Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Gastroenterol ; 24(1): 20, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38182996

RESUMO

BACKGROUND: To investigate the feasibility of a deformable self-assembled magnetic anastomosis ring (DSAMAR), designed and developed by us, for endoscopic gastrointestinal bypass anastomosis. METHODS: Ten experimental pigs were used as model animals. The DSAMAR comprises 10 trapezoidal magnetic units, arranged in a straight line under the constraint of a guide wire. When the desired anastomosis site is reached under the guidance of an endoscope, the catheter pushes the magnetic unit along the guide wire. The linear DSAMAR can be assembled into a circular DSAMAR. Two DSAMARs were inserted, one at the end of the duodenum and the other into the stomach successively. They attracted each other and compressed the wall of the stomach and duodenum to establish gastrointestinal bypass anastomosis. The experimental pigs were euthanized 4 weeks after the operation, and the gastrointestinal bypass anastomosis specimens were obtained. The anastomosis formation was evaluated by the naked eye and histology. RESULTS: Gastrointestinal bypass anastomosis with DSAMARs was successfully performed. The average operation time under an endoscope was 70.30 ± 19.05 min (range: 43-95 min). The DSAMARs were discharged through the anus 10-17 days after surgery. There were no complications such as gastrointestinal bleeding, perforation, anastomotic fistula, and gastrointestinal obstruction during and after the operation. Gastroscopy and gross specimen of the anastomosis showed a well-formed magnetic anastomosis. Histological observation showed good continuity of the serous membrane and the mucosa of magnetic anastomosis. CONCLUSION: The DSAMAR is a safe and feasible device for fashioning gastrointestinal bypass anastomosis in this animal model.


Assuntos
Gastroscopia , Estômago , Suínos , Animais , Anastomose Cirúrgica , Estômago/cirurgia , Duodeno , Fenômenos Magnéticos
2.
Sci Rep ; 14(1): 1865, 2024 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-38253773

RESUMO

Magnetic compression anastomosis has been reported to have remarkable clinical outcomes. Here, we tested the applicability of a Y-Z deformable magnetic ring (DMR) for non-surgical manipulation of rectal stenosis (RS) in a beagle dog model under a transanal single-access condition. RS was modeled in 8 beagle dogs using partial ligation with silk thread. Under X-ray guidance, the Y-Z DMR was positioned at the proximal and distal ends of the RS, and the magnetic ring was bent into an "O" shape, such that the two rings were magnetically attracted. Operation time, complications during or after operation, and discharge time of the magnetic rings were recorded. The anastomosis bursting pressure was measured two weeks after removing the rings, and its formation was assessed through gross and histological examination. Partial ligation with a silk thread successfully established the canine RS model. After Y-Z DMR installation, the magnetic ring was successfully reconfigured from an "S" to an "O" shape. Strong attraction existed between the rings. The operation time was 9-15 min (average: 11.75 ± 1.98 min). No rectal bleeding or perforation occurred during or after operation. The ring was naturally expelled 7-10 days after surgery. A pressure of > 300 mmHg was recorded at the point of anastomosis rupture. The rectal anastomosis appeared to have healed properly on the surface, which was confirmed histologically, signifying the success of this procedure. A Y-Z DMR facilitated the successful recanalization of transanal single-channel RS without needing surgery in an animal model.


Assuntos
Fenômenos Magnéticos , Seda , Animais , Cães , Constrição Patológica/cirurgia , Fenômenos Físicos , Anastomose Cirúrgica
3.
Sci Rep ; 14(1): 7907, 2024 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575669

RESUMO

Vesicovaginal fistula lacks a standard, established animal model, making surgical innovations for this condition challenging. Herein, we aimed to non-surgically establish vesicovaginal fistula using the magnetic compression technique, and the feasibility of this method was explored using eight female Beagle dogs as model animals. In these dogs, cylindrical daughter and parent magnets were implanted into the bladder and vagina, respectively, after anesthesia, and the positions of these magnets were adjusted under X-ray supervision to make them attract each other, thus forming the structure of daughter magnet-bladder wall-vaginal wall-parent magnet. Operation time and collateral damage were recorded. The experimental animals were euthanized 2 weeks postoperatively, and the vesicovaginal fistula gross specimens were obtained. The size of the fistula was measured. Vesicovaginal fistula was observed by naked eye and under a light microscope. Magnet placement was successful in all dogs, and remained in the established position for the reminder of the experiment. The average operation time was 14.38 min ± 1.66 min (range, 12-17 min). The dogs were generally in good condition postoperatively and were voiding normally, with no complications like bleeding and urine retention. The magnets were removed from the vagina after euthanasia. The vesicovaginal fistula was successfully established according to gross observation, and the fistula diameters were 4.50-6.24 mm. Histological observation revealed that the bladder mucosa and vaginal mucosa were in close contact on the internal surface of the fistula. Taken together, magnetic compression technique is a simple and feasible method to establish an animal model of vesicovaginal fistula using Beagle dogs. This model can help clinicians study new surgical techniques and practice innovative approaches for treating vesicovaginal fistula.


Assuntos
Fístula Vesicovaginal , Humanos , Cães , Animais , Feminino , Fístula Vesicovaginal/cirurgia , Fístula Vesicovaginal/etiologia , Bexiga Urinária/cirurgia , Vagina/cirurgia , Magnetismo , Fenômenos Magnéticos
4.
Sci Rep ; 14(1): 10602, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719935

RESUMO

Although the application of magnetic compression anastomosis is becoming increasingly widespread, the magnets used in earlier studies were mostly in the shape of a whole ring. Hence, a deformable self-assembled magnetic anastomosis ring (DSAMAR) was designed in this study for gastrointestinal anastomosis. Furthermore, its feasibility was studied using a beagle model. The designed DSAMAR comprised 10 trapezoidal magnetic units. Twelve beagles were used as animal models, and DSAMARs were inserted into the stomach and colon through the mouth and anus, respectively, via endoscopy to achieve gastrocolic magnamosis. Surgical time, number of failed deformations, survival rate of the animals, and the time of magnet discharge were documented. A month later, specimens of the anastomosis were obtained and observed with the naked eye as well as microscopically. In the gastrocolic anastomosis of the 12 beagles, the procedure took 65-120 min. Although a deformation failure occurred during the operation in one of the beagles, it was successful after repositioning. The anastomosis was formed after the magnet fell off 12-18 days after the operation. Naked eye and microscopic observations revealed that the anastomotic specimens obtained 1 month later were well-formed, smooth, and flat. DSAMAR is thus feasible for gastrointestinal anastomosis under full endoscopy via the natural orifice.


Assuntos
Anastomose Cirúrgica , Estudos de Viabilidade , Animais , Cães , Anastomose Cirúrgica/métodos , Estômago/cirurgia , Imãs , Magnetismo , Cirurgia Endoscópica por Orifício Natural/métodos , Cirurgia Endoscópica por Orifício Natural/instrumentação , Colo/cirurgia , Masculino
5.
Sci Rep ; 14(1): 12462, 2024 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-38816430

RESUMO

Various surgical methods have so far been developed for treating rectovaginal fistula (RVF), each with its own advantages and disadvantages. The lack of standardized animal models of RVF is a major reason for the failure to establish a unified and effective surgical method for the treatment of RVF. This study aimed to explore the feasibility of an RVF animal model by magnetic compression and compare it with the traditional modeling method. Thirty-two female Japanese white rabbits were randomly divided into four groups: A, B, C, and D, based on how the rectovaginal septum was treated. The operation time, intraoperative blood loss, and model success rate of each group were determined. The experimental animals were euthanized 2 weeks after the operation. Their rectovaginal septum specimens were obtained. RVF was observed by the naked eye. The fistula size was measured. Histological changes of fistula were observed by hematoxylin and eosin and Masson staining. All rabbits completed the RVF model and survived 2 weeks after the operation. Groups A and B had no bleeding, while groups C and D had < 0.5 mL of bleeding. The magnet detached in 4-6 days in group A, while it remained in place for 2 weeks after surgery in group B. Only one group D rabbit had a plastic hose for 2 weeks after surgery. The RVFs of groups A and C healed by themselves. In group B, the fistula was well formed. In group D, fistula healing was observed in three animals and the diameter of the fistulas was only 2.82-4.64 mm in the other four animals. Groups B and D had a scar on the inner surface of fistulas. Our study shows that the magnetic compression technique based on the T-shaped magnet is a highly useful method to establishing a continuous and stable RVF model in rabbits.


Assuntos
Modelos Animais de Doenças , Fístula Retovaginal , Animais , Coelhos , Feminino , Fístula Retovaginal/cirurgia , Fístula Retovaginal/patologia
6.
World J Gastroenterol ; 30(16): 2272-2280, 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38690021

RESUMO

BACKGROUND: The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula (TEF), but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control. We designed a T-shaped magnet system to overcome these problems and verified its effectiveness via animal experiments. AIM: To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs. METHODS: Twelve beagles were randomly assigned to groups in which magnets of the T-shaped scheme (study group, n = 6) or normal magnets (control group, n = 6) were implanted into the trachea and esophagus separately under gastroscopy. Operation time, operation success rate, and accidental injury were recorded. After operation, the presence and timing of cough and the time of magnet shedding were observed. Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing, and gross specimens of TEFs were obtained. Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery, and gross specimens were obtained. Fistula size was measured in all animals, and then harvested fistula specimens were examined by hematoxylin and eosin (HE) and Masson trichrome staining. RESULTS: The operation success rate was 100% for both groups. Operation time did not differ between the study group (5.25 min ± 1.29 min) and the control group (4.75 min ± 1.70 min; P = 0.331). No bleeding, perforation, or unplanned magnet attraction occurred in any animal during the operation. In the early postoperative period, all dogs ate freely and were generally in good condition. Dogs in the control group had severe cough after drinking water at 6-9 d after surgery. X-ray indicated that the magnets had entered the stomach, and gastroscopy showed TEF formation. Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm ± 1.29 mm (range, 3.52-6.56 mm). HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas. Dogs in the study group did not exhibit obvious coughing after surgery. X-ray examination 2 wk after surgery indicated fixed magnet positioning, and gastroscopy showed no change in magnet positioning. The magnets were removed using a snare under endoscopy, and TEF was observed. Gross specimens showed well-formed fistulas with a diameter of 6.11 mm ± 0.16 mm (range, 5.92-6.36 mm), which exceeded that in the control group (P < 0.001). Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining, and the structure was more regular than that in the control group. CONCLUSION: Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets. Most importantly, this model offers better controllability, which improves the flexibility of follow-up studies.


Assuntos
Modelos Animais de Doenças , Imãs , Traqueia , Fístula Traqueoesofágica , Animais , Cães , Fístula Traqueoesofágica/cirurgia , Fístula Traqueoesofágica/patologia , Fístula Traqueoesofágica/etiologia , Traqueia/cirurgia , Traqueia/patologia , Esôfago/cirurgia , Esôfago/patologia , Esôfago/diagnóstico por imagem , Gastroscopia/instrumentação , Gastroscopia/métodos , Duração da Cirurgia , Masculino , Magnetismo/instrumentação , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA