Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Paediatr Child Health ; 27(1): 12-14, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35273667

RESUMO

Neonatal hypoglycemia is a common, transitional metabolic state that may lead to poor neurodevelopmental outcomes if unrecognized or managed inadequately. Given its frequency of presentation and immense clinical significance, a myriad of clinical practice guidelines have been published outlining appropriate screening, diagnosis, and treatment principles-many endorsing the use of glucose point-of-care testing (POCT). Unfortunately, the well-intended 'march' toward POCT, with bedside glucose meters as screening devices in the NICU, has resulted in unintended consequences with critical implications: a lack of international traceability to the 'gold' standard glucose method by POCT devices, under-recognition of POCT limitations, and a reliance upon a technology primarily driven to detect hyperglycemia in the adult population as opposed to neonatal hypoglycemia. As providers continue to advocate for improved POCT, there must be robust communication between providers and the clinical laboratory in the selection, standardization, and interpretation of glucose POCT to ensure optimal neonatal glucose detection.

2.
Clin Chem ; 63(2): 585-592, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27974385

RESUMO

BACKGROUND: Clinical outcome studies for cardiac troponins (cTn) are expensive and difficult to design owing to variation in patients, in the assays, and in the incidence of different types of myocardial infarction (MI). To overcome these difficulties, simulation models were used to estimate the rate of misclassification error for MI and risk prediction resulting from assay bias and imprecision. METHODS: Finite mixture analysis of Abbott high-sensitivity cTnI (hs-cTnI) results at time 0 h in patients presenting early with acute coronary syndrome (ACS) symptoms to the emergency department (ED) [n = 145, Reducing the Time Interval for Identifying New Guideline (RING) study] allowed derivation of a simulation data set (n = 10000). hs-cTnI concentrations were modified by addition of bias or imprecision error. The percentage of all 10000 modified hs-cTnI results that were misclassified for MI at thresholds of 2, 5, 26.2, and 52 ng/L was determined by Monte Carlo simulation. Analyses were replicated with an all-comer emergency department (ED) population (n = 1137) ROMI (Optimum Troponin Cutoffs for ACS in the ED) study. RESULTS: In the RING study, simulation at 26.2-ng/L (99th percentile) and 52-ng/L thresholds were affected by both bias ±2 ng/L and imprecision (10%-20%) and had misclassification rates of 0.4% to 0.6%. Simulations at the 2-ng/L and 5-ng/L thresholds were only affected by bias. Misclassification rates at bias of ±1 ng/L were 10% for the 2-ng/L threshold, and 5% for the 5-ng/L threshold. CONCLUSIONS: Simulation models predicted that hs-cTnI results are seldom misclassified (<1% of patients) when interpretative thresholds are near or exceed the overall 99th percentile. However, simulation models also predicted that low hs-cTnI results, as recommended in guidelines, are prone to misclassification of 5%-10% of patients.


Assuntos
Simulação por Computador , Projetos de Pesquisa , Troponina I/análise , Síndrome Coronariana Aguda/diagnóstico , Viés , Humanos , Método de Monte Carlo , Infarto do Miocárdio/diagnóstico
3.
BMC Pediatr ; 17(1): 92, 2017 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-28356083

RESUMO

BACKGROUND: Neonatal hyperbilirubinemia has traditionally been screened by either total serum bilirubin or transcutaneous bilirubin. Whole blood bilirubin (TwB) by the GEM Premier 4000® blood gas analyzer (GEM) is a relatively new technology and it provides fast bilirubin results with a small sample volume and can measure co-oximetry and other analytes. Our clinical study was to evaluate the reliability of TwB measured by the GEM and identify analytical and clinical factors that may contribute to possible bias. METHODS: 440 consecutive healthy newborn samples that had plasma bilirubin ordered for neonatal hyperbilirubinemia screening were included. TwB was first measured using the GEM, after which the remainder of the blood was spun and plasma neonatal bilirubin was measured using the VITROS 5600® (VITROS). RESULTS: 62 samples (14%) were excluded from analysis due to failure in obtaining GEM results. Passing-Bablok regression suggested that the GEM results were negatively biased at low concentrations of bilirubin and positively biased at higher concentrations relative to the VITROS results (y = 1.43x-61.13). Bland-Altman plots showed an overall negative bias of the GEM bilirubin with a wide range of differences compared to VITROS. Both hemoglobin concentration and hemolysis affected the accuracy of the GEM results. Clinically, male infants had higher mean bilirubin levels, and infants delivered by caesarean section had lower hemoglobin levels. When comparing the number of results below the 40th percentile and above the 95th percentile cut-offs in the Bhutani nomogram which would trigger discharge or treatment, GEM bilirubin exhibited poor sensitivity and poor specificity in contrast to VITROS bilirubin. CONCLUSIONS: An imperfect correlation was observed between whole blood bilirubin measured on the GEM4000® and plasma bilirubin on the VITROS 5600®. The contributors to the observed differences between the two instruments were specimen hemolysis and the accuracy of hemoglobin measurements, the latter of which affects the calculation of plasma-equivalent bilirubin. Additionally, the lack of standardization of total bilirubin calibration particularly in newborn specimens, may also account for some of the disagreement in results.


Assuntos
Bilirrubina/sangue , Hiperbilirrubinemia Neonatal/diagnóstico , Triagem Neonatal/instrumentação , Biomarcadores/sangue , Gasometria/instrumentação , Feminino , Humanos , Hiperbilirrubinemia Neonatal/sangue , Recém-Nascido , Masculino , Triagem Neonatal/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Diabetes Sci Technol ; 16(5): 1114-1119, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-33719602

RESUMO

BACKGROUND: Our objective was to determine the effect of therapeutic concentrations of N-acetylcysteine, following intravenous infusion, on the measurement of blood glucose using a Roche Diagnostics glucose dehydrogenase-linked glucose meter compared to hospital laboratory methods. METHODS: N-acetylcysteine was added to aliquots of blood, with glucose promptly measured by the glucose meter, blood gas analyzer (glucose oxidase comparative method) and following centrifugation, plasma glucose measured with a hexokinase spectrophotometric comparative method. Glucose results were evaluated with linear regression and Bland Altman plots. RESULTS: In the presence of NAC, at concentrations greater than 5 mg/dL (0.31 mmol/L), positively biased glucose meter results were compared to the clinical laboratory results. Multivariate linear regression revealed that NAC-mediated meter results are influenced by NAC and glucose concentrations. CONCLUSIONS: The addition of therapeutic concentrations of NAC to blood produces statistically significant positive biases when measured with the glucose dehydrogenase linked glucose meter device.


Assuntos
Acetilcisteína , Glucose , Glicemia , Glucose 1-Desidrogenase , Testes Hematológicos , Humanos
5.
Int J Hyg Environ Health ; 244: 113990, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35714548

RESUMO

The Alberta Biomonitoring Program (ABP) was created in 2005 with the initial goal of establishing baseline levels of exposure to environmental chemicals in specific populations in the province of Alberta, Canada, and was later expanded to include multiple phases. The first two phases focused on evaluating exposure in pregnant women (Phase One, 2005) and children (Phase Two, 2004-2006) by analyzing residual serum specimens. Phase Three (2013-2016) employed active recruitment techniques to evaluate environmental exposures using a revised list of chemicals in paired serum pools from pregnant women and umbilical cord blood. These three phases of the program monitored a total of 226 chemicals in 285 pooled serum samples representing 31,529 individuals. Phase Four (2017-2020) of the ABP has taken a more targeted approach, focusing on the impact of the federal legalization of cannabis on the exposure of pregnant women in Alberta to cannabis, as well as tobacco and alcohol using residual prenatal screening serum specimens. Chemicals monitored in the first three phases include herbicides, neutral pesticides, metals, metalloids, and micronutrients, methylmercury, organochlorine pesticides, organophosphate pesticides, parabens, phthalate metabolites, perfluoroalkyl substances (PFAS), phenols, phytoestrogens, polybrominated compounds, polychlorinated biphenyls (PCBs), dioxins and furans, polycyclic aromatic hydrocarbons (PAHs), and tobacco biomarkers. Phase Four monitored six biomarkers of tobacco, alcohol, and cannabis. All serum samples were pooled. Mean concentrations and 95% confidence intervals (CIs) were calculated for the chemicals detected in ≥25% of the sample pools. cross the first three phases, the data from the ABP has provided baseline exposure levels for the chemicals in pregnant women, children, and newborns across the province. Comparison within and among the phases has highlighted differences in exposure levels with age, geography, seasonality, sample type, and time. The strategies employed throughout the program phases have been demonstrated to provide effective models for population biomonitoring.


Assuntos
Poluentes Ambientais , Praguicidas , Bifenilos Policlorados , Alberta , Monitoramento Biológico , Biomarcadores , Criança , Monitoramento Ambiental , Feminino , Humanos , Recém-Nascido , Exposição Materna , Gravidez
6.
Clin Chem ; 57(11): 1566-73, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21920914

RESUMO

BACKGROUND: Although measurement of whole-blood creatinine at the point of care offers rapid assessment of renal function, agreement of point-of-care (POC) results with central laboratory methods continues to be a concern. We assessed the influence of several potential interferents on POC whole-blood creatinine measurements. METHODS: We compared POC creatinine (Nova StatSensor) measurements with plasma enzymatic (Roche Modular) and isotope dilution mass spectrometry (IDMS) assays in 119 hospital inpatients. We assessed assay interference by hematocrit, pH, pO(2), total and direct bilirubin, creatine, prescribed drugs, diagnosis, red blood cell water fraction, and plasma water fraction. RESULTS: CVs for POC creatinine were 1.5- to 6-fold greater than those for plasma methods, in part due to meter-to-meter variation. Regressioncomparison of POC creatinine to IDMS results gave a standard error (S(y|x)) of 0.61 mg/dL (54 µmol/L), whereas regression of plasma enzymatic creatinine to IDMS was S(y|x) 0.16 mg/dL (14 µmol/L). By univariate analysis, bilirubin, creatine, drugs, pO(2), pH,plasma water fraction, and hematocrit were not found to contribute to method differences. However, multivariate analysis revealed that IDMS creatinine, red blood cell and plasma water fractions, and hematocrit explained 91.8% of variance in POC creatinine results. CONCLUSIONS: These data suggest that whole-blood POC creatinine measurements should be used with caution. Negative interferences observed with these measurements could erroneously suggest adequate renal function near the decision threshold, particularly if estimated glomerular filtration rate is determined. Disparity between whole-blood and plasma matrices partially explains the discordance between whole-blood and plasma creatinine methods.


Assuntos
Creatinina/sangue , Sistemas Automatizados de Assistência Junto ao Leito , Enzimas , Reações Falso-Negativas , Feminino , Taxa de Filtração Glomerular , Humanos , Técnicas de Diluição do Indicador , Indicadores e Reagentes , Pacientes Internados , Unidades de Terapia Intensiva , Nefropatias/sangue , Nefropatias/diagnóstico , Modelos Lineares , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Análise Multivariada , Serviço Hospitalar de Oncologia , Sistemas Automatizados de Assistência Junto ao Leito/normas , Padrões de Referência
7.
J Appl Lab Med ; 6(1): 210-218, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-33332539

RESUMO

BACKGROUND: Providing a positive patient experience for transgender individuals includes making the best care decisions and providing an inclusive care environment in which individuals are welcomed and respected. Over the past decades, introduction of electronic medical record (EMR) systems into healthcare has improved quality of care and patient outcomes through improved communications among care providers and patients and reduced medical errors. Promoting the highest standards of care for the transgender populations requires collecting and documenting detailed information about patient identity, including sex and gender information in both the EMR and laboratory information system (LIS). CONTENT: As EMR systems are beginning to incorporate sex and gender information to accommodate transgender and gender nonconforming patients, it is important for clinical laboratories to understand the importance and complexity of this endeavor. In this review, we highlight the current progress and gaps in EMR/LIS to capture relevant sex and gender information. SUMMARY: Many EMR and LIS systems have the capability to capture sexual orientation and gender identity (SOGI). Fully integrating SOGI into medical records can be challenging, but is very much needed to provide inclusive care for transgender individuals.


Assuntos
Serviços de Laboratório Clínico , Pessoas Transgênero , Atenção à Saúde , Registros Eletrônicos de Saúde , Feminino , Identidade de Gênero , Humanos , Masculino
8.
Hematol Oncol Stem Cell Ther ; 14(2): 110-113, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32502489

RESUMO

As part of the evaluation for chemotherapy readiness, urine specific gravity is measured to assess the patient's overall hydration status. Depending on the accuracy of the methods used, patients may be adversely affected by having their chemotherapy delayed or prematurely started. To evaluate the diagnostic accuracy of a new automated urine dipstick readout device (Clinitek), we tested 196 consecutive urine samples for urine specific gravity and compared them with the practical gold standard, a urine refractometer. We found a high correlation between both tools among clean urine samples, but a poor correlation among the pathological urine samples.


Assuntos
Neoplasias/urina , Urinálise/instrumentação , Adolescente , Antineoplásicos/uso terapêutico , Criança , Pré-Escolar , Humanos , Lactente , Neoplasias/tratamento farmacológico , Estudos Prospectivos , Refratometria/instrumentação , Gravidade Específica
9.
J Appl Lab Med ; 6(2): 451-462, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33463684

RESUMO

BACKGROUND: Patient surges beyond hospital capacity during the initial phase of the COVID-19 pandemic emphasized a need for clinical laboratories to prepare test processes to support future patient care. The objective of this study was to determine if current instrumentation in local hospital laboratories can accommodate the anticipated workload from COVID-19 infected patients in hospitals and a proposed field hospital in addition to testing for non-infected patients. METHODS: Simulation models predicted instrument throughput and turn-around-time for chemistry, ion-selective-electrode, and immunoassay tests using vendor-developed software with different workload scenarios. The expanded workload included tests from anticipated COVID patients in 2 local hospitals and a proposed field hospital with a COVID-specific test menu in addition to the pre-pandemic workload. RESULTS: Instrumentation throughput and turn-around time at each site was predicted. With additional COVID-patient beds in each hospital, the maximum throughput was approached with no impact on turnaround time. Addition of the field hospital workload led to significantly increased test turnaround times at each site. CONCLUSIONS: Simulation models depicted the analytic capacity and turn-around times for laboratory tests at each site and identified the laboratory best suited for field hospital laboratory support during the pandemic.


Assuntos
Teste para COVID-19/instrumentação , COVID-19/diagnóstico , Alocação de Recursos para a Atenção à Saúde/métodos , Laboratórios Hospitalares/organização & administração , Pandemias/estatística & dados numéricos , COVID-19/epidemiologia , COVID-19/virologia , Teste para COVID-19/estatística & dados numéricos , Teste para COVID-19/tendências , Serviços de Laboratório Clínico/organização & administração , Serviços de Laboratório Clínico/estatística & dados numéricos , Simulação por Computador , Conjuntos de Dados como Assunto , Previsões/métodos , Alocação de Recursos para a Atenção à Saúde/estatística & dados numéricos , Assistência Técnica ao Planejamento em Saúde , Número de Leitos em Hospital/estatística & dados numéricos , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Unidades de Terapia Intensiva/tendências , Laboratórios Hospitalares/provisão & distribuição , Laboratórios Hospitalares/tendências , Modelos Estatísticos , Kit de Reagentes para Diagnóstico/provisão & distribuição , Kit de Reagentes para Diagnóstico/tendências , SARS-CoV-2/isolamento & purificação , Saskatchewan/epidemiologia , Software , Fatores de Tempo , Carga de Trabalho/estatística & dados numéricos
10.
J Appl Lab Med ; 6(4): 953-961, 2021 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-33760097

RESUMO

BACKGROUND: Numerous studies have documented reduced access to patient care due to the COVID-19 pandemic, including access to diagnostic or screening tests, prescription medications, and treatment for an ongoing condition. In the context of clinical management for venous thromboembolism, this could result in suboptimal therapy with warfarin. We aimed to determine the impact of the pandemic on utilization of International Normalized Ratio (INR) testing and the percentage of high and low results. METHODS: INR data from 11 institutions were extracted to compare testing volume and the percentage of INR results ≥3.5 and ≤1.5 between a pre-pandemic period (January-June 2019, period 1) and a portion of the COVID-19 pandemic period (January-June 2020, period 2). The analysis was performed for inpatient and outpatient cohorts. RESULTS: Testing volumes showed relatively little change in January and February, followed by a significant decrease in March, April, and May, and then returned to baseline in June. Outpatient testing showed a larger percentage decrease in testing volume compared to inpatient testing. At 10 of the 11 study sites, we observed an increase in the percentage of abnormal high INR results as test volumes decreased, primarily among outpatients. CONCLUSION: The COVID-19 pandemic impacted INR testing among outpatients which may be attributable to several factors. Increased supratherapeutic INR results during the pandemic period when there was reduced laboratory utilization and access to care is concerning because of the risk of adverse bleeding events in this group of patients. This could be mitigated in the future by offering drive-through testing and/or widespread implementation of home INR monitoring.


Assuntos
Anticoagulantes/uso terapêutico , COVID-19/complicações , Coeficiente Internacional Normatizado/métodos , Assistência ao Paciente/estatística & dados numéricos , Assistência ao Paciente/normas , SARS-CoV-2/isolamento & purificação , Tromboembolia Venosa/tratamento farmacológico , Varfarina/uso terapêutico , COVID-19/virologia , Humanos , Tromboembolia Venosa/virologia
11.
Clin Chim Acta ; 519: 148-152, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33932408

RESUMO

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic caused a halt to in-person ambulatory care. We evaluated how the reduction in access to care affected HbA1c testing and patient HbA1c levels. METHODS: HbA1c data from 11 institutions were extracted to compare testing volume and the percentage of abnormal results between a pre-pandemic period (January-June 2019, period 1) and a portion of the COVID-19 pandemic period (Jan-June 2020, period 2). HbA1c results greater than 6.4% were categorized as abnormal. RESULTS: HbA1C testing volumes decreased in March, April and May by 23, 61 and 40% relative to the corresponding months in 2019. The percentage of abnormal results increased in April, May and June (25, 23, 9%). On average, we found that the frequency of abnormal results increased by 0.31% for every 1% decrease in testing volume (p < 0.0005). CONCLUSION: HbA1c testing volume for outpatients decreased by up to 70% during the early months of the pandemic. The decrease in testing was associated with an increase in abnormal HbA1c results.


Assuntos
COVID-19 , Pandemias , Humanos , Pacientes Ambulatoriais , Estudos Retrospectivos , SARS-CoV-2
12.
J Diabetes Sci Technol ; 14(3): 513-518, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31752535

RESUMO

BACKGROUND: The objective of this study was to estimate the combinations of total bias and total imprecision required for devices to meet the Food and Drug Administration (FDA) specifications using Monte Carlo simulation rather than collection and analysis of experimental data. METHODS: A model Gaussian distribution of true-glucose values was altered by adding bias and imprecision to create measured-glucose values affected by analytic error. The fraction of measured-glucose values that met the 2018 FDA criteria for blood glucose monitoring system (BGMS) or self-monitoring blood glucose (SMBG) devices was determined as a function of bias and imprecision. RESULTS: The BGMS model determined that a maximum total imprecision of 6% was required with no bias, and with a total bias of +10 mg/dL the total imprecision allowed was reduced to 5% to achieve the 95% FDA performance expectation: 95% of results ≥75 mg/dL within ±12% and 95% of results <75 mg/dL within ±12 mg/dL. The SMBG model determined that a maximum total imprecision of 6% was required at no bias, and with a total bias of +10 mg/dL the total imprecision allowed was reduced to 4% to achieve the 98% FDA expectation: 98% of results ±75 mg/dL within ±15% and 98% of results <75 mg/dL within ±15 mg/dL. CONCLUSIONS: The 2018 FDA guidance criteria require strict conditions for glucose meter clinical trials to achieve <10 mg/dL total bias and total imprecision of <5%. Total imprecision and bias values assessed in models in this study represent the cumulative imprecision and bias errors for the glucose meters, the reference method, and preanalytic processes.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/análise , Aprovação de Equipamentos , Testes Imediatos , United States Food and Drug Administration , Viés , Biomarcadores/sangue , Simulação por Computador , Desenho de Equipamento , Humanos , Método de Monte Carlo , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estados Unidos
13.
Arch Pathol Lab Med ; 144(10): 1204-1208, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-33002153

RESUMO

CONTEXT.­: Glycemic control requires accurate blood glucose testing. The extent of hematocrit interference is difficult to assess to assure quality patient care. OBJECTIVE.­: To predict the effect of patient hematocrit on the performance of a glucose meter and its corresponding impact on insulin-dosing error. DESIGN.­: Multilevel mixed regression was conducted to assess the extent that patient hematocrit influences Roche Accu-Chek Inform II glucose meters, using the Radiometer ABL 837 as a reference method collected during validation of 35 new meters. Regression coefficients of fixed effects for reference glucose, hematocrit, an interaction term, and random error were applied to 4 months of patient reference method results extracted from the laboratory information system. A hospital inpatient insulin dose algorithm was used to determine the frequency of insulin dose error between reference glucose and meter glucose results. RESULTS.­: Fixed effects regression for method and hematocrit predicted biases to glucose meter results that met the "95% within ±12%" for the US Food and Drug Administration goal, but combinations of fixed and random effects exceeded that target in emergency and hospital inpatient units. Insulin dose errors were predicted from the meter results. Twenty-eight percent of intensive care unit, 20.8% of hospital inpatient, and 17.7% of emergency department results were predicted to trigger a ±1 insulin dose error by fixed and random effects. CONCLUSIONS.­: The current extent of hematocrit interference on glucose meter performance is anticipated to cause insulin error by 1-dose category, which is likely associated with low patient risk.


Assuntos
Glicemia/análise , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Erros Médicos , Algoritmos , Hematócrito , Humanos , Medição de Risco , Estados Unidos
14.
J Diabetes Sci Technol ; 14(3): 519-525, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31694397

RESUMO

BACKGROUND: The Canadian Pediatric Society (CPS) has endorsed an algorithm for the screening and immediate management of babies at risk of neonatal hypoglycemia that provides time-dependent glucose concentration action thresholds. The objective of this study was to evaluate the impact of glucose analytic error (bias and imprecision) on the misclassification of glucose meter results from a neonatal intensive care unit (NICU) using the CPS guidelines. METHODS: A simulation dataset of true glucose values (N = 100 000) was derived by finite mixture model analysis of NICU glucose data (N = 23 749). Bias and imprecision were added to create measured glucose values. The percentages of measured glucose values that were misclassified at CPS action thresholds were determined by Monte Carlo simulation. RESULTS: Measurement biases ranging from -20 to +20 mg/dL combined with coefficients of variation 0% to 20% were evaluated to predict misclassification rates at 32, 36, and 47 mg/dL. The models demonstrated low risk of false normoglycemia-at 5% CV and +10 mg/dL bias: 0.8% to 5% misclassification at the 32 and 47 mg/dL thresholds due to bias. The models demonstrated risk of false hypoglycemia-at 5% CV and -10 mg/dL bias: 3% to 12.5% misclassification at 32 and 47 mg/dL thresholds due to both bias and imprecision. CONCLUSION: Using CPS action thresholds, the simulation model predicted the proportion of neonates at risk of inappropriate clinical action-both of omission or "failure to treat" and commission or "overtreatment" in response to NICU glucose meter results at specific bias and imprecision values.


Assuntos
Algoritmos , Análise Química do Sangue , Glicemia/metabolismo , Hipoglicemia/diagnóstico , Triagem Neonatal , Testes Imediatos , Viés , Biomarcadores/sangue , Análise Química do Sangue/instrumentação , Simulação por Computador , Humanos , Hipoglicemia/sangue , Recém-Nascido , Método de Monte Carlo , Triagem Neonatal/instrumentação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo
15.
Ann Clin Biochem ; 46(Pt 1): 65-72, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19103960

RESUMO

OBJECTIVE: The initial discovery of leptin (1994) has given rise to a substantial number of published studies. This study aimed at identifying the published data on the reference ranges of total, free and bound leptin concentration in the healthy prepubertal population. METHODS: A search was conducted on original English language studies published from 1994 to 2005 in the following databases: PubMed (n = 58), EMBASE (n = 4), Biological Abstracts (n = 2) and Science Finder Scholar (n = 66). A cited reference search was completed in Science Citation Index on studies with a leptin range. A meta-analysis was completed on included studies containing a dataset and a sample size for a leptin concentration range and/or mean+/-standard deviation for a healthy prepubertal population. Preanalytical and analytical variations were examined. Preanalytical variables included aspects such as fasting state and gender, while analytical variation comprised the type of leptin assay methodology. RESULTS: Twelve studies met the inclusion criteria. One study examined free leptin; 11 studies examined total concentration. No studies reported leptin reference ranges established by Clinical and Laboratory Standards Institute (CLSI) criteria, although four studies reported specific study leptin ranges. The methodology of enzyme-linked immunosorbent assay demonstrated a wider leptin range than radio immunoassay (0.56-36.35 vs. 1.01-12.21 ng/mL). Males had a significantly lower mean leptin concentration than females (P = 0.0006); obese children had a higher concentration than non-obese (P = 0.0001). CONCLUSION: No studies have established CLSI-based leptin reference ranges in prepubertal healthy children and there is a wide variation in the published leptin concentrations. These differences suggest that caution should be used in the interpretation and comparison between studies.


Assuntos
Leptina/análise , Criança , Pré-Escolar , Bases de Dados Factuais , Feminino , Humanos , Masculino , Valores de Referência
16.
Clin Biochem ; 70: 30-33, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31170380

RESUMO

OBJECTIVE: To develop a tool to assess the clinical accuracy of glucose meter performance using an insulin dosing protocol to assess the frequency and extent of error in insulin dose categories. METHODS: Retrospective comparison of 1815 glucose meter and central laboratory glucose results obtained from 1698 critically ill patients was conducted using the Parkes error grid, Surveillance error grid and an insulin dose error assessment grid with a sliding scale insulin dosing protocol used to manage critically ill patients. RESULTS: Parkes error grid and Surveillance error grid analyses indicated little risk conferred with the glucose meter results. Insulin dose error assessment grid complemented the aforementioned consensus error grids by determining quantifiable metrics, insulin dose category errors. Insulin dose error analysis indicated that 76.8% (1395/1815) would not have any change in insulin dose, 99.2% (1800/1815) within ±1 insulin dose category, 99.9% (1814/1815) within ±2 categories and 100% within ±3 insulin dose categories. CONCLUSIONS: Analysis with an insulin dose error grid provides information about the frequency and extent of insulin dose category errors with a specific insulin dosing protocol and describes potential clinical impact of glucose meter error.


Assuntos
Automonitorização da Glicemia/instrumentação , Glicemia/metabolismo , Insulina/administração & dosagem , Erros de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
17.
J Appl Lab Med ; 3(5): 764-774, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-31639752

RESUMO

BACKGROUND: Cardiac troponin I (cTnI) 99th percentile cutoffs, used in the diagnosis of acute myocardial infarction, are not standardized across cTnI assays. We compared 3 point-of-care (POC) and 1 central laboratory contemporary cTnI assays against the Abbott high-sensitivity (hs) cTnI to evaluate the analytical concordance and the feasibility of using a single cutoff value for all assays. METHODS: Fresh blood samples collected from 102 inpatients in the coronary care unit were measured on central laboratory instruments (Beckman Coulter DxI AccuTnI+3 TnI, Abbott Architect hs-TnI) and cTnI POC analyzers (Alere Triage Troponin I, Radiometer AQT90, Abbott i-STAT). Agreement and correlation between the contemporary cTnI assays and hs-cTnI assay were assessed using regression analysis. Proportional bias was assessed using Bland-Altman plots. Concordance between the contemporary cTnI and hs-cTnI assays was determined by diagnostic contingency tables at specific cutoffs. RESULTS: Most POC cTnI assays had excellent correlation with the Abbott hs-cTnI method (r 2 = 0.955-0.970) except for Alere Triage (r 2 = 0.617), while proportional bias is evident between all cTnI assays. Overall concordance between POC contemporary cTnI assays and hs-cTnI assay was 80% to 90% at their respective 99th percentile cutoffs. The concordance increased to 90% to 95% when a fixed cutoff of 0.03 to 0.05 ng/mL was used across the assays. CONCLUSIONS: This study demonstrates poor analytical concordance between cTnI assays at the 99th percentile and supports the notion of a single clinical decision limit for cTnI and consequently standardization of diagnostic protocols despite the analytical differences among these assays.


Assuntos
Biomarcadores/sangue , Laboratórios/normas , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito/estatística & dados numéricos , Troponina I/sangue , Troponina T/sangue , Bioensaio , Feminino , Humanos , Masculino , Triagem/estatística & dados numéricos
18.
Clin Chim Acta ; 393(2): 110-3, 2008 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-18407839

RESUMO

BACKGROUND: The objective of this study was to evaluate the utility of the Bayer microalbumin/creatinine urine reagent strip compared to established laboratory methods. METHODS: Random urine specimens from low and high risk pregnancy clinics as well as a random cohort from the community were analyzed for microalbumin and creatinine using both the reagent strip and the Roche Integra 700, according to manufacturers' specifications. Sensitivity and specificity were then calculated. RESULTS: For the pregnant cohorts the sensitivities ranged from 19% to 59%, and the range of specificities was 45.4% to 84.2%. Using the microalbumin/creatinine data from the community, the sensitivity and specificity of the strip were 52.4% and 97.6%, respectively. CONCLUSION: The poor sensitivity of the microalbumin/creatinine urine reagent strip to detect significant microalbuminuria will likely limit its usefulness as a screening tool.


Assuntos
Albuminúria/diagnóstico , Creatinina/urina , Kit de Reagentes para Diagnóstico , Feminino , Humanos , Gravidez , Sensibilidade e Especificidade
19.
Clin Biochem ; 53: 88-92, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29274316

RESUMO

BACKGROUND: Clinically significant variation has been reported within and between plasma and whole blood total bilirubin methods used to identify neonates for whom clinical intervention for hyperbilirubinemia may be required. OBJECTIVE: To evaluate total bilirubin measurements between the Radiometer whole blood co-oximeter and plasma bilirubin methods from Roche Diagnostics and Ortho Clinical Diagnostics using neonatal specimens. METHODS: Total bilirubin levels were analyzed by whole blood co-oximetry (Radiometer® ABL90). Specimens were centrifuged and plasma analyzed for total bilirubin with a diazo method (Roche Cobas® C-601) and a reflectance spectrophotometric BuBc dry film method (Ortho Clinical Diagnostics VITROS® 350). Results were evaluated by regression, Bland-Altman comparisons and t-tests. RESULTS: The patient correlation study yielded the following regression equations in µmol/L: a) Radiometer=1.03 Roche - 3.5µmol/L b) Radiometer=0.98 Ortho - 5.7µmol/L c) Roche=0.97 Ortho - 2.4µmol/L. The mean bias over the range of total bilirubin levels examined was -1.0µmol/L for the Radiometer versus the Roche (p≤0.305); -4.4µmol/L for the Radiometer versus Ortho (p≤0.005) and -4.4µmol/L for the Roche versus Ortho (p≤0.002). CONCLUSIONS: Whole blood total bilirubin measurement using the Radiometer ABL90 blood gas analyzer provides accurate and precise results compared to the Roche plasma diazo method. Compared to the reflectance spectrophotometric method, results are precise and had a small but statistically significant bias of -4.4µmol/L.


Assuntos
Bilirrubina/sangue , Hiperbilirrubinemia Neonatal/sangue , Oximetria , Feminino , Humanos , Recém-Nascido , Masculino , Oximetria/instrumentação , Oximetria/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA