1.
Annu Rev Physiol ; 85: 1-24, 2023 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-36400128

RESUMO

The generation of an internal body model and its continuous update is essential in sensorimotor control. Although known to rely on proprioceptive sensory feedback, the underlying mechanism that transforms this sensory feedback into a dynamic body percept remains poorly understood. However, advances in the development of genetic tools for proprioceptive circuit elements, including the sensory receptors, are beginning to offer new and unprecedented leverage to dissect the central pathways responsible for proprioceptive encoding. Simultaneously, new data derived through emerging bionic neural machine-interface technologies reveal clues regarding the relative importance of kinesthetic sensory feedback and insights into the functional proprioceptive substrates that underlie natural motor behaviors.


Assuntos
Biônica , Propriocepção , Humanos , Propriocepção/fisiologia , Retroalimentação Sensorial/fisiologia , Células Receptoras Sensoriais/fisiologia
2.
Sensors (Basel) ; 21(5)2021 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-33800790

RESUMO

Advances in lower-limb prosthetic technologies have facilitated the restoration of ambulation; however, users of such technologies still experience reduced balance control, also due to the absence of proprioceptive feedback. Recent efforts have demonstrated the ability to restore kinesthetic feedback in upper-limb prosthesis applications; however, technical solutions to trigger the required muscle vibration and provide automated feedback have not been explored for lower-limb prostheses. The study's first objective was therefore to develop a feedback system capable of tracking lower-limb movement and automatically triggering a muscle vibrator to induce the kinesthetic illusion. The second objective was to investigate the developed system's ability to provide kinesthetic feedback in a case participant. A low-cost, wireless feedback system, incorporating two inertial measurement units to trigger a muscle vibrator, was developed and tested in an individual with limb loss above the knee. Our system had a maximum communication delay of 50 ms and showed good tracking of Gaussian and sinusoidal movement profiles for velocities below 180 degrees per second (error < 8 degrees), mimicking stepping and walking, respectively. We demonstrated in the case participant that the developed feedback system can successfully elicit the kinesthetic illusion. Our work contributes to the integration of sensory feedback in lower-limb prostheses, to increase their use and functionality.


Assuntos
Membros Artificiais , Análise Custo-Benefício , Retroalimentação , Humanos , Cinestesia , Movimento
3.
BMC Med Res Methodol ; 18(1): 141, 2018 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-30453897

RESUMO

BACKGROUND: Indices of inter-evaluator reliability are used in many fields such as computational linguistics, psychology, and medical science; however, the interpretation of resulting values and determination of appropriate thresholds lack context and are often guided only by arbitrary "rules of thumb" or simply not addressed at all. Our goal for this work was to develop a method for determining the relationship between inter-evaluator agreement and error to facilitate meaningful interpretation of values, thresholds, and reliability. METHODS: Three expert human evaluators completed a video analysis task, and averaged their results together to create a reference dataset of 300 time measurements. We simulated unique combinations of systematic error and random error onto the reference dataset to generate 4900 new hypothetical evaluators (each with 300 time measurements). The systematic errors and random errors made by the hypothetical evaluator population were approximated as the mean and variance of a normally-distributed error signal. Calculating the error (using percent error) and inter-evaluator agreement (using Krippendorff's alpha) between each hypothetical evaluator and the reference dataset allowed us to establish a mathematical model and value envelope of the worst possible percent error for any given amount of agreement. RESULTS: We used the relationship between inter-evaluator agreement and error to make an informed judgment of an acceptable threshold for Krippendorff's alpha within the context of our specific test. To demonstrate the utility of our modeling approach, we calculated the percent error and Krippendorff's alpha between the reference dataset and a new cohort of trained human evaluators and used our contextually-derived Krippendorff's alpha threshold as a gauge of evaluator quality. Although all evaluators had relatively high agreement (> 0.9) compared to the rule of thumb (0.8), our agreement threshold permitted evaluators with low error, while rejecting one evaluator with relatively high error. CONCLUSIONS: We found that our approach established threshold values of reliability, within the context of our evaluation criteria, that were far less permissive than the typically accepted "rule of thumb" cutoff for Krippendorff's alpha. This procedure provides a less arbitrary method for determining a reliability threshold and can be tailored to work within the context of any reliability index.


Assuntos
Algoritmos , Simulação por Computador , Modelos Teóricos , Variações Dependentes do Observador , Humanos , Reconhecimento Automatizado de Padrão/métodos , Reprodutibilidade dos Testes
4.
J Neuroeng Rehabil ; 14(1): 118, 2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29149885

RESUMO

The reduction in physical activity following a spinal cord injury often leads to a decline in mental and physical health. Developing an exercise program that is effective and enjoyable is paramount for this population. Although functional electrical stimulation (FES) stationary cycling has been utilized in rehabilitation settings, implementing an overground cycling program for those with spinal cord injuries has greater technical challenges. Recently our laboratory team focused on training five individuals with compete spinal cord injuries utilizing an implanted pulse generator for an overground FES bike race in CYBATHLON 2016 held in Zurich, Switzerland. The advancements in muscle strength and endurance and ultimately cycling power our pilots made during this training period not only helped propel our competing pilot to win gold at the CYBATHLON 2016, but allowed our pilots to ride their bikes outside within their communities. Such a positive outcome has encouraged us to put effort into developing more widespread use of FES overground cycling as a rehabilitative tool for those with spinal cord injuries. This commentary will describe our approach to the CYBATHLON 2016 including technological advancements, bike design and the training program.


Assuntos
Ciclismo , Terapia por Estimulação Elétrica/métodos , Terapia por Exercício/métodos , Traumatismos da Medula Espinal/reabilitação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
5.
J Physiol ; 596(2): 133-134, 2018 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-29194626
6.
J Am Chem Soc ; 135(13): 5167-74, 2013 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-23530595

RESUMO

Inspired by the water-enhanced mechanical gradient character of the squid beak, we herein report a nanocomposite that mimics both the architecture and properties of this interesting natural material. Similar to the squid beak, we have developed nanocomposites where the degree of cross-linking is controlled along the length of the film. In this study, we utilized tunicate cellulose nanocrystals as the nanofiller that are functionalized with allyl moieties. Using photoinduced thiol-ene chemistry, we have been able to cross-link the CNC nanofiller. In the dry state where strong CNC interactions can occur, only a small mechanical contrast is observed between the cross-linked and uncross-linked samples. However, when the films are exposed to water, which "switches off" the noncovalent CNC interactions, a significant mechanical contrast is observed between the same films. For example, at 20 wt % CNC (in the dry film), an increase in wet modulus from 60 to 300 MPa (∼500% increase) is observed after photoirradiation. Furthermore, we show that the wet modulus can be controlled by altering the UV exposure time which allows access to mechanical gradient films.


Assuntos
Biomimética , Decapodiformes/química , Nanocompostos/química , Estresse Mecânico , Água/química , Animais , Bico/química , Reagentes de Ligações Cruzadas/química , Microscopia Eletrônica de Varredura , Estrutura Molecular , Propriedades de Superfície
7.
Expert Rev Med Devices ; 20(9): 729-739, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37537898

RESUMO

INTRODUCTION: A key determinant of prosthesis use is the quality of fit of the prosthetic socket. The socket surrounds the residual limb and applies the appropriate force distribution to the soft tissues to maintain suspension, support, and stabilization as well as translate limb movement to prosthesis movement. The challenge in socket fabrication lays in achieving geometry that provides the appropriate force distribution at physiologically appropriate locations; a task dependent on the understanding of interface tissue-mechanics. AREAS COVERED: In the last 20 years substantial advancements in sensor innovation and computational power have allowed researchers to quantify the socket-residual limb interface; this paper reviews prominent measurement and sensing techniques described in literature over this time frame. Advantages and short comings of each technique are discussed with a focus on translation to clinical environments. EXPERT OPINION: Prosthetic sockets directly influence comfort, device use, user satisfaction, and tissue health. Advancements in instrumentation technology have unlocked the possibility of sophisticated measurement systems providing quantitative data that may work in tandem with a clinician's heuristic expertise during socket fabrication. If validated, many of the emerging sensing technologies could be implemented into a clinical setting to better characterize how patients interact with their device and help inform prosthesis fabrication and assessment techniques.


Assuntos
Membros Artificiais , Implantação de Prótese , Humanos , Desenho de Prótese , Fenômenos Mecânicos , Extremidades , Cotos de Amputação
8.
Brain ; 134(Pt 3): 747-58, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21252109

RESUMO

Existing prosthetic limbs do not provide amputees with cutaneous feedback. Tactile feedback is essential to intuitive control of a prosthetic limb and it is now clear that the sense of body self-identification is also linked to cutaneous touch. Here we have created an artificial sense of touch for a prosthetic limb by coupling a pressure sensor on the hand through a robotic stimulator to surgically redirected cutaneous sensory nerves (targeted reinnervation) that once served the lost limb. We hypothesize that providing physiologically relevant cutaneous touch feedback may help an amputee incorporate an artificial limb into his or her self image. To investigate this we used a robotic touch interface coupled with a prosthetic limb and tested it with two targeted reinnervation amputees in a series of experiments fashioned after the Rubber Hand Illusion. Results from both subjective (self-reported) and objective (physiological) measures of embodiment (questionnaires, psychophysical temporal order judgements and residual limb temperature measurements) indicate that returning physiologically appropriate cutaneous feedback from a prosthetic limb drives a perceptual shift towards embodiment of the device for these amputees. Measurements provide evidence that the illusion created is vivid. We suggest that this may help amputees to more effectively incorporate an artificial limb into their self image, providing the possibility that a prosthesis becomes not only a tool, but also an integrated body part.


Assuntos
Cotos de Amputação/inervação , Percepção/fisiologia , Membro Fantasma/psicologia , Implantação de Prótese/psicologia , Robótica/métodos , Tato/fisiologia , Cotos de Amputação/fisiopatologia , Biorretroalimentação Psicológica , Mãos/inervação , Mãos/fisiopatologia , Humanos , Ilusões/psicologia , Julgamento , Masculino , Limiar Sensorial/fisiologia , Inquéritos e Questionários , Temperatura , Adulto Jovem
9.
J Neurosci ; 30(47): 16008-14, 2010 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-21106839

RESUMO

Prosthetic limbs are difficult to control and do not provide sensory feedback. Targeted reinnervation was developed as a neural-machine interface for amputees to address these issues. In targeted reinnervation, amputated nerves are redirected to proximal muscles and skin, creating nerve interfaces for prosthesis control and sensory feedback. Touching the reinnervated skin causes sensation to be projected to the missing limb. Here we use electrophysiological brain recording in the Sprague Dawley rat to investigate the changes to somatosensory cortex (S1) following amputation and nerve redirection with the intent to provide insight into the sensory phenomena observed in human targeted reinnervation amputees. Recordings revealed that redirected nerves established an expanded representation in S1, which may help to explain the projected sensations that encompass large areas of the hand in targeted reinnervation amputees. These results also provide evidence that the reinnervated target skin could serve as a line of communication from a prosthesis to cortical hand processing regions. S1 border regions were simultaneously responsive to reinnervated input and also vibrissae, lower lip, and hindfoot, suggesting competition for deactivated cortical territory. Electrically evoked potential latencies from reinnervated skin to cortex suggest direct connection of the redirected afferents to the forepaw processing region of S1. Latencies also provide evidence that the widespread reactivation of S1 cortex may arise from central anatomical interconnectivity. Targeted reinnervation offers the opportunity to examine the cortical plasticity effects when behaviorally important sensory afferents are redirected from their original location to a new skin surface on a different part of the body.


Assuntos
Amputação Cirúrgica , Membro Anterior/inervação , Membro Anterior/fisiologia , Nervo Mediano/fisiologia , Plasticidade Neuronal/fisiologia , Córtex Somatossensorial/fisiologia , Amputação Cirúrgica/métodos , Animais , Mapeamento Encefálico/métodos , Masculino , Ratos , Ratos Sprague-Dawley
10.
Front Neurosci ; 15: 611926, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33679300

RESUMO

Interfering with or temporarily eliminating foot-sole tactile sensations causes postural adjustments. Furthermore, individuals with impaired or missing foot-sole sensation, such as lower-limb amputees, exhibit greater postural instability than those with intact sensation. Our group has developed a method of providing tactile feedback sensations projected to the missing foot of lower-limb amputees via electrical peripheral nerve stimulation (PNS) using implanted nerve cuff electrodes. As a step toward effective implementation of the system in rehabilitation and everyday use, we compared postural adjustments made in response to tactile sensations on the missing foot elicited by our system, vibration on the intact foot-sole, and a control condition in which no additional sensory input was applied. Three transtibial amputees with at least a year of experience with tactile sensations provided by our PNS system participated in the study. Participants stood quietly with their eyes closed on their everyday prosthesis while electrically elicited, vibratory, or no additional sensory input was administered for 20 s. Early and steady-state postural adjustments were quantified by center of pressure location, path length, and average angle over the course of each trial. Electrically elicited tactile sensations and vibration both caused shifts in center of pressure location compared to the control condition. Initial (first 3 s) shifts in center of pressure location with electrically elicited or vibratory sensory inputs often differed from shifts measured over the full 20 s trial. Over the full trial, participants generally shifted toward the foot receiving additional sensory input, regardless of stimulation type. Similarities between responses to electrically elicited tactile sensations projected to the missing foot and responses to vibration in analogous regions on the intact foot suggest that the motor control system treats electrically elicited tactile inputs similarly to native tactile inputs. The ability of electrically elicited tactile inputs to cause postural adjustments suggests that these inputs are incorporated into sensorimotor control, despite arising from artificial nerve stimulation. These results are encouraging for application of neural stimulation in restoring missing sensory feedback after limb loss and suggest PNS could provide an alternate method to perturb foot-sole tactile information for investigating integration of tactile feedback with other sensory modalities.

11.
Front Neurorobot ; 15: 661603, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33897401

RESUMO

During every waking moment, we must engage with our environments, the people around us, the tools we use, and even our own bodies to perform actions and achieve our intentions. There is a spectrum of control that we have over our surroundings that spans the extremes from full to negligible. When the outcomes of our actions do not align with our goals, we have a tremendous capacity to displace blame and frustration on external factors while forgiving ourselves. This is especially true when we cooperate with machines; they are rarely afforded the level of forgiveness we provide our bodies and often bear much of our blame. Yet, our brain readily engages with autonomous processes in controlling our bodies to coordinate complex patterns of muscle contractions, make postural adjustments, adapt to external perturbations, among many others. This acceptance of biological autonomy may provide avenues to promote more forgiving human-machine partnerships. In this perspectives paper, we argue that striving for machine embodiment is a pathway to achieving effective and forgiving human-machine relationships. We discuss the mechanisms that help us identify ourselves and our bodies as separate from our environments and we describe their roles in achieving embodied cooperation. Using a representative selection of examples in neurally interfaced prosthetic limbs and intelligent mechatronics, we describe techniques to engage these same mechanisms when designing autonomous systems and their potential bidirectional interfaces.

12.
Front Neurorobot ; 15: 610673, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33732129

RESUMO

Stroke patients often have difficulty completing motor tasks even after substantive rehabilitation. Poor recovery of motor function can often be linked to stroke-induced damage to motor pathways. However, stroke damage in pathways that impact effective integration of sensory feedback with motor control may represent an unappreciated obstacle to smooth motor coordination. In this study we investigated the effects of augmenting movement proprioception during a reaching task in six stroke patients as a proof of concept. We used a wearable neurorobotic proprioceptive feedback system to induce illusory kinaesthetic sensation by vibrating participants' upper arm muscles over active limb movements. Participants were instructed to extend their elbow to reach-and-point to targets of differing sizes at various distances, while illusion-inducing vibration (90 Hz), sham vibration (25 Hz), or no vibration was applied to the distal tendons of either their biceps brachii or their triceps brachii. To assess the impact of augmented kinaesthetic feedback on motor function we compared the results of vibrating the biceps or triceps during arm extension in the affected arm of stroke patients and able-bodied participants. We quantified performance across conditions and participants by tracking limb/hand kinematics with motion capture, and through Fitts' law analysis of reaching target acquisition. Kinematic analyses revealed that injecting 90 Hz illusory kinaesthetic sensation into the actively contracting (agonist) triceps muscle during reaching increased movement smoothness, movement directness, and elbow extension. Conversely, injecting 90 Hz illusory kinaesthetic sensation into the antagonistic biceps during reaching negatively impacted those same parameters. The Fitts' law analyses reflected similar effects with a trend toward increased throughput with triceps vibration during reaching. Across all analyses, able-bodied participants were largely unresponsive to illusory vibrational augmentation. These findings provide evidence that vibration-induced movement illusions delivered to the primary agonist muscle involved in active movement may be integrated into rehabilitative approaches to help promote functional motor recovery in stroke patients.

13.
Sci Robot ; 6(58): eabf3368, 2021 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-34516746

RESUMO

Bionic prostheses have restorative potential. However, the complex interplay between intuitive motor control, proprioception, and touch that represents the hallmark of human upper limb function has not been revealed. Here, we show that the neurorobotic fusion of touch, grip kinesthesia, and intuitive motor control promotes levels of behavioral performance that are stratified toward able-bodied function and away from standard-of-care prosthetic users. This was achieved through targeted motor and sensory reinnervation, a closed-loop neural-machine interface, coupled to a noninvasive robotic architecture. Adding touch to motor control improves the ability to reach intended target grasp forces, find target durometers among distractors, and promote prosthetic ownership. Touch, kinesthesia, and motor control restore balanced decision strategies when identifying target durometers and intrinsic visuomotor behaviors that reduce the need to watch the prosthetic hand during object interactions, which frees the eyes to look ahead to the next planned action. The combination of these three modalities also enhances error correction performance. We applied our unified theoretical, functional, and clinical analyses, enabling us to define the relative contributions of the sensory and motor modalities operating simultaneously in this neural-machine interface. This multiperspective framework provides the necessary evidence to show that bionic prostheses attain more human-like function with effective sensory-motor restoration.


Assuntos
Braço/fisiologia , Biônica , Encéfalo/fisiologia , Força da Mão , Mãos/fisiologia , Tato , Extremidade Superior/fisiologia , Adulto , Membros Artificiais , Simulação por Computador , Feminino , Humanos , Cinestesia , Masculino , Destreza Motora , Movimento , Músculo Esquelético/inervação , Redes Neurais de Computação , Desenho de Prótese , Robótica , Ombro/fisiologia , Percepção do Tato
14.
Brain ; 132(Pt 6): 1441-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19369486

RESUMO

Targeted reinnervation is a new neural-machine interface that has been developed to help improve the function of new-generation prosthetic limbs. Targeted reinnervation is a surgical procedure that takes the nerves that once innervated a severed limb and redirects them to proximal muscle and skin sites. The sensory afferents of the redirected nerves reinnervate the skin overlying the transfer site. This creates a sensory expression of the missing limb in the amputee's reinnervated skin. When these individuals are touched on this reinnervated skin they feel as though they are being touched on their missing limb. Targeted reinnervation takes nerves that once served the hand, a skin region of high functional importance, and redirects them to less functionally relevant skin areas adjacent to the amputation site. In an effort to better understand the sensory capacity of the reinnervated target skin following this procedure, we examined grating orientation thresholds and point localization thresholds on two amputees who had undergone the targeted reinnervation surgery. Grating orientation thresholds and point localization thresholds were also measured on the contralateral normal skin of the targeted reinnervation amputees and on analogous sites in able-bodied controls. Grating orientation thresholds for the reinnervated skin of the targeted reinnervation amputees were found to be similar to normal ranges for both the amputees' contralateral skin and also for the control population. Point localization thresholds for these amputees were found to be lower for their reinnervated skin than for their contralateral skin. Reinnervated point localization thresholds values were also lower in comparison to homologous chest sites on the control population. Mechanisms appear to be in place to maximize re-established touch input in targeted reinnervation amputees. It seems that sound sensory function is provided to the denervated skin of the residual limb when connected to afferent pathways once serving highly functionally relevant regions of the brain. This suggests that tactile interface devices could be used to give a physiologically appropriate sense of touch to a prosthetic limb, which would likely help with better functional utilization of the prosthetic device and possibly help to more effectively integrate the device with the user's self-image.


Assuntos
Amputação Cirúrgica/reabilitação , Pele/inervação , Tórax/inervação , Tato/fisiologia , Extremidade Superior/cirurgia , Adulto , Amputados/reabilitação , Membros Artificiais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desempenho Psicomotor/fisiologia , Limiar Sensorial/fisiologia , Extremidade Superior/lesões , Adulto Jovem
15.
Proc Natl Acad Sci U S A ; 104(50): 20061-6, 2007 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-18048339

RESUMO

Amputees cannot feel what they touch with their artificial hands, which severely limits usefulness of those hands. We have developed a technique that transfers remaining arm nerves to residual chest muscles after an amputation. This technique allows some sensory nerves from the amputated limb to reinnervate overlying chest skin. When this reinnervated skin is touched, the amputees perceive that they are being touched on their missing limb. We found that touch thresholds of the reinnervated chest skin fall within near-normal ranges, indicating the regeneration of large-fiber afferents. The perceptual identity of the limb and chest was maintained separately even though they shared a common skin surface. A cutaneous expression of proprioception also occurred in one reinnervated individual. Experiments with peltier temperature probes and surface electrical stimulation of the reinnervated skin indicate the regeneration of small diameter temperature and pain afferents. The perception of an amputated limb arising from stimulation of reinnervated chest skin may allow useful sensory feedback from prosthetic devices and provides insight into the mechanisms of neural plasticity and peripheral regeneration in humans.


Assuntos
Amputados , Mãos/inervação , Mãos/cirurgia , Dor , Pele/inervação , Tórax/inervação , Tato/fisiologia , Procedimentos Cirúrgicos Dermatológicos , Estimulação Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Temperatura
16.
Front Neurosci ; 14: 120, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32140096

RESUMO

Cutaneous sensation is vital to controlling our hands and upper limbs. It helps close the motor control loop by informing adjustments of grasping forces during object manipulations and provides much of the information the brain requires to perceive our limbs as a part of our bodies. This sensory information is absent to upper-limb prosthesis users. Although robotic prostheses are becoming increasingly sophisticated, the absence of feedback imposes a reliance on open-loop control and limits the functional potential as an integrated part of the body. Experimental systems to restore physiologically relevant sensory information to prosthesis users are beginning to emerge. However, the impact of their long-term use on functional abilities, body image, and neural adaptation processes remains unclear. Understanding these effects is essential to transition sensate prostheses from sophisticated assistive tools to integrated replacement limbs. We recruited three participants with high-level upper-limb amputation who previously received targeted reinnervation surgery. Each participant was fit with a neural-machine-interface prosthesis that allowed participants to operate their device by thinking about moving their missing limb. Additionally, we fit a sensory feedback system that allowed participants to experience touch to the prosthesis as touch on their missing limb. All three participants performed a long-term take-home trial. Two participants used their neural-machine-interface systems with touch feedback and one control participant used his prescribed, insensate prosthesis. A series of functional outcome metrics and psychophysical evaluations were performed using sensate neural-machine-interface prostheses before and after the take-home period to capture changes in functional abilities, limb embodiment, and neural adaptation. Our results demonstrated that the relationship between users and sensate neural-machine-interface prostheses is dynamic and changes with long-term use. The presence of touch sensation had a near-immediate impact on how the users operated their prostheses. In the multiple independent measures of users' functional abilities employed, we observed a spectrum of performance changes following long-term use. Furthermore, after the take-home period, participants more appropriately integrated their prostheses into their body images and psychophysical tests provided strong evidence that neural and cortical adaptation occurred.

17.
Prosthet Orthot Int ; 43(5): 564-567, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30922181

RESUMO

BACKGROUND AND AIM: Although upper limb myoelectric prostheses can offer improved functionality and dexterity over body-powered systems, abandonment rates remain high. User dissatisfaction in comfort and control are among the top contributors. The design of the prosthetic socket must be comfortable, while maintaining contact of control electrodes with the residual limb throughout the day. We present a myoelectric socket design that provides user-adjustable compression over electrode control sites to promote consistent control, while maintaining comfort and fit. TECHNIQUE: A cable tensioning system was threaded through a series of paneled windows in the socket wall over electrode sites. Adjusting tension provided tuning of electrode contact. DISCUSSION: A case study of a single transhumeral prosthetic user with a follow-up interview 11 months post delivery suggests that our adjustable design has the potential to address control and comfort challenges, critical factors in myoelectric prosthetic use, and abandonment. CLINICAL RELEVANCE: Achieving consistent electrode contact with muscle control sites in traditional rigid sockets is a critical challenge for myoelectric prostheses. We present a unique solution via user-adjustable electrode contacts built into the socket.


Assuntos
Amputados/reabilitação , Membros Artificiais , Úmero/cirurgia , Desenho de Prótese , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Masculino , Satisfação do Paciente , Inquéritos e Questionários
18.
Sci Rep ; 9(1): 5806, 2019 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-30967581

RESUMO

Object stiffness discrimination is fundamental to shaping the way we interact with our environment. Investigating the sensorimotor mechanisms underpinning stiffness discrimination may help further our understanding of healthy and sensory-impaired upper limb function. We developed a metric that leverages sensory discrimination techniques and a foraging-based analysis to characterize participant accuracy and discrimination processes of sensorimotor control. Our metric required searching and discriminating two variants of test-object: rubber blocks and spring cells, which emphasized cutaneous-force and proprioceptive feedback, respectively. We measured the number of test-objects handled, selection accuracy, and foraging duration. These values were used to derive six indicators of performance. We observed higher discrimination accuracies, with quicker search and handling durations, for blocks compared to spring cells. Correlative analyses of accuracy, error rates, and foraging times suggested that the block and spring variants were, in fact, unique sensory tasks. These results provide evidence that our metric is sensitive to the contributions of sensory feedback, motor control, and task performance strategy, and will likely be effective in further characterizing the impact of sensory feedback on motor control in healthy and sensory-impaired populations.


Assuntos
Retroalimentação Sensorial/fisiologia , Mãos/fisiologia , Propriocepção/fisiologia , Tato/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desempenho Psicomotor/fisiologia , Análise e Desempenho de Tarefas , Adulto Jovem
19.
Sci Rep ; 9(1): 11699, 2019 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-31406122

RESUMO

The perception of somatosensation requires the integration of multimodal information, yet the effects of vision and posture on somatosensory percepts elicited by neural stimulation are not well established. In this study, we applied electrical stimulation directly to the residual nerves of trans-tibial amputees to elicit sensations referred to their missing feet. We evaluated the influence of congruent and incongruent visual inputs and postural manipulations on the perceived size and location of stimulation-evoked somatosensory percepts. We found that although standing upright may cause percept size to change, congruent visual inputs and/or body posture resulted in better localization. We also observed visual capture: the location of a somatosensory percept shifted toward a visual input when vision was incongruent with stimulation-induced sensation. Visual capture did not occur when an adopted posture was incongruent with somatosensation. Our results suggest that internal model predictions based on postural manipulations reinforce perceived sensations, but do not alter them. These characterizations of multisensory integration are important for the development of somatosensory-enabled prostheses because current neural stimulation paradigms cannot replicate the afferent signals of natural tactile stimuli. Nevertheless, multisensory inputs can improve perceptual precision and highlight regions of the foot important for balance and locomotion.


Assuntos
Amputados/reabilitação , Equilíbrio Postural/fisiologia , Postura/fisiologia , Córtex Somatossensorial/fisiologia , Percepção do Tato/fisiologia , Percepção Visual/fisiologia , Idoso , Membros Artificiais , Estimulação Elétrica , Humanos , Perna (Membro)/inervação , Perna (Membro)/cirurgia , Masculino , Pessoa de Meia-Idade , Tíbia/inervação , Tíbia/cirurgia , Tato/fisiologia , Visão Ocular/fisiologia
20.
IEEE Int Conf Rehabil Robot ; 2019: 1233-1238, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31374798

RESUMO

Performance of lower limb prostheses is related not only to the mechanical design and the control scheme, but also to the feedback provided to the user. Proprioceptive feedback, which is the sense of position and movement of one's body parts, can improve the utility as well as facilitate the embodiment of the prosthetic device. Recent studies have shown that proprioceptive kinesthetic (movement) sense can be elicited when non-invasively vibrating a muscle tendon proximal to the targeted joint. However, consistency and quality of the elicited sensation depend on several parameters and muscle tendons after lower limb amputation may not always be accessible. In this study, we developed an experimental protocol to quantitatively and qualitatively assess the elicited proprioceptive kinesthetic illusion when non-invasively vibrating a muscle belly. Furthermore, we explored ways to improve consistency and strength of the illusion by integrating another non-invasive feedback method, namely cutaneous information manipulation via skin stretch. Our preliminary results from tests conducted with a person with transtibial (below knee) amputation show that stretching skin while vibrating a muscle belly on the residual limb provided a stronger and more consistent kinesthetic illusion (90%) than only vibrating the muscle (50%). In addition, we found that stretching skin enhances the range (1.5 times) and speed (3.5 times) of the illusory movement triggered by muscle vibration. These findings may enable the development of mechanisms for controlling feedback parameters in closing the control loop for various walking routines, which may improve performance of lower limb prostheses.


Assuntos
Amputação Cirúrgica , Ilusões/fisiologia , Extremidade Inferior/cirurgia , Pele , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Músculo Esquelético/fisiologia , Tendões/fisiologia
SELEÇÃO DE REFERÊNCIAS