Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 147
Filtrar
1.
J Nucl Cardiol ; 30(5): 2043-2053, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37012523

RESUMO

BACKGROUND: Myocardial flow reserve (MFR) and the extent of myocardial ischemia identify patients at high risk of major adverse cardiovascular events (MACEs). Associations between positron emission tomography (PET)-assessed extent of ischemia, MFR, and MACEs is unclear. METHOD: Overall, 640 consecutive patients with suspected or known coronary artery disease undergoing 13N-ammonia myocardial perfusion PET were followed-up for MACEs. Patients were categorized into three groups based on myocardial ischemia severity: Group I (n = 335), minimal (myocardial ischemia < 5%); Group II (n = 150), mild (5-10%); and Group III (n = 155), moderate-to-severe (> 10%). RESULTS: Cardiovascular death and MACEs occurred in 17 (3%) and 93 (15%) patients, respectively. Following statistical adjustment for confounding factors, impaired MFR (global MFR < 2.0) was revealed as an independent predictor of MACEs in Groups I (hazard ratio [HR], 2.89; 95% confidence interval [CI], 1.48-5.64; P = 0.002) and II (HR, 3.40; 95% CI 1.37-8.41; P = 0.008) but was not significant in Group III (HR, 1.15; 95% CI 0.59-2.26; P = 0.67), with a significant interaction (P < 0.0001) between the extent of myocardial ischemia and MFR. CONCLUSION: Impaired MFR was significantly associated with increased risk of MACEs in patients with ≤ 10% myocardial ischemia but not with those having > 10% ischemia, allowing a clinically effective risk stratification.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Amônia , Imagem de Perfusão do Miocárdio/métodos , Isquemia Miocárdica/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Isquemia , Circulação Coronária
2.
J Nucl Cardiol ; 28(1): 128-136, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-30815835

RESUMO

BACKGROUND: We aimed to determine the correlation between phase analysis, reflecting the heterogeneity of perfusion defects, and the dyssynchrony of the left ventricle wall motion, and adverse cardiac events in cardiac sarcoidosis (CS) patients. METHODS: Fifty-seven consecutive patients with diagnosed CS (64 [IQR 55-71] years old, 14 males), who underwent 18F-FDG PET/CT and ECG-gated SPECT, were studied. FDG PET was analysed to measure cardiac metabolic volume (CMV), and total lesion glycolysis (TLG). The SPECT findings, such as LVEF, Summed Rest Score (SRS), bandwidth (BW) were evaluated. RESULTS: The median of BW was 56° (IQR 40-95). BW showed a strong inverse correlation with LVEF (r = - 0.60, P < 0.0001), and positive correlation with SRS (r = 0.82, P < 0.0001). However, there were no significant correlations between BW and CMV or TLG. The Kaplan-Meier curves revealed a significantly higher rate of MACE in the high BW group (BW > 56°) than the low BW group (BW ≤ 56°) (15.1%/years vs. 4.4%/years, P = 0.025). In multivariable analysis, BW was a significant independent predictor of MACE (P = 0.015). CONCLUSION: Phase analysis on gated SPECT was a significant and independent predictor of MACE in patients with CS.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Sarcoidose/diagnóstico por imagem , Sarcoidose/fisiopatologia , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Valor Preditivo dos Testes , Prognóstico , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Volume Sistólico/fisiologia
3.
J Nucl Cardiol ; 28(4): 1745-1756, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31605274

RESUMO

BACKGROUND: Sarcoidosis is a multisystemic disorder of unknown cause characterized by immune granuloma formation in the involved organs. Few studies have reported on the myocardial perfusion changes by immunosuppression therapy in cardiac sarcoidosis (CS). Additionally, the relationship between myocardial perfusion changes and prognosis is unknown. Therefore, this study aimed to clarify myocardial perfusion recovery after steroid therapy and its prognostic value for major adverse cardiac events (MACE) in patients with CS. METHODS AND RESULTS: Thirty-eight consecutive patients with CS {median age, 63 [interquartile range (IQR) 51-68] years; 10 men} underwent both 18F-fluorodeoxyglucose positron emission tomography/computed tomography (CT) and electrocardiography-gated single-photon emission CT (SPECT) pre- and post-steroid therapy. Patients with improved or preserved myocardial perfusion after post-therapy were defined as the recovery group and those with worsened myocardial perfusion as the non-recovery group. Twenty-six patients (68%) were categorized as the recovery group. MACE occurred in eight patients. The Kaplan-Meier curves revealed a significantly higher rate of MACE in the non-recovery group (17.4%/y vs 2.9%/y, P = 0.007). CONCLUSIONS: Myocardial perfusion was recovered by steroid therapy in 61% and preserved in 8% of patients. Myocardial perfusion recovery after steroid therapy was significantly associated with a low incidence of MACE.


Assuntos
Circulação Coronária/fisiologia , Glucocorticoides/uso terapêutico , Cardiopatias/tratamento farmacológico , Cardiopatias/fisiopatologia , Prednisolona/uso terapêutico , Sarcoidose/tratamento farmacológico , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Eletrocardiografia , Feminino , Fluordesoxiglucose F18 , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Recuperação de Função Fisiológica/fisiologia , Estudos Retrospectivos , Sarcoidose/diagnóstico por imagem , Sarcoidose/fisiopatologia , Volume Sistólico/fisiologia
4.
J Nucl Cardiol ; 28(4): 1477-1486, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31452085

RESUMO

BACKGROUND: We compared quantification of MBF and myocardial flow reserve (MFR) with a 99mTc-sestamibi CZT-SPECT to 15O-water PET. METHODS: SPECT MBF for thirty patients in the WATERDAY study was re-analyzed by QPET software with motion correction and optimal placement of the arterial input function. 15O-water PET MBF was re-quantified using dedicated software. Inter-operator variability was assessed using repeatability coefficients (RPC). RESULTS: Significant correlations were observed between global (r = 0.91, P < 0.001) and regional MBF (r = 0.86, P < 0.001) with SPECT compared to PET. Global MBF (rest 0.95 vs 1.05 ml/min/g, P = 0.07; stress 2.62 vs 2.68 mL/min/g, P = 0.17) and MFR (2.65 vs 2.75, P = 0.86) were similar between SPECT and PET. Rest (0.81 vs 0.98 mL/min/g, P = 0.03) and stress MBF (1.98 vs 2.61 mL/min/g, P = 0.01) in right coronary artery (RCA) were lower with SPECT compared to PET. However, MFR in the RCA territory was similar (2.54 vs 2.77, P = 0.21). The SPECT-PET RPC for global MBFs and MFR were 0.95 mL/min/g and 0.94, with inter-observer RPC of 0.59 mL/min/g and 0.74, respectively. CONCLUSIONS: MBF and MFR derived from CZT-SPECT with motion correction and optimal placement of the arterial input function showed good agreement with 15O-water PET, as well as low inter-operator variability.


Assuntos
Cádmio , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único , Zinco , Idoso , Algoritmos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Variações Dependentes do Observador , Radioisótopos de Oxigênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Tecnécio Tc 99m Sestamibi , Água
5.
J Nucl Cardiol ; 28(4): 1718-1725, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31559536

RESUMO

BACKGROUND: We tested the repeatability of myocardial blood flow (MBF) quantified using 82Rb with and without motion correction (MC) and with arterial input functions estimated from left ventricle (LV) and atrium (LA). METHODS: Twenty-one patients referred for clinical 82Rb PET/CT underwent repeated rest scans in a single imaging session. Global MBF was quantified using three different assessments by two operators: (1) automatic processing without MC and LV arterial input function (AIF), (2) with MC and LV-AIF, and (3) with MC and LA-AIF. Inter-scan and inter-operator repeatability were tested using coefficient of variation (CV). RESULTS: MC with LV-AIF did not change MBF (no MC: 1.01 ± 0.30 mL/min/g vs MC with LV-AIF: 1.01 ± 0.29, P = 0.70), whereas MC with LA-AIF showed significantly lower MBF assessments (0.95 ± 0.28 mL/min/g, P = 0.0006). We report significant improvement for test-retest reproducibility for global MBF following MC (CV; No MC: 16.0, MC (LV-AIF): 9.2, MC (LA-AIF): 8.8). Good inter-operator repeatability was observed for LV-AIF (CV = 4.7) and LA-AIF (CV = 5.6) for global MBF assessments. CONCLUSIONS: MC significantly improved the test-retest repeatability between operators and between scans. MBF obtained after MC with LV-AIF were comparable, whereas MBFs after MC and LA-AIF were significantly reduced.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Processamento de Imagem Assistida por Computador , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Vasos Coronários , Feminino , Humanos , Masculino , Movimentos dos Órgãos , Reprodutibilidade dos Testes , Radioisótopos de Rubídio
6.
J Nucl Cardiol ; 28(5): 2141-2148, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-31820409

RESUMO

BACKGROUND: 18F-fluoromisonidazole (FMISO) is a hypoxia positron emission tomography (PET) tracer. Here, we evaluated cardiac and extra-cardiac sarcoidosis using both FMISO and 18F-fluorodeoxyglucose (FDG) PET/CT in a prospective cohort of patients with sarcoidosis. METHODS: Ten consecutive sarcoidosis patients with suspected cardiac involvement were prospectively enrolled. Each patient fasted overnight (for ≥ 18 hours) preceded by a low-carbohydrate diet before FDG PET/CT but not given special dietary instructions before the FMISO PET/CT scan. We visually and semiquantitatively assessed the uptakes of FMISO and FDG using the maximal standardized uptake value (SUVmax). The metabolic volume (MV) of FDG was calculated as the volume within the boundary determined by the threshold (mean SUV of blood pool × 1.5). RESULTS: Nine patients showed focal FDG uptake in the myocardium and were diagnosed with cardiac sarcoidosis. Among the patients with extra-cardiac lesions, FDG uptake was seen in 8 lymph nodes and 3 lung lesions. FMISO uptake was seen in the 7 cardiac (77.8%) and 6 extra-cardiac (54.5%) lesions. None of the patients showed physiological FMISO uptake in the myocardium. The SUVmax values of the lesions with FMISO uptake were higher than those of the lesions without FMISO uptake in both the cardiac (SUVmax: 9.9, IQR: 8.4-10.0 vs 7.3, IQR: 6.3-8.2) and non-cardiac lesions (SUVmax: 17.6, IQR: 14.5-19.3 vs 6.1, IQR: 5.9-6.2; P = 0.006). The MV values of the lesions with FMISO uptake were significantly higher than those of the lesions without FMISO uptake (111.3, IQR: 78.3-135.7 vs 6.4, IQR: 1.9-23.3; P = 0.0009). CONCLUSIONS: FMISO showed no physiological myocardial uptake and did not require special preparation. FMISO PET has the potential to detect hypoxic lesions in patients with sarcoidosis.


Assuntos
Hipóxia/complicações , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Sarcoidose/complicações , Idoso , Feminino , Fluordesoxiglucose F18/administração & dosagem , Fluordesoxiglucose F18/uso terapêutico , Humanos , Hipóxia/diagnóstico por imagem , Japão , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/estatística & dados numéricos , Estudos Prospectivos , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico , Sarcoidose/diagnóstico por imagem
7.
Heart Vessels ; 36(7): 917-923, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33484293

RESUMO

Endothelin-1 contributes to the constrictor response of the coronary arteries in patients with ischemia with normal coronary arteries. There is thus increasing evidence that endothelin-1 plays a role in coronary microvascular dysfunction (CMD). We investigated whether elevated endothelin-1 is associated with CMD in patients with coronary artery disease (CAD). We prospectively studied 49 consecutive CAD patients with 1- or 2-vessel disease (age 71 ± 10 years, 43 males). Myocardial blood flow (MBF) was measured by 15O-water PET/CT at rest and during stress, and the coronary flow reserve (CFR) was calculated by dividing the stress MBF by the rest MBF. A CFR of less than 2.0 in non-obstructive regions was defined as a marker of CMD. Eighteen out of 49 (37%) CAD patients had CMD. Endothelin-1 in patients with CMD was significantly higher than in those without CMD (2.27 ± 0.81 vs. 1.64 ± 0.48 pg/mL, P = 0.001). Accordingly, univariate ROC analysis showed that the continuous endothelin-1 levels significantly discriminated between the presence and absence of CMD (area under the curve = 0.746 [95%CI 0.592-0.899]). The dichotomous treatment of elevated endothelin-1 as 1.961 pg/mL or more yielded the optimal discriminatory capacity, with a sensitivity of 72.2% and a specificity of 71.0%. High endothelin-1 was still a significant predictor of CMD after adjusting for diabetes mellitus (odds ratio = 6.64 [1.75-25.22], P = 0.005). Endothelin-1 is associated with CMD in non-obstructive territories in patients with CAD, suggesting that endothelin-1 is a potential target for treating CMD in CAD patients.


Assuntos
Doença da Artéria Coronariana/sangue , Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Endotelina-1/sangue , Microcirculação/fisiologia , Idoso , Biomarcadores/sangue , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prognóstico , Estudos Retrospectivos
8.
Eur J Nucl Med Mol Imaging ; 47(13): 3084-3093, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32372228

RESUMO

PURPOSE: Quantification of myocardial blood flow (MBF) has become central in the clinical application of Rubidium-82 (82Rb) PET myocardial perfusion scans. Current recommendations suggest injections of 1100-1500 MBq of 82Rb in bolus form, which poses a potential risk of PET system saturation on most 3D PET/CT systems currently being used. We aimed to evaluate the frequency and impact of PET system saturation and to test the potential use of a half-dose acquisition protocol. METHODS: This study comprised 20 patients who underwent repeated rest scans in a single imaging session, one employing a full-dose (FD), and the other scan a half-dose (HfD) protocol. Datasets were evaluated for saturation based on visual assessments of input functions and sinograms. We compared FD and HfD MBF measurements using Bland-Altman plots, coefficients of variation (CV), and paired t tests. A correction factor permitting serial analyses using FD/HfD imaging protocols was obtained using only the datasets without saturation. RESULTS: A dose reduction of 47% was reported for the HfD protocol (FD, 1247 ± 196 MBq; HfD, 662 ± 115 MBq). Saturation effects were observed in 4/20 (20%) FD scans, with none observed in the 20 HfD scans. Assessment of MBFs for FD and HfD protocols revealed bias in the MBF assessments of 0.09 ml/g/min (global MBF, FD = 1.03 ± 0.29 vs HfD = 0.94 ± 0.22 ml/g/min (p = 0.001)). Exclusion of patients with visually identified saturation effects (N = 4) reduced the bias to 0.05 ml/g/min (global MBF, FD = 0.97 ± 0.28 vs HfD = 0.92 ± 0.23 ml/g/min (p = 0.02)). From the datasets without saturation effect, it was possible to generate a bias-correction: Corrected MBFHfD = 1.09*MBFHfD-0.03 ml/g/min. MBFFD and MBFHfD did not differ following the bias correction (MBFFD = 0.97 ± 0.28, MBFHfD,corrected = 0.98 ± 0.25 ml/g/min, p = 0.77). CONCLUSION: Saturation effects can be problematic in 82Rb MBF studies using the recommended FD protocols for 3D PET/CT scanners. The use of HfD protocol eliminates the risks of saturation and should be used instead of clinical protocols to avoid erroneous results.


Assuntos
Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Circulação Coronária , Humanos , Tomografia por Emissão de Pósitrons , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
9.
Eur J Nucl Med Mol Imaging ; 47(8): 1833-1842, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31781832

RESUMO

PURPOSE: 18F-fluoromisonidazole (18F-FMISO) is the most widely used positron emission tomography (PET) tracer for imaging tumor hypoxia. Previous reports suggested that the time from injection to the scan may affect the assessment of 18F-FMISO uptake. Herein, we directly compared the images at 2 h and 4 h after a single injection of 18F-FMISO. METHODS: Twenty-three patients with or suspected of having a brain tumor were scanned twice at 2 and 4 h following an intravenous injection of 18F-FMISO. We estimated the mean standardized uptake value (SUV) of the gray matter and white matter and the gray-to-white matter ratio in the background brain tissue from the two scans. We also performed a semi-quantitative analysis using the SUVmax and maximum tumor-to-normal ratio (TNR) for the tumor. RESULTS: At 2 h, the SUVmean of gray matter was significantly higher than that of white matter (median 1.23, interquartile range (IQR) 1.10-1.32 vs. 1.04, IQR 0.95-1.16, p < 0.0001), whereas at 4 h, it significantly decreased to approach that of the white matter (1.10, IQR 1.00-1.23 vs. 1.02, IQR 0.93-1.13, p = NS). The gray-to-white matter ratio thus significantly declined from 1.17 (IQR 1.14-1.19) to 1.09 (IQR 1.07-1.10) (p < 0.0001). All 7 patients with glioblastoma showed significant increases in the SUVmax (2.20, IQR 1.67-3.32 at 2 h vs. 2.65, IQR 1.74-4.41 at 4 h, p = 0.016) and the TNR (1.75, IQR 1.40-2.38 at 2 h vs. 2.34, IQR 1.67-3.60 at 4 h, p = 0.016). CONCLUSION: In the assessment of hypoxic tumors, 18F-FMISO PET for hypoxia imaging should be obtained at 4 h rather than 2 h after the injection.


Assuntos
Glioblastoma , Misonidazol , Glioblastoma/diagnóstico por imagem , Humanos , Hipóxia/diagnóstico por imagem , Misonidazol/análogos & derivados , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
10.
BMC Cancer ; 20(1): 227, 2020 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-32183748

RESUMO

BACKGROUND: As the number of PET/CT scanners increases and FDG PET/CT becomes a common imaging modality for oncology, the demands for automated detection systems on artificial intelligence (AI) to prevent human oversight and misdiagnosis are rapidly growing. We aimed to develop a convolutional neural network (CNN)-based system that can classify whole-body FDG PET as 1) benign, 2) malignant or 3) equivocal. METHODS: This retrospective study investigated 3485 sequential patients with malignant or suspected malignant disease, who underwent whole-body FDG PET/CT at our institute. All the cases were classified into the 3 categories by a nuclear medicine physician. A residual network (ResNet)-based CNN architecture was built for classifying patients into the 3 categories. In addition, we performed a region-based analysis of CNN (head-and-neck, chest, abdomen, and pelvic region). RESULTS: There were 1280 (37%), 1450 (42%), and 755 (22%) patients classified as benign, malignant and equivocal, respectively. In the patient-based analysis, CNN predicted benign, malignant and equivocal images with 99.4, 99.4, and 87.5% accuracy, respectively. In region-based analysis, the prediction was correct with the probability of 97.3% (head-and-neck), 96.6% (chest), 92.8% (abdomen) and 99.6% (pelvic region), respectively. CONCLUSION: The CNN-based system reliably classified FDG PET images into 3 categories, indicating that it could be helpful for physicians as a double-checking system to prevent oversight and misdiagnosis.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Redes Neurais de Computação , Neoplasias Pélvicas/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/tendências , Neoplasias Torácicas/diagnóstico por imagem , Neoplasias Abdominais/classificação , Adulto , Idoso , Idoso de 80 Anos ou mais , Inteligência Artificial , Feminino , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/classificação , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pélvicas/classificação , Neoplasias Torácicas/classificação , Adulto Jovem
11.
J Nucl Cardiol ; 27(6): 2135-2143, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-30610523

RESUMO

BACKGROUND: The aim of this study was to determine whether right ventricle (RV) 18F-fluorodeoxyglucose (FDG) uptake can predict positive findings of endomyocardial biopsy (EMB) in patients with cardiac sarcoidosis (CS). METHODS: 70 consecutive patients with clinically diagnosed CS who had undergone FDG PET were registered in the present study. Patients without EMB (n = 42) were excluded. Ultimately, 28 patients were studied. EMB samples were obtained from the RV septum. We evaluated the FDG uptake on six segments (RV, left ventricle anterior, septal, lateral, inferior, and apex). RESULTS: Positive EMB was found in six patients (21%). Patients were divided into two groups according to positive (n = 12 [43%]) or negative (n = 16 [57%]) RV FDG uptake. Patients with positive RV FDG uptake had a significantly higher frequency of positive EMB than those without (42% vs. 6%, P = 0.024). On the other hand, there was no EMB-predictive value for the FDG uptakes in the other five segments, the cardiac metabolic volume, total lesion glycolysis, left ventricular ejection fraction, or any electrocardiogram findings. CONCLUSIONS: FDG uptake of the RV but no other heart segment was associated with positive EMB in CS patients. The presence of RV FDG uptake could improve the rate of positive EMB up to 42% in patients with CS.


Assuntos
Biópsia , Cardiomiopatias/diagnóstico por imagem , Fluordesoxiglucose F18 , Ventrículos do Coração/diagnóstico por imagem , Miocárdio/patologia , Tomografia por Emissão de Pósitrons/métodos , Sarcoidose/diagnóstico por imagem , Idoso , Ecocardiografia , Feminino , Fluoroscopia , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
12.
J Nucl Cardiol ; 27(4): 1118-1125, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-29270771

RESUMO

BACKGROUND: 11C-hydroxyephedrine (HED) PET has been used to evaluate the myocardial sympathetic nervous system (SNS). Here we sought to establish a simultaneous approach for quantifying both myocardial blood flow (MBF) and the SNS from a single HED PET scan. METHODS: Ten controls and 13 patients with suspected cardiac disease were enrolled. The inflow rate of 11C-HED (K1) was obtained using a one-tissue-compartment model. We compared this rate with the MBF derived from 15O-H2O PET. In the controls, the relationship between K1 from 11C-HED PET and the MBF from 15O-H2O PET was linked by the Renkin-Crone model. RESULTS: The relationship between K1 from 11C-HED PET and the MBF from 15O-H2O PET from the controls' data was approximated as follows: K1  =  (1 - 0.891 * exp(- 0.146/MBF)) * MBF. In the validation set, the correlation coefficient demonstrated a significantly high relationship for both the whole left ventricle (r = 0.95, P < 0.001) and three coronary territories (left anterior descending artery: r = 0.96, left circumflex artery: r = 0.81, right coronary artery: r =  0.86; P < 0.001, respectively). CONCLUSION: 11C-HED can simultaneously estimate MBF and sympathetic nervous function without requiring an additional MBF scan for assessing mismatch areas between MBF and SNS.


Assuntos
Circulação Coronária/fisiologia , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Adulto , Radioisótopos de Carbono , Efedrina/análogos & derivados , Humanos , Radioisótopos de Oxigênio , Estudos Prospectivos , Sistema Nervoso Simpático/fisiologia , Água
13.
J Nucl Cardiol ; 27(1): 28-37, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31172386

RESUMO

INTRODUCTION: Assessment of myocardial uptake of Tc-99m-pyrophosphate (Tc-99m PYP) is pivotal in distinguishing transthyretin-associated cardiac amyloidosis (ATTR) from light chain amyloid (AL). It is often difficult to differentiate myocardial uptake from blood pool radioactivity with planar imaging or SPECT. We studied whether simultaneous dual-isotope Tc-99m PYP/Tl-201 SPECT improves assessment of Tc-99m PYP uptake compared to single-isotope SPECT. METHODS: Simultaneous Tc-99m PYP/Tl-201 dual-isotope SPECT was acquired in 112 patients studied for possible cardiac amyloidosis. Visual interpretation was performed by two observers on single-isotope followed by dual-isotope SPECT. Heart-to-contralateral lung ratio (H/CL) of myocardial counts quantified by single-isotope and dual-isotope SPECT was compared between ATTR, AL, and no amyloidosis groups. RESULTS: In 112 patients (39 ATTR and 26 AL patients, and 47 no amyloidosis), a lower proportion of no amyloidosis and AL patients were classified visually as equivocal with dual-isotope SPECT compared to single-isotope SPECT (2% vs 19%, P = 0.02 and 8% vs 35%, P = 0.04, respectively). H/CL measurements with single-isotope and dual-isotope were lower in AL and no amyloidosis patients vs ATTR patients (P < 0.05). Interobserver agreement of visual assessment was improved with dual-isotope SPECT (P = 0.03). AUCs for detection of ATTR by visual assessment and H/CL quantification were higher with dual-isotope (0.94 and 0.95, respectively) compared to single-isotope SPECT (0.84, P = 0.001 and 0.92, P = 0.02). CONCLUSION: Tc-99m PYP/Tl-201 SPECT improves visual differentiation of ATTR and AL amyloidosis compared to single-isotope SPECT. Visual assessment and H/CL quantitation with dual-isotope SPECT provide similar discrimination between patients with ATTR and AL amyloidosis.


Assuntos
Amiloidose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Compostos Radiofarmacêuticos , Pirofosfato de Tecnécio Tc 99m , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Radiographics ; 40(7): E29-E32, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33136484

RESUMO

Editor's Note.- Articles in the RadioGraphics Update section provide current knowledge to supplement or update information found in full-length articles previously published in RadioGraphics. Authors of the previously published article provide a brief synopsis that emphasizes important new information such as technologic advances, revised imaging protocols, new clinical guidelines involving imaging, or updated classification schemes. Articles in this section are published solely online and are linked to the original article.


Assuntos
Doenças Cardiovasculares , Vasos Coronários , Aorta , Diagnóstico por Imagem , Humanos , Imunoglobulina G
15.
Eur J Nucl Med Mol Imaging ; 46(6): 1240-1247, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30327855

RESUMO

PURPOSE: 18F-fluorodeoxyglocose positron emission tomography (FDG PET) plays a significant role in the diagnosis of cardiac sarcoidosis (CS). Texture analysis is a group of computational methods for evaluating the inhomogeneity among adjacent pixels or voxels. We investigated whether texture analysis applied to myocardial FDG uptake has diagnostic value in patients with CS. METHODS: Thirty-seven CS patients (CS group), and 52 patients who underwent FDG PET/CT to detect malignant tumors with any FDG cardiac uptake (non-CS group) were studied. A total of 36 texture features from the histogram, gray-level co-occurrence matrix (GLCM), gray-level run length matrix (GLRLM), gray-level zone size matrix (GLZSM) and neighborhood gray-level difference matrix (NGLDM), were computed using polar map images. First, the inter-operator and inter-scan reproducibility of the texture features of the CS group were evaluated. Then, texture features of the patients with CS were compared to those without CS lesions. RESULTS: Twenty-eight of the 36 texture features showed high inter-operator reproducibility with intraclass correlation coefficients (ICCs) over 0.80. In addition, 17 of the 36 showed high inter-scan reproducibility with ICCs over 0.80. The SUVmax showed no difference between the CS and non-CS group [7.36 ± 2.77 vs. 8.78 ± 4.65, p = 0.45, area under the curve (AUC) = 0.60]. By contrast, 16 of the 36 texture features could distinguish CS from non-CS grsoup with AUC > 0.80. Multivariate logistic regression analysis after hierarchical clustering concluded that long-run emphasis (LRE; P = 0.0004) and short-run low gray-level emphasis (SRLGE; P = 0.016) were significant independent factors that could distinguish between the CS and non-CS groups. Specifically, LRE was significantly higher in CS than in non-CS (30.1 ± 25.4 vs. 11.4 ± 4.6, P < 0.0001), with high diagnostic ability (AUC = 0.91), and had high inter-operator reproducibility (ICC = 0.98). CONCLUSIONS: The texture analysis had high inter-operator and high inter-scan reproducibility. Some of texture features showed higher diagnostic value than SUVmax for CS diagnosis. Therefore, texture analysis may have a role in semi-automated systems for diagnosing CS.


Assuntos
Diagnóstico por Computador/métodos , Fluordesoxiglucose F18/análise , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sarcoidose/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Área Sob a Curva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
J Nucl Cardiol ; 26(5): 1602-1616, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-29858766

RESUMO

Takotsubo cardiomyopathy (TC) is a syndrome of transient left ventricular (LV) dysfunction mimicking acute coronary syndrome. Although the mechanisms underlying the occurrence of TC are unknown, several imaging techniques contribute to its diagnosis. Here we review the current knowledge about TC, in particular, the pathophysiology and the role of imaging including nuclear cardiovascular medicine.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Imagem Multimodal , Cardiomiopatia de Takotsubo/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , 3-Iodobenzilguanidina , Cardiologia/normas , Doenças Cardiovasculares , Ecocardiografia , Fluordesoxiglucose F18 , Ventrículos do Coração/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Medicina Nuclear , Tomografia por Emissão de Pósitrons , Cintilografia , Compostos Radiofarmacêuticos
18.
J Nucl Cardiol ; 26(3): 909-918, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-29243072

RESUMO

OBJECTIVE: FDG PET/CT plays a significant role in the diagnosis of inflammatory heart diseases and cardiac tumors. We attempted to determine the optimal FDG uptake threshold for volume-based analyses and to evaluate the relationship between the myocardial physiological uptake volume in FDG PET and several clinical factors. METHODS: A total of 190 patients were retrospectively analyzed. The cardiac metabolic volume (CMV) was defined as a volume within the boundary determined by a threshold (SUVmean of blood pool × 1.5). RESULTS: The SUVmean of the blood pool measured in the descending aorta (DA) (r = 0.86, intraclass correlation coefficient [ICC] = 0.93, P < 0.0001) and that in the left ventricle (LV) cavity (r = 0.87, ICC = 0.90, P < 0.0001) showed high inter-operator reproducibility. However, the SUVmean in the LV cavity showed a significant correlation with the CMV (P = 0.0002, r = 0.26). The CMV in the patients who fasted < 18 hours were significantly higher (49.7  ±  73.2 vs. 18.0  ±  53.8 mL, P = 0.0013) compared to the patients with > 18-hour fasting. The multivariate analysis demonstrated that only the fasting period > 18 hours was independently associated with CMV = 0. CONCLUSION: Our findings revealed that the DA is suitable to decide the threshold for the volume-based analysis. The fasting time was significantly associated with the cardiac FDG uptake.


Assuntos
Fluordesoxiglucose F18/farmacocinética , Glucose/metabolismo , Cardiopatias/diagnóstico por imagem , Miocárdio/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos/farmacocinética , Idoso , Aorta Torácica/diagnóstico por imagem , Volume Sanguíneo , Feminino , Cardiopatias/metabolismo , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos
19.
J Nucl Cardiol ; 26(4): 1079-1089, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-29181786

RESUMO

RATIONALE: Adaptive servo-ventilation (ASV), a novel respiratory support therapy for sleep disorders, may improve cardiac function in heart failure (HF). However, the reasons that ASV improves cardiac function have not been fully studied especially in sympathetic nervous function (SNF). The purpose of the present study was to investigate the effects of ASV therapy on cardiac SNF in patients with HF. METHODS: We evaluated ASV therapeutic effects before and 6 months after ASV therapy in 9 HF patients [57.3 ± 17.3 years old, left ventricular ejection fraction (LVEF) 36.1 ± 16.7%]. We performed echocardiography, polysomnography, biomarkers, 11C-hydroxyephedrine (HED) PET as a presynaptic function marker and planar 123I-metaiodobenzylguanidine (MIBG) to evaluate washout rate. RESULTS: ASV therapy reduced apnea-hypopnea index (AHI) and improved plasma brain natriuretic peptide (BNP) concentration. In 123I-MIBG imaging, the early heart/mediastinum (H/M) ratio increased after ASV therapy (2.19 ± 0.58 to 2.40 ± 0.67; P = 0.045). Washout rate did not change (23.8 ± 7.3% to 23.8 ± 8.8%; P = 0.122). Global 11C-HED retention index (RI) improved from 0.068 ± 0.033/s to 0.075 ± 0.034/s (P = 0.029). CONCLUSIONS: ASV reduced AHI and improved BNP. ASV might initially improve presynaptic cardiac sympathetic nervous function in HF patients after 6 months of treatment.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Tomografia por Emissão de Pósitrons , Respiração Artificial , Tomografia Computadorizada de Emissão de Fóton Único , 3-Iodobenzilguanidina , Adulto , Idoso , Apneia/diagnóstico por imagem , Isótopos de Carbono , Ecocardiografia , Efedrina/análogos & derivados , Feminino , Humanos , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Peptídeo Natriurético Encefálico/sangue , Polissonografia , Sistema Nervoso Simpático/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA