Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 60(4): A166-A172, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33690366

RESUMO

360-degree viewable three-dimensional (3D) display systems have gained considerable attention for the unique manner in which they display objects. Most of the optical display devices in these systems employ two parabolic mirrors facing each other separated by a distance equal to the focal length of the mirrors. However, the current configuration is limited to unity magnification and provides a small image relative to the volume of the system. This paper presents a novel 3D display system based on two Fresnel mirrors with different focal lengths facing each other. The distance between the mirrors can be adjusted to alter the magnification of the resulting 3D image. Wave-optics analysis of an optical dual-lens system equivalent to the proposed dual-mirror system was used to simulate the image distance, the transverse and longitudinal magnification, and the minimum length of the proposed system. This paper also addresses issues pertaining to the design and manufacture of Fresnel mirrors. An experiment system using Fresnel mirrors with focal lengths of 60mm and 90mm clearly demonstrated the efficacy of the proposed scheme in terms of 3D image magnification.

2.
J Microsc ; 266(2): 178-185, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28267883

RESUMO

A shearing interference microscope using a Savart prism as the shear plate is proposed for inspecting step-heights. Where the light beam propagates through the Savart prism and microscopic system to illuminate the sample, it then turns back to re-pass through the Savart prism and microscopic system to generate a shearing interference pattern on the camera. Two measurement modes, phase-shifting and phase-scanning, can be utilized to determine the depths of the step-heights on the sample. The first mode, which employs a narrowband source, is based on the five-step phase-shifting algorithm and has a measurement range of a quarter-wavelength. The second mode, which adopts a broadband source, is based on peak-intensity identification technology and has a measurement range up to a few micrometres. This paper is to introduce the configuration and measurement theory of this microscope, perform a setup used to implement it, and present the experimental results from the uses of the setup. The results not only verify the validity but also confirm the high measurement repeatability of the proposed microscope.

3.
Opt Lett ; 38(14): 2502-4, 2013 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-23939094

RESUMO

This work proposes an orthogonal polarization Mirau interferometry using a reflective-type waveplate to generate different polarization orientations for broadband white light interferometry. The reflective-type half-waveplate is employed as the reference arm of the Mirau interferometer to convert polarization and it generates a reference light with an orientation orthogonal to the object light. An advantage of the proposed interferometer is its ability to control the ratio of light intensity between the object and reference arms to maximize the interferometric fringe contrast. Better, more accurate calibration of standard step height has been achieved by the developed interferometer, which also can measure solder bumps that traditional Mirau interferometers usually cannot measure.

4.
Opt Lett ; 37(11): 1907-9, 2012 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-22660069

RESUMO

A shearing interferometer based on using broadband light source, Savart plate, and angular scanning technique is proposed for slope contour measurements in this Letter. Of which, the Savart plate divides the wavefront reflected from the detected surface into two laterally displaced ones, the interference pattern generated by the interference of the divided wavefronts is modulated by an envelope function, and the slope contour of the detected surface is determined by examining the shifting of the darkest fringe as the shear plate is angularly scanned. A setup for realizing the interferometer is constructed. The experimental results of using this setup agree the validity and feasibility of the proposed interferometer.

5.
Opt Lett ; 37(4): 467-9, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22344075

RESUMO

This Letter introduces a polarization phase-shifting Newton interferometer that can be utilized for plane optical surface measurements, a setup constructed to realize the interferometer, and the experimental results from the use of the setup. The results confirm not only the validity but also the feasibility of the interferometer.

6.
Opt Express ; 19(22): 21929-37, 2011 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-22109045

RESUMO

A calibrator utilizing a low-coherent light source straightness interferometer and a compensation method is introduced for straightness measurements in this paper. Where the interference pattern, which is modulated by an envelope function, generated by the interferometer undergoes a shifting as the Wolaston prism of the interferometer experiences a lateral displacement, and the compensation method senses the displacement by driving the prism back to the position to restore the pattern. A setup, which is with a measurement sensitivity of 36.6°/µm, constructed for realizing the calibrator is demonstrated. The experimental results from the uses of the setup reveal that the setup is with a measurement resolution and stability of 0.019 and 0.08 µm, respectively, validate the calibrator, and confirm the calibrator's applicability of straightness measurements and advantage of extensible working distance.

7.
Opt Express ; 18(3): 1794-800, 2010 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20174008

RESUMO

A novel angular probe using the Fabry-Perot etalon and angular scanning technique is proposed for absolute angular displacement determinations in this paper. The measurement theory is first derived, a setup constructed to implement the angular probe is then introduced and analyzed, and the experimental results from the uses of the setup are finally presented. The setup analyses reveal that the probe is with high measurement resolution and sensitivity. The experimental results not only confirm the validity, stability, accuracy, and repeatability, but also show an application of the angular probe.

8.
Opt Lett ; 34(21): 3406-8, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19881609

RESUMO

An optical measurement method to get the in-plane and out-of-plane displacements of a local surface using a laser is proposed. The proposed method simultaneously derives the in-plane and out-of-plane displacements by measuring the shift of interference fringes formed by scattered beams. The average errors of the in-plane and out-of-plane displacement measurements are significantly smaller than 10 nm. Moreover, the proposed method uses only low-cost optical elements.

9.
Appl Opt ; 48(36): 6940-5, 2009 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-20029596

RESUMO

Although barcodes can be used to manage data conveniently, they cannot be applied to small areas. Therefore, pointcodes are used to overcome the issue in this article. A pointcode uses a pointcode pattern to encode data and uses a pointcode image to decode data. A pointcode pattern is composed of many grating dots with different specified grating pitches and grating orientations. Moreover, there are two grating-dot sizes generated. When a laser beam illuminates a pointcode pattern with correct illuminating conditions, a pointcode image corresponding to the hidden data is diffractively reconstructed. A pointcode image is composed of many bright points with different positions. There are two possible bright-point sizes generated. A bright point or two bright points at specified positions are used to denote a number. Small pointcode patterns are enough to diffractively form pointcode images.

10.
Opt Lett ; 33(17): 1942-4, 2008 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-18758572

RESUMO

Bar arrangements used by conventional diffractive barcodes are usually similar to those used by diffusive barcodes. We, however, propose a modified diffractive barcode with bar arrangements different from those used by diffusive barcodes. A modified diffractive barcode pattern is composed of many parallel grating-dot lines. When the grating-dot lines are scanned by a laser beam in sequence, different bright bar arrangements corresponding to different codes appear in sequence.

11.
Opt Lett ; 33(20): 2344-6, 2008 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-18923617

RESUMO

An interferometer based on using low-coherent light source, a square prism, and the angular-scanning technique is proposed for absolute angular-displacement determinations. An angular displacement of the square prism shifts the correlogram, which is modulated by an envelope function, of the interference signal of the beams passing through the prism. This angle can thus be discovered by detecting the shifting of the envelope peak. A setup constructed to validate the interferometer is used. The results of using this setup are then presented.

12.
Opt Lett ; 33(11): 1183-5, 2008 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-18516167

RESUMO

We propose and demonstrate a method for the measurement of the wavefronts of high-power diode laser beams with large dynamic ranges. Our wavefront sensor consists of a movable pinhole and a wavefront-slope detector. The measurement results show that the wavefront sensor exhibits a large dynamic range of pi/2 to -pi/2 and a high precision on the measured average wavefront slope. The wavefronts of high-power diode laser beams having large divergence angles at arbitrary locations (including near and far fields) can be reconstructed via the wavefront measurement at a given location. The amplitude and phase distributions of a laser beam could be determined from the measured optical field data using diffraction theory. The experimental measurement of the wavefront of a 980 nm diode laser beam will be presented and discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA