Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 315
Filtrar
1.
BJU Int ; 133(2): 141-151, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37461135

RESUMO

OBJECTIVE: To investigate the feasibility, safety and efficacy of holmium laser enucleation of the prostate (HoLEP) in the re-treatment setting (salvage HoLEP) and compare it to the primary HoLEP procedure that is commonly used for the treatment of benign prostate hyperplasia (BPH). MATERIALS AND METHODS: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement, PubMed, Scopus, and Cochrane databases were systematically screened, from inception to 8 August 2022. Other potentially eligible studies were retrieved using the reference lists of the included studies. Retrospective and prospective studies, both comparative and non-comparative, were included. RESULTS: A total of 12 studies met the inclusion criteria and were included in the final qualitative synthesis. One study was prospective comparative (non-randomised), seven studies were retrospective comparative, and four studies were retrospective non-comparative or case series. In total, 831 patients were treated with salvage HoLEP in the above studies. Previous intervention before salvage HoLEP ranged among studies. The most commonly performed was transurethral resection of the prostate. Intraoperative parameters of salvage HoLEP were comparable with those reported during primary HoLEP, while all postoperative outcomes were significantly improved after salvage HoLEP and were similar with those observed after primary HoLEP. No major complications were noted after salvage HoLEP according to Clavien-Dindo classification. CONCLUSIONS: Salvage HoLEP after previous interventions for treating recurrent or residual BPH is a feasible, safe, and efficient procedure. Data presented in selected studies, along with the holmium laser's physical properties to resect more tissue and to dissect along the true anatomical plane of BPH, render HoLEP an ideal salvage treatment modality for recurrent or residual BPH symptoms.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Humanos , Masculino , Hólmio , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Estudos Prospectivos , Próstata , Hiperplasia Prostática/complicações , Estudos Retrospectivos , Ressecção Transuretral da Próstata/métodos , Resultado do Tratamento
2.
World J Urol ; 42(1): 33, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217743

RESUMO

PURPOSE: To identify laser lithotripsy settings used by experts for specific clinical scenarios and to identify preventive measures to reduce complications. METHODS: After literature research to identify relevant questions, a survey was conducted and sent to laser experts. Participants were asked for preferred laser settings during specific clinical lithotripsy scenarios. Different settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-six laser experts fully returned the survey. Holmium-yttrium-aluminum-garnet (Ho:YAG) was the primary laser used (88%), followed by thulium fiber laser (TFL) (42%) and pulsed thulium-yttrium-aluminum-garnet (Tm:YAG) (23%). For most scenarios, we could not identify relevant differences among laser settings. However, the laser power was significantly different for middle-ureteral (p = 0.027), pelvic (p = 0.047), and lower pole stone (p = 0.018) lithotripsy. Fragmentation or a combined fragmentation with dusting was more common for Ho:YAG and pulsed Tm:YAG lasers, whereas dusting or a combination of dusting and fragmentation was more common for TFL lasers. Experts prefer long pulse modes for Ho:YAG lasers to short pulse modes for TFL lasers. Thermal injury due to temperature development during lithotripsy is seriously considered by experts, with preventive measures applied routinely. CONCLUSIONS: Laser settings do not vary significantly between commonly used lasers for lithotripsy. Lithotripsy techniques and settings mainly depend on the generated laser pulse's and generator settings' physical characteristics. Preventive measures such as maximum power limits, intermittent laser activation, and ureteral access sheaths are commonly used by experts to decrease thermal injury-caused complications.


Assuntos
Alumínio , Lasers de Estado Sólido , Litotripsia a Laser , Urolitíase , Ítrio , Humanos , Túlio , Urolitíase/cirurgia , Litotripsia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Tecnologia , Hólmio
3.
World J Urol ; 41(12): 3503-3510, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37878061

RESUMO

PURPOSE: To summarize all existing evidence regarding the feasibility, safety, and efficacy of same-day trial of void and catheter removal after Holmium Laser Enucleation of the Prostate (HoLEP). Although there have been many reports of the safety and efficacy of same-day discharge from the hospital for selected patients undergoing HoLEP, in most of these reports, patients return to the hospital, usually on postoperative day one, to undergo a trial of void and catheter removal. METHODS: PubMed®, Scopus®, and Cochrane® primary databases were systematically screened, from inception to 17 January 2023. The search strategy used the PICO (Patient, Intervention, Comparison, Outcomes) Framework. We followed the recommendations of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. RESULTS: Six studies met all the predefined criteria and were included in the final qualitative synthesis. Four studies were retrospective and two were prospective. Four studies were non-comparative, while two were comparative ones. The same-day catheter removal success rate ranged from 85.5 to 90% among studies, while only one grade-IIIb Clavien-Dindo complication was reported, which was unrelated to surgery. CONCLUSION: Same-day catheter removal is a feasible, safe, and efficient approach for selected patients undergoing HoLEP. Certain factors, such as intraoperative furosemide administration, were found to improve same-day catheter-free rates, while preoperative PVR and urinary retention were independent predictive factors of same-day trial of void failure.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Próstata , Estudos Retrospectivos , Estudos Prospectivos , Hólmio , Lasers de Estado Sólido/uso terapêutico , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/complicações , Qualidade de Vida , Resultado do Tratamento
4.
World J Urol ; 41(11): 3155-3160, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37668715

RESUMO

PURPOSE: This pilot study was designed to interpret the technically specific features of the avatera robotic system and present our initial experience with this novel platform in robot-assisted pyeloplasty (RAP). METHODS: A single-center prospective study was conducted including all patients who underwent RAP with the avatera robotic system from June 2022 to October 2022 in our Department. Transperitoneal robot-assisted dismembered pyeloplasty was performed in all cases. The trocar placement and the surgical technique were similar in all patients. The successful completion of the procedures, operation time (including draping, docking and console time), decrease in hemoglobin postoperatively, and presence of any complications were the study's primary endpoints. RESULTS: In total, nine patients underwent RAP using the avatera system. All procedures were successfully completed. The draping of the robotic unit was completed in a median time of 10 min (range 7-15), while the median docking time was 17 min (range 10-24). The median console time was 88 min (range 78-116) and no complications were noticed. The median hemoglobin drop was calculated to 0.7 g/dL (range 0.4-1). During the mean follow-up of 9.33 ± 2.78 months, no late postoperative complications were noticed. CONCLUSION: The early outcomes of the use of the novel avatera system in RAP are presented. All operations were successfully completed with safety and efficacy, without complications or significant blood loss.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Obstrução Ureteral , Humanos , Robótica/métodos , Estudos Prospectivos , Projetos Piloto , Resultado do Tratamento , Obstrução Ureteral/cirurgia , Procedimentos Cirúrgicos Urológicos/métodos , Hemoglobinas , Laparoscopia/métodos , Pelve Renal/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos
5.
World J Urol ; 41(9): 2473-2479, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37450005

RESUMO

PURPOSE: To compare the perioperative and postoperative outcomes between Oyster prostate vaporesection using Tm-YAG laser and the conventional transurethral prostatectomy using monopolar energy. METHODS: Patients with LUTS with an accumulative size of at least 60 ml were randomly assigned to one of two parallel groups to undergo Tm-YAG laser vaporesection (Group 1) or conventional monopolar transurethral prostatectomy (Group 2). The primary endpoints were the reduction in IPSS and the increase in Qmax postoperatively. Secondary endpoints included the Hemoglobin drop, the complication rate, the changes in urodynamic parameters, the duration of hospitalization and catheterization and the changes in IIEF during the 24-month follow-up. RESULTS: In total 32 and 30 patients were enrolled in Groups 1 and 2, respectively. Patient age (p = 0.422) and prostate volume were similar among the groups (p = 0.51). The outcomes in terms of IPSS decrease and Qmax amelioration were comparable (p = 0.449 and p = 0.237, respectively). Operative and hospitalization times were lower in Group 1 (p = 0.002 and p = 0.004, respectively). Hemoglobin drop, changes in urodynamic parameters and improvement in IIEF and QoL scores did not differ among the two Groups. The average time with the catheter was 2.06 ± 0.35 and 2.5 ± 0.82 (p = 0.003) days for Group 1 and Group 2, respectively. The overall complication rate was 6.2% for Group 1 and 13.3% for Group 2. CONCLUSIONS: The Oyster technique leads to similar postoperative outcomes compared to the standard monopolar transurethral prostatectomy. The shorter catheterization, hospitalization and operation time should be considered advantages of the Oyster technique.


Assuntos
Terapia a Laser , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Ressecção Transuretral da Próstata/métodos , Túlio , Qualidade de Vida , Resultado do Tratamento , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/complicações , Prostatectomia/métodos , Hemoglobinas , Terapia a Laser/métodos
6.
World J Urol ; 41(2): 581-587, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36547678

RESUMO

PURPOSE: To evaluate the effectiveness and safety of non-papillary prone PCNL for the treatment of patients with renal abnormalities. METHODS: An observational retrospective cohort study including PCNL cases of patients with renal abnormalities was performed. The following inclusion criteria were applied: renal stones > 1.5 cm with maximal diameter, anatomical malformations of affected kidney (malrotated kidneys, horseshoe kidneys and kidneys with complete duplicated systems, medullary sponge kidney), patients treated with standard (30Fr) PCNL or mini-PCNL (22Fr). The lithotripsy was performed using the Lithoclast Master or the Lithoclast® Trilogy (EMS Medical, Nyon, Switzerland). RESULTS: Overall, 57 patients, 35 males, and 22 females with any renal malformation underwent non-papillary prone PCNL. Our study included 25 patients with horseshoe kidneys, 21 with malrotated kidneys, 9 with kidneys with duplicated pelvicalyceal systems and 2 with medullary sponge kidneys. The mean cumulative stone size was 36 ± 1.4 mm and most of the stones were in the lower calyceal group (36.9%) and in the pelvis (27.2%). The stone-free rate (SFR) was 84.2% and the mean hospitalization time was 2.7 ± 0.7 days. In total, postoperative complications were developed in six patients (10.5%), half of them presenting fever and the other half requiring blood transfusion (Grade II). CONCLUSION: The PCNL is the method of choice for treating large stones in anomalous kidneys. The generally accepted panacea that only a papillary puncture is safe is questioned by our results. Based on our experience, a non-papillary puncture proved to be a safe and effective procedure.


Assuntos
Rim Fundido , Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Masculino , Feminino , Humanos , Estudos Retrospectivos , Nefrostomia Percutânea/métodos , Rim/anormalidades , Resultado do Tratamento
7.
World J Urol ; 41(5): 1415-1421, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37024556

RESUMO

PURPOSE: To report our experience in the management of encrusted ureteral stents (EUS) and provide technical insight of our endourological approaches for difficult scenarios posed by this entity. MATERIALS AND METHODS: A retrospective evaluation of a longitudinally collected database of 58 patients with encrusted US between December 2012 and May 2022 was performed. The ureteral stents were initially inserted due to obstructive uropathy, pyelonephritis or after a successful endoscopic procedure for urolithiasis. A combination of antegrade/retrograde treatment in single or multiple sessions took place for the retrieval of the encrusted stents. Non-contrast enhanced computer tomography was used for the follow-up of the patients at 1-month after the removal of the encrusted stent. RESULTS: Overall 58 patients, 39 males and 19 females with a median age of 51 years old were included in the study. Indwelling time was < 6 months, 6-12 months and > 12 months in 22%, 57% and 21% of the cases, respectively. All US were successfully removed. Semi-rigid ureteroscopy (URS) and flexible ureteroscopy (fURS) were used in 90% of the cases. In 10% of the cases, a second-stage percutaneous nephrolithotomy (PCNL) or endoscopic combined intrarenal surgery (ECIRS) was performed. All US were successfully released. Stone-free rate was 84% at 1-month. Overall complication rate was 10.5% (mostly postoperative fevers, 5.4%). CONCLUSION: Removal of the encrusted US is a challenging procedure. Appropriate decision-making and knowledge of specific tricks may result in safe and successful management of significant EUS.


Assuntos
Litotripsia , Ureter , Cálculos Ureterais , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Ureteroscopia/métodos , Estudos Retrospectivos , Litotripsia/métodos , Remoção de Dispositivo/métodos , Ureter/cirurgia , Cálculos Ureterais/cirurgia , Stents/efeitos adversos
8.
World J Urol ; 41(10): 2617-2625, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35567624

RESUMO

PURPOSE: We aimed to examine how different endoscopic bladder tumor resection techniques affect pathologists' clinical practice patterns. METHODS: An online survey including 28 questions clustered in four main sections was prepared by the ESUT ERBT Working Group and released to the pathologists working in the institutions of experts of the ESUT Board and the working groups and experts in the uropathology working group. A descriptive analysis was performed using the collected data. RESULTS: Sixty-eight pathologists from 23 countries responded to the survey. 37.3% of the participants stated that they always report the T1 sub-staging. Of those who gave sub-staging, 61.3% used T1a, b. 85.2% think that en bloc samples provide spatial orientation faster than piecemeal samples, and 60% think en bloc samples are timesaving during an inspection. 55.7% stated that whether the tissue sample is en bloc or piecemeal is essential. 57.4% think en bloc sample reduces turnaround time and is cost-effective for 44.1%. A large number of pathologists find that the pathology examination of piecemeal samples has a longer learning curve. CONCLUSION: The survey shows that pathologists think that they can diagnose faster, accurately, and cost-effectively with ERBT samples, but they do not often encounter them in practice. Moreover, en bloc samples may be a better choice in pathology resident training. Evidence from real-life observational pathology practice and clinical research can reveal the current situation more clearly and increase awareness on proper treatment in endoscopic management of bladder tumors.


Assuntos
Neoplasias da Bexiga Urinária , Humanos , Neoplasias da Bexiga Urinária/cirurgia , Neoplasias da Bexiga Urinária/patologia , Análise de Custo-Efetividade
9.
World J Urol ; 41(2): 477-482, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36577927

RESUMO

PURPOSE: To investigate the feasibility of the avatera system for performing robot-assisted radical cystectomy (RARC) followed by intracorporeal reconstruction of ileal neobladder. METHODS: Six anesthetized female pigs were used to perform RARC and formation of the intracorporeal orthotopic ileal neobladder. Three surgeons with different level of expertise in the use of robotic systems performed RARC after a short instructional lecture and a 2-h hands-on training. The urinary diversion phase was performed only by the experienced surgeon. The successful completion of the procedure, operative time for demolitive and reconstructive phases, intraoperative blood loss and malfunction of the robotic system were evaluated. RESULTS: An improvement of the operative time was observed for each surgeon. The experienced surgeon, the fellow and the resident improved their time by 11, 15, and 22 min, respectively, between the first and the second RARC performed. The most significant time difference was demonstrated by the resident, who had no previous experience in using robotic systems. The time difference between the first and the last orthotopic ileal neobladder creation for the experienced surgeon was 51 min. CONCLUSION: The feasibility of avatera system for performing complex surgical procedure such as RARC with intracorporeal neobladder formation was demonstrated by this experimental study. No major bleeding or severe malfunctions were observed during the procedures. Significant improvement in operative time was demonstrated with the increasing experience from 1st to 6th case.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Neoplasias da Bexiga Urinária , Derivação Urinária , Feminino , Animais , Suínos , Cistectomia/métodos , Neoplasias da Bexiga Urinária/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Derivação Urinária/métodos , Procedimentos Cirúrgicos Robóticos/métodos
10.
World J Urol ; 41(11): 3277-3285, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37632557

RESUMO

PURPOSE: To identify expert laser settings for BPH treatment and evaluate the application of preventive measures to reduce complications. METHODS: A survey was conducted after narrative literature research to identify relevant questions regarding laser use for BPH treatment (59 questions). Experts were asked for laser settings during specific clinical scenarios. Settings were compared for the reported laser types, and common settings and preventive measures were identified. RESULTS: Twenty-two experts completed the survey with a mean filling time of 12.9 min. Ho:YAG, Thulium fiber laser (TFL), continuous wave (cw) Tm:YAG, pulsed Tm:YAG and Greenlight™ lasers are used by 73% (16/22), 50% (11/22), 23% (5/22), 13.6% (3/22) and 9.1% (2/22) of experts, respectively. All experts use anatomical enucleation of the prostate (EEP), preferentially in one- or two-lobe technique. Laser settings differ significantly between laser types, with median laser power for apical/main gland EEP of 75/94 W, 60/60 W, 100/100 W, 100/100 W, and 80/80 W for Ho:YAG, TFL, cwTm:YAG, pulsed Tm:YAG and Greenlight™ lasers, respectively (p = 0.02 and p = 0.005). However, power settings within the same laser source are similar. Pulse shapes for main gland EEP significantly differ between lasers with long and pulse shape modified (e.g., Moses, Virtual Basket) modes preferred for Ho:YAG and short pulse modes for TFL (p = 0.031). CONCLUSION: Ho:YAG lasers no longer seem to be the mainstay of EEP. TFL lasers are generally used in pulsed mode though clinical applicability for quasi-continuous settings has recently been demonstrated. One and two-lobe techniques are beneficial regarding operative time and are used by most experts.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Litotripsia a Laser , Hiperplasia Prostática , Masculino , Humanos , Litotripsia a Laser/métodos , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/tratamento farmacológico , Próstata , Lasers de Estado Sólido/uso terapêutico , Hipertrofia/tratamento farmacológico , Hipertrofia/cirurgia , Túlio/uso terapêutico , Terapia a Laser/métodos
11.
World J Urol ; 41(11): 3367-3376, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37777981

RESUMO

PURPOSE: To highlight and compare experts' laser settings during endoscopic laser treatment of upper tract urothelial carcinoma (UTUC), to identify measures to reduce complications, and to propose guidance for endourologists. METHODS: Following a focused literature search to identify relevant questions, a survey was sent to laser experts. We asked participants for typical settings during specific scenarios (ureteroscopy (URS), retrograde intrarenal surgery (RIRS), and percutaneous treatment). These settings were compared among the reported laser types to find common settings and limits. Additionally, we identified preventive measures commonly applied during surgery. RESULTS: Twenty experts completed the survey, needing a mean time of 12.7 min. Overall, most common laser type was Holmium-Yttrium-Aluminum-Garnet (Ho:YAG) (70%, 14/20) followed by Thulium fiber laser (TFL) (45%, 9/20), pulsed Thulium-Yttrium-Aluminum-Garnet (Tm:YAG) (3/20, 15%), and continuous wave (cw)Tm:YAG (1/20, 5%). Pulse energy for the treatment of distal ureteral tumors was significantly different with median settings of 0.9 J, 1 J and 0.45 J for Ho:YAG, TFL and pulsed Tm:YAG, respectively (p = 0.048). During URS and RIRS, pulse shapes were significantly different, with Ho:YAG being used in long pulse and TFL in short pulse mode (all p < 0.05). We did not find further disparities. CONCLUSION: Ho:YAG is used by most experts, while TFL is the most promising alternative. Laser settings largely do not vary significantly. However, further research with novel lasers is necessary to define the optimal approach. With the recent introduction of small caliber and more flexible scopes, minimal-invasive UTUC treatment is further undergoing an extension of applicability in appropriately selected patients.


Assuntos
Carcinoma de Células de Transição , Lasers de Estado Sólido , Litotripsia a Laser , Neoplasias da Bexiga Urinária , Humanos , Carcinoma de Células de Transição/cirurgia , Lasers de Estado Sólido/uso terapêutico , Túlio , Hólmio
12.
Curr Opin Urol ; 33(2): 116-121, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36305308

RESUMO

PURPOSE OF REVIEW: Percutaneous nephrolithotomy (PCNL) constitutes the gold standard procedure for patients suffering from more than 2 cm renal stones. The puncture is a very critical step of PCNL, affecting manoeuvrability of the nephroscope, possibility to remove stone fragments, risk of bleeding and radiation exposure. The aim of the current review was to discuss the advances in percutaneous renal puncture. RECENT FINDINGS: Following technological evolution in medicine, there was a consistent development in the puncture techniques, aiming at the improvement of its efficacy and safety. The use of specific agents can improve ultrasonic guidance, making the challenging step of gaining access to the kidney easier for the experienced surgeon and more accessible for the resident urologist. Future developments in the electromagnetic and three-dimensional (3D) technology may establish a high level of accuracy with decreased rates of related complications, even in the hands of beginners. SUMMARY: The advances in percutaneous puncture can lead to improved safety and accuracy of this procedure decreasing the radiation exposure and the complication rate.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Humanos , Nefrostomia Percutânea/efeitos adversos , Nefrostomia Percutânea/métodos , Rim/diagnóstico por imagem , Rim/cirurgia , Punções/métodos , Cálculos Renais/cirurgia , Nefrolitotomia Percutânea/efeitos adversos , Nefrolitotomia Percutânea/métodos , Resultado do Tratamento
13.
World J Urol ; 40(1): 283-289, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34424374

RESUMO

PURPOSE: To evaluate the potential opportunities and possible competitiveness of Avatera robotic system (ARS) (Avateramedical, Germany), and perform predictive cost-analysis for its implementation and dissemination. MATERIAL AND METHODS: Our study employed a projective quantitative research design. SWOT (strengths, weaknesses, opportunities, threats) analysis was used to map ARS internal competencies towards external contexts, and potential opportunities and risks in the robotic market. The ARS purchase and procedural costs were evaluated in two different scenarios. RESULTS: In the first scenario, setting the purchase cost of the Avatera at around $1.3-1.5 million, a total $400 procedural cost reduction compared to the RAS performed with the da Vinci Xi can be calculated. In the second scenario, with a purchase cos of the ARS of $700.000-800.000 and considering a 5-year period with an annual ARS volume of 500 procedures, only an additional $300 will be attributed to the robot itself. Our projections revealed that for an effective competition the purchase cost of ARS should range between $700.000 and $800.000 during the initial phase of market entry. The marketing strategy of the ARS should be oriented towards countries without any robotic system in operational use, followed by countries where the competition intensity in the marketplace is low. CONCLUSION: The introduction of new robotic systems will greatly affect and reshape the market of robotic surgery. The ARS has all the technical capacity ensuring the performance of high-quality surgical procedures. A fast spread and implementation of the ARS could be expected should the purchase and maintenance costs be kept low.


Assuntos
Custos e Análise de Custo , Procedimentos Cirúrgicos Robóticos/economia , Procedimentos Cirúrgicos Robóticos/instrumentação , Humanos
14.
World J Urol ; 40(5): 1231-1238, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35246705

RESUMO

PURPOSE: To evaluate the clinical efficacy and safety of drug-coated balloon (DCB) ureteroplasty for the management of non-malignant ureteral strictures. MATERIAL AND METHODS: A prospective "off-label" monocentric single-arm pilot study investigating the safety and efficacy of drug-coated balloon (DCB) (Lutonix®; BD, USA) was performed. Twenty-five patients with benign ureteral strictures related to uretero-enteric anastomosis (n = 13); lithiasis (n = 5), post-surgical complications (iatrogenic n = 5), transplanted kidney (n = 1) and post-radiotherapy (n = 1) were included. Following lesion crossing, predilatation was performed using 4-7 mm high-pressure balloon catheter (5-6Fr) with a balloon pressure of 6-7 atm based on the manufacturer's recommendation. In the absence of rupture of the ureteral wall, the DCB was dilated for 4 min. across the lesion. The process was repeated if deemed necessary to a maximum of three stricture dilatations. We analysed both clinical and radiological primary patency (no signs of ipsilateral hydronephrosis or improvement of the existing residual dilatation at the follow-up examinations) and secondarily safety endpoints. RESULTS: Mean lesion length was 40 ± 28.5 mm. Mean time follow up was 36 months ± 10.46 months. Strictures were located at upper ureteric (12%), lower ureteric (32%), ureterovesical anastomosis (4%) and uretero-enteric anastomosis (52%) levels. The overall radiological success at 1-year follow-up was 88% (22/25 patients). In 56% patients (14/25 patients with primary patency) the nephrostomy catheter was removed 21 days following a single DCB procedure. In 32% (8/25 patients) an additional dilatation sessions were required for maintaining the ureteral patency. The overall failure rate at 1-year follow-up was 12% (3/25 patients). Only one case of febrile urinary tract infection in a female patient (acute pyelonephritis) was encountered after the first dilatation. CONCLUSIONS: Paclitaxel-coated balloon ureteroplasty proved to be safe and effective for the treatment of non-malignant ureteral strictures. Larger studies are warranted to validate these promising initial results.


Assuntos
Paclitaxel , Obstrução Ureteral , Constrição Patológica/etiologia , Feminino , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Obstrução Ureteral/etiologia , Obstrução Ureteral/cirurgia
15.
World J Urol ; 40(7): 1873-1878, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35445335

RESUMO

PURPOSE: To investigate the effect of prolonged laser activation on irrigation fluid temperature by varying the power settings flow rate (10-30 ml/min). MATERIALS AND METHODS: An experimental study using a 20 ml syringe, 12/14 ureteral access sheath, a dual-lumen catheter and a thermocouple was performed. The laser was fired with 12 W (0.3 J × 40 Hz), 40 W (1 J × 40 Hz), 60 W (1.5 J × 40 Hz) using Quanta Ho 150 W (Quanta System, Samarate, Italy). All trials were performed with fluid outflow rate of 10, 20 and 30 ml/min with the fixed fluid volume at 10 ml. RESULTS: Continuous laser activation for 10 min with the outflow rate of 10 ml/min using only 12 W resulted to continuous temperature rise to as high as 83 °C. Similar rise of temperatures were observed for 40 W and 60 W with 10 ml/min outflow rate with intermittent laser activation. With 20 and 30 ml/min outflow rates the maximum temperatures for all power settings were below the threshold (< 43 °C). However, the time to reach the same total emitted energy was 60% and 40% shorter 60 W and 40 W, respectively. CONCLUSION: Our study found that continuous laser activation with as less as 12 W using 10 ml/min outflow rate increased the irrigation fluid temperature above the threshold only after 1 min. In the current experimental setup, with the fluid outflow rate of 20 and 30 ml/min safe laser activation with 60 W and 40 W (temperature < 43 °C) can be achieved reaching the same total emitted energy as with 12 W in significantly shorter time period.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Ureter , Temperatura Alta , Humanos , Litotripsia a Laser/métodos , Temperatura
16.
World J Urol ; 40(8): 2083-2089, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35751669

RESUMO

OBJECTIVE: To evaluate whether reducing tract dilation diameter in PCNL (percutaneous nephrolithotomy) procedures results in minimizing of renal trauma of the percutaneous tract. METHODS: A percutaneous renal access tract was established bilaterally to 11 pigs. Two pigs were euthanized immediately after the experiment, while nine pigs were sacrificed 1 month later. The percutaneous accesses were dilated up to 30Fr, 22Fr or 12Fr. The animals underwent a contrast-enhanced computer tomography immediately after the procedure and 30 days later. DMSA-scintigraphy with SPECT-CT was also performed. The kidneys of all animals were harvested for histological evaluation. The volume of scar tissue and the percentage of renal volume replaced by scar tissue were calculated. RESULTS: Immediate post-procedural CT-scans revealed a significant difference in defect diameter among the three modalities. However, the scar volume calculated on CT-images and histopathology showed a significant difference only when 30Fr dilation was compared to 12Fr dilation. The percentage of scar volume was negligible in all cases, but there was still a statistical difference between 30 and 12Fr dilation. Dilation up to 22Fr revealed no statistical differences compared to the other two modalities. DMSA-scintigraphy showed no scar tissue in any case. CONCLUSION: Dilation up to 30Fr may cause a significantly larger scar tissue on renal parenchyma compared to 12Fr dilation as it was shown on CT-images and microscopic evaluation, but based on the DMSA/SPECT-CT this difference seems to be insignificant to the renal function. The scar tissue caused by 22Fr dilation seemed to have no significant difference from the other modalities.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Nefrostomia Percutânea , Animais , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Dilatação , Rim/diagnóstico por imagem , Rim/lesões , Rim/fisiologia , Cálculos Renais/complicações , Nefrolitotomia Percutânea/efeitos adversos , Nefrostomia Percutânea/métodos , Succímero , Suínos
17.
World J Urol ; 40(5): 1217-1222, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35150299

RESUMO

OBJECTIVE: To evaluate the effectiveness of ureteroscopic lithotripsy for the management of large proximal ureteral stones > 10 mm using 14/16 Fr ureteral access sheath (UAS). MATERIALS AND METHODS: Patients' data from prospective database undergoing ureteroscopic laser lithotripsy with a use of 14/16Fr UAS were collected. All patients were pre-stented prior to the procedure. The fragmentation was performed with a semi-rigid ureteroscope using holmium laser energy with a power setting of 35 W (frequency-35 Hz; energy-1 J). Follow-up was scheduled at 4 weeks and 3 months postoperatively. RESULTS: In total 78 patients, 43 males and 35 females, were included in the study. The mean age of the patients was 59.5 ± 13.3 with a mean maximal stone diameter of 13.4 ± 2.1. The mean operative time was 35.7 ± 9.7 and the mean hospital stay was 2 ± 0.7 days. The primary SFR at 4 weeks was 73 patients (93.6%), while all 78 patients (100%) were stone free at 3-month follow-up, 2 of the patients receiving additional treatment. In total, 8 (10.2%) patients experienced Grade II complications. Intraoperative ureteral lesions were observed in 41 (52.6%) cases. Out of them 31 patients (39.7%) developed Grade 1, 8 patients (10.3%) Grade 2 and only 3 patients (2.6%) Grade 3 lesions. CONCLUSION: The use of 14/16Fr ureteral access sheath on pre-stented patients was associated with successful outcomes. A high stone-free rate of 93.6% was achieved at 4-week follow-up. The procedure was not associated with increased rate of postoperative complications and intraoperative ureteral injury.


Assuntos
Litotripsia a Laser , Litotripsia , Ureter , Cálculos Ureterais , Feminino , Humanos , Litotripsia a Laser/métodos , Masculino , Resultado do Tratamento , Ureter/cirurgia , Cálculos Ureterais/cirurgia , Ureteroscopia/métodos
18.
World J Urol ; 40(7): 1853-1858, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35366109

RESUMO

PURPOSE: To investigate the effect of different combinations of laser power settings and irrigation conditions using the pulse modulation technology of Quanta™ on irrigation fluid temperature (IFT) during FURS (flexible ureteroscopy) on an in-vivo porcine model with artificial stones. MATERIALS AND METHODS: A female pig was used. Following the insertion of artificial stones (Begostone™, BEGO USA, Lincoln, RI), a K-type thermocouple was fixed to the created percutaneous access tract. Real-time recordings of IFT during FURS were performed without UAS (ureteral access sheath), with 10/12 UAS, 12/14 UAS and 14/16 UAS. Stone fragmentation was achieved using Quanta Litho Cyber Ho 150 W™ (Samarate, Italy). The IFT was recorded for 30 s, during laser activation, with power settings of 20, 40, 60, 75 and 100 W under both manual pump and gravity irrigation. RESULTS: The IFT rise above 54 °C was recorded above a power of 40 W when gravity irrigation was used. The use of UAS prolonged the time for IFT to reach high values, although high power settings increase IFT within seconds from the laser activation. Under pump irrigation, only the 100 W power setting without the use of UAS resulted in dangerous IFT after approximately 10 s. CONCLUSION: The high-power Ho:YAG laser can cause a damaging thermal effect to the kidney exceeding the threshold of 54 °C, under gravity irrigation. Lower power settings (up to 40 W) can be used with safety. According to our experiment, when using high power settings, the use of UAS and manual pump irrigation, is the safest combination regarding renal thermal damage.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Animais , Feminino , Humanos , Cálculos Renais/cirurgia , Lasers de Estado Sólido/uso terapêutico , Litotripsia a Laser/métodos , Suínos , Tecnologia , Temperatura , Ureteroscopia/métodos
19.
World J Urol ; 40(12): 3067-3074, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36251056

RESUMO

PURPOSE: To evaluate the effectiveness and safety of nonpapillary prone endoscopic combined intrarenal surgery (ECIRS) and provide practical tips and tricks for the successful accomplishment of the procedure respecting the anatomical particularities. MATERIAL AND METHODS: This study is an analysis of a prospectively collected database including all cases of ECIRS performed between January 2019 and December 2021 in a high-volume tertiary center. All patients underwent the procedure in prone-split leg position. A nonpapillary renal puncture was performed. The used access sheaths were 22Fr or 30Fr. Lithotripsy was performed anterogradely with a dual-energy lithotripter with incorporated suction and retrogradely with holmium Yttrium-Aluminum-Garnet laser. RESULTS: A total of 33 patients were included. The initial stone-free rate (SFR) was 84.8% and the final SFR was 90.9%. The median stone size was 35 mm and 60% of patients had staghorn calculi. The prevalence of renal abnormalities was 21.3%, including 3 cases of horseshoe kidney, 2 cases of malrotation and 2 cases with complete duplicated systems. The median operative time was 47 min. The median hospital stay was 3 days and median hemoglobin loss was 1.2 gr/dL. Overall, the complication rate was 9.1%, all being Grade II complications (n = 2 fever and n = 1 transient bleeding). CONCLUSIONS: Nonpapillary prone ECIRS is an effective and safe procedure. Standardization of the procedure is critical to achieve good outcomes. Patients who benefit the most are probably the ones where additional punctures can be avoided using this technique, namely patients with renal abnormalities, incrusted ureteral stents and staghorn stones.


Assuntos
Cálculos Renais , Litotripsia , Nefrostomia Percutânea , Cálculos Coraliformes , Humanos , Nefrostomia Percutânea/métodos , Ureteroscopia/métodos , Cálculos Renais/cirurgia , Estudos Retrospectivos , Litotripsia/métodos , Resultado do Tratamento
20.
World J Urol ; 40(3): 789-794, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34853917

RESUMO

PURPOSE: To present our preliminary results and describe a technical modification of mini-PCNL (12Fr) with the insertion of a ureteral access sheath (UAS) to facilitate the procedure. METHODS: A prospective study for the time period of January 2020 to January 2021 was conducted including patients with renal stones sized ≤ 25 mm in whom prone mini-PCNL (tract size 12Fr) together with the retrograde insertion of UAS was performed. All patients had been prestented at least 1 week prior to the planned surgery. A single-step tract dilation to 12Fr diameter was performed through a nonpapillary medial puncture. The lithotripsy was achieved using high-power holmium yttrium aluminum garnet laser (Ho:YAG) with the 60 W power setting (40 Hz and 1.5 J). The follow-up investigations were planned at 1-month after the surgery. RESULTS: In total, 32 patients with the median age and stone size of 56.5 (IQR = 53-62) years and 20.8 (IQR = 19.3-22.7) mm were included. The median operative and cumulative fluoroscopy time were 34.0 (IQR = 29.9-37.5) and 1.9 (1.8-2.1) min, respectively. The stone-free rate (SFR) at 1-month follow-up was 93.8% (30/32). Only one patient developed a fever and required prolonged antibiotic administration. None of the patients experienced clinically significant bleeding. CONCLUSION: Our preliminary results showed that the use of UASs during mini-PCNL procedures is feasible and provides directed evacuation of the stone fragments reaching 93.8% SFR at a 1-month follow-up. Future well-designed studies are necessary to prove our findings.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia , Nefrolitotomia Percutânea , Humanos , Cálculos Renais/cirurgia , Lasers de Estado Sólido/uso terapêutico , Masculino , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA