1.
J Anesth ; 2024 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-39214897

RESUMO

PURPOSE: We evaluated the electromyography (EMG)-based neuromuscular monitoring detectability of our novel stimulating electrode attachment method compared to the original Nihon-Kohden (Tokyo, Japan) attachment method. METHODS: This single-center randomized, double-blind, controlled pilot study enrolled 32 patients aged ≥ 18 years, undergoing scheduled laparoscopic surgery. The EMG electrode NM-345Y™ was attached to one forearm using the Nihon-Kohden method (Pattern N-K) and the other forearm using our novel method (Pattern Cross). The allocation to each attachment method was determined post-randomization. In Pattern Cross, the NM-345Y™ was attached such that the line connecting the anode and cathode crosses the ulnar nerve. Patients received 0.9 mg/kg rocuronium after calibration with the forearm in 90-degree supination. Following tracheal intubation, the forearm was positioned in 0-degree pronation. Intraoperatively, 0.2 mg/kg rocuronium was administered if the train-of-four (TOF) count one persisted for 1 min on either side. Post-surgery, the forearm position was returned to 90-degree supination, and rocuronium was antagonized with sugammadex. TOF and post-tetanic count (PTC) were simultaneously measured bilaterally every 15 s and 5 min, respectively, from post-calibration to tracheal extubation. RESULTS: The time to first PTC appearance was significantly shorter by 33 min in the Pattern Cross group than in the Pattern N-K group (95% Confidence interval: 1-66, p = 0.043). Following sugammadex administration, TOF ratios ≥ 0.9 were achieved in 72% of patients in the Pattern N-K group and 97% of those in the Pattern Cross group (p = 0.025). CONCLUSIONS: Crossing the line connecting the anode and cathode with the ulnar nerve stabilizes EMG-based neuromuscular monitoring detectability.

2.
J Anesth ; 37(6): 888-895, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37653275

RESUMO

PURPOSE: The traditionally recommended method for attaching electromyography (EMG) electrodes (NM-345Y™) during EMG-based neuromuscular monitoring developed by Nihon-Kohden may decrease the monitoring accuracy when forearm limb position changes. This study investigated methods for attaching stimulating electrodes that maintained stable EMG-based neuromuscular monitoring accuracy, regardless of forearm limb position changes. METHODS: This single-center experimental study recruited 28 healthy adults from October 2022 to December 2022. The NM-345Y™ was attached to the forearm using three patterns: Pattern N, electrodes attached according to the attachment pattern recommended by Nihon-Kohden; Pattern U, electrodes attached along the ulnar nerve identified using an ultrasound device; Pattern C, electrodes attached where the ulnar nerve crosses the line connecting the centers of the anode and cathode of the stimulating electrodes. The stimulus current values during calibration were measured at three forearm positions for each attachment pattern: supination 90 degrees; pronation 0 degrees; pronation 90 degrees. The differences in stimulus current values caused by forearm position changes were calculated as the difference between values at supination 90 degrees and pronation 0 degrees and between values at supination 90 degrees and pronation 90 degrees. RESULTS: Pattern C showed significantly smaller differences than Pattern N between the stimulus current values at supination 90 degrees and pronation 0 degrees (p = 0.018) and between the stimulus current values at supination 90 degrees and pronation 90 degrees (p = 0.008). CONCLUSION: Crossing the ulnar nerve with the line connecting the anode and cathode of the stimulating electrodes may stabilize EMG-based neuromuscular monitoring accuracy.


Assuntos
Antebraço , Monitoração Neuromuscular , Adulto , Humanos , Antebraço/fisiologia , Eletromiografia , Calibragem , Nervo Ulnar
3.
Cureus ; 16(2): e54024, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38476816

RESUMO

Neuromuscular monitoring is crucial during the administration of neuromuscular blocking agents owing to individual variations in their effects. In electromyography (EMG)-based neuromuscular monitoring using the EMG electrodes (NM-345Y™, Nihon-Kohden Corporation, Tokyo, Japan) following the manufacturer-recommended attachment method, the accuracy of neuromuscular monitoring may be reduced when forearm limb position is changed. We previously devised a novel attachment method for NM-345Y™ stimulating electrodes in adult volunteers to maintain stable monitoring accuracy despite changes in forearm position. Its effectiveness in clinical practice was evaluated by conducting a descriptive study on a 52-year-old woman undergoing laparoscopic uterine surgery. NM-345Y™ electrodes were attached to each forearm following the manufacturer's recommendations (Pattern N) and our novel method (Pattern C). In Pattern C, NM-345Y™ was attached without ultrasound guidance so that the ulnar nerve crossed the line connecting the centers of the anode and cathode of the stimulating electrode. Pattern C exhibited consistent EMG-based monitoring accuracy even with changes in forearm position despite a smaller stimulus current value at calibration. Additionally, Pattern C displayed reliable recovery of the train-of-four (TOF) response after sugammadex administration in the original forearm position, with no observed adverse events. In contrast, Pattern N showed unstable monitoring accuracy after forearm position changes, highlighting the danger of imprecise EMG-based neuromuscular monitoring during the administration of neuromuscular blocking agents. The study's strength lies in identifying Pattern C, where the ulnar nerve crosses the line connecting the anode and cathode, significantly enhancing monitoring accuracy. This novel attachment method holds promise to improve EMG-based neuromuscular monitoring precision in surgery involving forearm limb position changes, although further research is required to assess its utility comprehensively.