Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Anal Chem ; 96(21): 8365-8372, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38717986

RESUMO

Simultaneous sensitive and precise determination of multibiomarkers is of great significance for improving detection efficiency, reducing diagnosis and treatment expenses, and elevating survival rates. However, the development of simple and portable biosensors for simultaneous determination of multiplexed targets in biological fluids still faces challenges. Herein, a unique and versatile immobilization-free dual-target electrochemical biosensing platform, which combines distinguishable magnetic signal reporters with buoyancy-magnetism separation, was designed and constructed for simultaneous detection of carcinoembryonic (CEA) and α-fetoprotein (AFP) in intricate biological fluids. To construct such distinguishable magnetic signal reporters with signal transduction, amplification, and output, secondary antibodies of CEA and AFP were respectively functionalized on methylene blue (MB) and 6-(ferrocenyl)hexanethiol (FeC) modified Fe3O4@Au magnetic nanocomposites. Meanwhile, a multifunctional flotation probe with dual target recognition, capture, and isolation capability was prepared by conjugating primary antibodies (Ab1-CEA, Ab1-AFP) to hollow buoyant microspheres. The target antigens of CEA and AFP can trigger a flotation-mediated sandwich-type immunoreaction and capture a certain amount of the distinguishable magnetic signal reporter, which enables the conversion of the target CEA and AFP quantities to the signal of the potential-resolved MB and FeC. Thus, the MB and FeC currents of magnetically adsorbed distinguishable magnetic reporters can be used to determine the CEA and AFP targets simultaneously and precisely. Accordingly, the proposed strategy exhibited a delightful linear response for CEA and AFP in the range of 100 fg·mL-1-100 ng·mL-1 with detection limits of 33.34 and 17.02 fg·mL-1 (S/N = 3), respectively. Meanwhile, no significant nonspecific adsorption and cross-talk were observed. The biosensing platform has shown satisfactory performance in the determination of real clinical samples. More importantly, the proposed approach can be conveniently extended to universal detection just by simply substituting biorecognition events. Thus, this work opens up a new promising perspective for dual and even multiple targets and offers promising potential applications in clinical diagnosis.


Assuntos
Técnicas Biossensoriais , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , alfa-Fetoproteínas , alfa-Fetoproteínas/análise , alfa-Fetoproteínas/imunologia , Antígeno Carcinoembrionário/análise , Antígeno Carcinoembrionário/imunologia , Técnicas Biossensoriais/métodos , Humanos , Imunoensaio/métodos , Ouro/química , Limite de Detecção
2.
Analyst ; 149(3): 917-924, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38190154

RESUMO

Dopamine (DA) is an important biomarker related to parkinsonism, schizophrenia and renal disease. Traditional electrochemical sensors for DA were based on the direct electrochemical oxidation of DA. In this paper, we report a new sensing strategy using N,N'-di(trimethylaminoethyl)perylene diimide (TMPDI) as an electrochemical probe and K2S2O8 as a signal enhancer for DA detection between 0 and -0.7 V with the DPV technique. MoS2 nanoflowers prepared by the hydrothermal method were used as a nanocarrier to load TMPDI. The reduction current of TMPDI was found to show a stepwise and significant increase at -0.24 V with the increase of concentration of K2S2O8 due to the continuous cycle of TMPDI molecules' electrochemical reduction and chemical oxidation. The presence of DA caused a large decrease of the reduction current of TMPDI due to the synergistic interaction of the competitive consumption of DA for K2S2O8 and the blocking effect of polyDA adhering to the electrode surface. The decreased current exhibited a linear response for DA from 10 pM to 100 µM with a detection limit of 4.1 pM and the proposed sensor showed high selectivity and excellent feasibility in human urine/serum sample detection.


Assuntos
Técnicas Eletroquímicas , Imidas , Perileno , Humanos , Técnicas Eletroquímicas/métodos , Dopamina , Oxirredução , Eletrodos , Limite de Detecção
3.
Mikrochim Acta ; 191(7): 407, 2024 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898338

RESUMO

A smartphone-based electrochemical aptasensing platform was developed for the point-of-care testing (POCT) of carcinoembryonic antigen (CEA) based on the ferrocene (Fc) and PdPt@PCN-224 dual-signal labeled strategy. The prepared PdPt@PCN-224 nanocomposite showed a strong catalytic property for the reduction of H2O2. Phosphate group-labeled aptamer could capture PdPt@PCN-224 by Zr-O-P bonds to form PdPt@PCN-224-P-Apt. Therefore, a dual signal labeled probe was formed by the hybridization between Fc-DNA and PdPt@PCN-224-P-Apt. The presence of CEA forced PdPt@PCN-224-P-Apt to leave the electrode surface due to the specific affinity, leading to the decrease of the reduction current of H2O2. At the same time, the Fc-DNA strand changed to hairpin structure, which made Fc closer to the electrode and resulted in the increase of the oxidation current of Fc. Thus, CEA can be accurately determined through both signals: the decrease of H2O2 reduction current and the increase of Fc oxidation current, which could avoid the false positive signal. Under the optimal conditions, the prepared aptasensor exhibited a wide linear range from 1 pg·mL-1 to 100 ng·mL-1 and low detection limits of 0.98 pg·mL-1 and 0.27 pg·mL-1 with Fc and PdPt@PCN-224 as signal labels, respectively. The aptasensor developed in this study has successfully demonstrated its capability to detect CEA in real human serum samples. These findings suggest that the proposed sensing platform will hold great potential for clinical tumor diagnosis and monitoring.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Compostos Ferrosos , Peróxido de Hidrogênio , Limite de Detecção , Paládio , Testes Imediatos , Smartphone , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/análise , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Humanos , Técnicas Biossensoriais/métodos , Peróxido de Hidrogênio/química , Paládio/química , Compostos Ferrosos/química , Metalocenos/química , Platina/química
4.
Anal Chem ; 95(18): 7336-7343, 2023 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-37129510

RESUMO

Rapid and accurate detection of biomolecules is of vital importance for the diagnosis of disease and for performing timely treatments. The point-of-care analysis of cancer biomarkers in the blood with low cost and easy processing is still challenging. Herein, an advanced and robust strategy, which integrates the buoyant recognition probe with the magnetic reporter probe in one solution, was first proposed for immobilization-free electrochemical immunosensing. The tumor marker of alpha fetoprotein (AFP) can be captured immune-buoyantly, and then a multifunctional magnetic reporter probe in pseudo-homogeneous solution was further captured to fulfill a sandwich-type immunoreaction. The residual magnetic reporter probe can be firmly and efficiently attracted on a magnetic glassy carbon electrode to fulfill the conversion of the target AFP amount into the residual magnetic electrochemical signal indicator. As a result, the electrochemical signal of methylene blue can accurately reflect the original level of target antigen AFP concentration. By integrating buoyancy-driven quasi-homogenous biorecognition with magnetism-mediated amplification and signal output, the proposed immobilization-free electrochemical immunosensing strategy displayed a wide range of linear response (100 fg mL-1 to 10 ng mL-1), low detection limit (14.52 fg mL-1), and good reproducibility, selectivity, and stability. The designed strategy manifests remarkable advantages including assay simplicity, rapidness, and high sensitivity owing to the in-solution instead of on-electrode biorecognition that could accelerate and improve the biorecognition efficiency. To the best of our knowledge, this is the first cooperation of buoyancy-driven biorecognition with magnetism-mediated signal output in bioanalysis, which would be attractive for rapid clinic biomedical application. Thus, this work provides a fresh perspective for convenient and favorable immobilization-free electrochemical biosensing of universal biomolecules.


Assuntos
Técnicas Biossensoriais , alfa-Fetoproteínas , alfa-Fetoproteínas/análise , Técnicas Eletroquímicas , Reprodutibilidade dos Testes , Biomarcadores Tumorais/análise , Limite de Detecção , Imunoensaio , Ouro/química
5.
Analyst ; 148(17): 4037-4043, 2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37522239

RESUMO

As a prognostic biomarker for breast cancer, human epidermal growth factor receptor 2 (HER-2) is of crucial diagnostic value. Here, a label-free electrochemical aptasensor was established for the ultrasensitive detection of HER-2 using a modified electrode of Bi-Sb alloy materials (Bi-Sb AMs). The performance of the aptasensor was enhanced greatly due to the introduction of Bi-Sb alloy materials (Bi-Sb AMs) with high conductivity. Furthermore, by integrating the aptasensor with the Sensit Smart U-disk electrochemical analyzer, the point-of-care testing (POCT) for HER-2 was realized. Under the optimal experimental parameters, the POCT analyzer showed a wide linear response from 0.01 pg mL-1 to 100 ng mL-1, with a low detection limit (LOD) of 5.96 fg mL-1 for the detection of HER-2. The presented POCT analyzer exhibited good specificity, stability, and reproducibility. Benefiting from the simple operation and rapid testing, the developed analyzer will have potential application in the prognostic diagnosis and treatment of breast cancer.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Humanos , Técnicas Eletroquímicas , Ligas , Reprodutibilidade dos Testes , Limite de Detecção , Ouro
6.
Mikrochim Acta ; 191(1): 21, 2023 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-38091113

RESUMO

This study aimed to develop a quenching-type electrochemiluminescence (ECL) immunosensor for human epidermal growth factor receptor (Her-2) detection. Firstly, Pd/NiFeOx nanoflowers decorated by in situ formation of gold nanoparticles (Au NPs) and 2D Ti3C2 MXene nanosheets were synthesized (AuPd/NiFeOx/Ti3C2) as carriers to load luminol and primary antibodies. Impressively, AuPd/NiFeOx/Ti3C2 with excellent peroxidase-like activity could accelerate the decomposition of the coreactant H2O2 generating more reactive oxygen species (ROSs) under the working potential from 0 to 0.8 V, resulting in highly efficient ECL emission at 435-nm wavelengths. The introduction of tungsten-based polyoxometalate nanoclusters (W-POM NCs) which exhibit remarkable ROSs-scavenging activity as secondary antibody labels could improve the sensitivity of immunosensors. The ZnO nanoflowers were employed to encapsulate minute-sized W-POM NCs, and polydopamine was self-polymerized on the surface of Zn(W-POM)O to anchor secondary antibodies. The mechanism of the quenching strategy was explored and it was found that W-POM NCs could consume ROSs by the redox reaction of W5+ resulting in W6+. The proposed ECL immunosensor displayed a wide linear response range of 0.1 pg·mL-1 to 50 ng·mL-1, and a low detection limit of 0.036 pg mL-1 (S/N = 3). The recoveries ranged from 93.9 to 99.4%, and the relative standard deviation (RSD) was lower than 10%. This finding is promising for the design of detecting new protein biomarkers.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Humanos , Luminol , Espécies Reativas de Oxigênio , Técnicas Biossensoriais/métodos , Tungstênio , Ouro , Peróxido de Hidrogênio , Medições Luminescentes/métodos , Imunoensaio
7.
Anal Chem ; 94(37): 12845-12851, 2022 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-36067524

RESUMO

Ratiometric electrochemiluminescence (ECL) sensors can efficiently remove environmental interference to attain precise detection. Nonetheless, two eligible luminophores or coreactants were usually needed, increasing the complexity and restricting their practical application. In this study, a single luminophore of luminol with a single coreactant of H2O2 was employed to construct a dual-potential ratiometric ECL sensor for the detection of carcinoembryonic antigen (CEA). The produced palladium nanoclusters (Pd NCs) employing a DNA duplex as a template could not only stimulate luminol to produce cathodic ECL (Icathodic) but also quench its anodic ECL (Ianodic). During the detection process, CEA could damage the double-stranded structure and reduce the Pd NCs' amount, triggering a significant decrease in the ratio of Icathodic to Ianodic (Icathodic/Ianodic) and thereby achieving sensitive CEA's detection. Furthermore, the Icathodic/Ianodic was independent of the H2O2 concentration, which avoided a prejudicial effect from H2O2 decomposition and considerably enhanced the detection's reliability. The developed ratiometric ECL sensor demonstrated a sensitive detection toward CEA with a wide linear range from 100 ag/mL to 10 ng/mL and a detection limit of 87.1 ag/mL (S/N = 3). In conclusion, this study offers a new idea for constructing ratiometric ECL sensors based on a single luminophore and technical support for cancer's early diagnosis.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Antígeno Carcinoembrionário , DNA/química , Técnicas Eletroquímicas , Peróxido de Hidrogênio , Limite de Detecção , Medições Luminescentes , Luminol/química , Nanopartículas Metálicas/química , Paládio/química , Reprodutibilidade dos Testes
8.
Analyst ; 146(11): 3679-3685, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955434

RESUMO

In the electrochemiluminescence (ECL) field, most reported luminophores were focused on high-triggering potential and short wavelength, which was adverse for the ECL theory study and application at low potentials. Perylene diimide derivatives could emit near-infrared (NIR) ECL at low-triggering potential; however, they are always highly aggregated into a microrod structure and stacked together, which largely limited their application in biological fields such as bio-sensing and bio-imaging. To overcome these obstacles, we designed a novel perylene diimide molecule, namely N,N'-dicaproate sodium-3,4,9,10-perylenedicarboximide (PDI-COONa). This molecule self-assembled into a two-dimensional network nanostructure, which largely decreased the aggregation degree of PDI molecules and provided solid bases for designing lowly-aggregated PDI molecules. Also, the formed nanoluminophore produced strong emission at -0.26 V with an NIR wavelength 700 nm, which should be due to the excited J-type PDI-COO- dimers. Moreover, this network nanoluminophore well-dispersed on graphene oxide (GO) as an ECL nanomaterial to label secondary antibodies and fabricate a sandwiched immunosensor for alpha-fetoprotein (AFP) detection between 0 and -0.6 V. This immunosensor showed a wider linear response for AFP ranging from 0.1 fg mL-1 to 1 µg mL-1 with a low detection limit 0.0353 fg mL-1 compared with other immunosensors based on PDI microrod-modified GO ECL materials. The fabricated immunosensor also showed good feasibility in human serum samples.


Assuntos
Técnicas Biossensoriais , Perileno , Técnicas Eletroquímicas , Humanos , Imunoensaio , Limite de Detecção , Medições Luminescentes
9.
Analyst ; 146(8): 2705-2711, 2021 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-33751013

RESUMO

A novel ratiometric electrochemical biosensing strategy based on T7 exonuclease (T7 Exo)-assisted homogenous target recycling coupling hairpin assembly triggered dual-signal output was proposed for the accurate and sensitive detection of microRNA-141 (miRNA-141). Concretely, in the presence of target miRNA, abundant signal transduction probes were released via the T7 Exo-assisted homogenous target recycling amplification, which could be captured by the specially designed ferrocene-labeled hairpin probe (Fc-H1) on -electrode interface and triggered the nonenzymatic catalytic hairpin assembly (Fc-H1 + MB-H2) to realize the cascade signal amplification and dual-signal output. Through such a conformational change process, the electrochemical signal of Fc (IFc) and MB (IMB) is proportionally and substantially decreased and increased. Therefore, the signal ratio of IMB/IFc can be employed to accurately reflect the true level of original miRNA. Benefiting from the efficient integration of the T7 Exo-assisted target recycle, nonenzymatic hairpin assembly and dual-signal output mode, the proposed sensor could realize the amplified detection of miRNA-141 effectively with a wide detection range from 1 fM to 100 pM, and a detection limit of 200 aM. Furthermore, it exhibits outstanding sequence specificity to discriminate mismatched RNA, acceptable reproducibility and feasibility for real sample. This strategy effectively integrated the advantages of multiple amplification and ratiometric output modes, which could provide an accurate and efficient method in biosensing and clinical diagnosis.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Técnicas Eletroquímicas , Exodesoxirribonucleases , Limite de Detecção , MicroRNAs/genética , Reprodutibilidade dos Testes
10.
Mikrochim Acta ; 189(1): 17, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-34873664

RESUMO

As well known, the electrochemiluminescence (ECL) of tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)32+) heavily relies on highly positive or negative triggered voltage, prejudicing the detection toward the bio-molecules. In this work, Ru(bpy)32+ could generate enhanced and stable ECL at a low potential of 0.05 V (vs. Ag/AgCl) on graphene-PtPd hybrid, attributing to its excellent electrocatalysis from the synergistic effect between Pt and Pd. The obtained low-potential-driven ECL could be quenched by MoS2 nanoflowers. Based on the quenching effect, a sandwich "signal-off" ECL immunosensor was fabricated to sensitively detect carcinoembryonic antigen (CEA). A linear calibration curve from 1 fg mL-1 to 1 ng mL-1 was obtained along with a low detection limit of 0.54 fg mL-1 (S/N = 3) under optimal conditions. The sensor showed satisfactory specificity, stability, and reproducibility and was successfully applied to determine CEA in actual samples. The recoveries ranged from 98.80 to 100.23%, and the relative standard deviation (RSD) was lower than 5%. Above all, this work explored new materials in low-potential-driven ECL system and provided a reliable sensing strategy for clinical applications.


Assuntos
Antígeno Carcinoembrionário/sangue , Técnicas Eletroquímicas/métodos , Imunoensaio/métodos , Substâncias Luminescentes/química , Nanocompostos/química , Compostos Organometálicos/química , Anticorpos Imobilizados/imunologia , Antígeno Carcinoembrionário/imunologia , Dissulfetos/química , Grafite/química , Humanos , Limite de Detecção , Molibdênio/química , Paládio/química , Platina/química , Reprodutibilidade dos Testes
11.
Analyst ; 145(10): 3605-3611, 2020 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-32266898

RESUMO

A sensitive and enzyme-free electrochemical aptasensor was constructed for the sensing of 8-hydroxy-2'-deoxyguanosine (8-OH-dG). In the process of constructing the aptasensor, triple signal amplification strategies were introduced to enhance the sensitivity. First, every aptamer/pDNA complex immobilized on magnetic beads could release three kinds of pDNAs when 8-OH-dG was introduced, which caused three-fold magnification of the target. Second, the released three kinds of pDNAs initiated catalyzed hairpin assembly between two hairpin DNAs (HP1 and HP2) on a gold electrode. Meanwhile, the three kinds of pDNAs were released again by a strand displacement reaction to obtain the next catalyzed hairpin assembly. Third, the emerging toehold of HP2 further induced a hybridization chain reaction (HCR) between two hairpin DNAs (HP3 and HP4), forming a long double-stranded DNA concatemer on the surface of the electrode. Finally, [Ru(NH3)6]3+, an electroactive cation, was adsorbed onto the long dsDNA concatemer by electrostatic interactions and consequently, an electrochemical signal was generated. Under this triple signal amplification, a low detection limit down to 24.34 fM has been obtained for 8-OH-dG determination, which is superior to those of most previously reported methods.


Assuntos
8-Hidroxi-2'-Desoxiguanosina/análise , Biocatálise , Técnicas Biossensoriais/métodos , DNA/química , DNA/genética , Sequências Repetidas Invertidas , 8-Hidroxi-2'-Desoxiguanosina/química , 8-Hidroxi-2'-Desoxiguanosina/urina , Aptâmeros de Nucleotídeos/metabolismo , Eletroquímica , Humanos , Hibridização de Ácido Nucleico
12.
Biochemistry ; 56(32): 4235-4243, 2017 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-28714309

RESUMO

Blebbistatin is a potent and specific inhibitor of the motor functions of class II myosins, including striated muscle myosin and nonmuscle myosin-2 (NM2). However, the blebbistatin inhibition of NM2c has not been assessed and remains controversial with respect to its efficacy with smooth muscle myosin (SmM), which is highly homologous to NM2. To clarify these issues, we analyzed the effects of blebbistatin on the motor activities of recombinant SmM and three NM2s (NM2a, -2b, and -2c). We found that blebbistatin potently inhibits the actin-activated ATPase activities of SmM and NM2s with following IC50 values: 6.47 µM for SmM, 3.58 µM for NM2a, 2.30 µM for NM2b, and 1.57 µM for NM2c. To identify the blebbistatin-resistant myosin-2 mutant, we performed mutagenesis analysis of the conserved residues in the blebbistatin-binding site of SmM and NM2s. We found that the A456F mutation renders SmM and NM2s resistant to blebbistatin without greatly altering their motor activities or phosphorylation-dependent regulation, making A456F a useful mutant for investigating the cellular function of NM2s.


Assuntos
Proteínas Aviárias/antagonistas & inibidores , Proteínas Aviárias/química , Compostos Heterocíclicos de 4 ou mais Anéis/química , Miosina não Muscular Tipo IIB/antagonistas & inibidores , Miosina não Muscular Tipo IIB/química , Miosinas de Músculo Liso/antagonistas & inibidores , Miosinas de Músculo Liso/química , Substituição de Aminoácidos , Animais , Proteínas Aviárias/genética , Proteínas Aviárias/metabolismo , Galinhas , Humanos , Camundongos , Mutação de Sentido Incorreto , Miosina não Muscular Tipo IIB/genética , Miosina não Muscular Tipo IIB/metabolismo , Miosinas de Músculo Liso/genética , Miosinas de Músculo Liso/metabolismo
13.
Anal Chem ; 86(16): 8275-80, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-25069087

RESUMO

A dual quinone tagging strategy is designed for quantitation of cysteine-containing peptide (CCP) with MALDI-TOF mass spectrometry. The quinone compounds can rapidly and specifically bind to the thiol group of cysteine residues by a Michael addition reaction, which is used to identify both CCP and the number of cysteine residues in CCP through the direct observation of untagged and tagged products. After reduced with DL-dithiothreitol, the intramolecular disulfide bond can also be identified. Using benzoquinone (BQ) and methyl-p-benzoquinone (MBQ) as dual tags and a peptide with an amino acid sequence of SSDQFRPDDCT (C-pep1) as a model target, respectively, the quantitation strategy is performed through the intensity ratio of MBQ-tagged C-pep1 to BQ-tagged C-pep1 as the internal standard. The logarithm value of the intensity ratio is proportional to C-pep1 concentration in a range from 5.0 to 5000 nM. The limit of detection is as low as 2.0 nM. The proposed methodology provides a novel tool for rapid characterization, identification, and quantitation of biomolecules containing thiol reactive sites and has a promising application in the large-scale detection and analysis of cysteine-containing biomolecules.


Assuntos
Cisteína/análise , Peptídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sequência de Aminoácidos , Benzoquinonas/química , Limite de Detecção , Compostos de Sulfidrila/análise
14.
Lab Chip ; 24(2): 367-374, 2024 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-38126214

RESUMO

Carcinoembryonic antigen (CEA) is a biomarker of high expression in cancer cells. Highly sensitive and selective detection of CEA holds significant clinical value in the diagnosis, monitoring and efficacy evaluation of malignant tumors. In this work, a smartphone-based electrochemical point-of-care testing (POCT) platform for the detection of CEA was developed based on a Zr6MOF signal amplification strategy. Ferrocene labeled DNA strands (Fc-DNA) were immobilized on Zr6MOFs to form a Fc-DNA/Zr6MOF signal probe. Double-stranded DNA (dsDNA) formed by complementary DNA (cDNA) and CEA aptamer was assembled on a screen-printed electrode via an Au-S bond. When CEA was added, the aptamer specifically bound with CEA, resulting in the exposure of cDNA. Then, Fc-DNA/Zr6MOF signal probes were introduced on the electrode surface through hybridization between Fc-DNA and cDNA. The detection of CEA was realized by measuring the electrochemical response of Fc. The POCT device was made by connecting a modified electrode with a smartphone through a Sensit Smart USB flash disk. Due to the signal amplification of Zr6MOFs, this POCT platform exhibited high sensitivity, wide linear range, and low detection limit for CEA detection. The developed POCT platform has been used for the detection of CEA in actual human serum samples with satisfactory results.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Humanos , Antígeno Carcinoembrionário , DNA Complementar , Smartphone , DNA/química , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas , Limite de Detecção , Ouro/química
15.
Talanta ; 274: 126023, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38583328

RESUMO

Dual-potential ratiometric electrochemiluminescence (ECL) is in favor of resistance to environmental interference. However, two kinds of emitters or coreactants, and a wide scan potential range (>2 V) are mandatory. This work developed a new dual-potential ratiometric ECL sensor for detection of carcinoembryonic antigen (CEA) using single emitter (luminol) and single coreactant (H2O2) with a mild potential range from -0.1 to 0.6 V. Luminol could produce a strong cathodic ECL (Ec) induced by hydroxyl radicals (HO‧) from the reduction of H2O2, and a relatively weak anodic ECL (Ea). After the ferrocene modified CEA aptamer (Apt-Fc) was attached, Fc could promote Ea by catalyzing the oxidation of H2O2, and reduce Ec by consuming HO‧. With the cycling amplification of the exonuclease I, CEA could substantially reduce the amount of Apt-Fc, resulting in the decrease of Ea and the rise of Ec. So, the ratio of Ec to Ea (Ec/Ea) was used as the detection signal, realizing the sensitive determination of CEA from 0.1 pg mL-1 to 10 ng mL-1 with a LOD of 41.85 fg mL-1 (S/N = 3). The developed sensor demonstrated excellent specificity, stability and reproducibility, with satisfactory results in practical detection.


Assuntos
Aptâmeros de Nucleotídeos , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Peróxido de Hidrogênio , Medições Luminescentes , Luminol , Antígeno Carcinoembrionário/análise , Antígeno Carcinoembrionário/sangue , Técnicas Eletroquímicas/métodos , Humanos , Medições Luminescentes/métodos , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Luminol/química , Aptâmeros de Nucleotídeos/química , Limite de Detecção , Técnicas Biossensoriais/métodos , Metalocenos/química , Compostos Ferrosos/química
16.
Biochemistry ; 52(36): 6240-8, 2013 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-23947723

RESUMO

The motor function of smooth muscle myosin (SmM) is regulated by phosphorylation of the regulatory light chain (RLC) bound to the neck region of the SmM heavy chain. It is generally accepted that unphosphorylated RLC induces interactions between the two heads and between the head and the tail, thus inhibiting the motor activity of SmM, whereas phosphorylation of RLC interrupts those interactions, thus reversing the inhibition and restoring the motor activity to the maximal value. One assumption of this model is that single-headed SmM is fully active regardless of phosphorylation. To re-evaluate this model, we produced a number of SmM constructs with coiled coils of various lengths and examined their structure and regulation. With these constructs we identified the segment in the coiled-coil key for the formation of a stable double-headed structure. In agreement with the current model, we found that the actin-activated ATPase activity of unphosphorylated SmM increased with shortening of the coiled-coil. However, contrary to the current model, we found that the actin-activated ATPase activity of phosphorylated SmM decreased with shortening coiled-coil and only the stable double-headed SmM was fully activated by phosphorylation. These results indicate that single-headed SmM is neither fully active nor fully inhibited. Based on our findings, we propose that cooperation between the two heads is essential, not only for the inhibition of unphosphorylated SmM, but also for the activation of phosphorylated SmM.


Assuntos
Cadeias Pesadas de Miosina/metabolismo , Cadeias Leves de Miosina/metabolismo , Subfragmentos de Miosina/metabolismo , Animais , Galinhas , Eletroforese em Gel de Poliacrilamida , Ativação Enzimática , Microscopia Eletrônica , Músculo Liso/metabolismo , Cadeias Pesadas de Miosina/química , Cadeias Leves de Miosina/química , Subfragmentos de Miosina/química , Fosforilação
17.
Anal Chem ; 85(13): 6505-10, 2013 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-23725199

RESUMO

A modular labeling strategy was presented for electrochemical immunoassay via supramolecular host-guest interaction between ß-cyclodextrin (ß-CD) and adamantine (ADA). An ADA-labeled antibody (ADA-Ab) was synthesized via amidation, and the number of ADA moieties loaded on a single antibody was calculated to be ~7. The ß-CD-functionalized gold-palladium bimetallic nanoparticles (AuPd-CD) were synthesized in aqueous solution via metal-S chemistry and characterized with transmission electron microscopy and X-ray photoelectron spectra. After the ADA-Ab was bound to the antigen-modified electrode surface with a competitive immunoreaction, AuPd-CD as a signal tag was immobilized onto the immunosensor by a host-guest interaction, leading to a large loading of AuPd nanoparticles. The highly efficient electrocatalysis by AuPd nanoparticles for NaBH4 oxidation produced an ultrasensitive response to chloramphenicol as a model of a small molecule antigen. The immunoassay method showed a wide linear range from 50 pg/mL to 50 µg/mL and a detection limit of 4.6 pg/mL. The specific recognition of antigen by antibody resulted in good selectivity for the proposed method. The host-guest interaction strategy provided a universal labeling approach for the ultrasensitive detection of small molecule targets.


Assuntos
Amantadina/análogos & derivados , Técnicas Eletroquímicas/métodos , Ouro/química , Chumbo/química , Nanopartículas Metálicas/química , beta-Ciclodextrinas/análise , Amantadina/análise , Amantadina/metabolismo , Imunoensaio , Ligação Proteica/fisiologia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , beta-Ciclodextrinas/metabolismo
18.
Chemistry ; 19(1): 102-8, 2013 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-23239539

RESUMO

A surface-assisted laser desorption/ionization time-of-flight mass spectrometric (SALDI-TOF MS) method was developed for the analysis of small biomolecules by using functional single-walled carbon nanohorns (SWNHs) as matrix. The functional SWNHs could transfer energy to the analyte under laser irradiation for accelerating its desorption and ionization, which led to low matrix effect, avoided fragmentation of the analyte, and provided high salt tolerance. Biomolecules including amino acids, peptides, and fatty acids could successfully be analyzed with about 3- and 5-fold higher signals than those obtained using conventional matrix. By integrating the advantages of SWNHs and the recognition ability of aptamers, a selective approach was proposed for simultaneous capture, enrichment, ionization, and MS detection of adenosine triphosphate (ATP). This method showed a greatly improved detection limit (1.0 µM) for the analysis of ATP in complex biological samples. This newly designed protocol not only opened a new application of SWNHs, but also offered a new technique for selective MS analysis of biomolecules based on aptamer recognition systems.


Assuntos
Trifosfato de Adenosina/análise , Aminoácidos/análise , Ácidos Graxos/análise , Nanotubos de Carbono/química , Peptídeos/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Aptâmeros de Nucleotídeos/química , Modelos Químicos
19.
World J Oncol ; 14(3): 205-223, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37350808

RESUMO

Background: Transcription factor Dp-1 (TFDP1) was overexpressed and interacted with other genes to impact multiple signaling pathways in various human cancers. However, there is less research about the TFDP1 specific roles in lung adenocarcinoma (LUAD). Methods: We first explored TFDP1 expression levels and relative diseases from a pan-cancer perspective using the ONCOMINE, TIMER, and Open Targets Platform databases. Then, we used UALCAN, GEPIA 2, TCGA-LUAD data, and Kaplan-Meier plotter to examine TFDP1 clinicopathological features and prognosis in LUAD patients. Genomic alterations and DNA methylation analysis were performed by cBioPortal and MethSurv, respectively. Then, we used a cancer single-cell state atlas (CancerSEA) to find TFDP1 functions at a single-cell resolution. LinkedOmics was used to find TFDP1 coexpressed genes, biological processes, and Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways. Then, Gene Set Cancer Analysis (GSCA) was used to examine the drug resistence of TFDP1 in LUAD. Results: We found that TFDP1 was overexpressed in most human cancers and related to various diseases, including LUAD. Moreover, LUAD patients with high TFDP1 expression levels might be significantly associated with individual cancer stages and have a poor prognosis. Multivariate analysis revealed that the American Joint Committee on Cancer (AJCC) pathologic stage, AJCC stage T, and AJCC stage N were the independent prognostic factors. LUAD patients with TFDP1 alterations suggested poor overall survival (OS), and disease-free survival (DFS), while hypermethylation might lead to a good prognosis. TFDP1 and its coexpressed genes were enriched in multiple signaling pathways and biological processes involved in the cell cycle, spliceosome, and DNA replication. Furthermore, TFDP1 was strongly positively related to the half-maximal inhibitory concentration (IC50) values of multiple drugs. Conclusions: In summary, TFDP1 was a possible biomarker and potential therapeutic target for LUAD patients.

20.
Biosens Bioelectron ; 226: 115116, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36753989

RESUMO

DNA nanomachines have shown potential application in the construction of various biosensors. Here, an electrochemiluminescence biosensor for the sensitive detection of miRNA-21 were reported based on three-dimensional (3D) DNA nanomachine and duplex-specific nuclease (DSN)-mediated target recycle amplification strategy. First, the bipedal DNA walkers were obtained by DSN-mediated digestion reaction initiated by target miRNA-21.3D DNA tracks were prepared by modifying Fe3O4 magnetic beads (MBs) with ferrocene-labeled DNA (Fc-DNA). The produced DNA walkers autonomously moved along 3D DNA tracks powered by nicking endonuclease. During the movement, ferrocene-labeled DNA was cleaved, resulting in large amounts of Fc-labeled DNA fragments away from the MBs surface. Finally, the liberated Fc-labeled DNA fragments were dropped on the C-g-C3N4 modified electrode surface, leading to the quenching of C-g-C3N4 electrochemiluminescence (ECL). Benefiting from the dual amplification strategy of 3D DNA nanomachine and DSN-mediated target recycling, the developed ECL biosensor exhibited an excellent performance for miRNA-21 detection with a wide linear range of 10 fM to 10 nM and a low detection limit of 1.0 fM. This work offers a new thought for the application of DNA walkers in the construction of various biosensors.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Metalocenos , Medições Luminescentes/métodos , Endonucleases , Limite de Detecção , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , DNA/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA