Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Zhonghua Yi Xue Za Zhi ; 90(6): 403-6, 2010 Feb 09.
Artigo em Chinês | MEDLINE | ID: mdl-20367940

RESUMO

OBJECTIVE: To investigate the migration and distribution of CTL (cytotoxic T lymphocyte) and CIK (cytokine-induced killer) cells in gastric tumor model. METHODS: Subcutaneous gastric tumor model was established by BGC-823 cancer cells in nude mice. Both CTL and CIK cells were labeled with 99Tc(m) directly and then inoculated into nude mice with subcutaneous tumor by intravenous injection separately. Three mice of each group were evaluated by single-photon emission computerized tomography (SPECT) at 1 h, 6 h and 24 h post-inoculation. After SPECT imaging, 3 mice in each group were sacrificed and got samples of the tumor, liver, spleen, kidney, lung, intestine, etc. The tissue samples were weighed and radioactivity was determined with a well-type scintillation counter. The accumulation of labeled CTL and CIK cells in tissues were expressed as %ID/g (percentage activity of injection dose per gram of tissue) and T/NT (tumor/non-tumor) values were analyzed. RESULTS: The tracing of both cells in SPECT showed a clear migration path away from the injection point to solid tumor, and can be detected in all organs and tissues such as liver, spleen, kidney, lung and intestine, etc not long after injection. The %ID/g peak values of CTL in organs from the highest to the lowest were as follows: tumor (7.79 +/- 0.46), liver (4.12 +/- 0.51), intestine (2.71 +/- 0.16), kidney (1.44 +/- 0.25), spleen (1.24 +/- 0.12), kidney (1.12 +/- 0.11), and all the T/NTs were above 1. The %ID/g peak values of CIK cells in organs from the highest to the lowest were as follows: liver (6.64 +/- 0.67), tumor (5.47 +/- 0.87), intestine (3.55 +/- 0.23), kidney (2.34 +/- 0.41), spleen (1.45 +/- 0.17), lung (1.27 +/- 0.21), and T/NTs > 1 except for liver. After injection, the %ID/g values of tumor in CTL group were 2.35 +/- 0.28 (1 h), 4.58 +/- 0.52 (6 h) and 7.79 +/- 0.46 (24 h) respectively while the %ID/g values of tumor in CIK group 2.23 +/- 0.46 (1 h), 3.25 +/- 0.70 (6 h) and 5.47 +/- 0.87 (24 h) respectively. At 24 h point, the %ID/g of CTL in tumor was much higher than CIK cells (P < 0.05). CONCLUSION: The definite directional tumor-targeting capacity of CTL and CIK cells in tumor-bearing nude mice is promising.


Assuntos
Movimento Celular , Células Matadoras Induzidas por Citocinas/citologia , Neoplasias Gástricas/imunologia , Linfócitos T Citotóxicos/citologia , Animais , Linhagem Celular Tumoral , Células Matadoras Induzidas por Citocinas/imunologia , Feminino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Transplante de Neoplasias , Linfócitos T Citotóxicos/imunologia , Tomografia Computadorizada de Emissão de Fóton Único
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 30(6): 1702-6, 2010 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-20707180

RESUMO

Prism is one of the most key parts in the hyper spectral imager (HSI). Consequently, to set thermal control target and make thermal control design, the thermal spectral property of prism in the HSI was studied. The working principle of the HSI and the definition of its thermal spectral property were introduced. The working environment of prism and its thermal effect were analyzed; also the study contents and technical route of the prism's thermal spectral property were discussed. The effects of different uniform temperature field on deflexion angle and angular dispersion of the prism in the HSI were deduced, and the changes in displacement of the spectra and the spectral bandwidth under different uniform temperature were obtained. For one instance, the thermal spectral property of the K9 prism and the fused silica prism were compared based on FEM and combined experiments, furthermore, its thermal control target was ascertained and a thermal spectral property test was carried out to validate the rationality of the thermal spectral property analysis. The results of analysis indicated that the changes in spectral bandwidth and spectrum resolution brought by thermal distortions can be ignored according to current fixing mode, and the displacement of the spectra is mainly determined by thermal coefficient of material refractive index; because of it's the lower thermal coefficient of material refractive index, the displacement of the spectra of the K9 prism is smaller under the same temperature changes; the material deflexion changes (dn/dlambda) of prism are not sensitive to the temperature, so the changes in spectral bandwidth caused by them are not obvious. And the results of test proved that the studied method of thermal spectral property is reasonable and essential, and the results are authentic and credible. So it can provide some guidance for setting thermal control target and optimizing thermal control design.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA