Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 147
Filtrar
1.
Anal Chem ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136334

RESUMO

This study addresses the widespread use of UV filters (UVFs) in cosmetic and solar products due to the negative effects of UV radiation, particularly in relation to melanoma risk. While these filters offer protection, their extensive application raises concerns about their environmental and health impacts. Organic UVFs, in particular, have been associated with endocrine disruption in aquatic species and coral reef damage. To mitigate these concerns, regulatory limits have been imposed on certain UVFs. Current analytical techniques for UVF determination, such as HPLC-PDA and HPLC-MS/MS, offer high accuracy but are expensive and lack on-site monitoring capabilities. In response, this research aims to develop a rapid and cost-effective method, utilizing voltammetry for organic UVF quantification in complex matrices like sunscreens. Additionally, HPLC-PDA and HPLC-MS/MS are employed for electrochemical methods and device validation. This approach not only addresses the need for efficient UVF analysis but also provides a basis for regulatory compliance and environmental stewardship in the cosmetics industry.

2.
Electrophoresis ; 45(1-2): 55-68, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37495859

RESUMO

Separation and identification of chiral molecules is a topic widely discussed in the literature and of fundamental importance, especially in the pharmaceutical and food fields, both from industrial and laboratory points of view. Several techniques are used to carry out these analyses, but high-performance liquid chromatography is often the "gold standard." The high costs of chiral columns, necessary for this technique, led researchers to look for an alternative, and capillary electrophoresis (CE) is a technique capable of overcoming some of the disadvantages of liquid chromatography, often providing comparable results in terms of sensitivity and robustness. We addressed this topic, already widely discussed in the literature, providing an overview of the last 6 years of the most frequent and recent applications of CE. To make the manuscript more effective, we decided to divide it into paragraphs that represent the main field of application, from enantioseparation in complex matrices (pharmacokinetic studies or toxicological dosage of drugs, analysis of environmental pollutants, and analyses of foods) to quality control analyses on pharmaceutical formulas. About these, which are the fields of most meaningful use, we mentioned some of the most innovative and performing methods, with a look to the future on the application of new materials used, such as chiral selectors, that can make these types of analyses accessible to all, reducing cost, time, and excessive use of toxic solvents.


Assuntos
Eletroforese Capilar , Eletroforese Capilar/métodos , Cromatografia Líquida , Estereoisomerismo , Cromatografia Líquida de Alta Pressão , Preparações Farmacêuticas
3.
Chirality ; 36(3): e23659, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38445305

RESUMO

Due to a great demand for amylose and cellulose polymeric chromatographic chiral columns, the enantiomeric separation of thiourea derivatives of naringenin was achieved on the different amylose (Chiralpak-IB) and cellulose chiral (Chiralcel-OJ and Chiralcel-OD-3R) columns with varied chromatographic conditions. The isocratic mobile phases used were ethanol and methanol, where ethanol/hexane and methanol/hexane were used as gradient mode and were prepared in volume/volume relation. The separation and resolution factors for all the enantiomers were in the range of 1.25 to 3.47 and 0.48 to 1.75, respectively. The enantiomeric resolution was obtained within 12 min making fast separation. The docking studies confirmed the chiral recognition mechanisms with binding affinities in the range of -4.7 to -5.7 kcal/mol. The reported compounds have good anticoagulant activities and may be used as anticoagulants in the future. Besides, chiral separation is fast and is useful for enantiomeric separation in any laboratory in the world.


Assuntos
Amilose , Flavanonas , Hexanos , Metanol , Estereoisomerismo , Celulose , Polímeros , Etanol , Tioureia
4.
Oral Dis ; 2024 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-39314203

RESUMO

OBJECTIVE: Cold atmospheric plasma (CAP) is a novel approach for cancer treatment. It can be used to treat liquids-plasma-activated media (PAM)-which are then transferred to the target as an exogenous source of reactive oxygen and nitrogen species (RONS). The present study aimed at chemically characterizing different PAM and assessing their in vitro selectivity against head and neck cancer cells (HNC). METHODS: PAM were obtained by exposing 2 and 5 mL of cell culture medium to CAP for 5, 10 and 20 min at a 6 mm working distance. Anions kinetics was evaluated by ion chromatography. Cell proliferation inhibition, apoptosis occurrence, and cell cycle modifications were assessed by MTS and flow cytometry, on human epidermal keratinocyte (HaCaT) and HNC cell lines HSC3, HSC4 and A253. RESULTS: The 2 mL conditions showed a significant reduction in cell proliferation whereas for the 5 mL the effect was milder, but the time-dependence was more evident. HaCaT were unaffected by the 5 mL PAM, indicating a selectivity for cancer cells. CONCLUSIONS: The media chemical composition modified by CAP exposure influenced cell proliferation by modulating cell cycle and inducing apoptosis in cancer cells, without affecting normal cells.

5.
Biomed Chromatogr ; : e6004, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39237855

RESUMO

Thirteen flavanone racemates were successfully separated using a Chiralpak® IA column and isopropanol-hexane (50:50, v/v). The mobile phase flow rate and detection wavelength were 0.5 mL/min and 254 nm. The retention times values ranged from 5.50 and 56.45 min. The values of the retention, separation, and resolution factors ranged from 0.63 to 21.67, 1.12 to 2.45, and 0.13 to 11.94. The docking binding energies ranged from -6.2 to -8.2 kcal/mol, showing enthalpy-determined host-guest complex formation. The molecular docking results and the experimental data were agreed well. The results showed that S-enantiomers had stronger bindings with chiral selectors compared to R-enantiomers. Consequently, the R-enantiomers eluted first followed by S-enantiomers. The reported method is highly useful to determine the enantiomeric composition of the reported flavanone in any sample.

6.
Int J Mol Sci ; 25(16)2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39201424

RESUMO

Accuracy in the evaluation of death-induced tissue degradation for thanato-chronological purposes is strictly dependent on the condition of the biological source as well as on the precision of post-mortem interval (PMI) estimation. Thus, the optimization of tissue handling and identification of sensitive post-mortem biomarkers could help establish a timeline for post-mortem events. To this aim, we investigated the proteome changes in cortex samples of 6-week-old female SAMR1 mice over a post-mortem time course. After death, brain tissue was removed immediately (T0), and after 4, 8, 12, 24, and 32 h, four mice were used for each time period, and animals were maintained at 4 °C until brain removal. Dissected tissues were frozen at -80 °C until processed. Proteomic analysis, performed on samples related to early and late PMIs (<24 h and >24 h post-mortem, respectively) showed protein level changes as compared to T0 samples, with a remarkable increase in Calpain11 in the early PMI, as well as in Caspases 7 and 8 together with Gasdermin 3 in late PMI. These findings were confirmed by LIFT mass spectrometry technology and western blot analysis and, although requiring further investigation in other biological samples, suggest that these proteins could be considered as putative biomarkers of different PMIs.


Assuntos
Biomarcadores , Córtex Cerebral , Mudanças Depois da Morte , Proteômica , Animais , Camundongos , Biomarcadores/metabolismo , Proteômica/métodos , Feminino , Córtex Cerebral/metabolismo , Proteoma/metabolismo
7.
Pflugers Arch ; 475(6): 691-709, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37156970

RESUMO

Extracellular vesicles (EVs) enriched with bioactive molecules have gained considerable attention in nanotechnology because they are critical to intercellular communication while maintaining low immunological impact. Among biological matrices, urine has emerged as a noninvasive source of extracellular-contained liquid biopsy, currently of interest as a readout for physiological adaptations. Therefore, we aimed to evaluate chronic adaptations of endurance sport practice in terms of urinary EV parameters and evaluated by food consumption assessment. Two balanced groups of 13 inactive controls vs. triathlon athletes were enrolled; their urinary EVs were obtained by differential ultracentrifugation and analyzed by dynamic light scattering and transmission electron and atomic force microscopy. The cargo was analyzed by means of purine and miRNA content through HPLC-UV and qRT-PCR. Specific urinary EV signatures differentiated inactive versus endurance-trained in terms of peculiar shape. Particularly, a spheroid shape, smaller size, and lower roughness characterize EVs from triathletes. Metabolic and regulatory miRNAs often associated with skeletal muscle (i.e., miR378a-5p, miR27a-3p, miR133a, and miR206) also accounted for a differential signature. These miRNAs and guanosine in urinary EVs can be used as a readout for metabolic status along with the shape and roughness of EVs, novel informative parameters that are rarely considered. The network models allow scholars to entangle nutritional and exercise factors related to EVs' miRNA and purine content to depict metabolic signatures. All in all, multiplex biophysical and molecular analyses of urinary EVs may serve as promising prospects for research in exercise physiology.


Assuntos
Líquidos Corporais , Vesículas Extracelulares , MicroRNAs , Sistema Urinário , Humanos , MicroRNAs/metabolismo , Sistema Urinário/metabolismo , Vesículas Extracelulares/metabolismo , Líquidos Corporais/metabolismo , Purinas/metabolismo
8.
Anal Biochem ; 677: 115268, 2023 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-37524223

RESUMO

A polymer-based nanosensor and electrochemical methods were developed for the quantitative analysis of vanillin. The sample preparation was done using nano solid phase micro membrane tip extraction (NSPMMTE). A novel poly(phenylalanine)/TiO2/CPE sensor was built as the working electrode for the first time for the analysis of the vanillin substance. The electrochemical behavior and analytical performance of vanillin were examined in detail by cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV) techniques via the oxidation process. The optimized modules of the DPSV technique that affected the vanillin peak current and peak potential were pH, pulse amplitude, step potential, and deposition time. The electroactive surface areas of bare CPE, TiO2/CPE, and poly(phenylalanine)/TiO2/CPE electrodes were found to be 0.135 cm2, 0.155 cm2, and 0.221 cm2, respectively. The limit of detection (LOD) was 32.6 µg/L in the 0.25-15.0 mg/L working range at pH 7.0. The selectivity of the proposed DPSV method for the determination of vanillin on the modified electrode was investigated in the presence of various organic and inorganic substances, and the determination of vanillin with high recovery was achieved with less than 5% relative error. The analytical application was applied in chocolate samples and the DPSV method was found highly efficient, reproducible, and selective.


Assuntos
Chocolate , Titânio/química , Polímeros/química , Técnicas Eletroquímicas/métodos , Eletrodos , Carbono/química
9.
J Sep Sci ; 46(21): e2300582, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37675810

RESUMO

The extraction of berberine was carried out from Berberis vulgaris, Berberis aquifolium, and Hydrastis canadensis plants using ethanol and water (70:30, v/v). The extracted berberine was characterized by ultraviolet-visible and Fourier-transform infrared spectroscopy. The purity of berberine was ascertained by thin-layer chromatography using n-propanol-formic acid-water (95:1:4) and (90:1:9) solvents. hRf values were in the range of 44-49 with compact spots (diameter 0.2-0.4 cm). HPLC was carried out using ammonium acetate buffer and acetonitrile in gradient mode with Zodiac (4.6 × 150 mm, 3 µm) column. The flow rate was 1.0 mL/min and detection was at 220 nm. The values of separation and resolution factors of the standard and the extracted berberine were in the range of 1.13-1.16 and 1.40-1.71, respectively. A comparison has shown that both thin-layer chromatography and high-performance liquid chromatography (HPLC) methods found applications in different situations and requirements. The extracted berberine samples were used to treat Leishmaniosis and the results showed better activity of berberine in comparison to the standard drug Amphotericin B. Briefly, the reported research is a novel and may be used to extract berberine from plants, separation and identification of berberine by thin layer chromatography and HPLC and to treat Leishmaniosis.


Assuntos
Berberina , Berberina/química , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia em Camada Fina/métodos , Solventes/análise , Água
10.
Molecules ; 28(5)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36903374

RESUMO

Nowadays, it is vital to have new, complete, and rapid methods to screen and follow pharmacotoxicological and forensic cases. In this context, an important role is undoubtedly played by liquid chromatography-tandem mass spectrometry (LC-MS/MS) thanks to its advanced features. This instrument configuration can offer comprehensive and complete analysis and is a very potent analytical tool in the hands of analysts for the correct identification and quantification of analytes. The present review paper discusses the applications of LC-MS/MS in pharmacotoxicological cases because it is impossible to ignore the importance of this powerful instrument for the rapid development of pharmacological and forensic advanced research in recent years. On one hand, pharmacology is fundamental for drug monitoring and helping people to find the so-called "personal therapy" or "personalized therapy". On the other hand, toxicological and forensic LC-MS/MS represents the most critical instrument configuration applied to the screening and research of drugs and illicit drugs, giving critical support to law enforcement. Often the two areas are stackable, and for this reason, many methods include analytes attributable to both fields of application. In this manuscript, drugs and illicit drugs were divided in separate sections, with particular attention paid in the first section to therapeutic drug monitoring (TDM) and clinical approaches with a focus on central nervous system (CNS). The second section is focused on the methods developed in recent years for the determination of illicit drugs, often in combination with CNS drugs. All references considered herein cover the last 3 years, except for some specific and peculiar applications for which some more dated but still recent articles have been considered.


Assuntos
Drogas Ilícitas , Espectrometria de Massas em Tandem , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Medicina Legal , Monitoramento de Medicamentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA