Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ultrasound Med Biol ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38871491

RESUMO

OBJECTIVE: The purpose of the study described was to establish prediction models to initially screen the beneficiary patients with unresectable hepatocellular carcinoma (HCC) in the treatment of anti-vascular endothelial growth factor (VEGF) agents plus anti-programmed cell death-1 (PD-1) antibody. METHODS: A total of 62 patients were enrolled in this study. All patients underwent ultrasound (US), color ddoppler flowing imaging (CDFI), contrast-enhanced ultrasound (CEUS) and laboratory examinations within 2 wk before the treatment. Tumor response was assessed according to mRECIST criteria. Univariate and multivariate analyses were used to select the independent predictors. US + CDFI, CEUS and FULL models were established. Three models were displayed by nomography. Receiver operating characteristic (ROC) and calibration curves were drawn to evaluate the predictive ability of models. Decision curve analysis (DCA) was used to assess the clinical utility of models. RESULTS: On univariate and multivariate analysis, the US boundary (p = 0.037), halo (p = 0.002) and CDFI (p = 0.024) were included in the US + CDFI model. CEUS boundary (p = 0.001) and washout time (p < 0.001) were included in the CEUS model. The number of lesions (p = 0.104), halo on US (p = 0.014), CDFI (p = 0.057) and washout time on CEUS (p = 0.015) were incorporated into the FULL model. The C indices of the US + CDFI, CEUS and FULL models were 0.918, 0.920 and 0.973. CEUS and FULL models yielded a good net benefit for almost all threshold probabilities. CONCLUSION: Nomograms based on US, CDFI, CEUS and clinical characteristics could help to non-invasively predict the response to treatment with anti-PD-1 antibodies plus anti-VEGF agents.

2.
Front Oncol ; 13: 1207902, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38273854

RESUMO

Objective: The purpose of this study was to investigate the added value of color parameter imaging (CPI) in the differential diagnosis of focal liver lesions (FLLs) with "homogeneous hyperenhancement but not wash out" on contrast-enhanced ultrasound (CEUS). Methods: A total of 101 patients with 108 FLLs were enrolled in this study. All the FLLs received US and CEUS examinations. The stored CEUS clips of target lesions were postprocessed with CPI analysis by radiologists. The receiver operator characteristic (ROC) curve was used to evaluate the added value of CPI. The McNamara test was used to compare the diagnostic sensitivity, specificity, and accuracy between CEUS and CPI patterns. Univariate and multivariate logistic regression analyses were used to develop a CPI nomogram. The C index and calibration curve were used to evaluate the predictive ability of the nomogram. The intraclass correlation coefficient was used to test the reproducibility and reliability of CPI. Decision curve analysis (DCA) was used to evaluate the added value of applying CPI. Results: The following CPI features were more frequently observed in malignant FLLs: eccentric perfusion (malignant: 70.0% vs. benign: 29.2%, p < 0.001), feeding artery (51.7% vs. 4.2%, p < 0.001), mosaic (63.3% vs. 6.3%, p < 0.001), red ingredients >1/3 (90.0% vs. 14.6%, p < 0.001). In addition, centripetal (43.8% vs. 18.3%, p = 0.004), peripheral nodular (54.2% vs. 1.7%, p < 0.001), subcapsular vessel (12.5% vs. 0.0%, p = 0.004), spoke-wheel vessels (25.0% vs. 5.0%, p = 0.003), branched vessels (22.9% vs. 5.0%, p = 0.006), blue and pink ingredients >2/3 (85.4% vs. 10.0%, p < 0.001) were more observed in benign FLLs. A nomogram incorporating peripheral nodular, spoke-wheel vessels, and red ingredients >1/3 was constructed. The model had satisfactory discrimination (AUC = 0.937), and the optimal diagnostic threshold value was 0.740 (0.983, 0.850). By the DCA, the model offered a net benefit over the treat-all-patients scheme or the treat-none scheme at a threshold probability 5%-93%. Conclusion: Using CPI can detect and render subtle information of the main features of FLLs on CEUS; it is conducive to the radiologist for imaging interpretation, and a combining read of the CEUS and CPI of the FLLs with features of "homogenous hyperenhancement and no washout" can improve significantly the diagnostic performance of CEUS for FLLs.

3.
Ultrasound Med Biol ; 48(8): 1555-1566, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35597704

RESUMO

Computer-aided color parameter imaging (CPI) is a novel technique for contrast-enhanced ultrasound (CEUS) that can highlight hemodynamic features of focal lesions. The purpose of the study was to investigate the role of CPI in evaluation of hepatocellular carcinoma (HCC) hemodynamic features and prognosis after radiofrequency ablation (RFA). One hundred twenty-one patients with HCC underwent CEUS with CPI analysis before RFA. Eighty-nine patients had pathologically proven well- to moderately differentiated HCC (WM-HCC), and 32 patients had poorly differentiated or undifferentiated HCC (PU-HCC). Perfusion features of CEUS and contrast-enhanced computed tomography/magnetic resonance imaging were compared with CPI parameters for WM-HCC and PU-HCC. The results indicated that 67.4% of WM-HCC had a centrifugal perfusion CPI pattern, whereas 84.4% of PU-HCC tumors had a centripetal pattern (p < 0.001, odds ratio = 11.2). The specificity, sensitivity and accuracy of the CPI perfusion pattern regarding HCC pathological grade were higher than those with routine CEUS (84.4% vs. 9.4%, p < 0.001; 67.4% vs. 3.4%, p < 0.001; 71.9% vs. 5.0%, p < 0.001). Moreover, multivariable analysis revealed that the CPI perfusion pattern was an independent risk factor for progression-free survival post-RFA (centripetal group: 28.3 ± 4.1 mo vs. centrifugal group: 45.8 ± 4.4 mo, p = 0.002). A novel CPI technique for CEUS could non-invasively provide valuable hemodynamic information and predict prognosis for HCC patients treated by RFA.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Computadores , Meios de Contraste , Hemodinâmica , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Ultrassonografia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA