Artif Intell Med ; 84: 159-170, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29310966

RESUMO

OBJECTIVE: The main objective of this research is the design and implementation of a new fuzzy logic tool for automatic drug delivery in patients undergoing general anesthesia. The aim is to adjust the drug dose to the real patient needs using heuristic knowledge provided by clinicians. A two-level computer decision system is proposed. The idea is to release the clinician from routine tasks so that he can focus on other variables of the patient. METHODS: The controller uses the Bispectral Index (BIS) to assess the hypnotic state of the patient. Fuzzy controller was included in a closed-loop system to reach the BIS target and reject disturbances. BIS was measured using a BIS VISTA monitor, a device capable of calculating the hypnosis level of the patient through EEG information. An infusion pump with propofol 1% is used to supply the drug to the patient. The inputs to the fuzzy inference system are BIS error and BIS rate. The output is infusion rate increment. The mapping of the input information and the appropriate output is given by a rule-base based on knowledge of clinicians. RESULTS: To evaluate the performance of the fuzzy closed-loop system proposed, an observational study was carried out. Eighty one patients scheduled for ambulatory surgery were randomly distributed in 2 groups: one group using a fuzzy logic based closed-loop system (FCL) to automate the administration of propofol (42 cases); the second group using manual delivering of the drug (39 cases). In both groups, the BIS target was 50. CONCLUSIONS: The FCL, designed with intuitive logic rules based on the clinician experience, performed satisfactorily and outperformed the manual administration in patients in terms of accuracy through the maintenance stage.


Assuntos
Anestesia Intravenosa/instrumentação , Anestésicos Intravenosos/administração & dosagem , Ondas Encefálicas/efeitos dos fármacos , Monitores de Consciência , Sistemas de Apoio a Decisões Clínicas , Técnicas de Apoio para a Decisão , Eletroencefalografia/instrumentação , Lógica Fuzzy , Monitorização Neurofisiológica Intraoperatória/instrumentação , Propofol/administração & dosagem , Processamento de Sinais Assistido por Computador , Adulto , Tomada de Decisão Clínica , Feminino , Humanos , Bombas de Infusão , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA