Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Europace ; 25(3): 1077-1086, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36352513

RESUMO

Guidelines recommend patients undergoing a first pacemaker implant who have even mild left ventricular (LV) impairment should receive biventricular or conduction system pacing (CSP). There is no corresponding recommendation for patients who already have a pacemaker. We conducted a meta-analysis of randomized controlled trials (RCTs) and observational studies assessing device upgrades. The primary outcome was the echocardiographic change in LV ejection fraction (LVEF). Six RCTs (randomizing 161 patients) and 47 observational studies (2644 patients) assessing the efficacy of upgrade to biventricular pacing were eligible for analysis. Eight observational studies recruiting 217 patients of CSP upgrade were also eligible. Fourteen additional studies contributed data on complications (25 412 patients). Randomized controlled trials of biventricular pacing upgrade showed LVEF improvement of +8.4% from 35.5% and observational studies: +8.4% from 25.7%. Observational studies of left bundle branch area pacing upgrade showed +11.1% improvement from 39.0% and observational studies of His bundle pacing upgrade showed +12.7% improvement from 36.0%. New York Heart Association class decreased by -0.4, -0.8, -1.0, and -1.2, respectively. Randomized controlled trials of biventricular upgrade found improvement in Minnesota Heart Failure Score (-6.9 points) and peak oxygen uptake (+1.1 mL/kg/min). This was also seen in observational studies of biventricular upgrades (-19.67 points and +2.63 mL/kg/min, respectively). In studies of the biventricular upgrade, complication rates averaged 2% for pneumothorax, 1.4% for tamponade, and 3.7% for infection over 24 months of mean follow-up. Lead-related complications occurred in 3.3% of biventricular upgrades and 1.8% of CSP upgrades. Randomized controlled trials show significant physiological and symptomatic benefits of upgrading pacemakers to biventricular pacing. Observational studies show similar effects between biventricular pacing upgrade and CSP upgrade.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Disfunção Ventricular Esquerda , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Estimulação Cardíaca Artificial/efeitos adversos , Doença do Sistema de Condução Cardíaco/terapia , Sistema de Condução Cardíaco , Função Ventricular Esquerda , Volume Sistólico/fisiologia , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia
2.
J Cardiovasc Electrophysiol ; 31(5): 1155-1162, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32141635

RESUMO

BACKGROUND: The prognosis of patients with untreated cardiac implantable electronic device (CIED) infection is poor. Whether removal of all leads by a successful transvenous lead extraction (TLE) procedure changes the prognosis is unclear. OBJECTIVE: To identify predictors of mortality in patients with CIED infection despite successful TLE. METHODS: Retrospective single-center analysis of prospectively collected database from consecutive patients undergoing TLE at our center. Predictors for mortality were identified and a score predicting high mortality rate was calculated. RESULTS: A total of 371 consecutive patients underwent TLE, of whom 337 (90.8%) had complete hardware removal. Most were extracted due to infectious causes (81.3%). Approximately one-third (35%) died during a mean follow-up of 1056 ± 868 days. There was significantly higher mortality observed in the infectious group. Multivariate logistic regression models for infectious group only identified creatinine and albumin measurements as risk markers for 30 days mortality (odds ratio [OR], 1.68; 95% confidence interval [CI], 1.19-2.38; P = .003 and OR, 0.4; 95% CI, 0.16-0.97; P = .039, respectively). A risk score was created based on cutoff values of creatinine ≥2md/dL (1 point) and albumin ≤3.5 g/dL (1 point). A value of 2 points predicted a 50% chance of 30-day mortality and a 75% chance of 1-year mortality (P < .0001 for both). CONCLUSIONS: Creatinine and albumin can be used as a combined risk score to successfully identify patients at risk of death despite undergoing a successful TLE procedure for infectious reasons. This score could help decision making when contemplating on conservative antibiotic treatment vs TLE.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Falha de Prótese , Infecções Relacionadas à Prótese/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Creatinina/sangue , Bases de Dados Factuais , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/mortalidade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Albumina Sérica Humana/análise , Fatores de Tempo , Resultado do Tratamento
3.
Europace ; 21(6): 937-943, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31157389

RESUMO

AIMS: Lead perforation is a rare, well-known complication of cardiac implantable electronic device (CIED) implants, whose management is mostly not evidence-based. Main management strategies include conservative approach based on clinical and lead function follow-up vs. routine invasive lead revision approach. This study compared the complications of both strategies by composite endpoint, including recurrent perforation-related symptoms, recurrent pericardial effusion (PEf), lead dysfunction, and device infection during 12 month follow-up. METHODS AND RESULTS: Multicentre retrospective analysis, inquiring data from imaging studies, device interrogation, pericardiocentesis, and clinical charts of patients with suspected perforating leads between 2007 and 2014 in five hospitals. All cases were reviewed by electrophysiologist and defined as definite perforations by suggestive symptoms along with lead perforation on imaging, bloody PEf on pericardiocentesis shortly after implant, or right ventricular (RV) lead non-capture along with diaphragmatic stimulation upon bipolar pacing. Clinical outcomes associated with both management approaches were compared, with respect to the composite endpoint. The study included 48 definitive perforation cases: 22 managed conservatively and 26 via lead revision. Conservative management was associated with an increased composite endpoint compared with lead revision (8/22 vs. 1/26; P = 0.007). The dominant complication among the conservative cohort was appearance of cardiac tamponade during follow-up; 5/6 occurring in cases which presented with no or only mild PEf and were treated by antiplatelets/coagulants during or shortly after CIED implantation. CONCLUSION: A conservative management of CIED lead perforation is associated with increased complications compared with early lead revision. Lead revision may be the preferred management particularly in patients receiving antiplatelets/coagulants.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/terapia , Idoso , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/terapia , Remoção de Dispositivo , Feminino , Humanos , Masculino , Derrame Pericárdico/etiologia , Derrame Pericárdico/terapia , Pericardiocentese , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/terapia , Retratamento , Estudos Retrospectivos
4.
Curr Cardiol Rep ; 21(9): 106, 2019 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-31375934

RESUMO

Sudden cardiac death is one of the most important causes of death worldwide. Advancements in medical treatment, percutaneous interventions, and device therapy (ICD and CRTD) showed consistent reduction in mortality, mainly in survivors of SCD and in patients with ischemic cardiomyopathy and depressed left ventricular function. Patients with non-ischemic cardiomyopathies, mildly reduced LV function, and channelopathies have increased risk for SCD. Identifying the subgroup of these patients before they experience life-threatening or fatal events is essential to further improve outcomes. In this review, we aimed to summarize the current knowledge for risk stratification and primary prevention, to describe the gaps in evidence, and to discuss future directions for screening and treating patients at risk for SCD. PURPOSE OF REVIEW: The purpose of this review is to provide a comprehensive description of the etiologies of sudden cardiac death, risk stratification strategies, and to describe the current medical and interventional therapies. We aimed to discuss the current gaps in our knowledge of primary prevention of SCD and to review novel approaches and interventions. RECENT FINDINGS: The incidence of SCD has decreased in the last two decades due to improved pharmacological treatment and ICD implantation in SCD survivors and in patients with reduced left ventricular function and ischemic cardiomyopathy. The efficacy of ICD in patients with non-ischemic cardiomyopathy is challenged by new findings from the DANISH trial. Catheter ablation is new emerging strategy to prevent SCD in patients with scar relater or PVC-triggered ventricular arrhythmias. Despite the new treatments, SCD is still a major burden. ICD remains the cornerstone for patients with ischemic cardiomyopathy, whereas appropriate risk stratification of the patients with non-ischemic cardiomyopathy and channelopathies is needed to further improve outcomes. The future of ablation as the treatment and prevention of SCD remains to be studied.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Humanos , Prevenção Primária/tendências , Medição de Risco
5.
Isr Med Assoc J ; 21(1): 13-19, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30685899

RESUMO

BACKGROUND: Catheter ablation (CA) is a well-established therapeutic option for patients with recurrent symptomatic atrial fibrillation (AF). Data on gender-related differences are limited with regard to baseline characteristics and long-term success rates of catheter ablation for AF. METHODS: We analyzed a cohort of 251 consecutive patients who underwent a first catheter ablation for AF in our institute during the period 2008 through 2015. All patients were followed by regular annual clinic visits, electrocardiograms, periodic 24-48 hour Holter monitoring, and loop recorders. The primary endpoint was first recurrence of AF during 1 year of follow-up. RESULTS: The cohort comprised 26% women (n=65), who were older (62.1 ± 9.6 vs. 54.4 ± 11.3 years, P < 0.01) and had a higher proportion of diabetes mellitus (23.1 vs. 5.4%, P < 0.001) than male patients. No other significant differences were evident. At 1 year follow-up, the cumulative survival free of AF was significantly higher in women compared with men (83% vs. 66%, respectively, log rank P value = 0.021). Subgroup analysis showed an interaction between female and small indexed left atrial diameter (LADi < 23 mm/m2). CONCLUSIONS: Our findings suggest that women experience a significantly lower rate of AF recurrence post-CA compared with men. This gender-related advantage appears to be restricted to women without significant left atrial enlargement. It further implies that left atrial enlargement has a stronger negative impact on post-CA AF recurrence in females than in males. Due to the relatively small sample number of females further research is warranted to validate our conclusions.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Adulto , Idoso , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/mortalidade , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial/métodos , Feminino , Seguimentos , Átrios do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento
6.
Isr Med Assoc J ; 18(1): 18-22, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26964274

RESUMO

BACKGROUND: Transvenous lead extraction can lead to tricuspid valve damage. OBJECTIVES: To assess the incidence, risk factors and clinical outcome of tricuspid regurgitation (TR) following lead extraction. METHODS: We prospectively collected data on patients who underwent lead extraction at the Sheba Medical Center prior to laser use (i.e., before 2012). Echocardiography results before and following the procedure were used to confirm TR worsening, defined as an echocardiographic increase of at least one TR grade. Various clinical and echocardiographic parameters were analyzed as risk factors for TR. Clinical and echocardiographic follow-up was conducted to assess the clinical significance outcome of extraction-induced TR. RESULTS: Of 152 patients who underwent lead extraction without laser before 2012, 86 (56%) (192 electrodes) had echocardiography results before and within one week following the procedure. New or worsening TR was discovered in 13 patients (15%). Use of mechanical tools and younger age at extraction were found on multivariate analysis to be factors for TR development (P = 0.04 and P = 0.03 respectively). Average follow-up was 22.25 ± 21.34 months (range 8-93). There were no significant differences in the incidence of right-sided heart failure (50% vs. 23%, P = 0.192) or hospitalizations due to heart failure exacerbations (37.5% vs. 11%, P = 0.110). No patient required tricuspid valve repair or replacement. Death rates were similar in the TR and non-TR groups (20% vs. 33%). CONCLUSIONS: TR following lead extraction is not uncommon but does not seem to affect survival or outcomes such as need for valve surgery. Its long-term effects remain to be determined.


Assuntos
Remoção de Dispositivo/efeitos adversos , Eletrodos Implantados/efeitos adversos , Insuficiência Cardíaca/epidemiologia , Marca-Passo Artificial , Insuficiência da Valva Tricúspide/epidemiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/etiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Fatores de Risco , Insuficiência da Valva Tricúspide/etiologia
7.
J Cardiovasc Electrophysiol ; 25(11): 1188-95, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24891182

RESUMO

INTRODUCTION: Renal dysfunction is associated with increased morbi-mortality in heart failure patients. Data regarding functional and clinical efficacy of cardiac resynchronization therapy (CRT) in this population are limited. METHODS AND RESULTS: We aimed to evaluate the rate of functional response to CRT in patients with renal dysfunction and its association with long-term mortality. Our study included a total of 179 consecutive patients implanted between 2007 and 2010. The rate of functional response to CRT (defined by a composite score using New York Heart Association functional class, 6-minute walk test, and quality of life) was compared between patients with and without renal dysfunction (defined as eGFR < or ≥60 mL/min/1.73 m(2) ). Survival analysis estimates were constructed according to the Kaplan-Meier method, with results comparison using the log-rank test. During a median follow-up of 4.2 years, 73 patients (40%) died. Patients with low eGFR were older (72 ± 8 years vs. 64 ± 12 years; P < 0.001), and had higher prevalence of ischemic heart disease (75% vs. 53%; P = 0.003). Functional response rates did not differ significantly between patients with and without renal dysfunction (58% and 69%, respectively; P = 0.14). Despite overall higher mortality in patients with low eGFR (53.8% vs. 22.7%; P < 0.001), the presence of functional response at 1 year among patients with renal dysfunction was still independently associated with an improved long-term survival (HR = 0.49 [95%CI: 0.28-0.83]; P = 0.009). CONCLUSION: Functional response to CRT at 1 year does not differ significantly between patients with or without kidney disease, and is an independent predictor of improved long-term survival in patients with renal dysfunction.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Nefropatias/mortalidade , Nefropatias/terapia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/métodos , Estudos de Coortes , Feminino , Taxa de Filtração Glomerular/fisiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Nefropatias/fisiopatologia , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Fatores de Tempo , Resultado do Tratamento
8.
J Card Fail ; 20(6): 379-86, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24632340

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) has been shown to improve heart failure (HF) symptoms and survival. We hypothesized that a greater improvement in left-ventricular ejection fraction (LVEF) after CRT is associated with greater survival benefit. METHODS AND RESULTS: In 693 patients across 2 international centers, the improvement in LVEF after CRT was determined. Patients were grouped as non-/modest-, moderate-, or super-responders to CRT, defined as an absolute change in LVEF of ≤5%, 6-15%, and >15%, respectively. Changes in New York Heart Association (NYHA) functional class and left ventricular end-diastolic dimension (LVEDD) were assessed for each group. There were 395 non-/modest-, 186 moderate-, and 112 super-responders. Super-responders were more likely to be female and to have nonischemic cardiomyopathy, lower creatinine, and lower pulmonary artery systolic pressure than non-/modest- and moderate-responders. Super-responders were also more likely to have lower LVEF than non-/modest-responders. There was no difference in NYHA functional class, mitral regurgitation grade, or tricuspid regurgitation grade between groups. Improvement in NYHA functional class (-0.9 ± 0.9 vs -0.4 ± 0.8 [P < .001] and -0.6 ± 0.8 [P = .02]) and LVEDD (-8.7 ± 9.9 mm vs -0.5 ± 5.0 and -2.4 ± 5.8 mm [P < .001 for both]) was greatest in super-responders. Kaplan-Meier survival analysis revealed that super-responders achieved better survival compared with non-/modest- (P < .001) and moderate-responders (P = .049). CONCLUSIONS: Improvement in HF symptoms and survival after CRT is proportionate to the degree of improvement in LV systolic function. Super-response is more likely in women, those with nonischemic substrate, and those with lower pulmonary artery systolic pressure.


Assuntos
Terapia de Ressincronização Cardíaca/tendências , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Volume Sistólico/fisiologia , Idoso , Terapia de Ressincronização Cardíaca/mortalidade , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento
9.
Europace ; 16(2): 227-34, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24108231

RESUMO

AIMS: Strategically chosen ventricular tachycardia (VT)/ventricular fibrillation (VF) detection and therapy parameters aimed at reducing shock deliveries were proven effective in studies that utilized single manufacturer devices with a follow-up of up to 1 year. Whether these beneficiary effects can be generalized to additional manufacturers and be maintained for longer periods is to be determined. Our aim was to evaluate the durability and applicability of the programming of strategic implantable cardioverter-defibrillators (ICDs) of various manufacturers, which is aimed at reducing the shock delivery burden in primary prevention ICD recipients. METHODS AND RESULTS: A retrospective analysis of prospectively collected data of 300 ICD recipients of various manufacturers was conducted; 160 devices were strategically programmed to reduce shocks and 140 were not. The primary endpoint was the composite of death and appropriate shocks. Additional outcomes were inappropriate shocks, syncope events, and non-sustained VTs. At a median follow-up of 24 months, 19 patients died, 31 received appropriate shocks, and 41 received inappropriate shocks. Multivariate analysis showed that strategic programming dedicated to shock reduction was associated with a 64% risk reduction in the primary endpoint [hazard ratio (HR): 0.13-0.93; P = 0.03] and a 70% reduction in inappropriate shock deliveries (HR: 0.16-0.72; P = 0.01). Very few syncope events occurred (five patients, 1.6%), and there was no between-group difference in this outcome. CONCLUSION: Utilization of strategically chosen VT/VF detection and therapy parameters was found to be effective and safe in ICDs of various manufacturers at a median follow-up period of 2 years among primary prevention patients.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/métodos , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Síncope/etiologia , Síncope/prevenção & controle , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/complicações , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade
10.
Europace ; 16(4): 578-86, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23989534

RESUMO

AIMS: Absent left atrium (LA) mechanical contraction may occur following the modified Cox-maze operation, and was found to impose a potential risk for the occurrence of thrombo-embolic stroke. It is unknown whether certain morphological P-wave characteristics can surrogate absent LA mechanical activity. The aim of this study was to evaluate the morphological features of the P-waves on the surface electrocardiogram (ECG) of patients who underwent the maze operation and to relate them to the contractile profile of the LA. METHODS AND RESULTS: Electrocardiogram tracings of 150 consecutive patients that were in sustained sinus rhythm following the maze operation were evaluated. P-waves were scrutinized for morphology, duration, axis, and amplitude. Clinical, surgery-related, and echocardiographic data were collected and analysed. Forty-seven patients (31%) had no evidence of LA contraction at 3 months after surgery (baseline assessment) and on follow-up echocardiography. Multivariate analysis showed that a positive-only P-wave deflection at lead V1 (P = 0.03), a negative-only deflection at aVL, and a P-wave amplitude of ≤ 0.05 mV at the septal-anterior leads (P < 0.001 for both) were associated with absent LA mechanical contraction. In a secondary analysis, a risk score involving the above three parameters was developed for the prediction of stroke occurrence. Patients at the high-risk score group had a 30% survival freedom of stroke compared with 70% for patients at intermediate risk (P < 0.001). CONCLUSION: Absent LA mechanical contraction following the modified maze operation may be accompanied by a distinguished pattern of the P-waves on the surface ECG.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter , Criocirurgia , Eletrocardiografia , Contração Miocárdica , Potenciais de Ação , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Criocirurgia/efeitos adversos , Feminino , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Acidente Vascular Cerebral/prevenção & controle , Fatores de Tempo , Resultado do Tratamento
11.
Europace ; 16(8): 1175-80, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24554524

RESUMO

AIMS: Implantable cardioverter-defibrillators (ICDs) improve survival in certain high arrhythmic risk populations. However, there are sex differences regarding both the utilization and the benefit of these devices. Using a prospective national ICD registry, we aim to compare the indications for ICD implantation as well as outcomes in implanted women vs. men. METHODS AND RESULTS: All subjects implanted with an ICD or cardiac resynchronization therapy with a defibrillator (CRTD) in Israel between July 2010 and February 2013 were included. A total of 3544 subjects constructed the baseline cohort, of whom 615 (17%) were women. Women had the same age (64 years) and rate of secondary prevention indication (26%) as men. However, women were more likely than men to have significant heart failure symptoms (52 vs. 45%), QRS > 120 ms (41 vs. 36%), and a higher rate of non-ischaemic cardiomyopathy (54 vs. 21%, all P values <0.05). Using multivariate analysis, women were more likely to undergo CRTD implantation (odds ratio = 1.8, P < 0.01). Follow-up data were available for 1518 subjects with a mean follow-up of 12 months. During follow-up, there were no significant differences among genders in the rate of any single or the combined outcomes of appropriate device therapies, heart failure admissions, or death. First-year re-intervention rate was double among women (5.6 vs. 3.0%, P < 0.01). CONCLUSION: In real-world setting, women implanted with an ICD differ significantly from men in their baseline characteristics and in the use of CRTD devices. These, however, did not translate into outcome differences.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Disparidades nos Níveis de Saúde , Disparidades em Assistência à Saúde , Prevenção Primária/instrumentação , Prevenção Secundária/instrumentação , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Israel , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Retratamento , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento
12.
Europace ; 15(2): 266-72, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22952208

RESUMO

AIMS: The severity of tricuspid regurgitation (TR) is a predictor of outcome among heart failure patients. The interaction between cardiac resynchronization therapy (CRT) and TR has not been described. In this study, we examined the effect of pre-implant TR, and worsened TR post-implant, on response to CRT and overall survival. METHODS AND RESULTS: We included all patients with successfully implanted CRT systems between 2007 and 2010. Patients were divided into two groups pre-implant: (Gp 1) no-or-mild TR; and (Gp 2) moderate-or-severe TR. Post-implant, patients were divided into two groups: (Gp A) improved or stable TR; and (Gp B) worsened TR. The clinical and echocardiographic outcome of all patients was assessed. The study included 193 patients. Thirty-five subjects (18%) had moderate or severe TR pre-implant (Gp 2). Baseline echo parameters and 6 min walk distance were worse in Gp 2 compared with Gp 1 (mild or no TR). There was no significant difference in clinical response to CRT between the two groups. However, Gp 2 had a significantly lower echocardiographic response (35 vs. 60%, P = 0.01) and higher mortality over 3 years (OR = 6.70, 95% CI = 1.8-24.5, P = 0.004). Post-implant, 25 patients (13%) developed worsened TR (Gp B), not associated with deterioration in right ventricle function or elevation in pulmonary artery pressure. Worsened TR predicted a reduced clinical response to CRT (42 vs. 70%, P = 0.006), when compared with Gp A. CONCLUSIONS: The presence of baseline moderate or severe TR is associated with increased mortality but does not predict clinical or echocardiographic response to CRT. Patients with worsened TR following CRT are less likely to clinically respond to CRT. Pacing leads passing through the tricuspid valve may worsen TR. It is conceivable that avoidance of lead-induced TR by alternative implantation techniques could improve the response rate to CRT.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Insuficiência Cardíaca , Índice de Gravidade de Doença , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/terapia
13.
Pacing Clin Electrophysiol ; 36(11): 1342-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23713754

RESUMO

BACKGROUND: Contemporary implantable cardiac defibrillators (ICD) enable storage of multiple, preepisode R-R recordings in patients who suffered from ventricular tachyarrhythmia (VTA). Timely prediction of VTA, using heart rate variability (HRV) analysis techniques, may facilitate the implementation of preventive and therapeutic strategies. AIM: To evaluate the novel multipole method of the HRV analysis in prediction of imminent VTAs in ICD patients. METHODS: We screened patients from the Biotronik HAWAI Registry (Heart Rate Analysis with Automated ICDs). A total of 28 patients from the HAWAI registries (phase I and II), having medical records, who had experienced documented, verified VTA during the 2-year follow-up, were included in our analysis. HRV during preepisode recordings of 4,500 R-R intervals were analyzed using the Dyx parameter and compared to HRV of similar length recordings from the same patients that were not followed by arrhythmia. RESULTS: Our study population consisted mainly of men 25 of 28 (89%), average age of 64.8 ± 9.4 years, 92% with coronary artery disease. HRV during 64 preevent recordings (2.3 events per patient on average) was analyzed and compared with 60 control recordings. The multipole method of HRV analysis showed 50% sensitivity and 91.6% specificity for prediction of ventricular tachycardia/ventricular fibrillation in the study population, with 84.5% positive predictive value. No statistically significant correlation was found between various clinical parameters and the sensitivity of imminent VTA predetection in our patients. CONCLUSION: The multipole method of HRV analysis emerges as a highly specific, possible predictor of imminent VTA, providing an early warning allowing to prepare for an arrhythmic episode.


Assuntos
Desfibriladores Implantáveis , Diagnóstico por Computador/métodos , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco , Sensibilidade e Especificidade , Taquicardia Ventricular/prevenção & controle , Resultado do Tratamento
14.
Ann Noninvasive Electrocardiol ; 18(6): 571-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24147812

RESUMO

We describe the case of a 14-year-old girl with a history of syncopal episodes triggered by stress or exercise. Catecholaminergic polymorphic ventricular tachycardia was diagnosed with the aid of an implantable loop recorder. The genetic testing of the patient and her family revealed a de novo novel missense mutation (Ser4155Tyr) in the exon 90 of the ryanodine receptor gene. This mutation affects a highly conserved residue (S4155) and results to replacement of serine (S) with tyrosine (Y) leading to change in physical and chemical properties. The girl was treated with an implantable defibrillator, metoprolol and flecainide. Over 1 year of follow-up she had no recurrence of ventricular tachycardia.


Assuntos
Mutação de Sentido Incorreto/genética , Canal de Liberação de Cálcio do Receptor de Rianodina/genética , Síncope/genética , Taquicardia Ventricular/genética , Adolescente , Antiarrítmicos/uso terapêutico , Desfibriladores Implantáveis , Feminino , Flecainida/uso terapêutico , Seguimentos , Predisposição Genética para Doença/genética , Testes Genéticos/métodos , Humanos , Metoprolol/uso terapêutico , Síncope/complicações , Síncope/terapia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/terapia , Resultado do Tratamento
15.
Front Cardiovasc Med ; 10: 1192101, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37283572

RESUMO

Background: Evidence regarding the mortality benefit of implantable cardioverter defibrillator (ICD) non-ischemic dilated cardiomyopathy (NIDCM) is inconsistent. The most recent randomized study, the DANISH trial, did not find improved outcomes with ICD. However, based on previous studies and meta-analyses, current guidelines still highly recommend ICD implantation in NIDCM patients. The introduction of novel medications for heart failure improved the clinical outcome dramatically. We aimed in this study to evaluate the effect of Angiotensin Receptor-Neprilysin Inhibitors (ARNi) and sodium-glucose transport protein 2 inhibitors (SGLT2i) on the mortality benefit of ICD in NIDCM. Methods: We used a previous metanalysis algorithm and added an updated comprehensive literature search in PubMed for randomized control trials that examined the mortality benefit of ICD in NIDCM vs. optimal medical treatment. The primary outcome included death from any cause. We did a meta-regression analysis to search for a single independent factor affecting mortality. Using previous data, we evaluated the theoretical effect of ICD implementation on patients treated with SGLT2 inhibitors and ARNi. Results: No new articles were added to the results of the previous meta-analysis. 2,622 patients with NIDCM from 5 cohort studies published between 2002 and 2016 were included in the analysis. 50% of them underwent ICD implantation for primary prevention of sudden cardiac death, and 50% did not. ICD was associated with a significantly decreased risk for death from any cause compared to control (OR = 0.79, 95%CI: 0.66-0.95, p = 0.01, I2 = 0%). The theoretical addition of ARNi and the SGLT2 inhibitor dapagliflozin did not change the significant mortality effect of ICD (OR = 0.82, 95%CI: 0.7-0.9, p = 0.001, I2 = 0%) and (OR = 0.82, 95%CI: 0.7-0.9, p = 0.001, I2 = 0%). A meta-regression revealed no association between death from any cause and left bundle branch block (LBBB), use of amiodarone, use of angiotensin-converting enzyme inhibitors (ACEi) or angiotensin receptor blockers, year initiated enrollment, and the year ended enrollment (R2 = 0.0). Conclusion: In patients with NIDCM, the addition of ARNi and SGLT2i did not affect the mortality advantages of ICD for primary prevention. PROSPERO registry number: https://www.crd.york.ac.uk/prospero/, identifier: CRD42023403210.

16.
J Clin Med ; 12(21)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37959170

RESUMO

BACKGROUND: Atrial fibrillation (AF) is a common diagnosis in patients presenting to urgent care centers (UCCs), yet there is scant research regarding treatment in these centers. While some of these patients are managed within UCCs, some are referred for further care in an emergency department (ED). OBJECTIVES: We aimed to identify the rate of patients referred to an ED and define predictors for this outcome. We analyzed the rates of AF diagnosis and hospital referral over the years. Finally, we described trends in patient anticoagulation (AC) medication use. METHODS: This retrospective study included 5873 visits of patients over age 18 visiting the TEREM UCC network with a diagnosis of AF over 11 years. Multivariate analysis was used to identify predictors for ED referral. RESULTS: In a multivariate model, predictors of referral to an ED included vascular disease (OR 1.88 (95% CI 1.43-2.45), p < 0.001), evening or night shifts (OR 1.31 (95% CI 1.11-1.55), p < 0.001; OR 1.68 (95% CI 1.32-2.15), p < 0.001; respectively), previously diagnosed AF (OR 0.31 (95% CI 0.26-0.37), p < 0.001), prior treatment with AC (OR 0.56 (95% CI 0.46-0.67), p < 0.001), beta blockers (OR 0.63 (95% CI 0.52-0.76), p < 0.001), and antiarrhythmic medication (OR 0.58 (95% CI 0.48-0.69), p < 0.001). Visits diagnosed with AF increased over the years (p = 0.030), while referrals to an ED decreased over the years (p = 0.050). The rate of novel oral anticoagulant prescriptions increased over the years. CONCLUSIONS: The rate of referral to an ED from a UCC over the years is declining but remains high. Referrals may be predicted using simple clinical variables. This knowledge may help to reduce the burden of hospitalizations.

17.
Circulation ; 123(24): 2784-91, 2011 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-21632495

RESUMO

BACKGROUND: Women with congenital long-QT syndrome experience an increased risk for cardiac events after the onset of adolescence that is more pronounced among carriers of the LQT2 genotype. We hypothesized that the hormonal changes associated with menopause may affect clinical risk in this population. METHODS AND RESULTS: We used a repeated-events analysis to evaluate the risk for recurrent syncope during the menopause transition and postmenopausal periods (5 years before and after the age at onset of menopause, respectively) among 282 LQT1 (n=151) and LQT2 (n=131) women enrolled in the Long-QT Syndrome Registry. Multivariate analysis showed that the risk for recurrent syncope (n=150) among LQT2 women was significantly increased during both menopause transition (hazard ratio, 3.38; P=0.005) and the postmenopausal period (hazard ratio, 8.10; P<0.001) compared with the reproductive period. The risk increase was evident among women who did or did not receive estrogen therapy. In contrast, among LQT1 women, the onset of menopause was associated with a reduction in the risk for recurrent syncope (hazard ratio, 0.19; P=0.05; P=0.02 for genotype-by-menopause interaction). Only 22 women (8%) experienced aborted cardiac arrest or sudden cardiac death during follow-up. The frequency of aborted cardiac arrest/sudden cardiac death showed a similar genotype-specific association with the onset of menopause. CONCLUSIONS: The onset of menopause is associated with a significant increase in the risk of cardiac events (dominated by recurrent episodes of syncope) in LQT2 women, suggesting that careful follow-up and continued long-term therapy are warranted in this population.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Síndrome de Jervell-Lange Nielsen/mortalidade , Menopausa , Síndrome de Romano-Ward/mortalidade , Adulto , Distribuição por Idade , Canal de Potássio ERG1 , Terapia de Reposição de Estrogênios/estatística & dados numéricos , Canais de Potássio Éter-A-Go-Go/genética , Feminino , Seguimentos , Genótipo , Humanos , Síndrome de Jervell-Lange Nielsen/genética , Canal de Potássio KCNQ1/genética , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Síndrome de Romano-Ward/genética , Síncope/genética , Síncope/mortalidade
18.
Pacing Clin Electrophysiol ; 35(5): 586-91, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22360747

RESUMO

INTRODUCTION: Rate smoothing algorithms, while known to help prevent ventricular tachyarrhythmias in some patients, have been shown to result in underdetection of ventricular tachycardia (VT) due to interaction between bradycardia pacing and tachycardia detection parameters. A new algorithm named Bradycardia Tachycardia Response (BTR) has been developed in order to prevent rate smoothing-induced underdetection. The efficacy of BTR is not known. The aim of this study was to assess the effectiveness of BTR in preventing VT underdetection due to rate smoothing. METHODS AND RESULTS: Two ICD models (TELIGEN and VITALITY AVT, Boston Scientific, St. Paul, MN, USA) bearing identical rate smoothing algorithms were connected to a VT simulator. Devices were programmed similarly except for the BTR feature that exists in TELIGEN only. The detection performance of both devices was tested using varying combinations of AV delay, rate smoothing down, and upper rate limit and compared between the two models. VT underdetection (delay or nondetection) occurred during pacing in 62% of the VT episodes with VITALITY AVT. In TELIGEN, all simulated VT episodes were detected appropriately as soon as their rates exceeded the programmed VT detection rate. Detection tended to be affected by higher upper rate, longer AV delays, and more aggressive rate smoothing. CONCLUSION: The BTR algorithm effectively counteracts VT detection delay caused by the interaction of rate smoothing with VT detection parameters, thus enabling safe use of the rate smoothing feature.


Assuntos
Algoritmos , Bradicardia/diagnóstico , Bradicardia/terapia , Estimulação Cardíaca Artificial/métodos , Diagnóstico por Computador/métodos , Terapia Assistida por Computador/métodos , Simulação por Computador , Humanos , Modelos Cardiovasculares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia
19.
JACC Clin Electrophysiol ; 8(7): 908-912, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35750622

RESUMO

Epicardial access is becoming increasingly important for various cardiovascular interventions. Access to dry pericardial space can be challenging and is often associated with significant complications. A novel concealed-needle blunt-tip device is designed to capture the parietal pericardium layer and retract it into the distal end of the device, which houses a fixated concealed needle, in a bid to minimize the likelihood of lacerating the visceral layer of the pericardium. This prospective single-arm study evaluated the feasibility of use of this device in 11 human subjects with successful access attained in 91% (10 of 11) of cases without adverse events. (Pericardial Access With ViaOne Device; NCT05006157).


Assuntos
Pericárdio , Estudos Clínicos como Assunto , Estudos de Viabilidade , Humanos , Pericárdio/cirurgia , Estudos Prospectivos
20.
Front Cardiovasc Med ; 9: 1016657, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36312249

RESUMO

Background: The use of cardiovascular implantable electronic device (CIED) is steadily increasing, and complications include venous occlusion and fractured leads. Transvenous lead extraction (TLE) can facilitate the re-implantation of new leads. Aims: This study aims to explore predictors and complications of non-infectious TLE. Methods: This study involves a retrospective analysis and comparison of characteristics, complications, and outcomes of patients with and without occluded veins (OVs) undergoing TLE at our center. Results: In total, eighty-eight patients underwent TLE for non-infectious reasons. Indications for TLE were lead malfunction (62; 70.5%) and need for CIED upgrade (22; 25%). Fourteen patients referred due to lead malfunction had an OV observed during venography. The OV group (36 patients) were significantly older (65.7 ± 14.1 vs. 53.8 ± 15.9, p = 0.001) and had more comorbidities. Ejection fraction (EF) was significantly lower for the OV group (27.5 vs. 57.5%, p = 0.001) and had a longer lead dwelling time (3,226 ± 2,324 vs. 2,191 ± 1,355 days, p = 0.012). Major complications were exclusive for the OV group (5.5% vs. none, p = 0.17), and most minor complications occurred in the OV group as well (33.3 vs. 4.1%, p < 0.001). Laser sheath and mechanical tools for TLE were frequently used for OV as compared to the non-occluded group (94.4 vs. 73.5%, respectively, p = 0.012). Procedure success was higher in the non-occluded group compared to the OV group (98 vs. 83.3%, respectively, p = 0.047). Despite these results, periprocedural mortality was similar between groups. Conclusion: Among the TLE for non-infectious reasons, vein occlusion appears as a major predictor of complex TLE tool use, complications, and procedural success. Venography should be considered prior to non-infectious TLE to identify high-risk patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA