RESUMO
When determining extracorporeal oxygen transfer (V ML O 2 ) during venovenous extracorporeal membrane oxygenation (VV ECMO) dissolved oxygen is often considered to play a subordinate role due to its poor solubility in blood plasma. This study was designed to assess the impact of dissolved oxygen on systemic oxygenation in patients with acute respiratory distress syndrome (ARDS) on VV ECMO support by differentiating between dissolved and hemoglobin-bound extracorporeal oxygen transfer. We calculated both extracorporeal oxygen transfer based on blood gas analysis using the measuring energy expenditure in extracorporeal lung support patients (MEEP) protocol and measured oxygen uptake by the native lung with indirect calorimetry. Over 20% of V ML O 2 and over 10% of overall oxygen uptake (VO 2 total ) were realized as dissolved oxygen. The transfer of dissolved oxygen mainly depended on ECMO blood flow (BF ML ). In patients with severely impaired lung function dissolved oxygen accounted for up to 28% of VO 2 total . A clinically relevant amount of oxygen is transferred as physically dissolved fraction, which therefore needs to be considered when determining membrane lung function, manage ECMO settings or guiding the weaning procedure.
Assuntos
Oxigenação por Membrana Extracorpórea , Oxigênio , Síndrome do Desconforto Respiratório , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Oxigênio/sangue , Oxigênio/metabolismo , Síndrome do Desconforto Respiratório/terapia , Pessoa de Meia-Idade , Masculino , Feminino , Adulto , Gasometria/métodos , Idoso , Consumo de Oxigênio/fisiologia , SolubilidadeRESUMO
Measurement of oxygen uptake (VO 2 ) and carbon dioxide removal (VCO 2 ) on membrane lungs (MLs) during extracorporeal membrane oxygenation (ECMO) provides potential for improved and safer therapy. Real-time monitoring of ML function and degradation, calculating caloric needs as well as cardiac output, and weaning algorithms are among the future possibilities. Our study compared the continuous measurement of the standalone Quantum Diagnostics System (QDS) with the published Measuring Energy Expenditure in ECMO patients (MEEP) approach, which calculates sequential VO 2 and VCO 2 values via blood gas analysis and a physiologic gas content model. Thirty-nine datasets were acquired during routine venovenous ECMO intensive care treatment and analyzed. VO 2 was clinically relevant underestimated via the blood-sided measurement of the QDS compared to the MEEP approach (mean difference -42.61 ml/min, limits of agreement [LoA] -2.49/-87.74 ml), which could be explained by the missing dissolved oxygen fraction of the QDS equation. Analysis of VCO 2 showed scattered values with wide limits of agreement (mean difference 54.95 ml/min, LoA 231.26/-121.40 ml/min) partly explainable by a calculation error of the QDS. We described potential confounders of gas-sided measurements in general which need further investigation and recommendations for enhanced devices.
Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Pulmão/metabolismo , Oxigênio , Dióxido de Carbono , Débito CardíacoRESUMO
BACKGROUND: Serum potassium concentrations are commonly between 3.5 and 5.0 mmol/l. Standardised protocols for potassium range and supplementation in the ICU are lacking. The purpose of this retrospective analysis of ICU patients was to investigate potassium concentrations, variability and supplementation, and their association with in-hospital mortality. METHODS: ICU patients ≥ 18 years, with ≥ 2 serum potassium values, treated at the Charité - Universitätsmedizin Berlin between 2006 and 2018 were eligible for inclusion. We categorised into groups of mean potassium concentrations: < 3.0, 3.0-3.5, > 3.5-4.0, > 4.0-4.5, > 4.5-5.0, > 5.0-5.5, > 5.5 mmol/l and potassium variability: 1st, 2nd and ≥ 3rd standard deviation (SD). We analysed the association between the particular groups and in-hospital mortality and performed binary logistic regression analysis. Survival curves were performed according to Kaplan-Meier and tested by Log-Rank. In a subanalysis, the association between potassium supplementation and in-hospital mortality was investigated. RESULTS: In 53,248 ICU patients with 1,337,742 potassium values, the lowest mortality (3.7%) was observed in patients with mean potassium concentrations between > 3.5 and 4.0 mmol/l and a low potassium variability within the 1st SD. Binary logistic regression confirmed these results. In a subanalysis of 22,406 ICU patients (ICU admission: 2013-2018), 12,892 (57.5%) received oral and/or intravenous potassium supplementation. Potassium supplementation was associated with an increase in in-hospital mortality in potassium categories from > 3.5 to 4.5 mmol/l and in the 1st, 2nd and ≥ 3rd SD (p < 0.001 each). CONCLUSIONS: ICU patients may benefit from a target range between 3.5 and 4.0 mmol/l and a minimal potassium variability. Clear potassium target ranges have to be determined. Criteria for widely applied potassium supplementation should be critically discussed. Trial registration German Clinical Trials Register, DRKS00016411. Retrospectively registered 11 January 2019, http://www.drks.de/DRKS00016411.