Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Arch Cardiovasc Dis ; 115(10): 505-513, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36123284

RESUMO

BACKGROUND: Randomized trials comparing the first-generation absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA, USA) with a drug-eluting stent showed a moderate but significant increase in the rate of 3-year major adverse cardiac events and scaffold thrombosis, followed by a decrease in adverse events after 3 years. AIM: The objective of this study was to assess the 5-year outcomes of patients treated with at least one absorb BVS and included in the FRANCE ABSORB registry. METHODS: All patients treated in France with an absorb BVS were prospectively included in a large nationwide multicentre registry. The primary efficacy outcome was the occurrence of 5-year major adverse cardiac events. Secondary efficacy outcomes were the rates of 5-year target vessel revascularization and definite/probable scaffold thrombosis. RESULTS: Between September 2014 and April 2016, 2,070 patients were included in 86 centres (mean age 55±11 years; 80% men; 49% with acute coronary syndrome). The rates of 1-, 3- and 5-year major adverse cardiac events were 3.9%, 9.4% and 12.1%, respectively (including cardiac death in 2.5% and target vessel revascularization in 10.4%). By multivariable analysis, diabetes, oral anticoagulation, the use of multiple Absorb BVSs and the use of a 2.5mm diameter absorb BVS were associated with 5-year major adverse cardiac events. The rates of 1-, 3- and 5-year definite/probable scaffold thrombosis were 1.5%, 3.1% and 3.6%, respectively. By multivariable analysis, older age, diabetes, anticoagulation at discharge and the use of a 2.5mm diameter absorb BVS were associated with 5-year scaffold thrombosis. CONCLUSIONS: Absorb BVS implantation was associated with low rates of 1-year major adverse cardiac events, which increased significantly at 3-year follow-up. There was a clear decrease in the rates of scaffold thrombosis and major adverse cardiac events after 3 years.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Implantes Absorvíveis , Everolimo , Resultado do Tratamento , Desenho de Prótese , Fatores de Tempo , Sistema de Registros , Anticoagulantes , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia
2.
Arch Cardiovasc Dis ; 112(2): 113-123, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30630761

RESUMO

BACKGROUND: Several randomized studies have shown that bioresorbable vascular scaffold (BVS) technology is associated with an increased risk of stent thrombosis. AIM: This study aimed to assess the rates of adverse outcomes at 1 year in patients treated with the Absorb BVS (Abbott Vascular, Santa Clara, CA, USA), using data from a large nationwide prospective multicentre registry (FRANCE ABSORB). METHODS: All patients receiving the Absorb BVS in France were included prospectively in the study. Predilatation, optimal sizing and postdilatation were recommended systematically. The primary endpoint was a composite of cardiovascular death, myocardial infarction and target lesion revascularization at 1 year. Secondary endpoints were scaffold thrombosis and target vessel revascularization at 1 year. RESULTS: A total of 2072 patients at 86 centres were included: mean age 55±11 years; 80% men. The indication was acute coronary syndrome (ACS) in 49% of cases. Predilatation and postdilatation were done in 93% and 83% of lesions, respectively. At 1 year, the primary endpoint occurred in 3.9% of patients, the rate of scaffold thrombosis was 1.5% and the rate of target vessel revascularization was 3.3%. In a multivariable analysis, diabetes and total Absorb BVS length>30mm were independently associated with the occurrence of the primary endpoint, whereas oral anticoagulation and total Absorb BVS length>30mm were independently associated with occurrence of scaffold thrombosis. CONCLUSIONS: The Absorb BVS was implanted in a relatively young population, half of whom had ACS. Predilatation and postdilatation rates were high, and 1-year outcomes were acceptable.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/cirurgia , Angina Instável/cirurgia , Angioplastia Coronária com Balão/instrumentação , Infarto do Miocárdio/cirurgia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Adulto , Idoso , Angina Instável/diagnóstico por imagem , Angina Instável/mortalidade , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Trombose Coronária/etiologia , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Estudos Prospectivos , Desenho de Prótese , Recidiva , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA