N Engl J Med ; 388(4): 299-309, 2023 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-36720132

RESUMO

BACKGROUND: Extracorporeal cardiopulmonary resuscitation (CPR) restores perfusion and oxygenation in a patient who does not have spontaneous circulation. The evidence with regard to the effect of extracorporeal CPR on survival with a favorable neurologic outcome in refractory out-of-hospital cardiac arrest is inconclusive. METHODS: In this multicenter, randomized, controlled trial conducted in the Netherlands, we assigned patients with an out-of-hospital cardiac arrest to receive extracorporeal CPR or conventional CPR (standard advanced cardiac life support). Eligible patients were between 18 and 70 years of age, had received bystander CPR, had an initial ventricular arrhythmia, and did not have a return of spontaneous circulation within 15 minutes after CPR had been initiated. The primary outcome was survival with a favorable neurologic outcome, defined as a Cerebral Performance Category score of 1 or 2 (range, 1 to 5, with higher scores indicating more severe disability) at 30 days. Analyses were performed on an intention-to-treat basis. RESULTS: Of the 160 patients who underwent randomization, 70 were assigned to receive extracorporeal CPR and 64 to receive conventional CPR; 26 patients who did not meet the inclusion criteria at hospital admission were excluded. At 30 days, 14 patients (20%) in the extracorporeal-CPR group were alive with a favorable neurologic outcome, as compared with 10 patients (16%) in the conventional-CPR group (odds ratio, 1.4; 95% confidence interval, 0.5 to 3.5; P = 0.52). The number of serious adverse events per patient was similar in the two groups. CONCLUSIONS: In patients with refractory out-of-hospital cardiac arrest, extracorporeal CPR and conventional CPR had similar effects on survival with a favorable neurologic outcome. (Funded by the Netherlands Organization for Health Research and Development and Maquet Cardiopulmonary [Getinge]; INCEPTION ClinicalTrials.gov number, NCT03101787.).


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Suporte Vital Cardíaco Avançado/métodos , Reanimação Cardiopulmonar/métodos , Hospitalização , Parada Cardíaca Extra-Hospitalar/mortalidade , Parada Cardíaca Extra-Hospitalar/terapia , Fibrilação Ventricular/terapia , Países Baixos
2.
Basic Res Cardiol ; 119(3): 371-395, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38700707

RESUMO

Ascending thoracic aortic aneurysm (ATAA) remains a significant medical concern, with its asymptomatic nature posing diagnostic and monitoring challenges, thereby increasing the risk of aortic wall dissection and rupture. Current management of aortic repair relies on an aortic diameter threshold. However, this approach underestimates the complexity of aortic wall disease due to important knowledge gaps in understanding its underlying pathologic mechanisms.Since traditional risk factors cannot explain the initiation and progression of ATAA leading to dissection, local vascular factors such as extracellular matrix (ECM) and vascular smooth muscle cells (VSMCs) might harbor targets for early diagnosis and intervention. Derived from diverse embryonic lineages, VSMCs exhibit varied responses to genetic abnormalities that regulate their contractility. The transition of VSMCs into different phenotypes is an adaptive response to stress stimuli such as hemodynamic changes resulting from cardiovascular disease, aging, lifestyle, and genetic predisposition. Upon longer exposure to stress stimuli, VSMC phenotypic switching can instigate pathologic remodeling that contributes to the pathogenesis of ATAA.This review aims to illuminate the current understanding of cellular and molecular characteristics associated with ATAA and dissection, emphasizing the need for a more nuanced comprehension of the impaired ECM-VSMC network.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Músculo Liso Vascular , Miócitos de Músculo Liso , Humanos , Aneurisma da Aorta Torácica/patologia , Aneurisma da Aorta Torácica/genética , Aneurisma da Aorta Torácica/metabolismo , Aneurisma da Aorta Torácica/fisiopatologia , Dissecção Aórtica/patologia , Dissecção Aórtica/genética , Dissecção Aórtica/metabolismo , Animais , Músculo Liso Vascular/patologia , Músculo Liso Vascular/metabolismo , Miócitos de Músculo Liso/patologia , Miócitos de Músculo Liso/metabolismo , Aorta Torácica/patologia , Aorta Torácica/fisiopatologia , Remodelação Vascular , Matriz Extracelular/patologia , Matriz Extracelular/metabolismo , Fenótipo
3.
Crit Care ; 28(1): 217, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961495

RESUMO

BACKGROUND: The outcomes of several randomized trials on extracorporeal cardiopulmonary resuscitation (ECPR) in patients with refractory out-of-hospital cardiac arrest were examined using frequentist methods, resulting in a dichotomous interpretation of results based on p-values rather than in the probability of clinically relevant treatment effects. To determine such a probability of a clinically relevant ECPR-based treatment effect on neurological outcomes, the authors of these trials performed a Bayesian meta-analysis of the totality of randomized ECPR evidence. METHODS: A systematic search was applied to three electronic databases. Randomized trials that compared ECPR-based treatment with conventional CPR for refractory out-of-hospital cardiac arrest were included. The study was preregistered in INPLASY (INPLASY2023120060). The primary Bayesian hierarchical meta-analysis estimated the difference in 6-month neurologically favorable survival in patients with all rhythms, and a secondary analysis assessed this difference in patients with shockable rhythms (Bayesian hierarchical random-effects model). Primary Bayesian analyses were performed under vague priors. Outcomes were formulated as estimated median relative risks, mean absolute risk differences, and numbers needed to treat with corresponding 95% credible intervals (CrIs). The posterior probabilities of various clinically relevant absolute risk difference thresholds were estimated. RESULTS: Three randomized trials were included in the analysis (ECPR, n = 209 patients; conventional CPR, n = 211 patients). The estimated median relative risk of ECPR for 6-month neurologically favorable survival was 1.47 (95%CrI 0.73-3.32) with a mean absolute risk difference of 8.7% (- 5.0; 42.7%) in patients with all rhythms, and the median relative risk was 1.54 (95%CrI 0.79-3.71) with a mean absolute risk difference of 10.8% (95%CrI - 4.2; 73.9%) in patients with shockable rhythms. The posterior probabilities of an absolute risk difference > 0% and > 5% were 91.0% and 71.1% in patients with all rhythms and 92.4% and 75.8% in patients with shockable rhythms, respectively. CONCLUSION: The current Bayesian meta-analysis found a 71.1% and 75.8% posterior probability of a clinically relevant ECPR-based treatment effect on 6-month neurologically favorable survival in patients with all rhythms and shockable rhythms. These results must be interpreted within the context of the reported credible intervals and varying designs of the randomized trials. REGISTRATION: INPLASY (INPLASY2023120060, December 14th, 2023, https://doi.org/10.37766/inplasy2023.12.0060 ).


Assuntos
Teorema de Bayes , Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/terapia , Parada Cardíaca Extra-Hospitalar/mortalidade , Reanimação Cardiopulmonar/métodos , Reanimação Cardiopulmonar/normas , Oxigenação por Membrana Extracorpórea/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Resultado do Tratamento
4.
Eur Heart J ; 44(41): 4357-4372, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37638786

RESUMO

BACKGROUND AND AIMS: The current study proposes a novel volume-outcome (V-O) meta-analytical approach to determine the optimal annual hospital case volume threshold for cardiovascular interventions in need of centralization. This novel method is applied to surgery for acute type A aortic dissection (ATAAD) as an illustrative example. METHODS: A systematic search was applied to three electronic databases (1 January 2012 to 29 March 2023). The primary outcome was early mortality in relation to annual hospital case volume. Data were presented by volume quartiles (Qs). Restricted cubic splines were used to demonstrate the V-O relation, and the elbow method was applied to determine the optimal case volume. For clinical interpretation, numbers needed to treat (NNTs) were calculated. RESULTS: One hundred and forty studies were included, comprising 38 276 patients. A significant non-linear V-O effect was observed (P < .001), with a notable between-quartile difference in early mortality rate [10.3% (Q4) vs. 16.2% (Q1)]. The optimal annual case volume was determined at 38 cases/year [95% confidence interval (CI) 37-40 cases/year, NNT to save a life in a centre with the optimal volume vs. 10 cases/year = 21]. More pronounced between-quartile survival differences were observed for long-term survival [10-year survival (Q4) 69% vs. (Q1) 51%, P < .01, adjusted hazard ratio 0.83, 95% CI 0.75-0.91 per quartile, NNT to save a life in a high-volume (Q4) vs. low-volume centre (Q1) = 6]. CONCLUSIONS: Using this novel approach, the optimal hospital case volume threshold was statistically determined. Centralization of ATAAD care to high-volume centres may lead to improved outcomes. This method can be applied to various other cardiovascular procedures requiring centralization.


Assuntos
Dissecção Aórtica , Hospitais com Alto Volume de Atendimentos , Humanos , Resultado do Tratamento , Dissecção Aórtica/cirurgia , Estudos Retrospectivos
5.
Eur Heart J ; 44(2): 100-112, 2023 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-36337034

RESUMO

The use of biomarkers is undisputed in the diagnosis of primary myocardial infarction (MI), but their value for identifying MI is less well studied in the postoperative phase following coronary artery bypass grafting (CABG). To identify patients with periprocedural MI (PMI), several conflicting definitions of PMI have been proposed, relying either on cardiac troponin (cTn) or the MB isoenzyme of creatine kinase, with or without supporting evidence of ischaemia. However, CABG inherently induces the release of cardiac biomarkers, as reflected by significant cTn concentrations in patients with uncomplicated postoperative courses. Still, the underlying (patho)physiological release mechanisms of cTn are incompletely understood, complicating adequate interpretation of postoperative increases in cTn concentrations. Therefore, the aim of the current review is to present these potential underlying mechanisms of cTn release in general, and following CABG in particular (Graphical Abstract). Based on these mechanisms, dissimilarities in the release of cTnI and cTnT are discussed, with potentially important implications for clinical practice. Consequently, currently proposed cTn biomarker cut-offs by the prevailing definitions of PMI might warrant re-assessment, with differentiation in cut-offs for the separate available assays and surgical strategies. To resolve these issues, future prospective studies are warranted to determine the prognostic influence of biomarker release in general and PMI in particular.


Assuntos
Ponte de Artéria Coronária , Infarto do Miocárdio , Humanos , Ponte de Artéria Coronária/efeitos adversos , Infarto do Miocárdio/etiologia , Troponina I , Troponina T , Biomarcadores
6.
Neth Heart J ; 32(6): 228-237, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38776039

RESUMO

This paper presents an overview of the development of an integrated patient-centred cardiac care registry spanning the initial 5 years (September 2017 to December 2022). The Netherlands Heart Registration facilitates registration committees in which mandated cardiologists and cardiothoracic surgeons structurally evaluate quality of care using real-world data. With consistent attendance rates exceeding 60%, a valuable network is supported. Over time, the completeness level of the registry has increased. Presently, four out of six quality registries show over 95% completeness in variables that are part of the quality policies of cardiology and cardiothoracic surgery societies. Notably, 93% of the centres voluntarily report outcomes related to open heart surgery and (trans)catheter interventions publicly. Moreover, outcomes after implantable cardioverter-defibrillator and pacemaker procedures are transparently reported by 26 centres. Multiple innovation projects have been initiated by the committees, signalling a shift from publishing outcomes transparently to collaborative efforts in sharing healthcare processes and investigating improvement initiatives. The next steps will focus on the entire pathway of cardiac care for a specific medical condition instead of focusing solely on the outcomes of the procedures. This redirection of focus to a comprehensive assessment of the patient pathway in cardiac care ultimately aims to optimise outcomes for all patients.

7.
Curr Opin Crit Care ; 29(6): 633-639, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37865873

RESUMO

PURPOSE OF REVIEW: Extracorporeal cardiopulmonary resuscitation (ECPR) is an emerging treatment for refractory cardiac arrest. In recent years, several randomized controlled trials have been published that aimed to address the efficacy and effectiveness of ECPR for out-of-hospital cardiac arrest (OHCA). Despite the lack of high-quality evidence concerning clinical effectiveness and cost-effectiveness, ECPR is increasingly implemented throughout the world. In this review, we aim to provide an overview of the current status of ECPR for OHCA. RECENT FINDINGS: Randomized controlled trials showed diverging results, largely due to differences in selection criteria and study design. Single-center studies, performed in centers with extraordinary expertise and dedication consistently achieve a low-flow time of around 60 min, but such achievements are rarely reproduced outside these centers. Strict patient selection can improve outcome but simultaneously limits the caseload. Preliminary data suggest that outcome may also be improved by avoiding hyperoxia postresuscitation. SUMMARY: The potential of ECPR to increase survival in selected patients in highly dedicated systems seems to be proven, the question remains whether ECPR for OHCA can be widely implemented successfully and can develop into a sustainable, commonplace resource-effective treatment.


Assuntos
Reanimação Cardiopulmonar , Oxigenação por Membrana Extracorpórea , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/terapia , Oxigenação por Membrana Extracorpórea/métodos , Reanimação Cardiopulmonar/métodos , Resultado do Tratamento , Seleção de Pacientes , Estudos Retrospectivos
8.
Clin Chem ; 68(12): 1564-1575, 2022 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-36366960

RESUMO

BACKGROUND: Cardiac troponin I and T are both used for diagnosing myocardial infarction (MI) after coronary artery bypass grafting (CABG), also known as type 5 MI (MI-5). Different MI-5 definitions have been formulated, using multiples of the 99th percentile upper reference limit (10×, 35×, or 70× URL), with or without supporting evidence. These definitions are arbitrarily chosen based on conventional assays and do not differentiate between troponin I and T. We therefore investigated the kinetics of high-sensitivity cardiac troponin I (hs-cTnI) and T (hs-cTnT) following CABG. METHODS: A systematic search was applied to MEDLINE and EMBASE databases including the search terms "coronary artery bypass grafting" AND "high-sensitivity cardiac troponin." Studies reporting hs-cTnI or hs-cTnT on at least 2 different time points were included. Troponin concentrations were extracted and normalized to the assay-specific URL. RESULTS: For hs-cTnI and hs-cTnT, 17 (n = 1661 patients) and 15 studies (n = 2646 patients) were included, respectively. Preoperative hs-cTnI was 6.1× URL (95% confidence intervals: 4.9-7.2) and hs-cTnT 1.2× URL (0.9-1.4). Mean peak was reached 6-8 h postoperatively (126× URL, 99-153 and 45× URL, 29-61, respectively). Subanalysis of hs-cTnI illustrated assay-specific peak heights and kinetics, while subanalysis of surgical strategies revealed 3-fold higher hs-cTnI than hs-cTnT for on-pump CABG and 5-fold for off-pump CABG. CONCLUSION: Postoperative hs-cTnI and hs-cTnT following CABG surpass most current diagnostic cutoff values. hs-cTnI was almost 3-fold higher than hs-cTnT, and appeared to be highly dependent on the assay used and surgical strategy. There is a need for assay-specific hs-cTnI and hs-cTnT cutoff values for accurate, timely identification of MI-5.


Assuntos
Infarto do Miocárdio , Troponina I , Humanos , Troponina T , Ponte de Artéria Coronária , Infarto do Miocárdio/diagnóstico , Bioensaio , Biomarcadores
9.
Eur J Neurol ; 29(4): 1187-1197, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34967067

RESUMO

BACKGROUND AND PURPOSE: Anti-acetylcholine receptor (AChR) antibodies (ab) in the serum are detected in most patients with generalized myasthenia gravis (MG) and used as a diagnostic tool. The aim of this study was to analyse a possible association between anti-AChR-ab serum levels and clinical improvement of MG. METHODS: The Maastricht University Medical Center is a centre of expertise for the treatment of MG. Between 1997 and 2020, more than 4000 anti-AChR-ab blood samples were measured for clinical care using a quantitative radioimmunoassay technique. These results, in combination with clinical status obtained from the patients' electronic patient files, were retrospectively analysed by a single blinded clinician. Symptoms of MG were classified using the Myasthenia Gravis Foundation of America (MGFA) scale. RESULTS: In total, 90 anti-AChR-ab-positive MG patients with 837 blood samples were included. The median follow-up time was 72 months. The majority of the included patients were women (61.1%), were on immunosuppressive drug therapy (88.9%), and underwent a thymectomy (54.4%). Multilevel logistic regression analysis showed a significantly inverse association between change in anti-AChR-ab level and the odds of MGFA improvement (per 10% decrease of anti-AChR-ab level: odds ratio 1.21, 95% confidence interval 1.12-1.31; p < 0.001). CONCLUSIONS: A change in anti-AChR-ab serum level is associated with clinical status in patients with MG. Analyses of anti-AChR-ab are not only useful for diagnostics but also in follow-up of adult symptomatic patients with MG. The use of repetitive anti-AChR-ab serum levels might be valuable in long-term monitoring for clinical improvement in patients with MG, however, further research is required for specific recommendations.


Assuntos
Miastenia Gravis , Receptores Colinérgicos , Adulto , Autoanticorpos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Timectomia
10.
Eur J Vasc Endovasc Surg ; 63(5): 674-687, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35379543

RESUMO

OBJECTIVE: The extent of aortic replacement during surgery for acute type A aortic dissection (ATAAD) is an important matter of debate. This meta-analysis aimed to evaluate the short and long term outcomes of a proximal aortic repair (PAR) vs. total arch replacement (TAR) in the treatment of ATAAD. DATA SOURCES: A systematic search of PubMed and Embase was performed. Studies comparing PAR to TAR for ATAAD were included. REVIEW METHODS: The primary outcomes were early death and long term actuarial survival at one, five, and 10 years. Random effects models in conjunction with relative risks (RRs) were used for meta-analyses. RESULTS: Nineteen studies were included, comprising 5 744 patients (proximal: n = 4 208; total arch: n = 1 536). PAR was associated with reduced early mortality (10.8% [95% confidence interval (CI) 8.4 - 13.7] vs. 14.0% [95% CI 10.4 - 18.7]; RR 0.73 [95% CI 0.63 - 0.85]) and reduced post-operative renal failure (10.4% [95% CI 7.2 - 14.8] vs. 11.1% [95% CI 6.7 - 17.5]; RR 0.77 [95% CI 0.66 - 0.90]), but there was no difference in stroke (8.0% [95% CI 5.9 - 10.7] vs. 7.3% [95% CI 4.6 - 11.3]; RR 0.87 [95% CI 0.69 - 1.10]). No statistically significant difference was found for survival after one year (83.2% [95% CI 77.5 - 87.7] vs. 78.6% [95% CI 69.7 - 85.5]; RR 1.05 [95% CI 0.99 - 1.11]), which persisted after five years (75.4% [95% CI 71.2 - 79.2] vs. 74.5% [95% CI 64.7 - 82.3]; RR 1.02 [95% CI 0.91 - 1.14]). After 10 years, there was a significant survival benefit for patients who underwent TAR (64.7% [95% CI 61.1 - 68.1] vs. 72.4% [95% CI 67.5 - 76.7]; RR 0.91 [95% CI 0.84 - 0.99]). CONCLUSION: PAR appears to lead to an improved early mortality rate and a reduced complication rate. In the current meta-analysis, the suggestion of an improved 10 year survival benefit of TAR was found, which should be interpreted in the context of potential confounders such as age at presentation, comorbidities, and haemodynamic stability. In any case, PAR seems to be intuitive in older patients with limited dissections, and in those presenting in less stable conditions.

11.
Europace ; 24(6): 1015-1024, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35348667

RESUMO

AIMS: Although in persistent atrial fibrillation (AF) a complex AF substrate characterized by a high incidence of conduction block has been reported, relatively little is known about AF complexity in paroxysmal AF (pAF). Also, the relative contribution of various aspects of structural alterations to conduction disturbances is not clear. In particular, the contribution of endomysial fibrosis to conduction disturbances during progression of AF has not been studied yet. METHODS AND RESULTS: During cardiac surgery, epicardial high-density mapping was performed in patients with acutely induced (aAF, n = 11), pAF (n = 12), and longstanding persistent AF (persAF, n = 9) on the right atrial (RA) wall, the posterior left atrial wall (pLA) and the LA appendage (LAA). In RA appendages, overall and endomysial (myocyte-to-myocyte distances) fibrosis and connexin 43 (Cx43) distribution were quantified. Unipolar AF electrogram analysis showed a more complex pattern with a larger number of narrower waves, more breakthroughs and a higher fractionation index (FI) in persAF compared with aAF and pAF, with no differences between aAF and pAF. The FI was consistently higher at the pLA compared with the RA. Structurally, Cx43 lateralization increased with AF progression (aAF = 7.5 ± 8.9%, pAF = 24.7 ± 11.1%, persAF = 35.1 ± 11.4%, P < 0.001). Endomysial but not overall fibrosis correlated with AF complexity (r = 0.57, P = 0.001; r = 0.23, P = 0.20; respectively). CONCLUSIONS: Atrial fibrillation complexity is highly variable in patients with pAF, but not significantly higher than in patients with acutely induced AF, while in patients with persistent AF complexity is higher. Among the structural alterations studied, endomysial fibrosis, but not overall fibrosis, is the strongest determinant of AF complexity.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Tecido Conjuntivo , Conexina 43 , Fibrose , Átrios do Coração , Humanos
12.
Europace ; 24(5): 784-795, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-34718532

RESUMO

AIMS: Investigate haemodynamic effects, and their mechanisms, of restoring atrioventricular (AV)-coupling using pacemaker therapy in normal and failing hearts in a combined computational-experimental-clinical study. METHODS AND RESULTS: Computer simulations were performed in the CircAdapt model of the normal and failing human heart and circulation. Experiments were performed in a porcine model of AV dromotropathy. In a proof-of-principle clinical study, left ventricular (LV) pressure and volume were measured in 22 heart failure (HF) patients (LV ejection fraction <35%) with prolonged PR interval (>230 ms) and narrow or non-left bundle branch block QRS complex. Computer simulations and animal studies in normal hearts showed that restoring of AV-coupling with unchanged ventricular activation sequence significantly increased LV filling, mean arterial pressure, and cardiac output by 10-15%. In computer simulations of failing hearts and in HF patients, reducing PR interval by biventricular (BiV) pacing (patients: from 300 ± 61 to 137 ± 30 ms) resulted in significant increases in LV stroke volume and stroke work (patients: 34 ± 40% and 26 ± 31%, respectively). However, worsening of ventricular dyssynchrony by using right ventricular (RV) pacing abrogated the benefit of restoring AV-coupling. In model simulations, animals and patients, the increase of LV filling and associated improvement of LV pump function coincided with both larger mitral inflow (E- and A-wave area) and reduction of diastolic mitral regurgitation. CONCLUSION: Restoration of AV-coupling by BiV pacing in normal and failing hearts with prolonged AV conduction leads to considerable haemodynamic improvement. These results indicate that BiV or physiological pacing, but not RV pacing, may improve cardiac function in patients with HF and prolonged PR interval.


Assuntos
Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Animais , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração , Humanos , Volume Sistólico , Suínos , Função Ventricular Esquerda/fisiologia
13.
J Card Surg ; 37(12): 4362-4370, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36229944

RESUMO

OBJECTIVES: Mitral valve (MV) disease is often accompanied by tricuspid valve (TV) disease. The indication for concomitant TV surgery during primary MV surgery is expected to increase, especially through a minimally invasive surgical (MIS) approach. The aim of the current study is to investigate the safety of the addition of TV surgery to MV surgery in MIMVS in a nationwide registry. METHODS: Patients undergoing atrioventricular valve surgery through sternotomy or MIS between 2013 and 2018 were included. Patients undergoing MV surgery only through sternotomy or MIS were used as comparison. Primary outcomes were short-term morbidity and mortality and long-term survival. Propensity score matching was used to correct for potential confounders. RESULTS: The whole cohort consisted of 2698 patients. A total of 558 patients had atrioventricular double valve surgery through sternotomy and 86 through MIS. As a comparison, 1365 patients underwent MV surgery through sternotomy and 689 patients through MIS. No differences in 30- and 120-day mortality were observed between the groups, both unmatched and matched. 5-year survival did not differ for double atrioventricular valve surgery through either sternotomy or MIS in the matched population (90.1% vs. 95.3%, Log-Rank p = .12). A higher incidence of re-exploration for bleeding (n = 12 [15.2%] vs. n = 3 [3.8%], p = .02) and new onset arrhythmia (n = 35 [44.3%] vs. n = 13 [16.5%], p < .001) was observed in double valve surgery through MIS. Median length of hospital stay (LOHS) was longer in the minimally invasive double valve group (9 days [6-13]) compared with sternotomy (7 days [6-11]; p = .04). CONCLUSION: No differences in short-term mortality and 5-year survival were observed when tricuspid valve was added to MV surgery in MIS or sternotomy. The addition of tricuspid valve surgery is associated with higher incidence of re-exploration for bleeding, new onset arrhythmia. A longer LOHS was observed for MIS compared to sternotomy.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Humanos , Valva Mitral/cirurgia , Valva Tricúspide/cirurgia , Países Baixos , Resultado do Tratamento , Doenças das Valvas Cardíacas/cirurgia , Esternotomia , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Retrospectivos
14.
J Card Surg ; 37(11): 3984-3987, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36047388

RESUMO

There are limits to the use of cardioplegic arrest during complex cardiac surgical procedures, especially in patients with severe left ventricular dysfunction. In the current report, we graphically present the detailed surgical strategy and technique for beating-heart aortic root replacement with concomitant coronary bypass grafting, for patients otherwise deemed inoperable. With support of cardiopulmonary bypass (CPB), beating-heart bypass surgery is realized, after which the bypass grafts can selectively be connected to the CPB, preserving coronary flow. Then, on the beating and perfused heart, a complex procedure such as aortic root replacement can be performed, without jeopardizing postoperative cardiac function. However, several important caveats and remarks regarding the use of beating-heart surgery should be considered, including: coronary perfusion verification and maintenance, temperature management, and prevention of air embolisms. By use of this strategy, risks associated with cardioplegic arrest are minimized, while it circumvents the potential need for long-term postoperative extracorporeal membrane oxygenation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Disfunção Ventricular Esquerda , Valva Aórtica , Ponte Cardiopulmonar/métodos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/cirurgia
15.
J Card Surg ; 37(12): 4630-4638, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36349741

RESUMO

BACKGROUND: Hybrid ablation (HA) of atrial fibrillation (AF) combines minimally invasive thoracoscopic epicardial ablation with transvenous endocardial electrophysiologic validation and touch-up of incomplete epicardial lesions if needed. While studies have reported on a bilateral thoracoscopic HA approach, data on a unilateral left-sided approach are scarce. AIM: To evaluate the efficacy and safety of a unilateral left-sided thoracoscopic approach. METHODS: Retrospective analysis of a prospectively gathered cohort of all consecutive patients undergoing a unilateral left-sided HA for AF between 2015 and 2018 in the Maastricht University Medical Centre. RESULTS: One-hundred nineteen patients were analyzed (mean age 64 ± 8, 28% female, mean body mass index 28 ± 4 kg/m2 , median CHA2 DS2 -VASc Score 2 [1-3], [longstanding]-persistent AF 71%, previous catheter ablation 44%). In all patients, a unilateral left-sided HA consisting of pulmonary vein (PV) isolation, posterior left atrial (LA) wall isolation, and LA appendage exclusion was attempted. Epicardial (n = 59) and/or endocardial validation (n = 81) was performed and endocardial touch-up was performed in 33 patients. Major peri-operative complications occurred in 5% of all patients. After 12 and 24 months, the probability of being free from supraventricular tachyarrhythmia recurrence was 80% [73-87] and 67% [58-76], respectively, when allowing antiarrhythmic drugs. CONCLUSION: Unilateral left-sided hybrid AF ablation is an efficacious and safe approach to treat patients with paroxysmal and (longstanding) persistent AF. Future studies should compare a unilateral with a bilateral approach to determine whether a left-sided approach is as efficacious as a bilateral approach and allows for less complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Toracoscopia , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
16.
Perfusion ; 37(1): 69-77, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33325335

RESUMO

INTRODUCTION: This study aimed to test a computer-driven cardiovascular model for the evaluation of the visceral flow during intra-aortic balloon pump (IABP) assistance. METHODS: The model includes a systemic and pulmonary circulation as well as a heart contraction model. The straight polyurethane tube aorta had a single visceral while four windkessel components mimicked resistance compliance of the brachiocephalic, renal and sub-mesenteric, pulmonary, and systemic circulation. Twelve flow probes were placed in the circuit to measure pressures and flows with the IABP on and off. RESULTS: With the balloon off, the meantime to reach the steady state was 48 ± 16 s; with the balloon on, this figure was 178 ± 20 s. The stability of pressure and flow signals was obtained after 72 ± 11 min. The number of cycles of stability of the system was 93 [86-103]. Measurements were reliable either with samples of 10 or 20 beats. Bland Altman method demonstrated the reliability of measurements. Finally, all measurements were comparable to published in vivo data. CONCLUSION: The presented mock circulation was reliable and gave values with high accuracy both at baseline and during mechanical assistance. This system allows evaluation of the mesenteric flow during IABP, under different clinical/hemodynamic conditions. Nonetheless, its translational potential needs to be further evaluated.


Assuntos
Contrapulsação , Coração Auxiliar , Aorta , Circulação Coronária , Hemodinâmica , Humanos , Balão Intra-Aórtico/métodos , Reprodutibilidade dos Testes
17.
J Surg Res ; 259: 332-341, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33127067

RESUMO

BACKGROUND: Three-dimensional (3D) imaging is being used progressively to create models of patients with anterior chest wall deformities. Resulting models are used for clinical decision-making, surgical planning, and analysis. However, given the broad range of 3D imaging systems available and the fact that planning and analysis techniques are often only validated for a single system, it is important to analyze potential intrasystem and intersystem differences. The objective of this study was to investigate the accuracy and reproducibility of three commercially available 3D imaging systems that are used to obtain images of the anterior chest wall. METHODS: Among 15 healthy volunteers, 3D images of the anterior chest wall were acquired twice per imaging device. Reproducibility was determined by comparison of consecutive images acquired per device while the true accuracy was calculated by comparison of 3D image derived and calipered anthropometric measurements. A maximum difference of 1.00 mm. was considered clinically acceptable. RESULTS: All devices demonstrated statistically comparable (P = 0.21) reproducibility with a mean absolute difference of 0.59 mm. (SD: 1.05), 0.54 mm. (SD: 2.08), and 0.48 mm. (SD: 0.60) for the 3dMD, EinScan Pro 2X Plus, and Artec Leo, respectively. The true accuracy was, respectively, 0.89 mm. (SD: 0.66), 1.27 mm. (SD: 0.94), and 0.81 mm. (SD: 0.71) for the 3dMD, EinScan, and Artec device and did not statistically differ (P = 0.085). CONCLUSIONS: Three-dimensional imaging of the anterior chest wall utilizing the 3dMD and Artec Leo is feasible with comparable reproducibility and accuracy, whereas the EinScan Pro 2X Plus is reproducible but not clinically accurate.


Assuntos
Antropometria/instrumentação , Imageamento Tridimensional/instrumentação , Planejamento de Assistência ao Paciente , Parede Torácica/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Estudos de Viabilidade , Voluntários Saudáveis , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Parede Torácica/anormalidades , Adulto Jovem
18.
Europace ; 23(23 Suppl 2): ii28-ii33, 2021 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-33837755

RESUMO

Despite many years of research, the different aspects of the mechanism of atrial fibrillation (AF) are still incompletely understood. And although the latest guidelines recommend catheter ablation with pulmonary vein isolation as a rhythm control strategy, long-term results in persistent and long-standing persistent AF are suboptimal. Historically, a mechanistic-based patient-tailored approach for the treatment of AF was impossible because of the lack real-time mapping techniques and advanced ablation tools. Therefore, surgeons created lesion sets based upon the anatomy of both atria and the safety of the incisions made by the knife. These complex open-heart procedures had to be performed through a sternotomy on the arrested heart and where therefore not generally adopted. The use of controlled energy sources such as cryothermy and radiofrequency where the first step to make the creation of these lesions less complex. With the development and improvement of electrophysiology techniques and catheters, this invasive and solely anatomical approach could again be partially redesigned. Now less invasive, it prepared the way for collaboration between electrophysiologists working on the endocardial side of the heart and cardiac surgeons providing epicardial access. The introduction of video-assisted technology and hybrid procedures has further increased the possibilities of new successful therapies. Now more than 40 years since the beginning of this exciting maze of AF procedures and still working towards a less aggressive and more comprehensive approach we give an overview of the history of the different minimally invasive surgical solutions and of the hybrid approach.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Endocárdio/cirurgia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Veias Pulmonares/cirurgia , Resultado do Tratamento
19.
Europace ; 23(23 Suppl 1): i123-i132, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33751087

RESUMO

AIMS: Repetitive conduction patterns in atrial fibrillation (AF) may reflect anatomical structures harbouring preferential conduction paths and indicate the presence of stationary sources for AF. Recently, we demonstrated a novel technique to detect repetitive patterns in high-density contact mapping of AF. As a first step towards repetitive pattern mapping to guide AF ablation, we determined the incidence, prevalence, and trajectories of repetitive conduction patterns in epicardial contact mapping of paroxysmal and persistent AF patients. METHODS AND RESULTS: A 256-channel mapping array was used to record epicardial left and right AF electrograms in persistent AF (persAF, n = 9) and paroxysmal AF (pAF, n = 11) patients. Intervals containing repetitive conduction patterns were detected using recurrence plots. Activation movies, preferential conduction direction, and average activation sequence were used to characterize and classify conduction patterns. Repetitive patterns were identified in 33/40 recordings. Repetitive patterns were more prevalent in pAF compared with persAF [pAF: median 59%, inter-quartile range (41-72) vs. persAF: 39% (0-51), P < 0.01], larger [pAF: = 1.54 (1.15-1.96) vs. persAF: 1.16 (0.74-1.56) cm2, P < 0.001), and more stable [normalized preferentiality (0-1) pAF: 0.38 (0.25-0.50) vs. persAF: 0.23 (0-0.33), P < 0.01]. Most repetitive patterns were peripheral waves (87%), often with conduction block (69%), while breakthroughs (9%) and re-entries (2%) occurred less frequently. CONCLUSION: High-density epicardial contact mapping in AF patients reveals frequent repetitive conduction patterns. In persistent AF patients, repetitive patterns were less frequent, smaller, and more variable than in paroxysmal AF patients. Future research should elucidate whether these patterns can help in finding AF ablation targets.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Incidência , Prevalência
20.
Europace ; 23(12): 1998-2009, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34379760

RESUMO

AIMS: Permanent pacemaker implantation (PPI) still limits the expansion of indications for transcatheter aortic valve implantation (TAVI). Comparison between different systems remains scarce. We aimed to determine the impact of the device type used on post-TAVI PPI. METHODS AND RESULTS: A systematic literature review was performed to identify studies reporting the use of balloon-expandable valve (BEV), self-expandable valve (SEV), and mechanically expandable valve (MEV) and post-TAVI PPI. A network meta-analysis was used to compare TAVI mechanisms (Analysis A) and transcatheter heart valves (Analysis B) with respect to post-TAVI PPI. Analysis A included 40 181 patients with a pooled PPI rate of 19.2% in BEV, 24.7% in SEV, and 34.8% in MEV. Balloon-expandable valve showed lower risk compared to either SEV or MEV and SEV demonstrated lower risk for PPI than MEV. Implantation of BEV was associated with 39% and 62% lower PPI rate with respect to SEV and MEV. Implantation of SEV was associated with 38% lower PPI rate with respect to MEV. Analysis B included 36.143 patients with the lowest pooled PPI rate of 9.6% for Acurate Neo or others, and the highest pooled PPI rate of 34.3% for Lotus. CoreValve, Evolut Portico, and Lotus influenced significantly PPI rate, while Sapien group did not. CONCLUSION: Implantation of BEV and also SEV were associated with lower post-TAVI PPI rate, while MEV were associated with higher post-TAVI PPI. Patient tailored-approach including devices characteristics may help to reduce post-TAVI PPI and to allow TAVI to take the leap towards extension of use in younger patients. PROSPERO NUMBER: CRD42021238671.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Metanálise em Rede , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA