Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Arch Orthop Trauma Surg ; 144(4): 1611-1619, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38285222

RESUMO

PURPOSE: Freehand distal interlocking of intramedullary nails remains a challenging task. Recently, a new training device for digitally enhanced hands-on surgical training (DEHST) was introduced, potentially improving surgical skills needed for distal interlocking. AIM: To evaluate whether training with DEHST enhances the performance of novices (first-year residents without surgical experience in freehand distal nail interlocking). METHODS: Twenty novices were randomly assigned to two groups and performed distal interlocking of a tibia nail in mock operation under operation-room-like conditions. Participants in Group 1 were trained with DEHST (five distal interlocking attempts, 1 h of training), while those in Group 2 did not receive training. Time, number of X-rays shots, hole roundness in the X-rays projection and hit rates were compared between the groups. RESULTS: Time to complete the task [414.7 s (range 290-615)] and X-rays exposure [17.8 µGcm2 (range 9.8-26.4)] were significantly lower in Group 1 compared to Group 2 [623.4 s (range 339-1215), p = 0.041 and 32.6 µGcm2 (range 16.1-55.3), p = 0.003]. Hole projections were significantly rounder in Group 1 [95.0% (range 91.1-98.0) vs. 80.8% (range 70.1-88.9), p < 0.001]. In Group 1, 90% of the participants achieved successful completion of the task in contrast to a 60% success rate in Group 2. This difference was not statistically significant (p = 0.121). CONCLUSIONS: In a mock-operational setting, training with DEHST significantly enhanced the performance of novices without surgical experience in distal interlocking of intramedullary nails and hence carries potential to improve safety and efficacy of this important and demanding surgical task to steepen the learning curve without endangering patients. LEVEL OF EVIDENCE: II.


Assuntos
Fixação Intramedular de Fraturas , Fraturas da Tíbia , Humanos , Pinos Ortopédicos , Radiografia , Tíbia , Fraturas da Tíbia/cirurgia
2.
Arch Orthop Trauma Surg ; 143(2): 887-893, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35137253

RESUMO

BACKGROUND: Multiple rib fractures are associated with significant morbidity and mortality, especially in elderly patients. There is growing interest in surgical stabilization in this subgroup of patients. This systematic review compares conservative treatment to surgical fixation in elderly patients (older than 60 years) with multiple rib fractures. The primary outcome is mortality. Secondary outcomes include hospital and intensive care length of stay (HLOS and ILOS), duration of mechanical ventilation (DMV) and pneumonia rates. METHODS: Multiple databases were searched for comparative studies reporting on conservative versus operative treatment for rib fractures in patients older than 60 years. Both observational studies and randomised clinical trials were considered. RESULTS: Five observational studies (n = 2583) were included. Mortality was lower in operatively treated patients compared to conservative treatment (4% vs. 8%). Pneumonia rate and DMV were similar (5/6% and 5.8/6.5 days) for either treatment modality. Overall ILOS and HLOS of stay were longer in operatively treated patients (6.5 ILOS and 12.7 HLOS vs. 2.7 ILOS and 6.5 ILOS). There were only minimal reports on perioperative complications. Notably, the median number of rib fractures (8.4 vs. 5) and the percentage of flail chest were higher in operatively treated patients (47% vs. 39%). CONCLUSION: It remains unknown to what extent conservative and operative treatment contribute individually to reducing morbidity and mortality in the elderly with multiple rib fractures. To date, the quality of evidence is rather low, thus well-performed comparative observational studies or randomised controlled trials considering all confounders are needed to determine whether operative treatment can improve a patient's outcome.


Assuntos
Tórax Fundido , Pneumonia , Fraturas das Costelas , Fraturas da Coluna Vertebral , Humanos , Idoso , Fraturas das Costelas/cirurgia , Fraturas das Costelas/complicações , Tórax Fundido/cirurgia , Tempo de Internação , Fixação de Fratura/efeitos adversos , Fraturas da Coluna Vertebral/complicações , Pneumonia/etiologia , Pneumonia/complicações , Estudos Retrospectivos
3.
Medicina (Kaunas) ; 59(11)2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-38004092

RESUMO

Background and Objectives: The surgical treatment of proximal humeral shaft fractures usually considers application of either long straight plates or intramedullary nails. By being able to spare the rotator cuff and avoid the radial nerve distally, the implementation of helical plates might overcome the downsides of common fixation methods. The aims of the current study were (1) to explore the biomechanical competence of different plate designs and (2) to compare their performance versus the alternative treatment option of using intramedullary nails. Materials and Methods: Twenty-four artificial humeri were assigned to the following four groups for simulation of an unstable proximal humeral shaft fracture and instrumentation: Group 1 (Straight-PHILOS), Group 2 (MULTILOC-Nail), Group 3 (45°-Helical-PHILOS), and Group 4 (90°-Helical-PHILOS). All specimens underwent non-destructive, quasi-static biomechanical testing under loading in axial compression, torsion in internal/external rotation, and pure bending in four directions, accompanied by motion tracking. Results: Axial stiffness/displacement in Group 2 was significantly higher/smaller than in all other groups (p ≤ 0.010). Torsional displacement in Group 2 was significantly bigger than in all other groups (p ≤ 0.017). Significantly smaller coronal plane displacement was identified in Group 2 versus all other groups (p < 0.001) and in Group 4 versus Group 1 (p = 0.022). Significantly bigger sagittal plane displacement was detected in Group 4 versus all other groups (p ≤ 0.024) and in Group 1 versus Group 2 (p < 0.001). Conclusions: Intramedullary nails demonstrated higher axial stiffness and smaller axial interfragmentary movements compared with all investigated plate designs. However, they were associated with bigger torsional movements at the fracture site. Although 90°-helical plates revealed bigger interfragmentary movements in the sagittal plane, they demonstrated improved resistance against displacements in the coronal plane when compared with straight lateral plates. In addition, 45°-helical plates manifested similar biomechanical competence to straight plates and may be considered a valid alternative to the latter from a biomechanical standpoint.


Assuntos
Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/métodos , Pinos Ortopédicos , Fenômenos Biomecânicos , Fixação Interna de Fraturas , Úmero , Placas Ósseas
4.
Eur J Orthop Surg Traumatol ; 33(6): 2337-2345, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36401000

RESUMO

PURPOSE: The primary aim was to describe the population characteristics of patients with combined scapula and rib fractures and outcomes associated with different treatment strategies. METHODS: All adult (≥ 18 years) patients with concurrent ipsilateral scapula and rib fractures admitted to the study hospital between 1st January 2010 and 31st June 2021 were retrospectively reviewed. RESULTS: A total of 223 patients were admitted with concurrent ipsilateral rib and scapula fractures. A total of 160 patients (72%) were treated conservatively, 63 patients (28%) operatively. Among operatively treated patients, 32 (51%) underwent rib fixation (RF) only, 24 (38%) underwent scapula fixation (SF) only, and seven patients (11%) underwent combined fixation of scapula and ribs (SRF). In general, more severely injured patients were treated with more extensive surgery. RF patients had a median hospital length of stay of 16 days, the SF patients 11 days and SRF patients 18 days. There were no significant differences in complications (pneumonia, recurrent pneumothorax and revision surgery) between groups. CONCLUSION: Injury severity resulted in different treatment modalities. As a result, different patient characteristics between treatment groups were observed, which makes direct comparison between treatment modalities impossible. All treatment modalities seem feasible; however, the additional value of both rib and scapula fixation has yet to be proven in large multicentre studies.


Assuntos
Tórax Fundido , Fraturas das Costelas , Traumatismos Torácicos , Adulto , Humanos , Fraturas das Costelas/complicações , Fraturas das Costelas/cirurgia , Estudos Retrospectivos , Tórax Fundido/etiologia , Tórax Fundido/cirurgia , Traumatismos Torácicos/complicações , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Tempo de Internação
5.
Medicina (Kaunas) ; 58(12)2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36557015

RESUMO

The ideal surgical treatment of femoral neck fractures remains controversial. When treating these fractures with internal fixation, many fixation constructs exist. The primary aim of this study was to evaluate the incidence and specific risk factors associated with complication and re-operation following fixation of intracapsular proximal femoral fractures using the Targon-FN system (B.Braun Melsungen AG). A secondary aim was to identify if lateral prominence of the implant relative to the lateral border of the vastus ridge was a specific risk factor for elective plate removal. Methodically, a retrospective case series was conducted of all consecutive adult patients treated at a single level 1 trauma center in Switzerland for an intracapsular proximal femoral fracture with the Targon-FN. Demographic data were collected. Patients with a follow-up of less than three months were excluded. Complications as well as plate position were recorded. Statistical analysis to identify specific risk factors for re-operation and complications was performed. In result, a total of 72 cases with intracapsular femoral neck fractures were treated with the Targon-FN locking plate system between 2010 and 2017. Thirty-four patients (47.2%) experienced one or more complications. The most common complication was mechanical irritation of the iliotibial band (ITB) (23.6%, n = 17). Complications included intraarticular screw perforation (6.9%, n = 5), avascular necrosis (5.6%, n = 4), non-union (5.6%, n = 4) among others. In total, 46 re-operations were required. Younger age, fracture displacement and time to postoperative weight bearing were identified as risk factors for re-operation. In conclusion, intracapsular femoral neck fractures treated with the Targon-FN system resulted in a high rate of post-operative complication and re-operation. Statistical analysis revealed patient age, fracture displacement, time to postoperative full weight bearing were risk factors for re-operation. The main limitation is the limited number of cases and a short follow-up of less than 12 months in a subgroup of our patients.


Assuntos
Fraturas do Colo Femoral , Fraturas Proximais do Fêmur , Adulto , Humanos , Estudos Retrospectivos , Fraturas do Colo Femoral/cirurgia , Parafusos Ósseos/efeitos adversos , Reoperação , Fixação Interna de Fraturas/efeitos adversos , Placas Ósseas/efeitos adversos
6.
Medicina (Kaunas) ; 57(6)2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34200303

RESUMO

Background and objective: Falls in elderly cause injury, mortality, and loss of independence, making Fear of Falling (FoF) a common health problem. FoF relates to activity restriction and increased fall risk. A voluntary intervention including fall risk assessment and prevention strategies was implemented to reduce falls in elderly patients with low energy fractures (LEF). The primary purpose of this study was to evaluate FoF and the number of subsequent falls in trauma patients one year after a LEF. The secondary aim was to examine how FoF affects patients' lives in terms of Quality of Life (QoL), mobility, and activity levels. Finally, participation in the voluntary fall prevention program (FPP) was evaluated. Materials and Methods: Observational cohort study in one Swiss trauma center. LEF patients, treated between 2012 and 2015, were analyzed one year after injury. Primary outcomes were Falls-Efficacy Score-International (FES-I) and number of subsequent falls. Secondary outcomes were EuroQoL-5-Dimensions-3-Levels (EQ5D-3L), mobility, activity levels, and participation in the FPP. Subgroup analysis was performed for different age categories. Results: 411 patients were included for analysis. Mean age was 72 ± 9.3, mean FES-I was 21.1 ± 7.7. Forty percent experienced FoF. A significant negative correlation between FoF and QoL (R = 0.64; p < 0.001) was found. High FoF correlated with lower activity levels (R= -0.288; p < 0.001). Six percent visited the FPP. Conclusions: At follow-up, 40% suffered from FoF which seems to negatively affect patients' QoL. Nevertheless, participation in the FPP was low. Simply informing patients about their susceptibility to falls and recommending participation in FPPs seems insufficient to motivate and recruit patients into FPPs. We suggest implementing repeated fall risk- and FoF screenings as standard procedures in the follow-up of LEF, especially in patients aged over 75 years.


Assuntos
Fraturas Ósseas , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Medo , Humanos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia
7.
Medicina (Kaunas) ; 57(9)2021 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-34577807

RESUMO

Background and Objectives: Wound infections provoked by alterations in microcirculation are major complications in the treatment of trochanteric femur fractures. Surgical fracture fixation on a traction table is the gold standard for treatment, but the effect on tissue microcirculation is unknown. Microcirculation could be impaired by the pull on the soft-tissue or by a release of vasoactive factors. We hypothesized that intraoperative traction impairs soft-tissue microcirculation. Materials and Methods: In 22 patients (14 women, eight men), average age 78 years (range 36-96 ± 14), with trochanteric femur fractures, non-invasive laser-Doppler spectrophotometry was used to assess oxygen saturation, hemoglobin content, and blood flow in the skin and subcutaneous tissue before and after application of traction. Measurements were recorded in nine locations around the greater trochanter at a depth of 2, 8, and 15 mm before and after fracture reduction by traction. Results: No differences were found in any depth with traction compared to without (oxygen saturation: p = 0.751, p = 0.308, and p = 0.955, haemoglobin content: p = 0.651, p = 0.928, and p = 0.926, blood flow: p = 0.829, p = 0.866, and p = 0.411). Conclusion: In this pilot study, the application of traction does not affect skin and subcutaneous microcirculation in the surgery of proximal femur fractures.


Assuntos
Fraturas do Fêmur , Tração , Adulto , Feminino , Fraturas do Fêmur/cirurgia , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Masculino , Microcirculação , Pessoa de Meia-Idade , Projetos Piloto , Adulto Jovem
8.
BMC Endocr Disord ; 20(1): 80, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32503586

RESUMO

BACKGROUND: Acute compartment syndrome is a rare complication of severe hypothyroidism. If the symptoms are not recognized promptly and treatment initiated immediately, there is a high risk of permanent damage. Only few other cases of compartment syndrome due to hypothyroidism have been published and the exact pathophysiological mechanism remains unknown. CASE PRESENTATIONS: A 59 year old male developed acute compartment syndrome of his right lower leg after thyroid hormone withdrawal prior to radioiodine remnant ablation after total thyroidectomy for follicular thyroid cancer. He underwent emergency fasciotomy of all four compartments of the lower leg. The muscle tissue in the anterior and lateral compartment was necrotic and was therefore excised. The second patient was a 62 year old female with Hashimoto's thyroiditis, who developed acute compartment syndrome of both lower legs after thyroid hormone withdrawal due to non-compliance. Emergency fasciotomy of all four compartments of both legs was performed. The muscle tissue was viable in all compartments. CONCLUSION: Although compartment syndrome due to hypothyroidism is uncommon, it is a complication physicians should be aware of. The majority of reported cases are caused by an acute withdrawal of thyroid hormones and not by undetected hypothyroidism. No previous case of compartment syndrome caused by an iatrogenic hormone withdrawal in preparation for radioactive iodine has been published. However, as shown in this report, it may be beneficial to inform patients of this rare complication prior to hormone withdrawal in preparation for remnant ablation after thyroidectomy.


Assuntos
Síndromes Compartimentais/cirurgia , Desprescrições , Fasciotomia , Doença de Hashimoto/tratamento farmacológico , Hipotireoidismo/tratamento farmacológico , Adesão à Medicação , Tiroxina/uso terapêutico , Adenocarcinoma Folicular/radioterapia , Síndrome do Compartimento Anterior/etiologia , Síndrome do Compartimento Anterior/cirurgia , Síndromes Compartimentais/etiologia , Feminino , Doença de Hashimoto/complicações , Terapia de Reposição Hormonal , Humanos , Hipotireoidismo/complicações , Radioisótopos do Iodo/uso terapêutico , Perna (Membro) , Masculino , Pessoa de Meia-Idade , Neoplasias da Glândula Tireoide/radioterapia , Tireoidectomia
9.
J Shoulder Elbow Surg ; 28(6): 1033-1039, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30713061

RESUMO

BACKGROUND: This study evaluated the feasibility and reliability of high-resolution ultrasonography (HRUS) of the radial nerve in the early, postoperative period after operative stabilization of humeral shaft fractures. METHODS: This study enrolled patients between September 2015 and April 2018 with a humeral shaft fracture who were assessed with HRUS within 2 weeks after surgery. Based on the ultrasound artifacts, the examiners subjectively defined quality of ultrasound as "bad" or "good." The cross-sectional area of the radial and the posterior interosseous nerve was recorded at predefined locations. The radial nerve was scanned axially in the whole course to identify nerve continuity. RESULTS: Of 44 patients who underwent operations for humeral shaft fracture, HRUS was used to assess 15 patients at an average 4.8 ± 2.6 days (range, 2-11 days) after surgery. The examiners defined ultrasound quality as "good" in 13 of 15 patients (~87%). Primary radial nerve palsy (RNP) was identified in 3 of the 15 patients, and 4 sustained secondary RNP. Nerve continuity was demonstrated by HRUS in every patient. In patients with RNP, nerve continuity was secondarily confirmed by surgical exploration or functional and electrophysiological recovery. CONCLUSION: Early postoperative HRUS of the radial nerve after osteosynthesis of humeral shaft fractures is a feasible and reliable method to identify radial nerve continuity. In case of pathology, this assessment tool can additionally provide valuable information concerning location and etiology of the RNP.


Assuntos
Fraturas do Úmero/cirurgia , Nervo Radial/diagnóstico por imagem , Neuropatia Radial/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Fraturas do Úmero/reabilitação , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Reprodutibilidade dos Testes , Ultrassonografia , Adulto Jovem
10.
Arch Orthop Trauma Surg ; 138(3): 339-349, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29256184

RESUMO

INTRODUCTION: Due to the world's aging population, intertrochanteric fractures are frequent. Considering age and comorbidities of most of these patients, it is indispensable to enable early postoperative mobilization of these patients. Intramedullary osteosynthesis with PFN-A is widely used and, in general, considered safe and reliable for the operative treatment of intertrochanteric fractures. However, implant -related complications are reported in 6-21% of all cases. In this study, we are analyzing complication rates and risk factors for implant-related complications. MATERIALS AND METHODS: All intertrochanteric fractures admitted to our hospital and treated with PFN-A between January 2012 and January 2016 were analysed retrospectively. Radiological analyses of the CCD and the lateral offset on the uninjured side was compared to the CCD initially postoperatively and during follow-up on the operated side. Furthermore, we analysed the tip-apex distance (TAD), blade position in the femoral head and introduced the nail-shaft axis as a new parameter. RESULTS: Within 101 intertrochanteric fractures included, 16 implant-related complications were encountered (15.84%). Analyses of risk factors for secondary varus displacement of greater than 10° within the follow-up and thus risk for cut-out in the osteosynthesis revealed that etasblished risk factors such as a TAD > 25 mm, reduction in varus and an improper position of the blade were also significant risk factors in our cohort for failure of the osteosynthesis. Moreover, we introduced the nail-shaft axis a new potential risk factor and could show that a too medial or too lateral nail-shaft axis is also significantly associated with secondary varus displacement. CONCLUSION: When treating introchanteric fractures with PFNA reduction in neutral or even slight valgus, aiming for a TAD < 25 mm and a correct position of the blade within the femoral head reduced the risk for secondary varus displacement significantly. Furthermore, we suggest to aim for a central nail-shaft axis.


Assuntos
Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/métodos , Fraturas do Quadril/cirurgia , Complicações Pós-Operatórias , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Fatores de Risco
11.
Eur J Orthop Surg Traumatol ; 28(4): 565-572, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29417348

RESUMO

INTRODUCTION: Despite the frequent use of external fixation, various regimes of antibiotic prophylaxis, surgical technique and postoperative pin care exist and underline the lack of current evidence. The aim of the study was to assess the variability or consensus in perioperative protocols to prevent implant-associated infections for temporary external fixation in closed fractures of the extremities. MATERIALS AND METHODS: A 26-question survey was sent to 170 members of the Traumaplatform. The survey included questions concerning demographics, level of training, type of training and perioperative protocols as: antibiotic prophylaxis, intraoperative management, disinfection and postoperative pin site care. All responses were statistically analysed, and intraoperative measures rated on a 5-point Likert scale. RESULTS: The responses of fifty orthopaedic trauma and general surgeons (response rate, 29.4%) were analysed. The level of experience was more than 5 years in 92% (n = 46) with up to 50 closed fractures of the extremities annually treated with external fixation in 80% (n = 40). Highest consensus could be identified in the following perioperative measures: preoperative antibiotic prophylaxis with a second-generation cephalosporin (86%, n = 43), changing gloves if manipulation of the external fixator is necessary during surgery (86%, n = 43; 4.12 points on the Likert scale), avoid overlapping of the pin sites with the definitive implant site (94%, n = 47; 4.12 points on the Likert scale) and soft tissue protection with a drill sleeve (83.6%, n = 41). CONCLUSION: Our survey could identify some general principles, which were rated as important by a majority of the respondents. Futures studies' focus should elucidate the role of perioperative antibiotics and different disinfection protocols on implant-associated infections after temporary external fixation in staged protocols. LEVEL OF EVIDENCE: This study provides Level IV evidence according to Oxford centre for evidence-based medicine.


Assuntos
Antibioticoprofilaxia/estatística & dados numéricos , Fixadores Externos , Fixação de Fratura/métodos , Cuidados Intraoperatórios/métodos , Cirurgiões Ortopédicos/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Infecções Relacionadas à Prótese/prevenção & controle , Pinos Ortopédicos/efeitos adversos , Competência Clínica , Tomada de Decisão Clínica , Consenso , Desinfecção/estatística & dados numéricos , Fixação de Fratura/instrumentação , Saúde Global/estatística & dados numéricos , Luvas Cirúrgicas , Humanos , Cirurgiões Ortopédicos/normas , Cuidados Pós-Operatórios , Inquéritos e Questionários
12.
Eur J Orthop Surg Traumatol ; 27(8): 1117-1124, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28547675

RESUMO

PURPOSE: To assess the outcome in patients treated with proximal femoral locking compression plate (PF-LCP 4.5/5.0, Synthes©) for unstable inter- and subtrochanteric femoral fractures. METHODS: A retrospective analysis of 16 patients with proximal femur fractures (AO: 31A2: n = 5/32.3%; 31-A3: n = 10/62.5%; 32B1: n = 1/6.3%) treated with a PF-LCP at a Level 1 trauma centre between 2011 and 2015 was conducted. RESULTS: Sixteen patients were available for follow-up with a mean follow-up time of 14 months (range 4-29). Primary outcome included fracture healing, post-operative complications and post-operative ambulatory status. Male to female ratio was 1:1. Mean age was 61 ± 17 years. Union was achieved in a mean of 13.5 ± 3 weeks (range 12-20 weeks). Five patients (31.3%) had implant-associated complications like non-union, malrotation, late implant-associated infection, distal screw fractures and post-traumatic impingement of the hip. Consequently, four patients (25%) had to undergo revision surgery. There was no reported case of secondary varus collapse or cut-out. CONCLUSIONS: Complications occurred in 31.3% (n = 5) in medium-term follow-up after PF-LCP in proximal unstable inter- and subtrochanteric femur fractures. These findings are supported by results of other groups. However, further studies to evaluate risk factors associated with failure of this implant are required.


Assuntos
Fixação Interna de Fraturas/efeitos adversos , Fraturas do Quadril/cirurgia , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Placas Ósseas/efeitos adversos , Parafusos Ósseos/efeitos adversos , Feminino , Seguimentos , Fixação Interna de Fraturas/instrumentação , Consolidação da Fratura , Fraturas do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
13.
J Hand Surg Am ; 40(1): 27-33, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25457447

RESUMO

PURPOSE: To evaluate whether the dorsal tangential view (DTV) allows for reliable and valid in vivo measurement of the distance between screw tips and the dorsal radial cortex (STCD) during volar plating of distal radius fractures. METHODS: Subjects included 22 patients with displaced distal radius fractures who had volar plate osteosynthesis. We performed standardized DTV images intraoperatively. After surgery, we performed computed tomography (CT) scans with reconstructions parallel to the distal screws. Three independent observers blinded to the study protocol measured the STCD on the basis of the DTV images and CT reconstructions. We calculated inter- and intraobserver reliability and the correlation between STCD values measured with DTV images and CT scans. RESULTS: Eleven screws were changed intraoperatively. We observed no cases of postoperative screw perforations. Inter- and intraobserver reliability of STCD measurement was good when measured with DTV images and excellent when measured on the basis of CT reconstructions. Statistical analysis showed a good correlation between mean STCD values measured with DTV and CT. CONCLUSIONS: The DTV allowed in vivo evaluation of the dorsal radial cortex and enabled reliable assessment of the distance between the screw tip and the dorsal cortex. It may allow detection of dorsal screw perforation during volar plating of distal radial fractures.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/cirurgia , Adulto , Idoso , Placas Ósseas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
14.
J Orthop Res ; 42(4): 886-893, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37975265

RESUMO

Dual plating of comminuted distal femoral fractures allows for early patient mobilization. An additional helically shaped medial plate avoids the medial vital structures of the thigh. The aim of this study is to investigate the biomechanical competence of an augmented lateral locking compression plate distal femur (LCP-DF) using an additional straight versus a helically shaped medial LCP of the same length. Ten pairs of human cadaveric femora were instrumented with a lateral anatomical 15-hole LCP-DF. Following, they were pairwise instrumented with either an additional medial straight 14-hole LCP (group 1) or a 90°-helical shape LCP (group 2). All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading until failure. Initial interfragmentary axial displacement and flexion under static compression were significantly smaller in group 1 (0.11 ± 0.12 mm and 0.21 ± 0.10°) versus group 2 (0.31 ± 0.14 mm and 0.68 ± 0.16°), p ≤ 0.007. Initial varus deformation under static compression remained not significantly different between group 1 (0.57 ± 0.23°) and group 2 (0.75 ± 0.34°), p = 0.085. Flexion movements during dynamic loading were significantly bigger in group 2 (2.51 ± 0.54°) versus group 1 (1.63 ± 1.28°), p = 0.015; however, no significant differences were observed in terms of varus, internal rotation, and axial and shear displacements between the groups, p ≥ 0.204. Cycles to failure and load at failure were higher in group 2 (25,172 ± 6376 and 3017 ± 638 N) compared to group 1 (22,277 ± 4576 and 2728 ± 458 N) with no significant differences between them, p = 0.195. From a biomechanical perspective, helical double plating may be considered a useful alternative to straight double plating, demonstrating ameliorated damping capacities during flexion deformation and safer application as the medial neurovascular structures of the thigh are avoided.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Humanos , Fenômenos Biomecânicos , Fêmur/cirurgia , Placas Ósseas , Extremidade Inferior
15.
Artigo em Inglês | MEDLINE | ID: mdl-38907860

RESUMO

PURPOSE: Recently, a new dynamic high-strength suture (DC) was introduced, also available in tape form (DT), featuring a salt-infused silicone core attracting water in a fluid environment to preserve tissue approximation. The aims of this study were to (1) assess the influence of securing throw number on knot security of two double-stranded knot configurations (Cow-hitch and Nice-knot) tied with either dynamic (DC and DT) or conventional (FW and ST) high-strength sutures and tapes, and (2) compare the ultimate force and knot slippage of the novel dynamic versus conventional sutures and tapes when used with their minimal number of needed securing throws. METHODS: Seven specimens of each FW, ST, DC and DT were considered for tying with Cow-hitch or Nice-knots. The base of these Cow-hitch and Nice-knots was secured with surgeons` knots using 1-3 alternating throws. Tensile tests were conducted under physiologic conditions to evaluate knot slippage, ultimate force at rupture, and minimum number of throws ensuring 100% knot security.  RESULTS:  For both Cow-hitch and Nice-knots, 100% security was achieved with 2 securing throws for DC, DT, ST, and with 3 securing throws for FW. With these minimum numbers of securing throws, ultimate force was significantly higher for Nice-knots versus Cow-hitch tied with DT (p = 0.001) and slippage was significantly less with Nice-knots versus Cow-hitch tied with DC (p = 0.019). CONCLUSIONS: The minimum number of securing throws required to achieve 100% security was 2 with DC, DT and ST for both Cow-hitch and Nice-knots configurations, in contrast to FW where 3 securing throws were needed. With these minimum numbers of securing throws, Nice-knots were associated with significantly higher ultimate forces when using DT and lower slippage with DC versus Cow-hitch knots.

16.
J Clin Med ; 13(11)2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38893055

RESUMO

Background: The treatment of complex proximal humerus fractures in elderly patients is not yet fully elucidated. Of all treatment options, reverse shoulder arthroplasty (RSA) and non-operative treatment (NOT) appear to provide the best results. Evidence to guide the choice between the two is sparse. Therefore, this review provides an overview of the available evidence on RSA versus NOT. Methods: Studies comparing complex proximal humerus fractures in patients aged >65 years treated either with RSA or NOT were included for systematic review and direct comparison via pooled analysis of patient-rated outcome and range of motion. Indirect comparison of case series and non-comparative studies on either treatment was performed separately. Results: Three comparative studies including 77 patients treated with RSA and 81 treated non-operatively were analysed. The RSA group scored better for both the Constant-Murley score (mean difference 6 points) and DASH score (mean difference 8 points). No differences were detected in ASES, PENN score, pain scores, or range of motion between treatment groups. The most common complications for RSA were infection (3%), nerve injury (2%), and dislocation (2%). Reoperation was required in 5%. In the NOT group, common complications included malunion (42%), osteonecrosis (25%), and non-union (3%); no reoperation was required. Patient satisfaction was equal in both groups. Conclusions: The functional outcomes and range of motion after RSA seemed satisfactory and potentially superior to NOT in elderly patients. Patient satisfaction was comparable despite a high malunion and osteonecrosis rate in the non-operative treatment group, which did not require re-interventions.

17.
JMIR Res Protoc ; 13: e52917, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38349719

RESUMO

BACKGROUND: Distal radius fractures are the most frequently encountered fractures in Western societies, typically affecting patients aged 50 years and older. Although this is a common injury, the best treatment for these fractures in older patients is still under debate. OBJECTIVE: This prospective study aims to compare the outcome of operatively and nonoperatively treated distal radius fractures in the older population. Only patients with distal radius fractures for which equipoise regarding the optimal treatment exists will be included. METHODS: This prospective international multicenter observational cohort study will be designed as a natural experiment. Natural experiments are observational studies in which treatment allocation is determined by factors outside the control of the investigators but also (largely) independent of patient characteristics. Patients aged 65 years and older with an acute distal radius fracture will be considered for inclusion. Treatment allocation (operative vs nonoperative) will be based on the local preferences of the treating hospital either in Switzerland or the Netherlands. Hence, the process governing treatment allocation resembles that of randomization. Patients will be identified after treatment has been initiated. Based on the radiographs and baseline information of the patient, an expert panel of 6 certified trauma surgeons from 2 regions will provide their treatment recommendation. Only patients for whom the experts disagree on treatment recommendations will ultimately be included in the study (ie, for whom there is a clinical equipoise). For these patients, both operative and nonoperative treatment of distal radius fractures are viable, and treatment choice is predominantly determined by personal or local preference. The primary outcome will be the Patient-Rated Wrist Evaluation score at 12 weeks. Secondary outcomes will include the Physical Activity Score for the Elderly, the EQ questionnaire, pain, the living situation, range of motion, complications, and radiological outcomes. By including outcomes such as living situation and the Physical Activity Score for the Elderly, which are not relevant for younger cohorts, valuable information to tailor treatment to the needs of the older population can be gained. According to the sample size collection, which was based on the minimal important clinical difference of the Patient-Rated Wrist Evaluation, 92 patients will have to be included, with at least 46 patients in each treatment group. RESULTS: Enrollment began in July 2023 and is expected to continue until summer 2024. The final follow-up will be 2 years after the last patient is included. CONCLUSIONS: Although many trials on this topic have previously been published, there remains an ongoing debate regarding the optimal treatment for distal radius fractures in older patients. This observational study, which will use a fairly new methodological study design, will provide further information on treatment outcomes for older patients with distal radius fractures for which to date equipoise exists regarding the optimal treatment. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/52917.

18.
Unfallchirurgie (Heidelb) ; 126(2): 168-172, 2023 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-35420293

RESUMO

We describe the case of a forest worker with a Gustilo-Anderson III dislocation fracture of the ankle joint. After initial external fixation, round necrotic skin lesions with hyperemic border walls appeared on the entire lower leg. Recurrent débridements worsened the soft tissue instead of improving it. An immunoglobulin and corticosteroid treatment was initiated, which diminished the inflammatory reaction and granulation of soft tissue began. Posttraumatic pyoderma gangrenosum is a rare diagnosis. Nevertheless, it needs to be on the list of differential diagnoses if uncommon soft tissue reactions appear.


Assuntos
Fraturas Expostas , Pioderma Gangrenoso , Humanos , Pioderma Gangrenoso/diagnóstico , Fraturas Expostas/complicações , Perna (Membro) , Acidentes , Florestas
19.
J Bone Joint Surg Am ; 105(3): 207-213, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36622896

RESUMO

BACKGROUND: The aim of this single-center randomized controlled trial was to compare primary wound closure using a suture with secondary wound healing of pin sites after removal of temporary external fixation. METHODS: This noninferiority trial included all patients who were treated with a temporary external fixator on an upper or lower extremity at 1 institution. The primary outcome was pin-site infection. Secondary outcomes were measured at 2, 6, 12, 24, and 52 weeks and included all other complications, time to pin-site wound healing (in weeks), the most satisfactory pin site as rated by the patient, the visual analog scale (VAS) score for pain, and the Vancouver Scar Scale (VSS). The most proximal pin site was randomly allocated (1:1) to either primary closure or secondary wound healing, and the other pin sites were treated alternately. RESULTS: Seventy patients, providing 241 pin sites, were included between January 1, 2019, and March 1, 2020. A total of 123 pin sites were treated with primary closure and 118, with secondary wound healing. The median age was 55 years (interquartile range, 46 to 67 years), 44% were male, and the median duration of the external fixation was 6 days (interquartile range, 4 to 8 days). There were no pin-site infections in either group. Wound healing was significantly faster in the primary closure group (median of 2 versus 6 weeks, p = 0.013). The VSS and patient satisfaction showed no differences between groups. There was 1 case of fracture-related infection not related to any pin site. CONCLUSIONS: Primary closure of temporary external fixator pin sites did not result in higher infection rates compared with secondary wound healing, and pin sites healed significantly faster after primary closure. Primary closure should therefore be considered in patients treated with a temporary external fixator. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fixadores Externos , Fraturas Ósseas , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Resultado do Tratamento , Cicatrização , Fraturas Ósseas/etiologia , Fixação de Fratura/efeitos adversos , Cicatriz/etiologia
20.
Oper Orthop Traumatol ; 35(6): 352-369, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37395767

RESUMO

OBJECTIVE: The aim of surgical treatment is fracture healing with restored alignment, rotation, and joint surface. Stable fixation allows for functional postoperative aftercare. INDICATIONS: Displaced intra- and extra-articular fractures which either could not be adequately reduced or in which a secondary displacement is to expected due to instability criteria. The following factors are considered instability criteria: age > 60 years, female, initial dorsal displacement > 20°, dorsal comminution, radial shortening > 5 mm, palmar displacement. CONTRAINDICATIONS: The only absolute contraindication is if the patient is deemed unfit for surgery due to concerns regarding anesthesia. Old age is a relative contraindication, as it is currently debated whether older patients benefit from the operation. SURGICAL TECHNIQUE: The surgical technique is guided by the fracture pattern. Palmar plating is most commonly performed. If the joint surface needs to be visualized, a dorsal approach (in combination with another approach or alone) or arthroscopically assisted fixation should be chosen. POSTOPERATIVE MANAGEMENT: In general, a functional postoperative regime can be carried out after plate fixation with mobilization without weightbearing. Short-term splinting can provide pain relief. Concomitant ligamentous injuries and fixations, which are not stable enough for functional aftercare (such as k­wires) require a longer period of immobilization. RESULTS: Provided the fracture is reduced correctly, osteosynthesis improves functional outcome. The complication rate ranges between 9 and 15% with the most common complication being tendon irritation/rupture and plate removal. Whether surgical treatment holds the same benefits for patients > 65 years as for younger patients is currently under debate.


Assuntos
Fraturas do Rádio , Traumatismos dos Tendões , Fraturas do Punho , Traumatismos do Punho , Humanos , Feminino , Pessoa de Meia-Idade , Fraturas do Rádio/diagnóstico , Fraturas do Rádio/cirurgia , Resultado do Tratamento , Fios Ortopédicos/efeitos adversos , Traumatismos do Punho/complicações , Traumatismos do Punho/cirurgia , Fixação Interna de Fraturas/métodos , Placas Ósseas/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA