Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
Support Care Cancer ; 32(5): 327, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702458

RESUMO

PURPOSE: This study is to conduct a comprehensive scoping review to map scientific evidence and clarify concepts regarding the commonly recommended preventive and restorative dental treatments for patients diagnosed with head and neck cancer (HNC) and subjected to radiotherapy. MATERIAL AND METHODS: This systematic scoping review was performed under the PRISMA-ScR guidelines. The study's experimental design was registered in the Open Science Framework. In vitro studies that evaluated preventive and restorative dental treatment over 50 Gy radiation doses were included. The search was conducted in November 2023 in five electronic databases (PubMed, Scopus, Web of Science, Cochrane Library, and Embase) without language or date restriction. A search strategy was applied based on keywords, MeSh terms, or synonyms. A descriptive analysis was conducted. RESULTS: A total of 49 studies, out of 3679 original articles identified, were included and reviewed. Of the included studies, three evaluated saliva stimulants and 35 evaluated fluoride-based preventive materials: gel (n = 18) toothpaste (n = 11) mouth rinse (n = 8) and varnish (n = 5) while 14 evaluated restorative materials: resin composite (n = 12) glass ionomer cement (n = 6) and amalgam (n = 1) Of those studies, 36 were clinical trials and 13 were in vitro studies. CONCLUSION: Fluoride gel was the most frequently recommended preventive material for preventing radiation caries with supportive clinical evidence. Resin composite and glass ionomer were the most frequently used restorative materials, respectively. However, there is not yet clinical evidence to support the use of resin composite in irradiated teeth.


Assuntos
Cárie Dentária , Neoplasias de Cabeça e Pescoço , Humanos , Cárie Dentária/prevenção & controle , Neoplasias de Cabeça e Pescoço/radioterapia , Restauração Dentária Permanente/métodos
2.
J Esthet Restor Dent ; 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39295305

RESUMO

OBJECTIVE: This study evaluated the color change, surface roughness, mineral content and morphology of enamel bleached with 35% hydrogen peroxide (HP) combined with an experimental gel containing 1% titanium tetrafluoride (TiF4). MATERIALS AND METHODS: Bovine enamel blocks were treated with (n = 12): (TiF) experimental gel containing 1% TiF4, (HP) 35% HP, (HPT) 35% HP + 1% TiF4 and (CT) control. Bleaching with HP was performed in 3 sessions (3 × 15 min/applications). pH, colorimetric parameters, surface roughness, mineral content and enamel morphology were determined. The pH was evaluated for 45 min. The color parameters were determined before bleaching (T0), and 14 days elapsed from the last bleaching session (T4). Surface roughness was analyzed at T0 and immediately after last bleaching session (T3). Enamel mineral content and morphology were verified at T4. Data were statistically analyzed by one-way, two-way ANOVA and Kruskal-Wallis (α = 0.05). RESULTS: TiF increased surface roughness, and no differences between HP and HPT in terms of color and CO 3 2 - $$ {\mathrm{CO}}_3^{2-} $$ - PO 4 3 - $$ {\mathrm{PO}}_4^{3-} $$ mineral content. Ti was detected only on TiF, and slight surface morphology changes were observed in bleached enamel. CONCLUSIONS: The combination of TiF4 and 35% HP did not interfere with the enamel bleaching effect, controlled surface roughness, and kept mineral content but promoted a minor surface morphology alteration. CLINICAL SIGNIFICANCE: Due to the adverse effects of bleaching, titanium tetrafluoride (TiF4) has gained attention for its therapeutic properties, including the ability to reverse mineral loss and neutralize remineralization of mineral structures. Therefore, TiF4's remineralizing capacity may be a good alternative for incorporation into hydrogen peroxide bleaching agents.

3.
J Esthet Restor Dent ; 34(3): 490-502, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34623017

RESUMO

OBJECTIVE: To answer the question: "Does the peroxide gel application regimen (single application vs. renewal) influence the efficacy and the tooth sensitivity outcomes of in-office tooth bleaching?" METHODS: The search was done in Pubmed, Cochrane, LILACS, Scopus, Web of Science, and EMBASE in February 2021 (updated in July 2021). Randomized clinical trials (RCT) comparing the single application vs. the renewal protocols of HP were included. The meta-analyses were performed for the objective (ΔEab ), subjective (ΔSGU) color changes, and absolute risk of tooth sensitivity (TS). Heterogeneity was evaluated using Q test (I2 ). Cochrane Collaboration tool assessed the risk of bias (RoB). The GRADE evaluated the certainty of evidence. RESULTS: Five RCT studies remained. Two studies showed high RoB, and three presented some concerns. No significant differences were observed between the protocols in terms of the ΔEab , ΔSGU, and TS. ΔEab exhibited substantial heterogeneity (I2  = 87%), while ΔSGU (I2  = 60%) and the TS (I2  = 62%) presented a moderate one. The certainty of evidence was considered low or very low, depending on the variable response and the evaluation time. CONCLUSION: The application regimen (single vs. renewal of HP) did not impact color change or the absolute risk of TS. CLINICAL SIGNIFICANCE: The renewal of bleaching gel during the in-office appointment may not be necessary. However, there is at least a low certainty of evidence. Because of this, further randomized clinical trials with appropriate methodology on this topic are encouraged.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Peróxido de Hidrogênio , Peróxidos , Clareamento Dental/métodos , Resultado do Tratamento
4.
J Esthet Restor Dent ; 34(7): 1051-1059, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35644927

RESUMO

OBJECTIVES: To evaluate the influence of dentin pretreatments on the push-out bond strength (POBS) of self-adhesive resin cements (SARCs) to radicular dentin. MATERIALS AND METHODS: Two experimental pretreatments (2.5% titanium tetrafluoride (TiF4 ) and 26% polyacrylic acid (PA)) and two SARCs: Maxcem Elite (MAX) and Calibra Universal (CAL) were used. For each cement, a control group was applied as indicated by the manufacturer. Sixty bovine incisors were restored (n = 10) and subjected to POBS evaluation. Failure mode, adhesive interface and surface morphology were analyzed by a Scanning Electron Microscopy (SEM) and resin infiltration was performed by confocal laser scanning microscopy (CLSM). Data for POBS and CLSM were analyzed by three-way ANOVA and Bonferroni post-hoc (α = 0.05). RESULTS: For MAX, both experimental pretreatments resulted in increased POBS in the cervical third, and for CAL, only the PA resulted in higher POBS in the cervical third. The most failures occurred between the dentin and the resin cement, except when TiF4 was applied. For PA, analysis of surface morphology showed open dentinal tubules, while TiF4 presented particle agglomerates. SEM and CLSM images confirmed presence of resin tags for both pretreatments. CONCLUSION: Pretreating radicular dentin with PA and TiF4 solutions improves the bond strength of SARCs.


Assuntos
Colagem Dentária , Cimentos de Resina , Animais , Bovinos , Colagem Dentária/métodos , Cimentos Dentários/química , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/química , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície
5.
J Esthet Restor Dent ; 34(1): 55-64, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34859939

RESUMO

OBJECTIVE: This study comprehensively reviewed clinical trials that investigated the effect of immediate dentin sealing (IDS) technique on postoperative sensitivity (POS) and clinical performance of indirect restorations. MATERIALS AND METHODS: The systematic review was conducted according to the preferred reporting items for systematic reviews and meta-analyses statement, and was guided by the PICOS strategy. Clinical trials in which adult patients received at least one indirect restoration cemented with IDS approach and one restoration cemented following the delayed dentin sealing (DDS) were considered. RESULTS: Following title screening and full-text reading, four studies met the inclusion criteria and were included for qualitative synthesis, while two studies were selected for quantitative synthesis. According to Risk of bias-2 tool, two studies were classified as "some concerns" for the outcome POS. No statistically significant differences were found between teeth restored with indirect restorations using the IDS and DDS approach for POS (p > 0.05), neither at the baseline (very low certainty of evidence according to GRADE) nor after 2 years of follow-up (low certainty of evidence according to GRADE). CONCLUSION: There is low-certainty evidence that IDS does not reduce POS in teeth restored with indirect restorations. CLINICAL SIGNIFICANCE: There is no clinical evidence to favor IDS over DDS when restoring teeth with indirect restorations.


Assuntos
Dentina , Dente Molar , Adulto , Resinas Compostas , Humanos
6.
J Evid Based Dent Pract ; 22(1): 101682, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35219459

RESUMO

OBJECTIVE: This systematic review and meta-analyses aimed to evaluate the potential protective effect of titanium tetrafluoride (TiF4) compound compared to sodium fluoride (NaF) on eroded enamel or dentin. METHODS: Two independent reviewers searched PubMed, Scopus, Web of Science, LILACS, Cochrane, EMBASE, and Open gray Literature up to June 2020. MeSH terms, supplementary concepts, synonyms, and free terms were applied based on PICOS strategy (P- population: eroded enamel or dentin; I- intervention: eroded teeth treated with solution or varnish of TiF4; C- comparison: eroded teeth treated with a solution or varnish of NaF; O- outcome: mineral loss measurement; S- study design: in vitro studies). Seven distinct parameters evaluated the risk of bias, and all studies were submitted to 4 meta-analyses (first and second meta-analyses related to enamel loss treated with fluoride solution or varnish, respectively; third and fourth meta-analyses related to dentin loss treated with fluoride solution or varnish, respectively). A sensitivity test was performed by the RevMan software, based on standard mean difference calculation (P < .05). RESULTS: A total of 10,260 studies were retrieved, from which 22 studies were included in systematic review through eligibility criteria, of which 1 study was classified as low risk of bias, 19 as medium, and 3 as high. Seventeen studies were included in 4 different meta-analyses, presenting considerable overall heterogeneity (I2 = 95; 92; 95; and 93%, respectively) with statistical significance for TiF4 on the first meta-analysis, and no statistical significance for second, third, and fourth meta-analyses. CONCLUSIONS: Titanium tetrafluoride compound delivered as solution provided significant effective protection for erosion lesions on the enamel surface compared to sodium fluoride. However, when TiF4 or NaF were applied on enamel or dentin surfaces as varnish, both provided the same effective protection, based on in vitro studies with considerable heterogeneity.


Assuntos
Fluoretos , Erosão Dentária , Cariostáticos/farmacologia , Cariostáticos/uso terapêutico , Fluoretos/farmacologia , Humanos , Fluoreto de Sódio/farmacologia , Titânio , Erosão Dentária/prevenção & controle
7.
J Esthet Restor Dent ; 33(2): 341-350, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32820846

RESUMO

OBJECTIVE: This randomized clinical trial evaluated the efficacy and safety of a blue-covarine whitening toothpaste on tooth bleaching. SUBJECTS AND METHODS: Seventy-five subjects with shade mean C1 or darker were randomized into three groups (n = 25): CT-conventional toothpaste, WT-whitening toothpaste, and CP10-10% carbamide peroxide. Subjects from CT and WT brushed their teeth twice/day for 2 weeks. CP10 used bleaching gel for 4 hours/night for 2 weeks. Tooth shade and CIELab parameters were measured at baseline, after the first application, 2- and 4-week. ΔE*ab and ΔE00 were calculated. Subjects' perception about tooth color appearance, tooth sensitivity (TS), and gingival irritation (GI) were also assessed. RESULTS: At all evaluation periods, it was not observed differences between WT and CT considering tooth shade (P > 0.7) or CIELab parameters (P > 0.3). At 2- and 4-week, ΔE*ab and ΔE00 were higher for CP10 than WT or CT (P = 0.001). WT and CT reported major dissatisfaction with tooth color appearance than CP10 (P = 0.001). At 1- and 2-week, WT experienced GI and TS similar to CT, both lower than CP10 (P < 0.01). CONCLUSION: There were no significant differences in the whitening efficacy between whitening and conventional toothpastes. Neither of the dentifrices was as effective as at-home bleaching. CLINICAL SIGNIFICANCE: The silica-based toothpaste containing blue covarine evaluated in this study did not give significant tooth whitening benefits over 2 weeks of use.


Assuntos
Metaloporfirinas , Clareamento Dental , Descoloração de Dente , Cor , Método Duplo-Cego , Humanos , Peróxido de Hidrogênio , Isoindóis , Peróxidos , Descoloração de Dente/tratamento farmacológico , Cremes Dentais , Resultado do Tratamento , Ureia
8.
Int J Esthet Dent ; 19(2): 186-194, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38726859

RESUMO

OBJECTIVE: A diagnostic mock-up is a key tool that allows a preview of the outcome of an esthetic restoration. With recent developments in CAD/CAM technology, it is important to understand the pros and cons of chairside digital dentistry and the restorative materials used. The aim of the present case report is to describe in detail the use of a 3D-printed mock-up fabricated from a polymer-based material for an esthetic treatment plan within a fully digital workflow. CASE REPORT: A 45-year-old female patient presented at the clinic concerned about her esthetic appearance and the color of her anterior incisors. After a conclusive diagnosis, a restoration was planned using ceramic veneers from maxillary premolar to premolar. For a preview visualization of the outcome, an intraoral scanner was used to obtain 3D images and to allow the design of a digital smile. The template STL file was exported to a 3D printer and a 0.6-mm mock-up in A3-shade 3D resin was produced after 25 min. The mock-up was tested through a try-in and approved by the patient. As a result, the printed mock-up was considered predictable and reliable for the final restoration. CONCLUSIONS: The ease, speed, and reduced costs derived from the digital workflow, in conjunction with the accuracy of the mock-up, made the procedure highly efficient and recommendable.


Assuntos
Desenho Assistido por Computador , Estética Dentária , Impressão Tridimensional , Humanos , Feminino , Pessoa de Meia-Idade , Facetas Dentárias , Planejamento de Prótese Dentária/métodos , Cerâmica , Incisivo/diagnóstico por imagem
9.
Restor Dent Endod ; 49(2): e18, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38841382

RESUMO

Objectives: This study was conducted to evaluate the mechanical properties of relined and non-relined fiberglass posts when cemented to root canal dentin using a conventional dual-cure resin cement or a self-adhesive resin cement. Materials and Methods: Two types of resin cements were utilized: conventional and self-adhesive. Additionally, 2 cementation protocols were employed, involving relined and non-relined fiberglass posts. In total, 72 bovine incisors were cemented and subjected to push-out bond strength testing (n = 10) followed by failure mode analysis. The cross-sectional microhardness (n = 5) was assessed along the root canal, and interface analyses (n = 3) were conducted using scanning electron microscopy (SEM). Data from the push-out bond strength and cross-sectional microhardness tests were analyzed via 3-way analysis of variance and the Bonferroni post-hoc test (α = 0.05). Results: For non-relined fiberglass posts, conventional resin cement exhibited higher push-out bond strength than self-adhesive cement. Relined fiberglass posts yielded comparable results between the resin cements. Type II failure was the most common failure mode for both resin cements, regardless of cementation protocol. The use of relined fiberglass posts improved the cross-sectional microhardness values for both cements. SEM images revealed voids and bubbles in the incisors with non-relined fiberglass posts. Conclusions: Mechanical properties were impacted by the cementation protocol. Relined fiberglass posts presented the highest push-out bond strength and cross-sectional microhardness values, regardless of the resin cement used (conventional dual-cure or self-adhesive). Conversely, for non-relined fiberglass posts, the conventional dual-cure resin cement yielded superior results to the self-adhesive resin cement.

10.
Polymers (Basel) ; 16(14)2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-39065398

RESUMO

Graphene is a promising biomaterial. However, its dispersion in aqueous medium is challenging. This study aimed to modify graphene nanoparticles with L-dopa to improve the properties of experimental dental adhesives. Adhesives were formulated with 0% (control), 0.25%, 0.5%, and 0.75% of graphene, modified or not. Particle modification and dispersion were microscopically assessed. Degree of conversion was tested by Fourier-transform infrared spectroscopy. Flexural strength and modulus of elasticity were evaluated by a 3-point flexural test. Bond strength was tested by shear. To test water sorption/solubility, samples were weighed during hydration and dehydration. Antibacterial activity was tested by Streptococcus mutans colony-forming units quantification. Cytotoxicity on fibroblasts was evaluated through a dentin barrier test. The modification of graphene improved the particle dispersion. Control presented the highest degree of conversion, flexural strength, and bond strength. In degree of conversion, 0.25% of groups were similar to control. In bond strength, groups of graphene modified by L-dopa were similar to Control. The modulus of elasticity was similar between groups. Cytotoxicity and water sorption/solubility decreased as particles increased. Compared to graphene, less graphene modified by L-dopa was needed to promote antibacterial activity. By modifying graphene with L-dopa, the properties of graphene and, therefore, the adhesives incorporated by it were enhanced.

11.
Polymers (Basel) ; 16(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38891413

RESUMO

BACKGROUND: This study investigated effects of rapid high-intensity light-curing (3 s) on increasing transdentinal temperature and cell viability. METHODS: A total of 40 dentin discs (0.5 mm) obtained from human molars were prepared, included in artificial pulp chambers (4.5 × 5 mm), and subjected to four light-curing protocols (n = 5), with a Valo Grand light curing unit: (i) 10 s protocol with a moderate intensity of 1000 mW/cm2 (Valo-10 s); (ii) 3 s protocol with a high intensity of 3200 mW/cm2 (Valo-3 s); (iii) adhesive system + Filtek Bulk-Fill Flow bulk-fill composite resin in 10 s (FBF-10 s); (iv) adhesive system + Tetric PowerFlow bulk-fill composite resin in 3 s (TPF-3 s). Transdentinal temperature changes were recorded with a type K thermocouple. Cell viability was assessed using the MTT assay. Data were analyzed using one-way ANOVA and Tukey tests for comparison between experimental groups (p < 0.05). RESULTS: The 3 s high-intensity light-curing protocol generated a higher temperature than the 10 s moderate-intensity standard (p < 0.001). The Valo-10 s and Valo-3 s groups demonstrated greater cell viability than the FBF-10s and TPF-3 s groups and statistical differences were observed between the Valo-3 s and FBF-10 s groups (p = 0.023) and Valo-3 s and TPF-3 s (p = 0.025), with a potential cytotoxic effect for the FBF-10 s and TPF-3 s groups. CONCLUSIONS: The 3 s rapid high-intensity light-curing protocol of bulk-fill composite resins caused a temperature increase greater than 10 s and showed cell viability similar to and comparable to the standard protocol.

12.
Polymers (Basel) ; 16(15)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39125196

RESUMO

The objective was to compare the color match and color stability behavior of single- and multi-shade resin-based composites (RBCs) used for direct restorations. This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Randomized clinical trials evaluating the shade performance of single-shade RBCs in direct restorations were included. A search of the scientific literature was performed in five databases (April 2024). The meta-analysis was performed using RevMan 5.4, calculating the risk difference (RD) and 95% confidence interval (CI) of the dichotomous outcome using a random effects model. Bias was assessed using the RoB 2.0 tool, and certainty of evidence was assessed using the GRADEpro tool. Four studies were selected, with 263 restorations analyzed. The results showed comparable performance between single-shade RBCs and multi-shade RBCs in terms of color match and color stability over 12 months. Three studies had a low risk of bias with all expected results, and one study had some concerns. The certainty of evidence for color stability was considered low for all follow-up periods due to the small number of events and sample size. According to the United States Public Health Service Evaluation (USPHS) and the World Dental Federation (FDI), there is comparable clinical color performance between single-shade and multi-shade RBCs over 12 months.

13.
J Clin Exp Dent ; 16(7): e898-e911, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39219826

RESUMO

Background: This scoping review aims to analyze the impact of rapid high-intensity light-curing on a new bulk-fill resin-based composites (RBCs) designed for this type of polymerization. Material and Methods: This scoping review was reported according to the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) and Joanna Briggs Institute Manual of Evidence Synthesis. The methods were registered on the Open Science Framework (). The literature search was conducted in PubMed/MEDLINE, Embase, Web of Science, Scopus and Cochrane Library databases. Eligibility was considered for in vitro and clinical studies evaluating the effects of ultra-fast high-intensity light-curing on a new system of bulk-fill RBCs. Results: Of 1.688 articles identified, 27 were included in the qualitative synthesis. All studies were conducted in vitro. A total of 2.432 specimens were evaluated. The studies have shown that shortness light-curing may result in similar properties (stress generated by polymerization shrinkage, marginal integrity, and bond strength to dental interface) for the new bulk-fill RBCs. Conclusions: Therefore, the new bulk-fill RBCs can be light-cured with a short exposure time and high intensity, providing a time-saving benefit in clinical practice, with similar results to standard light-curing in conventional composites, although, its use should be approached with caution in the flowable composite. Key words:Resin composites, polymerization, dental materials, review.

14.
Clin Cosmet Investig Dent ; 16: 191-199, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38835853

RESUMO

Objective: This study aimed to evaluate the bond strength of a universal adhesive to dentin (µTBS) using different time periods of airborne particle abrasion (APA) and two types of acid etching. Methods: Seventy-two human third molars were divided into 9 groups (n=8) according to dentin pretreatment: APA duration (0, 5, or 10s) and acid etching (no acid - NA, 37% phosphoric acid - PhoA, or 1% phytic acid - PhyA). APA was performed at a 0.5 cm distance and air pressure of 60 psi using 50 µm aluminum oxide particles. Afterwards, two coats of Single Bond Universal adhesive (3M) were applied to the dentin surface. Composite blocks were built using the incremental technique, sectioned into 1×1 mm slices and subjected to microtensile bond strength (µTBS) testing. Fracture patterns and surface topography of each dentinal pretreatment were evaluated using a Scanning electron microscope (SEM). Bond strength data were analyzed using two-way ANOVA and Bonferroni post-hoc tests. Results: The group that received pretreatment with 5s APA and PhoA presented higher µTBS values among all groups, which was statistically different when compared with the PhoA, 10APA+PhoA, and 5APA+PhyA groups. PhyA did not significantly influence the bond strength of the air-abraded groups. Finally, adhesive failure was considered the predominant failure in all groups. Conclusion: Dentin pretreated by airborne particle abrasion using aluminum oxide demonstrated an increase in bond strength when abraded for 5 seconds and conditioned with phosphoric acid in a universal adhesive system.

15.
Crit Rev Oncol Hematol ; 186: 103988, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37086955

RESUMO

Traditional therapeutic approaches for malignant melanoma, have proved to be limited and/or ineffective, especially with respect to their role in improving patient survival and tumor recurrence. In this regard, immunotherapy has been demonstrated to be a promising therapeutic alternative, boosting antitumor responses through the modulation of cell signaling pathways involved in the effector mechanisms of the immune system, particularly, the so-called "immunological checkpoints". Clinical studies on the efficacy and safety of immunotherapeutic regimens, alone or in combination with other antitumor approaches, have increased dramatically in recent decades, with very encouraging results. Hence, this review will discuss the current immunotherapeutic regimens used to treat malignant melanoma, as well as the molecular and cellular mechanisms involved. In addition, current clinical studies that have investigated the use, efficacy, and adverse events of immunotherapy in melanoma will also be discussed.


Assuntos
Melanoma , Neoplasias Cutâneas , Humanos , Melanoma/tratamento farmacológico , Neoplasias Cutâneas/genética , Neoplasias Cutâneas/terapia , Imunoterapia/métodos , Melanoma Maligno Cutâneo
16.
Int J Infect Dis ; 126: 94-97, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36427702

RESUMO

INTRODUCTION: Fungal infections of the central nervous system present a variety of clinical syndromes, such as meningitis, encephalitis, raised intracranial pressure with a nonspecific presentation, and, in the last two decades, have increased the incidence of these fungal infections. Fungal meningoencephalitis is frequently associated with Cryptococcus, but this report stands out for presenting one species of Penicillium genus. OBJECTIVES: Here, we present the first case of meningoencephalitis associated with brain injury caused by Penicillium chrysogenum, in a patient who is immunocompetent and was admitted to Hospital Naval Marcílio Dias, Rio de Janeiro, Brazil. METHODS: To identify the fungal species, we performed phenotypic and genotypic methodologies, from the culture to the sequencing of internal transcribed spacer region, and ß-tubulin gene, a rare fungus in cerebrospinal fluid cultures, belonging to the genus Penicillium, was identified. CONCLUSION: We highlight the importance of the first report of meningoencephalitis caused by P. chrysogenum in a patient who is immunocompetent, registered in Brazil. We also emphasize the need for further studies to determine an effective treatment with the least possible side effects for patients infected by fungi that are rarely related to the most severe forms of invasive infections.


Assuntos
Meningite , Meningoencefalite , Micoses , Penicillium chrysogenum , Penicillium , Humanos , Penicillium chrysogenum/genética , Brasil/epidemiologia , Meningoencefalite/diagnóstico , Meningoencefalite/tratamento farmacológico , Penicillium/genética
17.
Gels ; 8(3)2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35323291

RESUMO

This in vitro study evaluated color change, mineral content, and morphology of enamel, pH and cytotoxicity of experimental bleaching agents containing 35% hydrogen peroxide (HP), titanium tetrafluoride (TiF4), Natrosol, and Chemygel. Sixty enamel/dentin blocks were randomly treated with (n = 10) HP; HP+Natrosol+Chemygel with different TiF4 concentrations: 0.05 g HPT0.5, 0.1 g HPT1, 0.2 g HPT2, 0.3 g HPT3, 0.4 g HPT4. Bleaching was performed in three sessions (3 × 15 min application). Color change (CIELab-ΔEab, CIEDE2000-ΔE00, ΔWID) and Knoop microhardness (KHN) were evaluated. Enamel morphology and composition were observed under scanning electron microscopy and energy-dispersive spectrometry (EDS), respectively. Cell viability of keratinocyte cells was evaluated using MTT assay. Data were analyzed by one-way ANOVA and LSD and Tukey tests, and two-way repeated measures ANOVA and Bonferroni (α = 5%). The pH and EDS were analyzed descriptively. Lightness-L* increased, and a* and b* parameters decreased, except for HPT3 and HPT4 (b*). HPT0.5, HPT1, and HPT2 exhibited ΔEab and ΔWID similar to HP. ΔE00 did not present statistical difference. HP, HPT0.5, and HPT1 promoted higher KHN. HPT0.5 exhibited no changes on enamel surface. Keratinocyte cells were viable when treated with T0.5, and weak viable for T1. Experimental agents exhibited acidic pH and Ti elements. HPT0.5 exhibited bleaching efficacy, maintained KHN without enamel alterations, and did not increase cytotoxicity.

18.
Restor Dent Endod ; 47(3): e32, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36090509

RESUMO

Objectives: This study aimed to evaluate the influence of inorganic composition and filler particle morphology on the mechanical properties of different self-adhesive resin cements (SARCs). Materials and Methods: Three SARCs including RelyX Unicem-2 (RUN), Maxcem Elite (MAX), and Calibra Universal (CAL) were tested. Rectangular bar-shaped specimens were prepared for flexural strength (FS) and flexural modulus (FM) and determined by a 3-point bending test. The Knoop microhardness (KHN) and top/bottom microhardness ratio (%KHN) were conducted on the top and bottom faces of disc-shaped samples. Sorption (Wsp) and solubility (Wsl) were evaluated after 24 hours of water immersion. Filler morphology was analyzed by scanning electron microscopy and X-ray energy dispersive spectroscopy (EDS). FS, FM, %KHN, Wsp, Wsl, and EDS results were submitted to 1-way analysis of variance and Tukey's post-hoc test, and KHN also to paired t-test (α = 0.05). Results: SARC-CAL presented the highest FS value, and SARC-RUN presented the highest FM. SARC-MAX and RUN showed the lowest Wsp and Wsl values. KHN values decreased from top to bottom and the SARCs did not differ statistically. Also, all resin cements presented carbon, aluminum, and silica in their composition. SARC-MAX and RUN showed irregular and splintered particles while CAL presented small and regular size particles. Conclusions: A higher mechanical strength can be achieved by a reduced spread in grit size and the filler morphology can influence the KHN, as well as photoinitiators in the composition. Wsp and Wsl can be correlated with ions diffusion of inorganic particles.

19.
Braz J Infect Dis ; 26(5): 102703, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36100081

RESUMO

With the emergence of new variants of SARS-CoV-2, questions about transmissibility, vaccine efficacy, and impact on mortality are important to support decision-making in public health measures. Modifications related to transmissibility combined with the fact that much of the population has already been partially exposed to infection and/or vaccination, have stimulated recommendations to reduce the isolation period for COVID-19. However, these new guidelines have raised questions about their effectiveness in reducing contamination and minimizing impact in work environments. Therefore, a collaborative task force was developed to review the subject in a non-systematic manner, answering questions about SARS-CoV-2 variants, COVID-19 vaccines, isolation/quarantine periods, testing to end the isolation period, and the use of masks as mitigation procedures. Overall, COVID-19 vaccines are effective in preventing severe illness and death but are less effective in preventing infection in the case of the Omicron variant. Any strategy that is adopted to reduce the isolation period should take into consideration the epidemiological situation of the geographical region, individual clinical characteristics, and mask for source control. The use of tests for isolation withdrawal should be evaluated with caution, due to results depending on various conditions and may not be reliable.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Humanos , Quarentena , SARS-CoV-2/genética
20.
J Adhes Dent ; 23(5): 409-420, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34549924

RESUMO

PURPOSE: This study evaluated dentin bond strength, failure mode, interface morphology, adhesive infiltration into dentin, and marginal adaptation of bulk-fill composites used with different adhesives. MATERIALS AND METHODS: Third molars received occlusal class I cavities (4 mm x 4 mm x 4 mm) that were bulk-filled with Admira Fusion x-tra (Voco) or SonicFill 2 (Kerr) using four adhesives (Scotchbond Multipurpose, 3M Oral Care; Clearfil SE Bond, Kuraray Noritake; OptiBond All-In-One, Kerr; Futurabond U, Voco). Scotchbond was used with acid-etching, while the remaining adhesives were applied in self-etch mode. Sixty-four teeth were selected for the microtensile bond strength test (n = 8). Failure modes were analyzed with scanning electron microscopy (SEM). Interface morphology and adhesive infiltration (n = 3) were investigated using confocal laser scanning microscopy (CLSM). Marginal adaptation (n = 3) was also evaluated using SEM. Bond strength, failure mode, and adhesive infiltration data were analyzed for distribution and homocedasticity, followed by appropriate statistical analyses (α = 0.05). RESULTS: Regarding bond strength, no differences were found among adhesives for SonicFill; Clearfil showed a significantly lower mean value than did Scotchbond (p ≤ 0.05) for Admira; the two composites did not differ. Adhesive and mixed failures were observed for all groups. Scotchbond led to thicker hybrid layers with deeper adhesive infiltration as opposed to Futurabond. The groups Admira+Futurabond, SonicFill+Clearfil, and SonicFill+Futurabond presented the highest marginal discontinuity. CONCLUSION: The tested bulk-fill composites did not affect dentin bonding. Scotchbond and Clearfil seem to be reliable for bonding SonicFill 2 to dentin. The performance of Futurabond was questionable, given its poor-quality interface and higher percentages of marginal gaps.


Assuntos
Colagem Dentária , Adesivos Dentinários , Adesivos , Resinas Compostas , Cimentos Dentários , Dentina , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA