Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 28(13): 19783-19796, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32672248

RESUMO

We present the results of performance studies of the upgraded optical part of the time-of-flight subdetector prototype for the AFP (ATLAS Forward Proton) detector obtained during the test campaign in a synchrotron test-beam facility with 5 GeV electrons at the DESY laboratory (Hamburg, Germany) in June 2019. The detection of the particle arrival time is based on generation of Cherenkov light in an L-shaped fused silica bar. In the previous version of the ToF, all bars were made of two pieces (radiator and light guide) glued together with a dedicated glue (Epotek 305). This solution suffers from additional radiation damage of glue. We adopted a new technique of bar production without the need of glue. The new bars have a higher optical throughput by a factor of 1.6, reduced fragility, and better geometrical precision.

2.
Opt Express ; 19(5): 4199-209, 2011 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-21369249

RESUMO

Diffuse and specular characteristics of the Tyvek 1025-BL material are reported with respect to their implementation in the Geant4 Monte Carlo simulation toolkit. This toolkit incorporates the UNIFIED model. Coefficients defined by the UNIFIED model were calculated from the bidirectional reflectance distribution function (BRDF) profiles measured with a scatterometer for several angles of incidence. Results were amended with profile measurements made by a profilometer.


Assuntos
Modelos Químicos , Polímeros/química , Linguagens de Programação , Software , Simulação por Computador , Luz , Teste de Materiais , Refratometria , Espalhamento de Radiação
3.
Opt Express ; 17(15): 12723-30, 2009 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-19654678

RESUMO

Total hip arthroplasty (THA) significantly improves the quality of life in majority of patients with severe osteoarthritis. However, long-term outcomes of THAs are compromised by aseptic loosening and periprosthetic osteolysis which needs revision surgery. Both of these are causally linked to a prosthetic wear deliberated from the prosthetic articulating surfaces. As a result, there is a need to measure the mode and magnitude of wear. The paper evaluates three optical methods proposed for construction of a device for the non-contact prosthetic wear measurement. Of them, the scanning profilometry achieved promising combination of accuracy and repeatability. Simultaneously, it is time efficient to enable the development of a sensor for wear measurement.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Imageamento Tridimensional/métodos , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Algoritmos , Análise de Fourier , Humanos , Microscopia/métodos , Modelos Teóricos , Osteólise , Desenho de Prótese , Reoperação , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA