RESUMO
We demonstrate flow-free transport of cells and particles by the use of frequency-modulated ultrasonic actuation of a microfluidic chip. Two different modulation schemes are combined: A rapid (1 kHz) linear frequency sweep around approximately 6.9 MHz is used for two-dimensional spatial stabilization of the force field over a 5 mm long inlet channel of constant cross section, and a slow (0.2-0.7 Hz) linear frequency sweep around approximately 2.6 MHz is used for flow-free ultrasonic transport and positioning of cells or particles. The method is used for controlling the motion and position of cells monitored with high-resolution optical microscopy, but can also be used more generally for improving the robustness and performance of ultrasonic manipulation micro-devices.
Assuntos
Técnicas Analíticas Microfluídicas , Ultrassom , Animais , Transporte Biológico , Linhagem Celular , Células Matadoras Naturais , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Ondas de RádioRESUMO
We demonstrate selective retention and positioning of cells or other bioparticles by ultrasonic manipulation in a microfluidic expansion chamber during microfluidic perfusion. The chamber is designed as a confocal ultrasonic resonator for maximum confinement of the ultrasonic force field at the chamber center, where the cells are trapped. We investigate the resonant modes in the expansion chamber and its connecting inlet channel by theoretical modeling and experimental verification during no-flow conditions. Furthermore, by triple-frequency ultrasonic actuation during continuous microfluidic sample feeding, a set of several manipulation functions performed in series is demonstrated: sample bypass--injection--aggregation and retention--positioning. Finally, we demonstrate transillumination microscopy imaging of ultrasonically trapped COS-7 cell aggregates.
Assuntos
Separação Celular/métodos , Sonicação/métodos , Animais , Células COS , Chlorocebus aethiops , MicroscopiaRESUMO
Ultrasonic-standing-wave (USW) technology has potential to become a standard method for gentle and contactless cell handling in microfluidic chips. We investigate the viability of adherent cells exposed to USWs by studying the proliferation rate of recultured cells following ultrasonic trapping and aggregation of low cell numbers in a microfluidic chip. The cells form 2-D aggregates inside the chip and the aggregates are held against a continuous flow of cell culture medium perpendicular to the propagation direction of the standing wave. No deviations in the doubling time from expected values (24 to 48 h) were observed for COS-7 cells held in the trap at acoustic pressure amplitudes up to 0.85 MPa and for times ranging between 30 and 75 min. Thus, the results demonstrate the potential of ultrasonic standing waves as a tool for gentle manipulation of low cell numbers in microfluidic systems.