Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38818709

RESUMO

OBJECTIVE: To report our experience with 18F-fluoro-ethyl-tyrosine (FET) positron emission tomography-computed tomography (PET-CT) co-registered with magnetic resonance imaging (MRI) (FET-PET/MRICR) in the care trajectory for persistent acromegaly. DESIGN: Prospective case series. PATIENTS: Ten patients with insufficiently controlled acromegaly referred to our team to evaluate surgical options. MEASUREMENTS: FET-PET/MRICR was used to support decision-making if MRI alone and multidisciplinary team evaluation did not provide sufficient clarity to proceed to surgery. RESULTS: FET-PET/MRICR showed suspicious (para)sellar tracer uptake in all patients. In five patients FET-PET/MRICR was fully concordant with conventional MRI, and in one patient partially concordant. FET-PET/MRICR identified suggestive new foci in four other patients. Surgical re-exploration was performed in nine patients (aimed at total resection (6), debulking (2), diagnosis (1)), and one patient underwent radiation therapy. In 7 of 9 (78%) operated patients FET-PET/MRICR findings were confirmed intraoperatively, and in six (67%) also histologically. IGF-1 decreased significantly in eight patients (89%). All patients showed clinical improvement. Complete biochemical remission was achieved in three patients (50% of procedures in which total resection was anticipated feasible). Biochemistry improved in five and was unchanged in one patient. No permanent complications occurred. At six months, optimal outcome (preoperative intended goal achieved without permanent complications) was achieved in six (67%) patients and an intermediate outcome (goal not achieved, but no complications) in the other three patients. CONCLUSIONS: In patients with persisting acromegaly without a clear surgical target on MRI, FET-PET/MRICR is a new tracer to provide additional information to aid decision-making by the multidisciplinary pituitary team.

2.
Catheter Cardiovasc Interv ; 90(2): E31-E37, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28145609

RESUMO

BACKGROUND: Patients presenting with acute coronary syndrome (ACS) are at increased risk of complications after percutaneous coronary intervention with stent placement compared to patients with stable angina (SA) treated in an elective setting. The novel pro-healing COMBO stent is a bio-engineered drug eluting stent designed to promote vessel healing. Therefore, the stent may reduce this difference in clinical outcomes between elective and ACS-patients and prevent late stent thrombosis. METHODS AND RESULTS: The European, prospective, multicenter, 1000 all-comers patient REMEDEE registry evaluates clinical outcomes after COMBO stent placement in ACS- and elective patients. The primary endpoint at 12 months is target lesion failure (TLF), a composite of cardiac death, target-vessel myocardial infarction and target lesion revascularization. A total of 49.9% (n = 498) of patients presented with acute coronary syndrome. TLF was 7.1% in ACS patients, definite and probable stent thrombosis was observed in 0.5% of ACS patients and in all within 9 days post stenting. We found no significant difference in TLF between ACS and non-ACS patients and a low overall rate of TLF. CONCLUSIONS: The COMBO stent is a safe and efficient device for patients presenting with ACS. Low ST rate and only early stent thrombosis were observed. © 2017 Wiley Periodicals, Inc.


Assuntos
Síndrome Coronariana Aguda/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Quimioterapia Combinada , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/administração & dosagem , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
Am Heart J ; 168(5): 652-60, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25440792

RESUMO

BACKGROUND: Primary percutaneous coronary intervention (PCI) has considerably improved clinical outcomes in patients with ST-segment elevation myocardial infarction (STEMI) when compared with thrombolytic therapy. Prognosis after primary PCI might be further improved by decreasing stent-related complications such as stent thrombosis. The STENTYS self-apposing stent has been shown to be superior compared with balloon-expandable stents with regard to stent apposition. The current prospective randomized trial was designed to evaluate whether the superior stent apposition of the STENTYS stent results in clinical outcomes that are at least noninferior to a conventional balloon-expandable stent. METHODS: The APPOSITION V is a prospective, multicenter, international, single-blinded, randomized controlled trial in STEMI patients. Randomization will be performed in a 2:1 ratio between the self-apposing nitinol bare-metal STENTYS stent and the balloon-expandable bare-metal MULTI-LINK. The primary end point is defined as target vessel failure, which is a composite of cardiac death, target vessel-related recurrent myocardial infarction, or clinically driven target vessel revascularization, at 1-year follow-up. Baseline intravascular ultrasound and optical coherence tomography (OCT) substudies will be performed in 212 and 60 subjects, respectively, and a repeat angiography at 12 to 13 months will be performed in 105 subjects, including intravascular ultrasound and OCT (in the 60 OCT patients). This study is registered on ClinicalTrials.gov with number NCT01732341. CONCLUSION: APPOSITION V will be the first randomized trial powered on clinical end points that directly compares the STENTYS self-apposing stent with a conventional balloon-expandable stent in patients presenting with STEMI undergoing primary PCI.


Assuntos
Angioplastia Coronária com Balão/métodos , Infarto do Miocárdio/terapia , Desenho de Prótese , Stents , Ligas , Angiografia Coronária , Reestenose Coronária , Humanos , Intervenção Coronária Percutânea/métodos , Falha de Prótese , Recidiva , Método Simples-Cego , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
4.
J Hand Surg Am ; 35(7): 1126-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20610058

RESUMO

Ulnohumeral subluxation or dislocation is rare after open reduction and internal fixation of a bicolumnar fracture of the distal humerus. We report 3 patients in whom detachment of the origins of the lateral collateral ligament and common extensor muscle origins from the lateral epicondyle contributed to postoperative instability after open reduction and internal fixation of a fracture of the distal humerus. This may be due to either unrecognized ligament injury or iatrogenic injury during surgical dissection.


Assuntos
Lesões no Cotovelo , Fixação Interna de Fraturas/métodos , Fraturas do Úmero/cirurgia , Luxações Articulares/cirurgia , Instabilidade Articular/cirurgia , Articulação do Cotovelo/cirurgia , Feminino , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas Intra-Articulares/diagnóstico por imagem , Fraturas Intra-Articulares/cirurgia , Luxações Articulares/diagnóstico por imagem , Instabilidade Articular/diagnóstico por imagem , Ligamentos Articulares/lesões , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Radiografia , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica , Reoperação/métodos , Estudos de Amostragem , Resultado do Tratamento , Adulto Jovem
5.
Expert Rev Med Devices ; 15(7): 479-487, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29927344

RESUMO

INTRODUCTION: Coronary stent designs have been through extensive developments in the past few decades. Since the introduction of the self-apposing STENTYS stent, several theoretical advantages of its nitinol platform have been clinically evaluated. This paper reviews the current status, ongoing work, and future directions of this device. AREAS COVERED: The OPEN (STENTYS Coronary Bifurcation Stent System fOr the PErcutaNeous treatment of de novo lesions in native bifurcated coronary arteries) trials revealed high technical success rates of the STENTYS performance in bifurcation lesions. The Assessment of the Safety and Performance of the STENTYS self-expanding Coronary Stent in Acute Myocardial Infarction (APPOSITION) trials demonstrated the safety and feasibility of the device in patients with acute myocardial infarction. Optical coherence tomography showed better short-term strut apposition in patients treated with the STENTYS stent in APPOSITION IV. The clinical outcomes of the device in saphenous vein graft lesions and left main coronary artery disease are favorable. EXPERT COMMENTARY: Despite numerous theoretical advantages of the nitinol platform, superiority of the STENTYS self-apposing stent over currently available drug-eluting stents has not yet been proven. However, the ongoing registries evaluating the performance of the STENTYS Xposition will provide more insights in its clinical performance.


Assuntos
Doença da Artéria Coronariana/terapia , Stents/tendências , Ensaios Clínicos como Assunto , Humanos
6.
Expert Rev Med Devices ; 15(2): 157-165, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29284310

RESUMO

BACKGROUND: With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections using the novel Xposition delivery device as compared with the conventional delivery device. METHODS: A total of 38 patients who were treated with the self-apposing STENTYS stent and with OCT assessment at our center were retrospectively analysed. Twenty patients were treated using the Xposition- and 18 using the conventional delivery device. OCT was performed according to study protocol. Frames with poor quality were excluded. RESULTS: A total of 12(18%) dissections were detected, 7(20%) in the Xposition delivery device group, and 5(15%) in the conventional group (p = 1). Using the Xposition delivery device 4(33%) dissections were found proximally, using the conventional delivery device 3(25%) (p = ns). Mean longitudinal dissection length was 2.07 ± 1.80mm, 8(67%) appeared as flaps, 4(33%) as cavities. Morphometric parameters were comparable in both groups. CONCLUSIONS: Detailed OCT assessment of stent edge dissections was possible, which revealed no large differences using the Xposition delivery device as compared with conventional delivery device, however large studies are warranted.


Assuntos
Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea/instrumentação , Stents/efeitos adversos , Tomografia de Coerência Óptica , Lesões do Sistema Vascular/diagnóstico por imagem , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/etiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Lesões do Sistema Vascular/etiologia
7.
Congenit Heart Dis ; 13(6): 959-966, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30242971

RESUMO

OBJECTIVE: The association between secundum atrial septal defects (ASD) and asthma-like dyspnea with consequent long-term pulmonary inhalant use, is poorly understood in adult ASD patients. Airway hyperresponsiveness is suggested to be the underlying mechanism of cardiac asthma from mitral valve disease and ischemic cardiomyopathy. We hypothesized that airway hyperresponsiveness may also be found in adult ASD patients. Our aim was to study airway responsiveness in adult ASD patients before percutaneous closure and at short-and long-term postprocedural follow-up. METHODS: This prospective study included 31 ASD patients (65% female, mean age 49 ± 15y) who underwent spirometry and bronchoprovocation testing pre-and six-month postprocedurally, with additional bronchoprovocation at 2-year follow-up. Airway hyperresponsiveness was defined as ≥20% fall of forced expiratory volume in 1-second (FEV1 ) following <8.0 mg/mL of inhaled methacholine. RESULTS: Airway hyperresponsiveness was found in 19/30 patients (63%[95%CI 45%-81%]; post hoc statistical power = 89%). Asthma-like symptoms wheezing, chest tightness, and cough were more frequently reported in airway hyperresponsive patients. Airway responsiveness was not influenced by successful percutaneous ASD closure, corresponding to persistence of asthma-like symptoms postclosure. Regardless of airway responsiveness, postprocedural right-sided reverse remodeling significantly improved dyspnea and pulmonary function. CONCLUSIONS: This study is the first to report a high prevalence of airway hyperresponsiveness in a cohort of unrepaired adult ASD patients, and confirms the association between asthma-like symptoms and ASD in adults. Attention to symptoms and pulmonary function should be given during clinical follow-up of adult ASD patients, both before and long after repair.


Assuntos
Dispneia/etiologia , Comunicação Interatrial/complicações , Pulmão/fisiopatologia , Cateterismo Cardíaco , Dispneia/diagnóstico , Dispneia/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Fluxo Expiratório Forçado , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Espirometria
8.
Expert Rev Med Devices ; 14(5): 325-334, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28402204

RESUMO

INTRODUCTION: Treatment of coronary artery disease has made strides over the last decades. Development of drug eluting stents (DES), coated with a polymer layer and an anti-proliferative drug to reduce neointimal hyperplasia, has reduced the incidence of in-stent-restenosis relative to treatment with bare metal stents. Patients treated with first generation DES more likely suffer from (very) late events which can be cause by the permanent presence of a polymer. Therefore second generation DES with more biocompatible coatings, and third generation DES, with very thin struts coated with biodegradable polymers, were developed. Areas covered: The MiStent SES is one of these third generation DES and is designed to limit the duration of polymer exposure, optimize coronary vessel healing and more precisely and consistently control drug elution to improve safety and clinical outcomes. This review provides a detailed description of the technique behind the MiStent SES, and describes the pre-clinical and clinical trials conducted with this device to date. Expert commentary: Recent clinical trials have shown non-inferiority of very thin strut biodegradable polymer coated DES compared to durable polymer coated DES, whilst maintaining an excellent safety profile. Longer follow-up, to see the real potential benefits of these devices, is mandatory however.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Sirolimo/uso terapêutico , Animais , Ensaios Clínicos como Assunto , Implantes de Medicamento , Liberação Controlada de Fármacos , Humanos , Intervenção Coronária Percutânea/instrumentação , Polímeros/efeitos adversos , Pontuação de Propensão , Desenho de Prótese , Suínos , Fatores de Tempo , Resultado do Tratamento
9.
EuroIntervention ; 13(5): e572-e577, 2017 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28191875

RESUMO

AIMS: The APPOSITION III registry evaluated the feasibility and performance of the STENTYS self-apposing stent in an ST-segment elevation myocardial infarction (STEMI) population. This novel self-apposing stent device lowers stent strut malapposition rates and therefore carries the potential to prevent stent undersizing during primary percutaneous coronary intervention (PCI) in STEMI patients. To date, no long-term data are available using this device in the setting of STEMI. We aimed to evaluate the long-term clinical outcomes of the APPOSITION III registry. METHODS AND RESULTS: This was an international, prospective, multicentre post-marketing registry. The study population consisted of 965 STEMI patients. The primary endpoint, major adverse cardiac events (MACE), was defined as the composite of cardiac death, recurrent target vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularisation (CD-TLR). At two years, MACE occurred in 11.2%, cardiac death occurred in 2.3%, TV-MI occurred in 2.3% and CD-TLR in 9.2% of patients. The two-year definite stent thrombosis (ST) rate was 3.3%. Incremental event rates between one- and two-year follow-up were 1.0% for TV-MI, 1.8% for CD-TLR, and 0.5% for definite ST. Post-dilation resulted in significantly reduced CD-TLR and ST rates at 30-day landmark analyses. Results were equivalent between the BMS and PES STENTYS subgroups. CONCLUSIONS: This registry revealed low rates of adverse events at two-year follow-up, with an incremental ST rate as low as 0.5% in the second year, demonstrating that the self-apposing technique is feasible in STEMI patients on long-term follow-up while using post-dilatation.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Idoso , Angioplastia Coronária com Balão/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Resultado do Tratamento
10.
J Invasive Cardiol ; 29(8): 253-258, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28756418

RESUMO

OBJECTIVE: To investigate outcomes in patients with ST-segment elevation myocardial infarction (STEMI) after treatment with the Stentys self-apposing stent (Stentys SAS; Stentys S.A.) for bifurcation culprit lesions. BACKGROUND: The nitinol, self-expanding Stentys was initially developed as a dedicated bifurcation stent. The stent facilitates a provisional strategy by accommodating its diameter to both the proximal and distal reference diameters and offering an opportunity to "disconnect" the interconnectors, opening the stent toward the side branch. METHODS: The APPOSITION (a post-market registry to assess the Stentys self-expanding coronary stent in acute myocardial infarction) III study was a prospective, multicenter, international, observational study including STEMI patients undergoing primary percutaneous coronary intervention (PCI) with the Stentys SAS. Clinical endpoints were evaluated and stratified by bifurcation vs non-bifurcation culprit lesions. RESULTS: From 965 patients included, a total of 123 (13%) were documented as having a bifurcation lesion. Target-vessel revascularization (TVR) rates were higher in the bifurcation subgroup (16.4% vs 10.0%; P=.04). Although not statistically significant, other endpoints were numerically higher in the bifurcation subgroup: major adverse cardiac events (MACE; 12.7% vs 8.8%), myocardial infarction (MI; 3.4% vs 1.8%), and definite/probable stent thrombosis (ST; 5.8% vs 3.1%). However, when postdilation was performed, clinical endpoints were similar between bifurcation and non-bifurcation lesions: MACE (8.7% vs 8.4%), MI (1.2% vs 0.7%), and definite/probable ST (3.7% vs 2.4%). CONCLUSIONS: The use of the Stentys SAS was safe and feasible for the treatment of bifurcation lesions in the setting of primary PCI for STEMI treatment with acceptable 1-year cardiovascular event rates, which improved when postdilation was performed.


Assuntos
Ligas/uso terapêutico , Angioplastia Coronária com Balão/instrumentação , Vasos Coronários , Complicações Pós-Operatórias , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Stents Metálicos Autoexpansíveis , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Vigilância de Produtos Comercializados , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Stents Metálicos Autoexpansíveis/efeitos adversos , Stents Metálicos Autoexpansíveis/estatística & dados numéricos
11.
EuroIntervention ; 11(12): 1341-5, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25983027

RESUMO

AIMS: A novel balloon delivery system (BDS) for the self-apposing STENTYS sirolimus-eluting stent (SES) has been developed for highly precise longitudinal stent positioning and deployment. The aim of this first-in-man study is to report the quantitative coronary analysis (QCA) angiography and optical coherence tomography (OCT) results as well as the 30-day clinical outcomes of the STENTYS Xposition S SES. METHODS AND RESULTS: We included 25 patients (mean age 66.1±10.7 years) with stable coronary artery disease (24%) or acute coronary syndrome (including STEMI in 40%). The device was successfully placed at the intended site in all cases (100%), without procedural complications. Longitudinal geographic miss (entire lesion length [on QCA] not completely covered by the stent) was not observed. Pre-procedural MLD on QCA was 1.30±0.74 mm and post-procedural MLD was 2.74±0.44 mm, p<0.001 (acute gain 1.44±0.70 mm). OCT analyses showed a low percentage of malapposed stent struts directly post stent placement (2.4%), which further decreased after post-dilatation (0.6%, p=0.013), while mean stent area increased (from 9.7 mm2 to 10.5 mm2, p<0.001). At 30-day clinical follow-up, one (4%) major adverse cardiac event (MACE) was observed. One acute stent thrombosis (ST) occurred immediately post procedure in a STEMI patient which was related to inadequate medication therapy. CONCLUSIONS: This first-in-man study demonstrated that the use of the novel STENTYS Xposition S balloon delivery system is feasible with a high technical success rate without longitudinal geographical miss. Stent strut malapposition rate directly after STENTYS placement was low and improved further after post-dilatation.


Assuntos
Síndrome Coronariana Aguda/terapia , Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/etiologia , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
12.
Int J Cardiol ; 176(3): 776-81, 2014 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-25205481

RESUMO

BACKGROUND: Adult post-coarctectomy patients (CoA) demonstrate increased cardiovascular morbidity and mortality. The carotid intima-media thickness (CIMT), a marker for atherosclerosis, is increased in CoA. The aim was to evaluate the predictive value of CIMT for cardiovascular events. METHODS AND RESULTS: Consecutive CoA patients were prospectively studied during 10.1±0.7 years follow-up. At baseline and follow-up echocardiography, MRI imaging and CIMT imaging were performed, while cardiovascular events were registered. CIMT data were compared with controls. The composite endpoint included: myocardial infarction, cerebrovascular events (CVAs), and (sudden) cardiac death. 160 CoA patients were studied (median age 31.7 (18-74 years), 64% male). Events occurred in 11 patients (7%), five (3%) with myocardial infarction, four (2.5%) with an ischemic CVA and two (1%) died suddenly. An increased CIMT (≥0.8 mm) (HR=15.44, P=<0.001) was predictive for the occurrence of cardiovascular events. Baseline CIMT was increased in CoA compared to controls (0.64±0.12 mm vs 0.57±0.07 mm, P=0.005). CIMT progression rates were similar (0.0091±0.016 mm/year vs 0.0097±0.018 mm/year, P=0.84). Signs of atherosclerosis occurred significantly earlier in CoA patients. CONCLUSION: The contemporary cardiovascular event rate in CoA is 11% in 10 years. Atherosclerosis seems to appear earlier in CoA patients as compared to controls. CoA patients with a CIMT exceeding 0.8mm have a fifteen fold higher cardiovascular risk. CIMT seems to be a useful tool for cardiovascular risk assessment in CoA.


Assuntos
Coartação Aórtica/diagnóstico , Espessura Intima-Media Carotídea , Transtornos Cerebrovasculares/diagnóstico , Morte Súbita Cardíaca , Infarto do Miocárdio/diagnóstico , Adolescente , Adulto , Idoso , Coartação Aórtica/mortalidade , Espessura Intima-Media Carotídea/tendências , Transtornos Cerebrovasculares/mortalidade , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Valor Preditivo dos Testes , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA