Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Struct Heart ; 8(2): 100264, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38481712

RESUMO

Background: Transcatheter mitral valve-in-valve (MViV) replacement has emerged as an alternative to redo mitral valve (MV) surgery for the management of failed bioprosthetic MVs. The degree of cardiac remodeling assessed by echocardiography has been shown to have prognostic implications in degenerative mitral regurgitation patients undergoing MV surgery. The impact of transcatheter MViV in patients with degenerative bioprosthetic MV failure on cardiac remodeling and its associated prognosis remains undescribed. Objectives: The aim of this study is to describe the early anatomic and functional changes of the left-sided chambers and right ventricle by echocardiography posttranscatheter MViV intervention and their impact on mortality outcomes. Additionally, we sought to analyze the outcome of heart failure in bioprosthetic MV failure patients undergoing transcatheter MViV replacement. Methods: We analyzed consecutive patients undergoing MViV intervention for symptomatic bioprosthetic MV failure. Echocardiograms before intervention and within 100 days postintervention were analyzed. A chart review was performed to obtain baseline characteristics, follow-up visits, 30-day heart failure and 1-year all-cause mortality outcomes. Results: A total of 62 patients (mean age 69 ± 13 years, 61% male) were included in the study. Most patients were undergoing MViV intervention for prosthetic mitral stenosis n = 48 (77.4%) and the rest for mitral regurgitation or mixed disease. Compared with baseline, significant reductions were observed in median left atrial volume (LAV; 103 [81-129] ml vs. 95.2 [74.5-117.5] ml, p < 0.01) and mean (SD) left atrial conduit strain (9.1% ± 5.2% vs. 10.8% ± 4.8%, p = 0.039) within 100 days postintervention. Early reduction in right ventricular free wall global longitudinal strain and fractional area change also occurred postintervention. No significant change in left ventricular chamber dimensions or ejection fraction was observed. During the 1-year follow up period, 5 (8%) patients died. While baseline LAV was not associated with 1-year all-cause mortality (OR 0.98 CI 0.95-1.01; p = 0.27), a change in LAV in the follow up period was associated with all-cause mortality at 1 year (OR 1.06 CI 1.01-1.12; p = 0.023). At 30 days postintervention, 65% of patients had an improvement in their New York Heart Association functional class. Conclusion: In this retrospective study of patients undergoing transcatheter MViV intervention for failed bioprosthetic MVs, early reverse remodeling of the left atrium occurs within 100 days postintervention and reduction in LAV is associated with reduced all-cause mortality at 1 year. In addition, there is significant improvement in heart failure symptoms at 30 days following intervention but further investigation into the longitudinal remodeling changes and long-term outcomes is needed.

2.
ASAIO J ; 57(4): 254-61, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21546824

RESUMO

There is a paucity of literature describing the outcomes associated with the use of TandemHeart percutaneous ventricular assist device (PVAD). The literature is limited by analyzing only subsets of patients. We present the clinical outcomes and safety associated with the use of TandemHeart among a series of heterogeneous patients requiring PVAD support. We reviewed the clinical experience, hemodynamic variables, survival outcomes, and complications associated with the implantation of TandemHeart support device among 25 patients presenting to our institution. Indications for PVAD implantation were cardiogenic shock (56%), ST-segment elevation myocardial infarction (STEMI) (20%), postpericardiotomy (16%), and high-risk percutaneous coronary interventions (PCI) or ventricular tachycardia (VT) ablation (8%). TandemHeart was used for an average of 4.8 ± 2.1 days and demonstrated significant hemodynamic improvements (pre- and postimplantation left ventricular ejection fractions were 21.5% ± 15% and 24.5% ± 10.5%, respectively [p = 0.06]). The cardiac index improved from a mean 2.04 ± 075 L/min/m² to 2.45 ± 073 L/min/m² (p = 0.09). The mixed venous oxygen saturation (SVO2) increased from 55.14 ± 13.34 to 66.43 ± 7.43 (p = 0.008) after implantation. TandemHeart was used as a bridge to left ventricular assist device implantation (44%) or recovery (20%). Thirty-six percent of patients died on support or shortly after PVAD removal. Thirty, 90-day, and long-term (>90 days) survival rates were 56%, 52%, and 36%, respectively. Procedure-related complications were reported in 13 patients (56%), and the majority (90%) was related to vascular access (bleeding or pseudoaneurysm). The TandemHeart device is a safe therapeutic option as a bridge-to-recovery or bridge-to-bridge for patients with hemodynamic compromise regardless of the etiology. The favorable hemodynamic profile, postimplantation survival rates, and manageable complications support its use to assist hemodynamic recovery in patients refractory to conventional therapy.


Assuntos
Angioplastia Coronária com Balão/métodos , Coração Auxiliar , Adulto , Idoso , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Infarto do Miocárdio/patologia , Oxigênio/metabolismo , Sistema de Registros , Choque Cardiogênico/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA