RESUMO
OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.
Assuntos
Hematologia , Laboratórios , Humanos , Garantia da Qualidade dos Cuidados de SaúdeRESUMO
Light transmission aggregometry (LTA) is the gold standard for the diagnosis of platelet function disorders (PFDs). The requirement of customized aggregometer, large blood volume, normal platelet count and processing within 4 hours of venipuncture for LTA makes platelet function testing inaccessible to wider population. Flow cytometric platelet activation test (PACT) may overcome these limitations. This study compares the performance of PACT with LTA, characterizes diagnostic patterns of PFDs on PACT and assesses the stability of PACT beyond 4 hours of venipuncture in controls (n = 5) at different temperature conditions. LTA and PACT were performed in 121 healthy controls and 66 patients with suspected PFD. PACT had excellent agreement (kappa = 0.93) with LTA and 94.1% sensitivity, 98.5% specificity. PACT had distinct patterns in Bernard Soulier Syndrome (n = 10), Glanzmann Thrombasthenia (n = 24), δ-granule disorder (n = 7), and other PFDs (n = 12). PACT could assess platelet function in patients (14%) with thrombocytopenia/lipemia wherein LTA was inconclusive. PACT was stable up to 24 hours in samples stored/transported at 2-8â¦C. The results of utility and stability are only valid for the specific markers, agonist concentrations, and conditions investigated in this paper. PACT is a useful modality for the diagnosis of PFD, especially in children, thrombocytopenia cases or in the setup where an aggregometer is not readily available.
Assuntos
Transtornos Plaquetários , Trombocitopenia , Plaquetas , Criança , Humanos , Ativação Plaquetária , Agregação Plaquetária , Testes de Função Plaquetária/métodosRESUMO
Background: The rapidity of spread of COVID-19 infection during the second wave of the pandemic placed tremendous stress on healthcare resources. This study evaluated the effectiveness of a monitored home isolation (HI) program. Methods: In this descriptive longitudinal study, symptomatic patients were screened in the HI clinic and eligible patients were followed up at home using tele-consultation, until recovery or hospitalization. HI failure was defined as need for hospitalization. Factors associated with HI failure were assessed using logistic regression analysis and expressed as odds ratio (OR) with 95% confidence interval (CI). Results: During April and May 2021, 1957 RT-PCR confirmed patients (984 male) with mean (SD) age 40 (13.5) years were enrolled; 93.3% (n = 1825) were successfully managed at home. Of the 132 patients (6.7%) who failed HI, 57 (43.2%) required oxygen therapy and 23 needed intensive care admissions. Overall mortality was 0.4% (7/1957). On adjusted analysis, factors associated with HI failure were age ≥60 years (OR 2.24; 95%CI 1.26-3.99), male gender (OR 2.26; 95%CI 1.44-3.57), subjective reporting of breathing difficulty (OR 3.64; 95%CI 2.08-6.37), history of cough (OR 2.08; 95%CI 1.37-3.17), and higher heart rate (OR 1.04; 95%CI 1.02-1.05). Although patient status (non-healthcare workers), no prior vaccination and ≥2 comorbidities were associated with HI failure on unadjusted analysis, these were non-significant on adjusted analysis. Conclusion: Monitored HI program can be used successfully during a pandemic wave to judicially use scare hospital resources. Older male patients presenting with breathlessness or cough may warrant closer monitoring.
RESUMO
BACKGROUND: The temperature at which filtration takes place has been reported to influence the efficacy of leukoreduction. We aimed to compare the residual leukocyte count (RLC) in red cell units (RCUs) filtered at cold (CT) versus room temperature (RT) and to assess whether this correlates clinically with a difference in the incidence of acute transfusion reactions (ATRs). METHODS AND MATERIALS: In the first part of the study, whole blood units collected were randomly allocated for subsequent filtration at CT and RT, respectively. RLC postfiltration was assessed using flow cytometry. The second part of the study was a nonrandomized clinical trial in which incidence of ATR was compared between RCUs filtered at RT and CT for 6 months each. RESULTS: Thirty-five RCUs each underwent leukofiltration at CT and RT, respectively. The median RLCs in the filtered units at CT and RT were 0.02 × 106 and 0.1 × 106 leukocytes/unit, respectively (p = .0001), with no difference in red blood cell (RBC) recovery (p = .41). During the second part, 3455 RCUs filtered at RT and 3539 RCUs filtered at CT were transfused to patients. The rate of febrile non-hemolytic transfusion reaction (FNHTR) among transfused patients was less with units filtered at CT (1 per 2000 transfusions) in comparison to RT (1 per 588 transfusions). The difference was, however, not significant (p = .14). CONCLUSION: If change in temperature alone can cause significant reduction in leukocytes, then it is a simple way to curtail the rate of this common yet unpleasant reaction and reduce the reaction rate at minimal cost.
Assuntos
Preservação de Sangue , Eritrócitos/citologia , Procedimentos de Redução de Leucócitos , Adulto , Preservação de Sangue/métodos , Temperatura Baixa , Transfusão de Eritrócitos/efeitos adversos , Transfusão de Eritrócitos/métodos , Feminino , Humanos , Procedimentos de Redução de Leucócitos/métodos , Masculino , Reação Transfusional/etiologia , Adulto JovemRESUMO
BACKGROUND: The population need for blood is the total volume required to transfuse all the individuals who need transfusion in a defined population over a defined period. The clinical demand will arise when people with a disease or condition who require transfusion, access healthcare services, and subsequently the clinicians request blood. Essentially, the conversion of need to demand must be maximum to avoid preventable mortality and morbidity. The study estimated the population need for blood in India. METHODS: The methodology included a comprehensive literature review to determine the diseases and conditions requiring transfusion, the population at risk, and prevalence or incidence; and Delphi method to estimate the percentage of people requiring transfusion, and the quantum. RESULTS: The estimated annual population need was 26.2 million units (95% CI; 17.9-38.0) of whole blood to address the need for red cells and other components after the separation process. The need for medical conditions was 11.0 million units (95% CI:8.7-14.7), followed by surgery 6.6 million (95% CI:3.8-10.0), pediatrics 5.0 million (95% CI:3.5-7.0), and obstetrics and gynecology 3.6 million units (95% CI:1.9-6.2). The gap between need and demand which depends upon the access and efficiency of healthcare service provision was estimated at 13 million units. CONCLUSION: The study brings evidence to highlight the gap between need and demand and the importance of addressing it. It cannot be just the responsibility of blood transfusion or health systems, it requires a multi-sectoral approach to address the barriers affecting the conversion of need to clinical demand for blood.
Assuntos
Transfusão de Sangue , Necessidades e Demandas de Serviços de Saúde , Transfusão de Sangue/estatística & dados numéricos , Técnica Delphi , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Necessidades e Demandas de Serviços de Saúde/estatística & dados numéricos , Humanos , ÍndiaRESUMO
Background: Artemisinin-based combination therapy (ACT) is widely used in India and many generic preparations are available. Delayed response has been reported, suggesting inadequate response to artesunate (AS) or genotypic resistance. We designed a prospective observational study to assess the therapeutic response, elaborate pharmacokinetics of AS and identify Plasmodium falciparum kelch 13 (pfk13) propeller gene polymorphisms among hospitalized Indian patients with severe malaria. Methods: We collected blood samples from adult patients with severe P. falciparum or mixed (P. falciparum and P. vivax) malaria on ACT. We calculated the parasite clearance (CL) half-life using the Worldwide Antimalarial Resistance Network (WWARN) online parasite clearance estimator (PCE). We used the liquid chromatography tandem mass spectrophoto-metry method for simultaneous quantification of AS and dihydroartemisinin. We genotyped longitudinally archived DNA samples obtained pre-treatment (day 0) to study the point mutations in the pfk13 propeller domain. Results: A total of 54 patients with malaria were included, with a majority fulfilling the definitions of severe malaria. The median parasite CL slope half-life was estimated to be 6.44 hours (interquartile range 4.79-10.24). AS pharmacokinetics, assessed in 17 patients, were found to be similar in the groups with rapid (<48 hours) and slow CL (>48 hours) of parasites. No known mutations associated with artemisinin resistance in Southeast Asia were observed in our study participants. Conclusions: Slow parasite CL was seen with a high parasite burden without genotypic evidence of AS resistance. There is a need to standardize definitions of therapeutic efficacy of AS in cases of severe malaria.
Assuntos
Antimaláricos , Artesunato , Malária Falciparum , Parasitemia , Plasmodium falciparum , Adolescente , Adulto , Idoso , Resistência a Medicamentos/genética , Feminino , Genes de Protozoários/genética , Hospitalização , Humanos , Índia , Malária Falciparum/sangue , Malária Falciparum/tratamento farmacológico , Malária Falciparum/epidemiologia , Malária Falciparum/parasitologia , Masculino , Pessoa de Meia-Idade , Parasitemia/sangue , Parasitemia/tratamento farmacológico , Parasitemia/epidemiologia , Parasitemia/parasitologia , Projetos Piloto , Plasmodium falciparum/efeitos dos fármacos , Plasmodium falciparum/genética , Polimorfismo Genético/genética , Estudos Prospectivos , Adulto JovemRESUMO
BACKGROUND:: The diagnosis of sepsis is challenging in the absence of a gold standard test. Recent studies have explored the role of neutrophil and monocyte volume, conductivity, and scatter (VCS), derived from automated hematology analyzers, in diagnosing sepsis. We assessed the diagnostic accuracy of VCS parameters in critically ill patients with sepsis. METHODOLOGY:: In this prospective study, VCS parameters, procalcitonin, and C-reactive protein (CRP) were assessed in patients with proven sepsis (cases) and 2 control groups (intensive care unit [ICU] patients without sepsis and healthy blood donors). The diagnostic property of each test was explored by calculating sensitivity, specificity, negative and positive predictive values, and area under the curve (AUC). RESULTS:: The study included 65 patients with sepsis, 58 nonseptic ICU controls, and 98 blood donors. Procalcitonin and CRP were not significantly different ( P > .06) between patients with sepsis and nonseptic patients. Mean (95% confidence interval [CI]) neutrophil volume (MNV) was significantly higher ( P < .001) in patients with sepsis (165.5; 95%CI 161.6-169.4) than in nonseptic (157.3; 95%CI 154.6-160.1) patients and donors (148.9; 95%CI 147.9-150). A similar pattern was seen with mean monocyte volume (MMoV). Neutrophil and monocyte conductivity and scatter parameters were variably associated. The AUC was highest for MMoV (0.74) and lowest for CRP (0.62). Among all parameters, MNV and MMoV had the highest specificity of 85% and 80%, respectively. CONCLUSION:: In critically ill patients with suspected sepsis, VCS parameters may help strengthen the diagnostic probability of sepsis. Future studies may explore the role of serial monitoring of VCS to track response to antimicrobial therapy.
Assuntos
Técnicas Citológicas , Monócitos/citologia , Neutrófilos/citologia , Sepse/diagnóstico , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Proteína C-Reativa/análise , Feminino , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Pró-Calcitonina/sangue , Estudos Prospectivos , Sensibilidade e Especificidade , Sepse/sangue , Adulto JovemRESUMO
External Quality Assurance (EQA) is vital to ensure acceptable analytical quality in medical laboratories. A key component of an EQA scheme is an analytical performance specification (APS) for each measurand that a laboratory can use to assess the extent of deviation of the obtained results from the target value. A consensus conference held in Milan in 2014 has proposed three models to set APS and these can be applied to setting APS for EQA. A goal arising from this conference is the harmonisation of EQA APS between different schemes to deliver consistent quality messages to laboratories irrespective of location and the choice of EQA provider. At this time there are wide differences in the APS used in different EQA schemes for the same measurands. Contributing factors to this variation are that the APS in different schemes are established using different criteria, applied to different types of data (e.g. single data points, multiple data points), used for different goals (e.g. improvement of analytical quality; licensing), and with the aim of eliciting different responses from participants. This paper provides recommendations from the European Federation of Laboratory Medicine (EFLM) Task and Finish Group on Performance Specifications for External Quality Assurance Schemes (TFG-APSEQA) and on clear terminology for EQA APS. The recommended terminology covers six elements required to understand APS: 1) a statement on the EQA material matrix and its commutability; 2) the method used to assign the target value; 3) the data set to which APS are applied; 4) the applicable analytical property being assessed (i.e. total error, bias, imprecision, uncertainty); 5) the rationale for the selection of the APS; and 6) the type of the Milan model(s) used to set the APS. The terminology is required for EQA participants and other interested parties to understand the meaning of meeting or not meeting APS.
Assuntos
Técnicas de Laboratório Clínico/normas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Humanos , Guias de Prática Clínica como AssuntoRESUMO
INTRODUCTION: Blood transfusion is crucial, but low-income and middle-income countries like India face a severe shortage of banked blood. This study focuses on the Empowered Action Group (EAG) states in India, where healthcare is limited, and health outcomes are poor. Our objective was to assess the blood banking infrastructure and access to blood products in these states. METHODS: We used e-Rakht Khosh, an online platform for blood availability data. We collected data on blood bank locations and stocks from 18 January to 9 February 2022 and used ArcGIS to determine the population residing within 30-60-90 min of a blood bank. Availability ratios were calculated by dividing available blood products by population in these catchment areas. Descriptive analysis characterised availability, and statistical tests evaluated differences across states and over the 4-week period. RESULTS: 806 of 824 blood banks reported data on blood stocks. Our analysis showed that 25.72% of the EAG states' population live within 30 min of a blood bank, while 61.45% and 92.46% live within 60 and 90 min, respectively. CONCLUSION: Blood availability rates were low in the EAG states, with only 0.6 units per 1000 people. Additionally, only 61% of the population had access to blood-equipped facilities within an hour. These rates fell below the standards of the Lancet Commission on Global Surgery (15 units per 1000 population) and the WHO (10 donations per 1000 population). The study highlights the challenges in meeting demand for blood in emergencies due to inadequate blood banking infrastructure.
Assuntos
Bancos de Sangue , Acessibilidade aos Serviços de Saúde , Humanos , Índia , Bancos de Sangue/estatística & dados numéricos , Acessibilidade aos Serviços de Saúde/estatística & dados numéricos , Transfusão de Sangue/estatística & dados numéricos , Doadores de Sangue/estatística & dados numéricos , Doadores de Sangue/provisão & distribuição , Análise EspacialRESUMO
BACKGROUND: Low-volume plasma exchange (PLEX) and low-dose steroid improve survival in severe alcoholic hepatitis. We aimed to compare one-year survival of very severe alcoholic hepatitis (VSAH) patients treated with centrifugal PLEX (cPLEX), membrane PLEX (mPLEX) or standard medical treatment (SMT). METHODS: We retrospectively analyzed survival in consecutive VSAH patients treated at our department from November 2017 to September 2021. PLEX patients received low-volume PLEX along with low-dose steroid (tab. prednisolone 10 mg or 20 mg daily). To adjust for baseline differences between the three treatment (cPLEX, mPLEX or SMT) groups, propensity score (PS) matching was done. Acute-on-chronic liver failure (ACLF) was defined as per European Association for the Study of the Liver (EASL). The primary study outcome was one-year transplant-free survival of PS-matched VSAH patients treated with cPLEX compared to SMT. RESULTS: Of 101 PLEX-eligible VSAH patients, 30 patients were treated with cPLEX, 21 with mPLEX and 50 with SMT. On comparing 30 PS-matched patients each in the cPLEX group vs. the SMT group, transplant-free survival in the cPLEX group was 86.7% at one month, 70% at three months and 52.4% at one year and in the SMT group was 33.3% at one month, 23.3% at three months and 16.7% at one year with hazard ratio (HR [95% CI]) in favor of the cPLEX group (0.29 [0.15-0.56], p < 0.001). Total 21 patients each (PS-matched) in cPLEX and mPLEX groups were compared and one-year survival was better with cPLEX (0.33 [0.16-0.69], p = 0.001). The sub-group analysis of VSAH (PS-matched cohort) patients with ACLF also showed better survival with cPLEX compared to SMT (0.38 [0.17-0.83], p = 0.003) and compared to mPLEX (0.43 [0.17-0.95], p = 0.03). CONCLUSION: Better one-year transplant-free survival was noted among PS-matched VSAH patients treated with cPLEX (and low-dose steroid) compared to SMT (without steroid).
RESUMO
In rural settings worldwide, many people live in effective blood deserts without access to any blood transfusion. The traditional system of blood banking is logistically complex and expensive for many resource-restricted settings and demands innovative and multidisciplinary solutions. 17 international experts in medicine, industry, and policy participated in an exploratory process with a 2-day hybrid seminar centred on three promising innovative strategies for blood transfusions in blood deserts: civilian walking blood banks, intraoperative autotransfusion, and drone-based blood delivery. Participant working groups conducted literature reviews and interviews to develop three white papers focused on the current state and knowledge gaps of each innovation. Seminar discussion focused on defining blood deserts and developing innovation-specific implementation agendas with key research and policy priorities for future work. Moving forward, advocates should prioritise the identification of blood deserts and address the context-specific challenges for these innovations to alleviate the ongoing crisis in blood deserts.
Assuntos
Bancos de Sangue , Transfusão de Sangue , Humanos , Políticas , Consenso , População RuralRESUMO
Diagnosis of Hereditary spherocytosis (HS) often requires time-consuming and/or expensive tests. Cryohemolysis test (CHT) is a simple and easy to perform test with high predictive value for HS diagnosis. In this prospective study, we evaluated the diagnostic utility of CHT for the diagnosis of HS. We included 60 suspected HS patients, 18 patients with Autoimmune hemolytic anemia (AIHA) and 120 healthy controls. Among the 60 suspected cases, there were 36 HS cases and 24 with other hemolytic anemias. The mean CHT (%) ± SD for controls, AIHA, other hemolytic anemias, and HS was 6.63 ± 2.79, 6.79 ± 4.36, 6.61 ± 2.76 and 26.7 ± 8.9, respectively. The CHT % was significantly higher in HS group when compared to controls (p = < 0.0001), AIHA (p = < 0.0001) and other hemolytic anemia groups (p = < 0.0001). At a CHT cut off of > 18.3%, the sensitivity, specificity, positive predictive value and negative predictive value for diagnosis of HS in our study were 97.1%, 94.4%, 97.2% and 90.3%, respectively. CHT is a simple and sensitive test for the diagnosis of HS but remains underutilized. The addition of CHT in the diagnostic workup of HS will be very useful, especially in a resource limited setting.
RESUMO
Background: In a prior report, no patient with rodenticidal hepatotoxicity who met Kochi criteria (MELD score ≥36 or baseline INR ≥6 with hepatic encephalopathy) (PMID: 26310868) for urgent liver transplantation survived with medical management alone. Plasma exchange (PLEX) may improve survival in these patients. Objectives: We describe our experience with low-volume PLEX (PLEX-LV) in treating rodenticide ingestion induced hepatotoxicity in children. Methods: From prospectively collected database of rodenticidal hepatotoxicity patients managed as in-patient with department of Hepatology from December 2017 to August 2021, we retrospectively studied outcomes in children (≤18 years). Hepatotoxicity was categorized as acute liver injury (ALI, coagulopathy alone) or acute liver failure (ALF, coagulopathy and encephalopathy). Kochi criteria was used to assess need for urgent liver transplantation. The primary study outcome was one-month survival. Results: Of the 110 rodenticidal hepatotoxicity patients, 32 children (females: 56%; age: 16 [4.7-18] years; median, range) constituted the study patients. The study patients presented 4 (1-8) days after poison consumption (impulsive suicidal intent:31, accidental:1). Twenty children (62%) had ALI [MELD: 18 (8-36)] and 12 (38%) had ALF [MELD: 37 (24-45)].All children received standard medical care, including N-acetyl cysteine; ALF patients also received anti-cerebral edema measures. None of the patient families opted for liver transplantation. Seventeen children (ALI: 6, ALF: 11) were treated with PLEX-LV (3 [1-5] sessions, volume of plasma exchanged per session: 26 [13-38] ml/kg body weight) and peri-procedure low dose prednisolone.At 1 month, 28 of the 32 children (87.5%) were alive (4 ALF patients died). Of 10 children who met Kochi listing criteria for urgent liver transplantation, two children were ineligible for PLEX-LV (due to hemodynamic instability) and of the remaining 8 children treated by PLEX-LV, 6 (75%) survived. Conclusions: PLEX-LV shows promise as an effective non-liver transplant treatment in children with rodenticidal hepatotoxicity.
RESUMO
BACKGROUND: In April 2021, during the peak of the second wave of the COVID-19 pandemic in India, hospitals overflowed with COVID-19 patients, and people hesitated to seek necessary care due to fear of contracting the disease. The UDHAVI helpline was set up by a tertiary care hospital in Vellore with the help of district administration, nongovernmental organizations, and various supporting agencies to provide general information, medical advice, counseling, and logistics support to the community. METHODS: This is a retrospective study of all the phone calls made to the UDHAVI helpline between mid-May and mid-June 2021 during the second wave of the COVID-19 pandemic. The calls were electronically captured as part of the process, and the information was subsequently retrieved and analyzed. RESULTS: In all, 677 calls were received. The lines for general information, medical advice, counseling, and logistics support received 168 (25%), 377 (56%), 15 (2%), and 117 (17%) calls, respectively. Home care kits, oxygen concentrators, and food were delivered by volunteers from local nongovernmental organizations and hospitals. CONCLUSION: We believe the details of our experience would be useful in the preparedness and mobilization of resources in the event of any public health emergency. As a result of this initiative, we propose an integrated partnership model for emergency response to any pandemic situation.
Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Estudos Retrospectivos , Apoio Comunitário , Centros de Atenção TerciáriaRESUMO
BACKGROUND: The emergence of newer variants with the immune escape potential raises concerns about breakthroughs and re-infections resulting in future waves of infection. We examined the protective effect of prior COVID-19 disease and vaccination on infection rates among a cohort of healthcare workers (HCW) in South India during the second wave driven mainly by the delta variant. METHODS AND FINDINGS: Symptomatic HCWs were routinely tested by RT-PCR as per institutional policy. Vaccination was offered to all HCWs in late January, and the details were documented. We set up a non-concurrent cohort to document infection rates and estimated protective efficacy of prior infection and vaccination between 16th Apr to 31st May 2021, using a Cox proportional hazards model with time-varying covariates adjusting for daily incidence. Between June 2020 and May 2021, 2735 (23.9%) of 11,405 HCWs were infected, with 1412, including 32 re-infections, reported during the second wave. 6863 HCWs received two doses of vaccine and 1905 one dose. The protective efficacy of prior infection against symptomatic infection was 86.0% (95% CI 76.7%-91.6%). Vaccination combined with prior infection provided 91.1% (95% CI 84.1%-94.9%) efficacy. In the absence of prior infection, vaccine efficacy against symptomatic infection during the second wave was 31.8% (95% CI 23.5%- 39.1%). CONCLUSIONS: Prior infection provided substantial protection against symptomatic re-infection and severe disease during a delta variant driven second wave in a cohort of health care workers.
Assuntos
COVID-19 , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/uso terapêutico , Pessoal de Saúde , Humanos , Reinfecção , SARS-CoV-2 , VacinaçãoRESUMO
BACKGROUND: An important aspect of ensuring blood safety is the performance of mandatory serological testing for transfusion transmissible infections. The practice of internal quality control (IQC) in blood banks in India is nonuniform, especially the use of third-party materials. Cited reasons are cost, lack of access to control materials, and need for deep-freezers for storage, if prepared in-house. OBJECTIVE: Validation of dried tube specimen (DTS) from HIV-positive plasma as a low-cost, stable material for use as IQC material in blood banks. METHODS: Fresh-frozen plasma (FFP) prepared from four HIV-positive blood-donors were pooled. Equal numbers of seronegative FFPs were pooled. Twenty microlitre aliquots of plasma were made in micro-centrifuge tubes and air-dried overnight at room-temperature. These were stored in 2-8°C refrigerators and tested once weekly for 6 months on multiple platforms with different detection principles: Rapid tests, second-generation enzyme-linked immunosorbent assay (ELISA), fourth-generation ELISA, and fourth-generation Chemiluminescence immunoassay. The protocol was sustained over the next 6 months with decreased testing frequency to study the extended stability of DTS. RESULTS: A total of 139 positive-DTS and 139 negative-DTS were tested with 100% samples showing consistent results on all platforms over 1 year. There was mild deterioration in reaction strengths, which did not interfere in result interpretations. CONCLUSION: Plasma in form of DTS maintained stability when stored at 2-8°C for 1 year. This provides evidence that DTS can be a modality for the production of cost-effective, stable, in-house control material for resource-restricted countries.
RESUMO
This study evaluated and compared the overall equipment effectiveness (OEE), sensitivity, specificity, and efficiency of the high-end hematology analyzers, Yumizen H2500, DxH 800, DxH 900 and XN-9000 (XN-10). A total of 400 anonymized left over's K2 EDTA whole blood samples were analyzed for complete blood count. Of 400 samples, 200 were tested on Yumizen H2500; DxH 800 & DxH 900 while the other 200 were tested on Yumizen H2500 & XN-9000 (XN-10), respectively. The OEE was good and comparable for all the hematology analyzers except DxH 800 showing an average status. The sensitivity (%), specificity (%) and turnaround time (in minutes) for Yumizen H2500, DxH 800, DxH 900 and XN-9000 (XN-10) were 91.67, 61.11 & 103; 66.67, 54.55, & 149; 83.33, 27.27 & 136; 83.33, 28.57 & 122, respectively. Confusion matrix highlights the difficulty for DxH 800 and DxH 900 to discriminate left shift or blasts with large hyper-segmented neutrophils. The flags triggered by Yumizen H2500 were markedly changed to large hyper-segmented neutrophils. Lymphoblast caused more confusion for XN-9000 (XN-10), as it came out to be atypical lymphocytes, or hypersegmented neutrophils. Although comparable in OEE index to other analyzers, the Yumizen H2500 seems to be more reliable in detecting the abnormal cells as it has high sensitivity, specificity and less turnaround time. Thus, analysis adding specificity, sensitivity, and efficiency parameters to the OEE index provides more reliable information of the analyzers.
RESUMO
BACKGROUND: Coated-platelets are sub-population of platelets "coated" with highly procoagulant proteins and phosphatidylserine that sustains thrombin generation. They are produced upon dual agonist stimulation by collagen and thrombin. This study was conducted to assess if there was any difference in the levels of coated-platelets in patients with primary intracranial hemorrhage (PICH) and ischemic stroke due to large artery atherosclerosis (LAA) as compared to healthy controls, and to see if coated-platelet levels had any influence on the hemorrhagic transformation (HT) of ischemic stroke. METHODS: Coated-platelet levels were determined by flow cytometry using fluorescently tagged Annexin V antibody to identify phosphatidylserine exposed on the surface of platelets activated by dual agonists (convulxin and thrombin) in cross-sectional cohort of 75 patients with stroke and 34 controls. RESULTS: Patients with PICH (n = 35) had significantly lower coated-platelets than the controls (adjusted mean ± SE, 21.0 ± 1.9% vs. 36.1 ± 1.7%, p < 0.001), while patients with LAA (n = 30) had significantly higher coated-platelets than controls (adjusted mean ± SE, 51.9 ± 1.5% vs. 36.1 ± 1.7%, p < 0.001). Patients with subsequent HT of ischemic stroke (n = 10) had significantly lower coated-platelet levels at admission compared to those without HT (adjusted mean ± SE, 18.1 ± 2.6% vs. 51.9 ± 1.5%, p < 0.001). CONCLUSIONS: Coated-platelet levels are significantly different in patients with hemorrhagic and ischemic stroke as compared with controls. Lower levels of coated-platelets measured by flow cytometry may be earliest predictor of subsequent HT in patients with ischemic stroke even before the radiological changes suggestive of HT are visualized.
Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Trombose , Biomarcadores/metabolismo , Plaquetas/metabolismo , Estudos Transversais , Citometria de Fluxo , Humanos , AVC Isquêmico/diagnóstico , Fenótipo , Fosfatidilserinas/metabolismo , Ativação Plaquetária , Acidente Vascular Cerebral/diagnóstico , Trombina/metabolismo , Trombose/metabolismoRESUMO
INTRODUCTION: Type 3 von Willebrand disease (VWD) is a rare autosomal recessive disorder characterized by undetectable von Willebrand Antigen (VWF:Ag). Carriers of type 3 VWD carry one null allele and have von Willebrand factor (VWF) at about 50% of normal. The aim of this study was to characterize type 3 VWD carriers and to study the role of Platelet Function Analyzer (PFA-200) in this cohort. METHODS: This was a cross-sectional study where data were collected from carriers (parents/offspring) of type 3 VWD patients and evaluated with activated partial thromboplastin time, factor VIII, blood group, ristocetin cofactor assay (VWF:RCo), VWF:Ag, and closure time on PFA-200 with collagen/epinephrine (COL/EPI), and collagen/ADP (COL/ADP). RESULTS: One hundred carriers were included in the study of which 85 were included for PFA-200 analysis. The mean (SD) of VWF:Ag (IU/ml) and VWF:RCo (IU/ml) was 0.63 (0.24) and 0.61 (0.26), respectively. Among the 100 carriers, based on VWF levels (VWF:Ag and/or VWF:RCo) and bleeding history, there were 7 type 1 VWD, 10 type 2 VWD, 25 borderline VWF (0.30-0.50 IU/ml and no bleeding), and 58 normal VWF (>0.50 IU/ml). PFA-200 was prolonged in 71% of the carriers, all carriers with type 1 and type 2 VWD phenotype, 80% carriers with borderline VWF, and 59% with normal VWF. COL/EPI was more sensitive than COL/ADP and showed better correlation with VWF parameters than COL/ADP. CONCLUSION: Carriers of type 3 VWD can have a variable laboratory phenotype. PFA-200 showed good sensitivity among the carriers at VWF levels <0.50 IU/ml.
Assuntos
Doença de von Willebrand Tipo 3 , Doenças de von Willebrand , Difosfato de Adenosina , Colágeno , Estudos Transversais , Humanos , Doença de von Willebrand Tipo 3/diagnóstico , Doença de von Willebrand Tipo 3/genética , Doenças de von Willebrand/diagnóstico , Doenças de von Willebrand/genética , Fator de von Willebrand/análise , Fator de von Willebrand/genéticaRESUMO
BACKGROUND: Estimating the clinical demand for blood and components arising in a health facility is crucial to ensure timely availability of blood. This study aims to estimate disease-specific clinical demand, supply and utilization of whole blood and components in India. METHODS: We conducted a national level cross-sectional study in five randomly selected states from five regions of the country. We included 251 public and private facilities representing primary, secondary and tertiary care facilities. We collected annual disease-specific demand, supply and utilization of blood and components using a structured tool. We estimated the national demand by extrapolating the study data (demand and beds) to the total number of estimated beds in the country. FINDINGS: According to the study, the total clinical demand of 251 health facilities with 51,562 beds was 474,627 whole blood units. Based on this, the clinical demand for India was estimated at 14·6 million whole blood units (95 CI: 14·59-14·62), an equivalent of 36·3 donations per 1,000 eligible populations, which will address whole blood and component requirement. The medicine specialty accounted for 6·0 million units (41·2%), followed by surgery 4·1 million (27·9%), obstetrics and gynecology 3·3 million (22·4%) and pediatrics 1·2 million (8·5%) units. The supply was 93% which is equivalent to 33·8 donations against the demand. CONCLUSION: The study indicated a demand and supply gap of 2.5 donations per 1,000 eligible persons which is around one million units. The gap emphasises the need for sustained and concerted efforts from all stakeholders and for increasing the awareness about repeat voluntary non-remunerated blood donation (VNRBD); optimizing the availability of blood components through efficient blood component separation units; promoting modern principles of patient blood management and strengthening capacities of human resources in the blood transfusion system in India.