Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 25(6): e14387, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38778567

RESUMO

INTRODUCTION: Radiation dose measurement is an essential part of radiotherapy to verify the correct delivery of doses to patients and ensure patient safety. Recent advancements in radiotherapy technology have highlighted the need for fast and precise dosimeters. Technologies like FLASH radiotherapy and magnetic-resonance linear accelerators (MR-LINAC) demand dosimeters that can meet their unique requirements. One promising solution is the plastic scintillator-based dosimeter with high spatial resolution and real-time dose output. This study explores the feasibility of using the LuSy dosimeter, an in-house developed plastic scintillator dosimeter for dose verification across various radiotherapy techniques, including conformal radiotherapy (CRT), intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and stereotactic radiosurgery (SRS). MATERIALS AND METHODS: A new dosimetry system, comprising a new plastic scintillator as the sensing material, was developed and characterized for radiotherapy beams. Treatment plans were created for conformal radiotherapy, IMRT, VMAT, and SRS and delivered to a phantom. LuSy dosimeter was used to measure the delivered dose for each plan on the surface of the phantom and inside the target volumes. Then, LuSy measurements were compared against an ionization chamber, MOSFET dosimeter, radiochromic films, and dose calculated using the treatment planning system (TPS). RESULTS: For CRT, surface dose measurement by LuSy dosimeter showed a deviation of -5.5% and -5.4% for breast and abdomen treatment from the TPS, respectively. When measuring inside the target volume for IMRT, VMAT, and SRS, the LuSy dosimeter produced a mean deviation of -3.0% from the TPS. Surface dose measurement resulted in higher TPS discrepancies where the deviations for IMRT, VMAT, and SRS were -2.0%, -19.5%, and 16.1%, respectively. CONCLUSION: The LuSy dosimeter was feasible for measuring radiotherapy doses for various treatment techniques. Treatment delivery verification enables early error detection, allowing for safe treatment delivery for radiotherapy patients.


Assuntos
Estudos de Viabilidade , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aceleradores de Partículas/instrumentação , Radiocirurgia/métodos , Dosímetros de Radiação , Radioterapia Conformacional/métodos , Radioterapia Conformacional/instrumentação , Radiometria/métodos , Radiometria/instrumentação , Órgãos em Risco/efeitos da radiação , Neoplasias/radioterapia
2.
Radiat Prot Dosimetry ; 200(3): 264-273, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38123475

RESUMO

The radioluminescent (RL) dosemeter is excellent for real-time radiation measurement and can be used in various applications. A plastic scintillator is often the choice sensor because of its size and tissue equivalency. This study aims to characterise a novel plastic scintillator irradiated with high-energy photon beams. An RL dosimetry system was developed using the plastic scintillator. The RL dosimetry system was irradiated using a linear accelerator to characterise the dose linearity, dose rate, energy dependency and depth dose. The developed system showed a linear response toward the dose and dose rate. An energy dependency factor of 1.06 was observed. Depth dose measurement showed a mean deviation of 1.21% from the treatment planning system. The response and characteristics of the plastic scintillator show that it may be used as an alternative in an RL dosimetry system.


Assuntos
Radiometria , Contagem de Cintilação , Fótons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA