemiologia , Dermatite Seborreica/epidemiologia , Eczema/epidemiologia , Eritema/epidemiologia , Eritema/etiologia , Ambiente Domiciliar , Humanos , Camundongos , Material Particulado/análise , Material Particulado/toxicidade , Ratos , Fatores de Risco , Adulto Jovem
5.
Ecotoxicol Environ Saf ; 241: 113786, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35738102

RESUMO

In respiratory diseases, the induction of allergic asthma is one of the hottest issues of international concern. The adjuvant effect of air pollutants including nanoparticles (NPs) has be pointed out to facilitate the occurrence and development of allergic asthma. This work studied the development of allergic asthma upon exposures of carbon black nanoparticles (CB NPs, 30-50 nm) and/or high environmental humidity (90% relative humidity). The mechanisms involved were investigated from perspectives of the activation of oxidative stress and transient receptor potential vanilloid 1 (TRPV1) pathways and the alteration in intestinal microbiota. Both high humidity and CB NPs aggravated the airway hyperreactivity, remodeling, and inflammation in Balb/c mice sensitized by ovalbumin. The co-exposure of these two risk factors exhibited adjuvant effect on the development of asthma likely through activating oxidative stress pathway and TRPV1 pathway and then facilitating type I hypersensitivity. Additionally, exposures of high humidity and/or CB NPs reduced the richness of intestinal microbes, altered microbial community composition, and weakened corresponding biological functions, which may interact with the development of asthma. The findings will add new toxicological knowledge to the health risk assessment and management of co-exposures of NPs and other risk factors in the environment.


Assuntos
Asma , Microbioma Gastrointestinal , Nanopartículas , Animais , Asma/induzido quimicamente , Asma/metabolismo , Modelos Animais de Doenças , Umidade , Pulmão , Camundongos , Camundongos Endogâmicos BALB C , Nanopartículas/toxicidade , Ovalbumina , Fuligem/toxicidade
6.
Indoor Air ; 31(2): 541-556, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32731305

RESUMO

Despite concerns about building dampness and children' health, few studies have examined the effects of building energy efficiency standards. This study explored the connections between self-reported household dampness and children' adverse health outcomes across buildings corresponding to construction periods (pre-2001, 2001-2010, post-2010). Significant differences of dampness-related indicators were found between buildings; the prevalence was remarkable in pre-2001 buildings. The prevalence of lifetime-ever doctor-diagnosed diseases for children was significantly associated with building dampness (adjust odd ratios > 1), but was not affected by construction periods. The hygrothermal performance for a typical residence was simulated, varying in U-values of envelopes and air change rates. The simulated performance improvement increased indoor temperatures in 2001-2010 and post-2010 buildings. The frequency with higher indoor relative humidity was higher in pre-2001 buildings, leading to the highest values for maximum mold index (Mmax ) on wall surface, especially in winter. Compared to buildings in 2001-2010, increased insulation and lower air change rate led to a relatively higher relative humidity in post-2010 buildings, adversely increasing the Mmax values. The findings addressed the positive and negative role of building standard development, which help suggesting appropriate environmental and design solutions to trade-off energy savings and dampness/mold risk in residences.


Assuntos
Poluição do Ar em Ambientes Fechados , Saúde da Criança/estatística & dados numéricos , Umidade , Criança , Conservação de Recursos Energéticos , Fungos , Habitação , Humanos , Modelos Logísticos , Prevalência , Temperatura
7.
Indoor Air ; 30(5): 827-840, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32297363

RESUMO

During 2010-2012, we surveyed 40,010 3- to 6-year-old children in seven Chinese cities (Beijing, Taiyuan, Urumqi, Shanghai, Nanjing, Changsha, and Chongqing). Their parents reported information on household renovation, including the timing of renovation and the choice of materials for walls and floors in the child's room, and the incidence of their child's rhinitis. Multivariate and two-level (city-child) logistic regression analyses yielding adjusted odds ratios (AOR) with 95% confidence intervals were performed. Sensitivity analyses stratifying data for location and economic level were also performed. About 48.0% of the children had ever had allergic rhinitis, 41.2% had current allergic rhinitis, and 9.0% had had doctor-diagnosed rhinitis. Exposure to household renovation during early lifetime (birth to 1-year-old) had an AOR of 1.43 (1.04-1.9) for allergic rhinitis. The incidence of allergic rhinitis was significantly different in children exposed to different floor and wall covering materials. Floor or wall covering material composed of organic materials significantly increased the risk of childhood allergic rhinitis compared with tile flooring or lime wall covering. Oil paint had an AOR of 1.66 (1.28-2.14) for diagnosed rhinitis compared with lime wall covering. Adding new furniture the year before pregnancy was associated with an AOR of 1.18 (1.10-1.27) and 1.18 (1.11-1.25) for lifetime and current rhinitis. Solid wood or tiles/ceramic as floor materials, and using wallpaper, oil paint, or emulsion panels as wall materials were risk factors for doctor-diagnosed rhinitis. Sensitivity analyses showed that children living in southern or higher economic level China cities were more likely to have allergic rhinitis with household renovation.


Assuntos
Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Habitação/estatística & dados numéricos , Rinite Alérgica/epidemiologia , Criança , Pré-Escolar , China/epidemiologia , Exposição Ambiental/estatística & dados numéricos , Características da Família , Feminino , Pisos e Cobertura de Pisos , Humanos , Masculino , Prevalência , Inquéritos e Questionários
8.
Respirology ; 24(3): 238-245, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30440113

RESUMO

BACKGROUND AND OBJECTIVE: Studies from epidemiology suggest that ambient temperature is one of the underlying triggers and potential causes of asthma. The aim of this study was to examine the impact and the molecular mechanism of temperature-invoked airway inflammation using an experimental model of asthma in BALB/c mice. METHODS: Mice were exposed to different temperature conditions (steady 26°C, 26°C/18°C cycle, 26°C/10°C cycle) and received sensitization and challenge of ovalbumin (OVA) during a 21-day period. HC030031, a selective transient receptor potential A1 (TRPA1) channel blocker, was used to investigate the underlying mechanism of TRPA1 in 'asthmatic' airways. After the final OVA challenge, in vivo lung function was measured, and bronchoalveolar lavage fluid (BALF) and pulmonary inflammation were assessed. RESULTS: The temperature variations, especially the largest temperature difference (16°C), exacerbated airway inflammation in OVA-induced mice, increasing the levels of serum total-IgE (immunoglobulin E) and IgG1, inflammatory cells and cytokines in BALF. Analysis of histopathological changes and lung function verified that repeated exposure to very cold and changed temperatures aggravated airway hyperresponsiveness (AHR). Significant upregulation of TRPA1 expression was revealed by immunohistochemistry in the presence of the largest temperature variation (26°C/10°C cycle), while administration of HC030031 successfully inhibited TRPA1 expression, thus attenuating the asthma-like pathological features. CONCLUSION: Repeated exposure to temperature variation exacerbated experimental 'asthma' and TRPA1 mediated this temperature-dependent inflammatory effect.


Assuntos
Asma/patologia , Asma/fisiopatologia , Canal de Cátion TRPA1/metabolismo , Temperatura , Acetanilidas/farmacologia , Animais , Asma/etiologia , Líquido da Lavagem Broncoalveolar/química , Líquido da Lavagem Broncoalveolar/citologia , Citocinas/metabolismo , Modelos Animais de Doenças , Imunoglobulina E/sangue , Imunoglobulina G/sangue , Inflamação/etiologia , Inflamação/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Ovalbumina , Purinas/farmacologia , Canal de Cátion TRPA1/antagonistas & inibidores
9.
Indoor Air ; 29(5): 748-760, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31295372

RESUMO

We surveyed 40 010 three- to six-year-old children in seven Chinese cities (Beijing, Taiyuan, Urumqi, Shanghai, Nanjing, Changsha, and Chongqing) during 2010-2012 so as to investigate possible links between home renovation and childhood eczema. Their parents responded to questions on home renovation and childhood eczema. Multivariate and two-level (city-child) logistic regression analyses yielding odds ratios with 95% confidence intervals were performed. Sensitivity analyses stratifying data for region, climate, and income level were also performed. The prevalences of childhood eczema in children with different floor and wall covering materials were significantly different and were significantly higher with home renovation during early lifetime. Exposure to synthetic materials significantly increased the risk of childhood eczema by 20%-25%. The risks (AOR, 95% CI) of current eczema among children in families with solid wood flooring and oil paint wall covering were 1.25 (1.04-1.49) and 1.35 (1.14-1.60), respectively. Home renovation during pregnancy was related to children's lifetime and current eczema.


Assuntos
Poluição do Ar em Ambientes Fechados/efeitos adversos , Materiais de Construção/efeitos adversos , Eczema/epidemiologia , Eczema/etiologia , Adulto , Criança , Pré-Escolar , China/epidemiologia , Cidades , Estudos Transversais , Exposição Ambiental , Feminino , Pisos e Cobertura de Pisos , Habitação , Humanos , Modelos Logísticos , Masculino , Pintura/efeitos adversos , Gravidez , Efeitos Tardios da Exposição Pré-Natal/etiologia , Prevalência , Fatores de Risco , Inquéritos e Questionários
10.
Indoor Air ; 29(2): 308-319, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30506551

RESUMO

The extensive research interests in environmental temperature can be linked to human productivity/performance as well as comfort and health; while the mechanisms of physiological indices responding to temperature variations remain incompletely understood. This study adopted a physiological sensory nerve conduction velocity (SCV) as a temperature-sensitive biomarker to explore the thermoregulatory mechanisms of human responding to annual temperatures. The measurements of subjects' SCV (over 600 samples) were conducted in a naturally ventilated environment over all four seasons. The results showed a positive correlation between SCV and annual temperatures and a Boltzmann model was adopted to depict the S-shaped trend of SCV with operative temperatures from 5°C to 40°C. The SCV increased linearly with operative temperatures from 14.28°C to 20.5°C and responded sensitively for 10.19°C-24.59°C, while tended to be stable beyond that. The subjects' thermal sensations were linearly related to SCV, elaborating the relation between human physiological regulations and subjective thermal perception variations. The findings reveal the body SCV regulatory characteristics in different operative temperature intervals, thereby giving a deeper insight into human autonomic thermoregulation and benefiting for built environment designs, meantime minimizing the temperature-invoked risks to human health and well-being.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Condução Nervosa/fisiologia , Temperatura Cutânea/fisiologia , Temperatura , Adulto , China , Feminino , Corpo Humano , Humanos , Modelos Lineares , Masculino , Estações do Ano , Estudantes , Universidades , Adulto Jovem
11.
Indoor Air ; 29(1): 30-42, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30379348

RESUMO

We studied dampness and mold in China in relation to rhinitis, ocular, throat and dermal symptoms, headache and fatigue. A questionnaire study was performed in six cities including 36 541 randomized parents of young children. Seven self-reported signs of dampness were evaluated. Multilevel logistic regression models were used to calculate odds ratios (ORs). Totally, 3.1% had weekly rhinitis, 2.8% eye, 4.1% throat and 4.8% skin symptoms, 3.0% headache and 13.9% fatigue. Overall, 6.3% of the homes had mold, 11.1% damp stains, 35.3% damp bed clothing, 12.8% water damage, 45.4% window pane condensation, 11.1% mold odor, and 37.5% humid air. All dampness signs were associated with symptoms (ORs from 1.2 to 4.6; P < 0.001), including rhinitis (ORs from 1.4 to 3.2; P < 0.001), and ORs increased by number of dampness signs. The strongest associations were for mold odor (ORs from 2.3 to 4.6) and humid air (ORs from 2.8 to 4.8). Associations were stronger among men and stronger in Beijing as compared to south China. In conclusion, dampness and mold are common in Chinese homes and associated with rhinitis and ocular, throat and dermal symptoms, headache and fatigue. Men can be more sensitive to dampness and health effects of dampness can be stronger in northern China.


Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados/efeitos adversos , Fungos , Umidade/efeitos adversos , Adolescente , Adulto , Poluição do Ar em Ambientes Fechados/análise , Criança , China/epidemiologia , Oftalmopatias/epidemiologia , Oftalmopatias/microbiologia , Fadiga/epidemiologia , Fadiga/microbiologia , Feminino , Fungos/isolamento & purificação , Cefaleia/epidemiologia , Cefaleia/microbiologia , Habitação , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Pais , Rinite/epidemiologia , Rinite/microbiologia , Distribuição por Sexo , Dermatopatias/epidemiologia , Dermatopatias/microbiologia , Inquéritos e Questionários , Adulto Jovem
12.
Indoor Air ; 29(2): 202-214, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30597644

RESUMO

From October 2010 to April 2012, we conducted a cross-sectional study of associations between household environments and childhood health among preschool children in eight Chinese cities. Here, we analyze associations of early household renovation with preterm birth (PTB), low birthweight (LBW), term low birthweight (Term-LBW), and small for gestational age (SGA). Parents responded to questions about household renovation and their children's gestational age and birthweight. In the multivariate logistic regression analyses, household renovation in the year before pregnancy was significantly associated with LBW (sample size: N = 25 813; adjusted odds ratio (OR) with 95% confidence intervals (CIs): 1.23, 1.01-1.50) and Term-LBW (N = 24 823; 1.29, 1.01-1.67). Household renovation during pregnancy was significantly associated with PTB (N = 25 202; 1.28, 1.01-1.69). These significant associations were also found in the two-level (city-child) logistic regression analyses and in the sensitivity analyses among 21 009 children with complete data in all studied variates. Stronger associations were found in certain subgroups. Our findings indicate that household renovation within one year before pregnancy might be a risk factor for LBW and Term-LBW, while household renovation during pregnancy could be a risk factor for PTB.


Assuntos
Materiais de Construção/efeitos adversos , Recém-Nascido de Baixo Peso , Nascimento Prematuro/etiologia , Adulto , Criança , Pré-Escolar , China/epidemiologia , Estudos Transversais , Feminino , Habitação , Humanos , Recém-Nascido Pequeno para a Idade Gestacional , Modelos Logísticos , Masculino , Gravidez , Nascimento Prematuro/epidemiologia , Fatores de Risco , Inquéritos e Questionários , Adulto Jovem
13.
Environ Res ; 167: 418-427, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30121466

RESUMO

BACKGROUND: Biomass burning is associated with childhood pneumonia but few studies exist on other indoor factors. AIM: To study pneumonia in relation to pre-natal and post-natal exposure among children across China. METHODS: Children (3-6 y) (n = 39,782) from randomized day care centres in seven cities in China. Information on pneumonia and pre-natal and post-natal exposure to home environment factors were assessed by a parental questionnaire. Life-time outdoor temperature and GDP per capita were assessed on city level. Associations were calculated by multilevel logistic regression adjusting for fourteen co-variates. RESULTS: Totally 32.0% had ever had pneumonia diagnosed by a physician. Children of farmer mothers (OR = 0.65), with breastfeeding (OR = 0.91) and living in rural (OR = 0.85) or suburban (OR = 0.90) areas had less pneumonia. Buying new furniture one year before conception (OR = 1.11) and after first year of life (OR = 1.10) increased the risk. Redecoration one year before conception (OR = 1.20), during pregnancy (OR = 1.18) and after first year of life (OR = 1.17) increased pneumonia risk. Children with mould (OR = 1.17), window pane condensation (WPC) (OR = 1.20) and mould odour (OR = 1.15) at home at birth only had a higher risk of pneumonia. Similar associations were seen for dampness and mould in the current home. Children in the oldest and newest homes had less pneumonia. Cockroaches (OR = 1.08), mosquitos or flies in the current home (OR = 1.18), an exhaust fan in the bathroom (OR = 1.10) and higher economic development level, measured as GDP per capita on city level (OR 1.11 per 10,000 RMB/year) were associated with childhood pneumonia. CONCLUSIONS: Perinatal and postnatal exposure to mould, mould odour and window pane condensation at home can be early life risk factors for childhood pneumonia in China. Moreover, pre-natal and post-natal exposure to chemical emissions from new furniture and renovation could increase the risk of childhood pneumonia. Breastfeeding, farm exposure, and living in rural or suburban areas could be protective.


Assuntos
Exposição Ambiental , Pneumonia/epidemiologia , Animais , Criança , Pré-Escolar , China/epidemiologia , Cidades , Feminino , Fungos , Humanos , Insetos , Gravidez , Fatores de Risco
14.
Ecotoxicol Environ Saf ; 163: 356-364, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30059880

RESUMO

Diisononyl phthalate (DINP) and formaldehyde both are associated with asthma and allergies. However, it is unclear about the adverse effect of DINP and formaldehyde exposure on the brain for asthma patients. Here, we determined the effect of DINP and/or formaldehyde exposure on neuroinflammation in brain by a murine asthma model and investigated the underlying mechanisms. Mice were exposed to formaldehyde and/or DINP and sensitization with ovalbumin. The results show that exposure to formaldehyde and/or DINP not only exacerbated allergic asthma-like symptoms, but also promoted neuroinflammation in brain. The incrassation of the airway wall and exacerbation of neuroinflammation were more obviously when mice were subjected to a combined exposure to DINP and formaldehyde. Exposure to DINP and/or formaldehyde enhances oxidative stress and the activation of NF-κB in the prefrontal cortex of mouse asthma model. Exposure to DINP and/or formaldehyde also induced an increase in IL-1ß, IL-17, and NGF. Blocking oxidative stress by administering melatonin or inhibiting NF-κB activation by treatment with Dehydroxymethylepoxyquinomicin effectively prevented increasing the levels IL-1ß, IL-17 and nerve growth factor. The data indicated that DINP and/or formaldehyde exposure promoted neuroinflammation in the brain through enhanced oxidative stress and activation of NF-κB in a mouse asthma model.


Assuntos
Asma/complicações , Encefalite/induzido quimicamente , Formaldeído/efeitos adversos , NF-kappa B/metabolismo , Ácidos Ftálicos/toxicidade , Hipersensibilidade Respiratória/metabolismo , Animais , Asma/induzido quimicamente , Asma/metabolismo , Modelos Animais de Doenças , Encefalite/metabolismo , Encefalite/patologia , Formaldeído/metabolismo , Formaldeído/toxicidade , Regulação da Expressão Gênica , Interleucina-17/metabolismo , Interleucina-1beta/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Fator de Crescimento Neural/metabolismo , Ovalbumina , Estresse Oxidativo/efeitos dos fármacos , Córtex Pré-Frontal/efeitos dos fármacos , Córtex Pré-Frontal/metabolismo , Córtex Pré-Frontal/patologia , Hipersensibilidade Respiratória/patologia , Transdução de Sinais
15.
Ergonomics ; 61(6): 796-805, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29287520

RESUMO

In practice, passengers actively respond to the thermal environment when they board an aircraft in winter, which is not considered in the current standards. In this study, the behavioural, physiological and psychological responses to the thermal environment were examined at 22 °C (with 68 subjects), 20 °C and 26 °C (with 32 subjects). The results showed that the three air temperature levels had significant effect on nozzle usage and clothing adjustment behaviours, surface skin temperature, and thermal sensation vote (TSV). The walking/waiting states prior to boarding the aircraft cabin had a significant effect on the proportion of jacket removal, TSV and thermal comfort vote. After 10 min in the aircraft cabin, the subjects maintained their comfort in a wider range of the thermal environment when the behavioural adjustments existed compared to when they did not. Thus, a suggestion was made for behavioural adjustments to be provided in aircraft cabins. Practitioner Summary: Experimental investigation of human responses was conducted in an aircraft cabin. Analysis showed that the subjects maintained their comfort in a wider range of the thermal environment when the behavioural adjustments existed compared to when they did not. Thus, a suggestion was made for behavioural adjustments to be provided in aircraft cabins.


Assuntos
Ar Condicionado/métodos , Aeronaves , Comportamento do Consumidor , Estações do Ano , Temperatura , Adaptação Fisiológica/fisiologia , Adaptação Psicológica/fisiologia , Adolescente , Adulto , Vestuário , Estudos Transversais , Feminino , Humanos , Masculino , Temperatura Cutânea , Adulto Jovem
16.
J Air Waste Manag Assoc ; 65(1): 11-26, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25946954

RESUMO

The management of waste electronic and electrical equipment (WEEE) is a major challenge in developing and transition countries. The paper investigates recent strategies to manage this waste stream in an environmentally sound way. Obsolete electrical and electronic equipment (EEE) are a complex waste category containing both hazardous and valuable substances. Many countries and regions in the world are undertaking extensive scientific research to plan and develop effective collection and treatment systems for end-of-life EEE. In developing countries such as Botswana, effective strategies that cover all stages throughout the lifecycle of products, particularly at the end-of-life, still lag behind. Infrastructure, pre-processing, and end-processing facilities and innovative technologies for end-of-life management of e-waste are noticeably absent due to lack of investment and high costs of its management. The objective of the paper is to present the e-waste situation in Botswana, highlighting (a) measures taken in the form of legislative and policy regulations; (b) existing practices to manage e-waste; and (c) effective solutions for e-waste management in emerging economies. Studies from other countries on e-waste management issues provided insights on the "best" technical and logistical pre-processing and end-processing strategies to treat hazardous waste. The paper also highlights key societal factors that affect successful implementation of cost-effective collection and value recovery of end-of-life EEE. These include unavailability of national "e-waste policy," absence of formal take-back system, absence of financing and subsidies, inadequate source separation programmes, absence of technical and logistical integration of pre-processing and end-processing facilities, and limited infrastructure and access to technologies and investment. Effective strategies such as an "integrated approach" (mixed options), access to technologies, establishment of pre-processing and end-processing facilities and optimization of logistics, optimizing diversion of e-waste from disposal sites, and investment in e-waste are suggested to manage this complex waste stream in an environmentally sound way.


Assuntos
Países em Desenvolvimento , Resíduo Eletrônico , Gerenciamento de Resíduos/métodos , Botsuana , Gerenciamento de Resíduos/legislação & jurisprudência
17.
Arch Environ Contam Toxicol ; 68(1): 20-30, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25038721

RESUMO

An investigation was performed to identify the sources of arsenic (As) and heavy metals in house dust and to assess the associated human health risks in the vicinity of phosphorus (P) mining in Guizhou, China. The concentrations and spatial distributions of mercury (Hg), As, cadmium (Cd), lead (Pb), iron (Fe), copper (Cu), manganese (Mn), and P in 23 house dust samples from the study area were determined. Greater concentrations of As and Pb were found compared with values in other investigations in various countries. Pollution sources were identified using multivariate statistical analysis. As, Pb, Mn, and Hg pollution was mainly attributed to mining activities, and Mn and Cd levels were largely associated with automobile emissions. The dominant wind direction and the distance of the residence from the mining region were found to play an important role in element distributions. A health risk assessment showed that As and Pb should be paid more attention, although the noncancer risks of the studied elements were within the safe range and the cancer risks of As and Cd are within the acceptable range under present conditions.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Poeira/análise , Exposição Ambiental/análise , Poluição Ambiental/estatística & dados numéricos , Metais/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , China , Exposição Ambiental/estatística & dados numéricos , Habitação/estatística & dados numéricos , Humanos , Mineração , Fósforo , Medição de Risco
18.
Waste Manag Res ; 32(12): 1158-68, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25432741

RESUMO

Hazardous and toxic waste is a complex waste category because of its inherent chemical and physical characteristics. It demands for environmentally sound technologies and know-how as well as clean technologies that simultaneously manage and dispose it in an environmentally friendly way. Nevertheless, Botswana lacks a system covering all the critical steps from importation to final disposal or processing of hazardous and toxic waste owing to limited follow-up of the sources and types of hazardous and toxic waste, lack of modern and specialised treatment/disposal facilities, technical know-how, technically skilled manpower, funds and capabilities of local institutions to take lead in waste management. Therefore, because of a lack of an integrated system, there are challenges such as lack of cooperation among all the stakeholders about the safe management of hazardous and toxic waste. Furthermore, Botswana does not have a systematic regulatory framework regarding monitoring and hazardous and toxic waste management. In addition to the absence of a systematic regulatory framework, inadequate public awareness and dissemination of information about hazardous and toxic waste management, slower progress to phase-out persistent and bio-accumulative waste, and lack of reliable and accurate information on hazardous and toxic waste generation, sources and composition have caused critical challenges to effective hazardous and toxic waste management. It is, therefore, important to examine the status of hazardous and toxic waste as a waste stream in Botswana. By default; this mini-review article presents an overview of the current status of hazardous and toxic waste management and introduces the main challenges in hazardous and toxic waste management. Moreover, the article proposes the best applicable strategies to achieve effective hazardous and toxic waste management in the future.


Assuntos
Substâncias Perigosas/antagonistas & inibidores , Gerenciamento de Resíduos/normas , Botsuana , Resíduos Perigosos/análise
19.
Sci Total Environ ; 946: 173898, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38866141

RESUMO

This paper investigates the impact of children's recess activity patterns on particulate matter (PM) resuspension in indoor environments, highlighting the complex, multi-dimensional nature of these activities and their interaction with environmental parameters. Despite the recognized role of indoor human activity in PM resuspension, research specifically addressing the effects of children's movements has been sparse. Through experimental scenarios that account for the characteristics of student activities, such as movement speed, trajectory, the number of participants, aisle widths, and varying humidity levels, this study uncovers significant differences in PM resuspension rates. It reveals that not only do movement speed and trajectory have a profound impact, but also the interaction between humidity and these factors plays a critical role, especially under lower humidity conditions. Additionally, the study demonstrates how the combination of people density and spatial configurations can significantly influence resuspension rates. The findings offer valuable insights for designing strategies to mitigate particle pollution in classrooms and similar indoor environments.

20.
Comput Biol Med ; 172: 108262, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38479196

RESUMO

Given the increasing aging population and rising living standards in China, developing an accurate and straightforward thermoregulation model for the elderly has become increasingly essential. To address this need, an existing one-segment four-node thermoregulation model for the young was selected as the base model. This study developed the base model considering age-related physical and physiological changes to predict mean skin temperatures of the elderly. Measured data for model optimization were collected from 24 representative healthy Chinese elderly individuals (average age: 67 years). The subjects underwent temperature step changes between neutral and warm conditions with a temperature range of 25-34 °C. The model's demographic representation was first validated by comparing the subjects' physical characteristics with Chinese census data. Secondly, sensitivity analysis was performed to investigate the influences of passive system parameters on skin and core temperatures, and adjustments were implemented using measurement or literature data specific to the Chinese elderly. Thirdly, the active system was modified by resetting the body temperature set points. The active parameters to control thermoregulation activities were further optimized using the TPE (Tree-structured Parzen Estimator) hyperparameter tuning method. The model's accuracy was further verified using independent experimental data for a temperature range of 18-34 °C for Chinese elderly. By comprehensively considering age-induced thermal response changes, the proposed model has potential applications in designing and optimizing thermal management systems in buildings, as well as informing energy-efficient strategies tailored to the specific needs of the Chinese elderly population.


Assuntos
Temperatura Alta , Modelos Biológicos , Humanos , Idoso , Regulação da Temperatura Corporal/fisiologia , Temperatura Corporal/fisiologia , Temperatura Cutânea , China
SELEÇÃO DE REFERÊNCIAS