Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Radiol Prot ; 39(2): 489-497, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30913548

RESUMO

Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no recent study quantifying overexposure of physicians during cardiac resynchronisation therapy (CRT) procedures compared to 'classical' implantation of pacemakers (PMs) or implantable cardioverter-defibrillators (ICDs). We aimed to measure and compare operator exposure to radiation during implantation of PM and ICD with or without CRT. The study population comprised all PMs and ICDs implanted in a large referral centre over a six months period. The endpoint was operator radiation exposure, assessed using a personal electronic dosimeter located on operator's chest. In total, 169 PM/ICD implantations were analysed, 19 of which included CRT. Compared with 'classical' implantation, cardiologist radiation exposure was 9-fold greater during CRT procedures (p < 0.001). Physician exposure was related to dose-area product (R2 = 0.21 during 'classical' implantations and R2 = 0.57 during CRT procedures). Our study shows that cardiologists' exposure to radiation during CRT implantation was 9-fold greater than during procedures without CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Desfibriladores Implantáveis , Exposição Ocupacional/análise , Marca-Passo Artificial , Implantação de Prótese , Exposição à Radiação/análise , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Estudos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Implantação de Prótese/efeitos adversos
2.
J Interv Card Electrophysiol ; 55(2): 233-237, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31177353

RESUMO

PURPOSE: Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no study comparing the level of exposure of physicians during different electrophysiology procedures. We aimed to measure and compare cardiologists' exposure to radiation during different electrophysiology procedures. METHODS: The study population comprised all electrophysiology procedures performed over a 6-month period in a large referral centre. The endpoint was operator radiation exposure, assessed using a personal electronic dosimeter located on the operator's left arm. RESULTS: In total, 150 electrophysiology procedures were analyzed. Compared with electrophysiology studies (reference category), physician radiation exposure was 3-fold greater during ablation of atrial fibrillation, 9-fold greater during ablation of atrioventricular nodal reentrant tachycardia (AVNRT)/atrioventricular reentrant tachycardia (AVNT), and 10-fold greater during ablation of atrial flutter (p < 0.001). Physician exposure was mainly related to X-ray time (R2 = 0.28). CONCLUSIONS: Our study showed significant differences in cardiologists' exposure to ionizing radiation depending on the type of electrophysiology procedure. Atrial flutter and AVNRT/AVNT ablations are the procedures in which operators are most exposed to ionizing radiation.


Assuntos
Cardiologistas , Técnicas Eletrofisiológicas Cardíacas , Exposição Ocupacional , Exposição à Radiação , França , Humanos , Radiometria , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA