Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Sensors (Basel) ; 20(16)2020 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-32823924

RESUMO

In recent years, many city governments around the world have begun to use information and communication technology to increase the management efficiency of on-street parking. Among various experimental smart parking projects, deployment of wireless magnetic sensors and smart parking meters are quite common. However, using wireless magnetic sensors can only detect the occupancy of parking spaces without the knowledge of who are currently using these parking spaces; human labor is still needed to issue the parking bills. In contrast, smart parking meters based on image recognition can detect the occupancy of parking spaces along with the license plate numbers, but the cost of deploying smart parking meters is relatively high. In this research, we investigate the feasibility of building an on-street parking management system mainly based on low-cost Bluetooth beacons. Specifically, beacon transmitters are installed in the vehicles, and beacon receivers are deployed along the roadside parking spaces. By processing the received beacon signals using Kalman filter, our system can detect the occupancy of parking spaces as well as the identification of the vehicles. Although distance estimation using the received signal strength is not accurate, our experiments show that it suffices for correct detection of parking occupancy.

2.
Sensors (Basel) ; 18(5)2018 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-29883386

RESUMO

The ubiquity of Bluetooth-enabled smartphones and peripherals has brought tremendous convenience to our daily life. In recent years, Bluetooth beacons have also been gaining popularity in implementing a variety of innovative location-based services such as self-guided systems in exhibition centers. However, the broadcast-based beacon technology can only provide unidirectional communication. In case smartphone users would like to respond to the beacon messages, they have to rely on their own mobile Internet connections to send the information back to the backend system. Nevertheless, mobile Internet services may not be always available or too costly. In this work, we develop a real-time locating system based only on the Bluetooth low energy (BLE) technology to support interactive communications by combining the broadcast and mesh topology options to extend the applicability of beacon solutions. Specifically, we turn the smartphone into a beacon device and augment the beacon devices with the capability of forming a mesh network. The implementation result shows that our beacon devices can detect the presence of specific users at specific locations, and then the presence state can be sent to the application server via the relay of beacon devices. Moreover, the application server can send personalized location-based messages to the users, again via the relay of beacon devices. With the capability of relaying messages between the beacon devices, it would be convenient for developers to implement a variety of interactive applications such as tracking VIP customers at the airport, or tracking an elder with Alzheimer’s disease in the neighborhood.

3.
Hu Li Za Zhi ; 60(1): 38-47, 2013 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-23386524

RESUMO

BACKGROUND: A constellation of factors accounts for teaching efficacy in the fundamental nursing practicum. Teachers play a critical role in terms of designing and executing an appropriate teaching plan, choosing effective methods, and holding appropriate teaching attitudes. It is thus extremely important that clinical teachers master the core characteristics of basic nursing practice. PURPOSE: This study aimed to illuminate the core characteristics of basic nursing practice for students for reference by clinical practicum teachers. METHODS: Qualitative research was used to identify the fundamentals of nursing practice by clinical teacher. Five focus group meetings were convened during the practice period. The researchers presided over group discussions held during the normal weekly teaching schedule and lasting approximately 2-4 hours each. The content analysis was adopted to analyze the data. RESULTS: Three major themes were proposed, including (1) student status: "novices were stymied by problems and thus improved slowly"; (2) teacher awareness: "teachers need to be aware of student capabilities, mood, and discomfort"; and (3) teaching style: "a good choice of methods should support and encourage students. CONCLUSIONS / IMPLICATIONS FOR PRACTICE: To cultivate professional nursing knowledge and self-confidence for future professional commitment, clinical teachers must first understand the characteristics and motivations of learning of their students and then select the, skills, and attitudes appropriate to provide step-by-step guidance. Communication with staffs and the preparation of atmosphere prior to nursing practice are also essential for students. Results provide insights into the technical college environment with regard to basic-level clinical nursing practice.


Assuntos
Educação em Enfermagem , Ensino , Comunicação , Humanos , Motivação , Pesquisa Qualitativa
4.
J Pers Med ; 12(3)2022 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-35330451

RESUMO

Introduction: This study aimed to verify the predictors of the diagnostic accuracy of rapid on-site evaluation (ROSE) in endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) among patients with non-small cell lung cancer (NSCLC). Methods: We retrospectively reviewed consecutive patients with NSCLC who underwent EBUS-TBNA for staging or diagnosis at our hospital from June 2016 to June 2018. The patients were divided into two groups­those with a correct diagnosis and an incorrect diagnosis after ROSE. Kaplan−Meier plots and log-rank tests were used to estimate outcomes. Results: A total of 84 patients underwent EBUS-TBNA for staging and diagnosis. Sixty patients with demonstrated malignant mediastinal lymph nodes were enrolled. In the univariate analysis, lymph nodes < 1.5 cm (HR = 3.667, p = 0.031) and a SUVmax > 5 (HR = 41, p = 0.001) were statistically significant for diagnostic accuracy of ROSE. In the multivariate Cox regression analysis, only a SUVmax > 5 (HR = 20.258, p = 0.016) was statistically significant. Conclusions: A SUVmax > 5 is an independent predictor of higher diagnostic accuracy of ROSE in EBUS-TBNA in patients with NSCLC with malignant mediastinal lymph nodes. Therefore, ROSE in patients with a SUVmax < 5 might not be reliable and requires further prudent assessment (more shots or repeated biopsies at mediastinal LNs) in clinical practice.

5.
Aging (Albany NY) ; 12(24): 24853-24871, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33361519

RESUMO

Duchenne Muscular Dystrophy (DMD) patients often suffer from both muscle wasting and osteoporosis. Our previous studies have revealed reduced regeneration potential in skeletal muscle and bone, concomitant with ectopic calcification of soft tissues in double knockout (dKO, dystrophin-/-; utrophin-/-) mice, a severe murine model for DMD. We found significant involvement of RhoA/ROCK (Rho-Associated Protein Kinase) signaling in mediating ectopic calcification of muscles in dKO mice. However, the cellular identity of these RhoA+ cells, and the role that RhoA plays in the chronic inflammation-associated pathologies has not been elucidated. Here, we report that CD68+ macrophages are highly prevalent at the sites of ectopic calcification of dKO mice, and that these macrophages highly express RhoA. Macrophages from dKO mice feature a shift towards a more pro-inflammatory M1 polarization and an increased expression of various senescence-associated secretory phenotype (SASP) factors that was reduced with the RhoA/ROCK inhibitor Y-27632. Further, systemic inhibition of RhoA activity in dKO mice led to reduced number of RhoA+/CD68+ cells, as well as a reduction in fibrosis and ectopic calcification. Together, these data revealed that RhoA signaling may be a key regulator of imbalanced mineralization in the dystrophic musculoskeletal system and consequently a therapeutic target for the treatment of DMD or other related muscle dystrophies.


Assuntos
Calcinose/metabolismo , Macrófagos/metabolismo , Músculo Esquelético/metabolismo , Distrofia Muscular Animal/metabolismo , Miocárdio/metabolismo , Quinases Associadas a rho/metabolismo , Proteína rhoA de Ligação ao GTP/metabolismo , Animais , Antígenos CD/metabolismo , Antígenos de Diferenciação Mielomonocítica/metabolismo , Calcinose/imunologia , Calcinose/patologia , Senescência Celular/genética , Senescência Celular/imunologia , Modelos Animais de Doenças , Distrofina/genética , Macrófagos/imunologia , Camundongos , Camundongos Knockout , Músculo Esquelético/imunologia , Músculo Esquelético/patologia , Distrofia Muscular Animal/genética , Distrofia Muscular Animal/imunologia , Distrofia Muscular Animal/patologia , Distrofia Muscular de Duchenne/genética , Distrofia Muscular de Duchenne/imunologia , Distrofia Muscular de Duchenne/metabolismo , Distrofia Muscular de Duchenne/patologia , Miocárdio/imunologia , Miocárdio/patologia , Utrofina/genética , Quinases Associadas a rho/imunologia , Proteína rhoA de Ligação ao GTP/imunologia
6.
Artigo em Inglês | MEDLINE | ID: mdl-18001897

RESUMO

In this study, Kinesio Tape(R) is used in patients with lateral epicondylitis. The ultrasonic image sequences of elbow are recorded dynamically, and then motion tracking is applied to assist in understanding the effect of the therapy. Motion tracking, based on optical flow method, is used to track certain landmark on the ultrasound image, which is very ambiguous, for estimating the motion of muscle. Hierarchical block tracking technique is proposed to perform this task. The motions with and without Kinesio Taping are compared and can be used as quantitative indicators for the treatment. The experimental results show that Kinesio Taping makes the motion of muscle on the ultrasonic images enlarge. It means that the performance of muscle motion gets improve.


Assuntos
Cotovelo/diagnóstico por imagem , Cotovelo de Tenista/diagnóstico por imagem , Ultrassonografia/métodos , Algoritmos , Humanos , Atividade Motora/fisiologia , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiopatologia , Cotovelo de Tenista/fisiopatologia , Cotovelo de Tenista/terapia , Ultrassonografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA