1.
NMR Biomed ; 36(11): e5002, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37439129

RESUMO

The quality of cervical spinal cord images can be improved by the use of tailored radiofrequency (RF) coil solutions for ultrahigh field imaging; however, very few commercial and research 7-T RF coils currently exist for the spinal cord, and in particular, those with parallel transmission (pTx) capabilities. This work presents the design, testing, and validation of a pTx/Rx coil for the human neck and cervical/upper thoracic spinal cord. The pTx portion is composed of eight dipoles to ensure high homogeneity over this large region of the spinal cord. The Rx portion is made up of twenty semiadaptable overlapping loops to produce high signal-to-noise ratio (SNR) across the patient population. The coil housing is designed to facilitate patient positioning and comfort, while also being tight fitting to ensure high sensitivity. We demonstrate RF shimming capabilities to optimize B1 + uniformity, power efficiency, and/or specific absorption rate efficiency. B1 + homogeneity, SNR, and g-factor were evaluated in adult volunteers and demonstrated excellent performance from the occipital lobe down to the T4-T5 level. We compared the proposed coil with two state-of-the-art head and head/neck coils, confirming its superiority in the cervical and upper thoracic regions of the spinal cord. This coil solution therefore provides a convincing platform for producing the high image quality necessary for clinical and research scanning of the upper spinal cord.


Assuntos
Medula Cervical , Adulto , Humanos , Medula Cervical/diagnóstico por imagem , Imagens de Fantasmas , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Razão Sinal-Ruído
2.
NMR Biomed ; 31(8): e3944, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29928791

RESUMO

Neonatal brain injury suffered by preterm infants and newborns with some medical conditions can cause significant neurodevelopmental disabilities. MRI is a preferred method to detect these accidents and perform in vivo evaluation of the brain. However, the commercial availability and optimality of receive coils for the neonatal brain is limited, which in many cases leads to images lacking in quality. As extensively demonstrated, receive arrays closely positioned around the scanned part provide images with high signal-to-noise ratios (SNRs). The present work proposes a pneumatic-based MRI receive array that can physically adapt to infant head dimensions from 27-week premature to 1.5 months old. Average SNR increases of up to 68% in the head region and 122% in the cortex region, compared with a 32-channel commercial head coil, were achieved at 3 T. The consistent SNR distribution obtained through the complete coil size range, specifically in the cortex, allows the acquisition of images with similar quality across a range of head dimensions, which is not possible with fixed-size coils due to the variable coil-to-head distance. The risks associated with mechanical pressure on the neonatal head are minimal and the head motion is restricted. The method could be used in coil designs for other age groups, body parts and subjects.


Assuntos
Encéfalo/anatomia & histologia , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Simulação por Computador , Impedância Elétrica , Humanos , Recém-Nascido , Tamanho do Órgão , Imagens de Fantasmas , Razão Sinal-Ruído
3.
Magn Reson Imaging ; 50: 119-124, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29626518

RESUMO

Cardiac-related spinal cord motion affects diffusion-weighted (DWI) signal. The goal of this study was to further quantify the specific detrimental effect of cord translational motion on the DWI signal in order to make better informed decisions about the cost-benefit of cardiac gating. We designed an MRI-compatible phantom mimicking the spinal cord translational motion. Cardiac-gated DWI data were acquired by varying the trigger delay and the b-values. Evaluation of the effect of motion on the DWI signal was done by computing the apparent diffusion coefficient (ADC) along (z-direction) and orthogonal (y- and x-directions) to the phantom. The computed ADCs of the phantom moving along Z were similar for the three orthogonal diffusion-encoding directions, with an average value of 1.65·10-9 , 1.66·10-9 and 1.65·10-9 m2/s along X, Y and Z respectively. DW phase images on the other hand showed the expected linear relationship with phantom velocity. Pure translational motion has minor effect on the diffusion-weighted magnitude signal. The sudden signal drop typically observed in in vivo spinal cord DWI is likely not caused by translational motion of the spinal cord, and possibly originates from non-rigid compression/stretching of the cord and/or from intra-voxel incoherent motion (IVIM).


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Coração/fisiologia , Imagens de Fantasmas , Medula Espinal/diagnóstico por imagem , Humanos , Movimento (Física) , Reprodutibilidade dos Testes
4.
PLoS One ; 13(2): e0192035, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29390005

RESUMO

The purpose of this work was to develop an optimized transmit/receive birdcage coil to extend the possibilities of a 7T preclinical MRI system to conduct improved full body imaging in medium-sized animals, such as large New Zealand rabbits. The coil was designed by combining calculation and electromagnetic simulation tools. The construction was based on precise mechanical design and careful building practice. A 16-leg, 20 cm long, 16 cm inner diameter, shielded quadrature hybrid structure was selected. Coil parameters were assessed on the bench and images were acquired on phantoms and rabbits. The results were compared to simulations and data obtained with an available commercial coil. An inexpensive assembly with an increase of 2 cm in useful inner diameter and 50 Ω matching with larger animals was achieved. A reduction in radiofrequency (RF) power demand of 31.8%, an improvement in image uniformity of 18.5 percentage points and an increase in signal-to-noise ratio of up to 42.2% were revealed by phantom image acquisitions, which was confirmed by in vivo studies. In conclusion, the proposed coil extended the possibilities of a preclinical 7T system as it improved image studies in relatively large animals by reducing the RF power demand, and increasing image uniformity and signal-to-noise ratio. Shorter scans and time under anesthesia or reduced RF exposure, resulting in better images and lower animal health risk during in vivo experiments, were achieved.


Assuntos
Desenho de Equipamento , Imageamento por Ressonância Magnética/instrumentação , Animais , Imagens de Fantasmas , Coelhos