Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Opt Express ; 29(22): 34913-34925, 2021 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-34808940

RESUMO

We present γ-ray radiation detection in a neutron radiation environment using a monolithic active pixel sensor (MAPS) camera without conversion or shielding layers. The measured output signal is the sum of the pedestal value, noise, and real radiation response signal. The sensor response shows that the MAPS camera is sensitive to neutrons and can capture a single photon. The number of pixels with a signal exceeding 100 exhibits a strong dependence on the dose rate and is the best indicator of this value. Therefore, a MAPS camera can be efficiently used as a radiation detection sensor in a robotic system, further limiting human errors in performing radiation detection in complex nuclear radiation environments.

2.
Sci Rep ; 14(1): 16625, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39025940

RESUMO

In order to evaluate the beneficiation plant environment in a more scientific and reasonable way, this paper took the workshop environment of the beneficiation plant as the research object. This paper divided the beneficiation plant into 7 evaluation units according to its functions. The evaluation indices are dust, noise, light environment, microclimate, benzene, toluene and xylene. This paper combines the G1 method and the entropy weight method to evaluate the weight of each evaluation index, the element extension model of the concentrator working environment is established by the element analysis method, and the matter element analysis method is used to establish an evaluation index system of a beneficiation plant in East China. The results show that the evaluation level of the breaking workshop and the auxiliary facilities are unqualified, the auxiliary facility is qualified, the culling workshop, culled yard and accessory building are medium, the screening workshop and grinding workshop are good.

3.
Medicine (Baltimore) ; 99(25): e20139, 2020 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-32569159

RESUMO

We aimed to assess the usefulness of slice-encoding metal artifact correction (SEMAC) for the evaluation of spinal metallic implants and peripheral soft tissue lesions at 3T magnetic resonance.Twenty-seven patients with spinal metal implants underwent both SEMAC and high bandwidth (HiBW) based sequences scanning for reduction artifacts. The area size and maximum longitude of artifacts, the peri-prosthetic soft tissue, and metal visualization were assessed by 2 independent doctors, as well as the lesions signs were reviewed by 2 senior readers. A paired 2-tailed t-test and McNemar test were used for statistical analysis.The size of artifacts on SEMAC images decreased by 37% and 24%, and the scores are higher than that on HiBW images. T1 weighted (T1W)-SEMAC acquired the highest score in metal prosthesis visualization, while short tau inversion recovery SEMAC showed more signs of lesions than clinical HiBW group.SEMAC effectively reduces the metal artifacts and is useful for assessing soft tissue lesions.


Assuntos
Imageamento por Ressonância Magnética/métodos , Dispositivos de Fixação Ortopédica , Complicações Pós-Operatórias/diagnóstico por imagem , Lesões dos Tecidos Moles/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Idoso , Artefatos , Feminino , Fixação de Fratura/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Melhoria de Qualidade , Fraturas da Coluna Vertebral/cirurgia
4.
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue ; 15(5): 268-71, 2003 May.
Artigo em Chinês | MEDLINE | ID: mdl-12837184

RESUMO

OBJECTIVE: To study the effects of thyrotropin-releasing hormone (TRH) in combination with hypertonic saline/dextran (7.5% NaCl + 6% Dextran 40, HSD ) on hemorrhagic shock with pulmonary edema in the rats which were recently brought to high altitude. METHODS: Forty-nine SD rats, transported to Lasa, Tibet, which was 3,760 meters above the sea level, were anesthetized one week later with sodium pentobarbital (30 mg/kg, intraperitoneal). Hemorrhagic shock with pulmonary edema was induced by hemorrhage (50 mm Hg maintained for 1 hour,1 mm Hg=0.133 kPa) plus intravenous injection of oleic acid (50 microl/kg). They were equally divided into seven groups (n=7): normal control, hemorrhagic shock, hemorrhagic shock with pulmonary edema (HSPE), HSPE plus TRH (5 mg/kg), HSPE plus HSD (4 ml/kg), and HEPE plus TRH and HSD in combination. Hemodynamic parameters including mean arterial blood pressure(MAP), left intraventricular systolic pressure (LVSP) and the maximal change rate of intraventricular pressure rise or decline (+/- dp/dt max) were observed at 15, 30, 60 and 120 minutes, blood gases were analyzed at 30 and 120 minutes, and the water content of lung and brain was determined at 120 minutes after drug administration. RESULTS: TRH or HSD used alone or in combination significantly increased MAP, LVSP and +/- dp/dt max (P<0.05 or P<0.01 ), ameliorated acid-base imbalance, and decreased the water content of lung and brain. The effect of the two in combination was superior to either drug used alone. CONCLUSION: TRH in combination with HSD can be used in the treatment of hemorrhagic shock with pulmonary edema at high altitude.


Assuntos
Altitude , Edema Pulmonar/tratamento farmacológico , Solução Salina Hipertônica/uso terapêutico , Choque Hemorrágico/tratamento farmacológico , Hormônio Liberador de Tireotropina/uso terapêutico , Animais , Edema Pulmonar/complicações , Ratos , Ratos Sprague-Dawley , Solução Salina Hipertônica/administração & dosagem , Choque Hemorrágico/complicações , Hormônio Liberador de Tireotropina/administração & dosagem
5.
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue ; 15(5): 279-83, 2003 May.
Artigo em Chinês | MEDLINE | ID: mdl-12837187

RESUMO

OBJECTIVE: To study the effects of different volumes of fluid resuscitation on hemorrhagic shock with pulmonary edema at high altitude in the unacclimated rat. METHODS: One hundred and twenty-six SD rats transported to Lasa, Tibet, 3 760 meters above the sea level, were anesthetized one week later with sodium pentobarbital (30 mg/kg, intraperitoneal). Hemorrhagic shock with pulmonary edema model was induced by hemorrhage (50 mm Hg for 1 hour, 1 mmHg=0.133 kPa) plus intravenous injection of oleic acid (50 microl/kg). Experiments were then conducted in two parts. Sixty-three rats in part I were equally divided into nine groups (n=7): normal control, hemorrhagic shock control, hemorrhagic shock with pulmonary edema (HSPE) without fluid infusion, HSPE plus infusing lactated Ringer's solution (LR) with 0.5-, 1-, 1.5-, 2- or 3- fold volume shed blood, and 1 volume of LR plus mannitol (10 ml/kg). Hemodynamic parameters including mean arterial blood pressure (MAP), left intraventricular systolic pressure (LVSP) and the maximal change rate of intraventricular pressure rise or decline (+/- dp/dt max) were observed at 15, 30, 60 and 120 minutes after infusion, blood gases were measured at 30 and 120 minutes after infusion and the water content of lung and brain was determined at 120 minutes after infusion. In part II, additional 63 rats were used to observe the effect of different volumes of fluid resuscitation on survival time of HSPE rats. RESULTS: 0.5 volume of LR infusion significantly improved MAP, LVSP and +/- dp/dt max, prolonged the survival time of HSPE animals (all P<0.01), while it did not increase the water content of lung and brain and had no marked influence on blood gases. One volume of LR infusion slightly improved hemodynamic parameters, prolonged the survival time and increased the water content of lung. More than 1 volume of LR infusion including 1.5-, 2- and 3- fold volume LR deteriorated the hemodynamic parameters and decreased the survival time of shocked animal, meanwhile they apparently increased the water content of lung. One volume of LR plus mannitol (10 ml/kg) infusion did not improve the hemodynamic parameters and blood gases; also it did not decrease the water content of lung. CONCLUSION: The tolerance to fluid infusion for the unacclimated animal subjected to hemorrhagic shock with pulmonary edema at high altitude is significantly decreased. 0.5-1 volume of LR infusion appears to be beneficial effect on resuscitation at high altitude, while over 1 volume of LR infusion would aggravate pulmonary edema and exacerbate fluid resuscitation effect.


Assuntos
Altitude , Soluções Isotônicas/uso terapêutico , Edema Pulmonar/terapia , Choque Hemorrágico/terapia , Animais , Feminino , Hidratação , Soluções Isotônicas/administração & dosagem , Masculino , Edema Pulmonar/complicações , Ratos , Ratos Sprague-Dawley , Ressuscitação , Solução de Ringer , Choque Hemorrágico/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA