Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Nanosci Nanotechnol ; 16(5): 4936-42, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27483849

RESUMO

Visualizing the biodistribution of pesticides inside living cells is great importance for enhancing targeting of pesticides. Here we reported for the first time that gold nanorods (Au NRs) with size of 39.4 nm x 11.3 nm could be used as a fluorescent tracer to examine the distribution of a typical herbicide, 2,4-dichlorophenoxyacetic acid (2,4-D), in tobacco bright yellow 2 (BY-2) cells. The nanostructures of hybrid materials were analyzed by using Raman spectra and X-ray photoelectron spectroscopy (XPS), including spectra assignments and electronic property. These data revealed 2,4-D has successfully conjugated MP-Au NRs according to Raman and XPS. The biodistribution of the conjugates inside BY-2 cells was directly examined at 12 and 24 h by the two-photon microscopy. The intensity of two-photon luminescence (TPL) inside cells demonstrated that the conjugates could be localized and excluded by BY-2 cells. Thus, this labeling approach opens up new avenues to the facile and efficient labeling of pesticides.


Assuntos
Ácido 2,4-Diclorofenoxiacético/farmacocinética , Ouro/química , Nanoconjugados/química , Nanotubos/química , Nicotiana/metabolismo , Células Cultivadas , Cristalização/métodos , Teste de Materiais , Microscopia de Fluorescência/métodos , Imagem Molecular/métodos , Nanoconjugados/ultraestrutura , Nanotubos/ultraestrutura , Tamanho da Partícula , Praguicidas/farmacocinética , Frações Subcelulares/química , Frações Subcelulares/metabolismo , Frações Subcelulares/ultraestrutura , Nicotiana/química
2.
J Data Sci ; 12(4): 279-294, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27335577

RESUMO

Fisher's exact test (FET) is a conditional method that is frequently used to analyze data in a 2 × 2 table for small samples. This test is conservative and attempts have been made to modify the test to make it less conservative. For example, Crans and Shuster (2008) proposed adding more points in the rejection region to make the test more powerful. We provide another way to modify the test to make it less conservative by using two independent binomial distributions as the reference distribution for the test statistic. We compare our new test with several methods and show that our test has advantages over existing methods in terms of control of the type 1 and type 2 errors. We reanalyze results from an oncology trial using our proposed method and our software which is freely available to the reader.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA