Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 150
Filtrar
1.
Catheter Cardiovasc Interv ; 91(6): E49-E55, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28980387

RESUMO

OBJECTIVES: To define the incidence of vascular complications (VC) after balloon aortic valvuloplasty (BAV) in recent years, and to compare the performance of two vascular closure devices (VCD). BACKGROUND: VC remain the most frequent drawback of BAV and are associated with adverse clinical outcomes. METHODS: All BAV procedures performed at 2 high-volume centers over a 6-year period (n = 930) were collected in prospective registries and investigated to assess the incidence of Valve Academic Research Consortium-2 (VARC-2) defined VC. Incidence of life-threatening, major and minor bleeding was also assessed. In-hospital major adverse cardiac and cerebrovascular events (MACCE) rate (composite of in-hospital death, myocardial infarction, TIA/stroke, and life-threatening bleeding) as well as 30-day survival was compared between a suture-mediated closure system and a collagen plug hemostatic device. RESULTS: A 9 Fr arterial sheath was used in most of the patients (84.1%). Vascular closure was obtained with the Angio-Seal in 643 patients (69.1%) and the ProGlide in 287 (30.9%). The overall incidence of major VC was 2.7%, and minor VC 6.6%, without significant differences between groups. The Angio-Seal group was associated with a higher rate of small hematomas (6.9% vs. 3.5%, P = 0.042), whilst blood transfusions were more frequent in the ProGlide group (6.6% vs. 3.5%, P = 0.034). Rates of in-hospital MACCE and 30-day survival were similar. Use of either VCD was not independently associated with major VC. CONCLUSIONS: VC rate after BAV is fairly low in experienced centers without major differences between the 2 most used VCD.


Assuntos
Estenose da Valva Aórtica/terapia , Valvuloplastia com Balão/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Hemorragia/prevenção & controle , Técnicas Hemostáticas/efeitos adversos , Técnicas Hemostáticas/instrumentação , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/instrumentação , Suturas , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Valvuloplastia com Balão/mortalidade , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/mortalidade , Desenho de Equipamento , Feminino , Hemorragia/diagnóstico , Hemorragia/mortalidade , Técnicas Hemostáticas/mortalidade , Hospitais com Alto Volume de Atendimentos , Humanos , Incidência , Itália , Masculino , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Técnicas de Sutura/mortalidade , Fatores de Tempo , Resultado do Tratamento
2.
J Interv Cardiol ; 31(1): 51-59, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29024080

RESUMO

OBJECTIVES: To compare the effectiveness and safety of balloon aortic valvuloplasty (BAV) performed with or without rapid ventricular pacing (RP). BACKGROUND: BAV technique is poorly standardized. METHODS: One hundred consecutive patients were randomly assigned 1:1 between BAV performed with or without RP. Exclusion criteria were an immediate indication for surgical or transcatheter aortic valve replacement, presentation in cardiogenic shock or pulmonary edema refractory to medical stabilization. RESULTS: There were 51 patients in the BAV group performed with RP, 49 in the BAV group without RP (noRP). Procedural success (50% hemodynamic gradient reduction) was achieved in 37.3% and 55.1%, respectively (P = 0.16). Fewer people in the noRP group complained of poor tolerance to the procedure (16% vs 41%). The primary efficacy endpoint, a 50% reduction in the mean echocardiographic trans-aortic gradient, was met in 21/49 patients in the noRP group compared to 20/51 in the RP (42.9% vs 39.2%; P = 0.84). No significant difference between the groups was observed in the primary safety endpoint, a 30-day composite of death, myocardial infarction, stroke, acute aortic regurgitation, and BARC bleeding ≥3 (8.2% noRP vs 13.7%; P = 0.53). The noRP group required fewer bailout temporary pacemakers (P = 0.048) and had a lower incidence of moderate/severe renal function worsening (4.1% vs 17.6%; P = 0.052). CONCLUSIONS: Rapid ventricular pacing did not influence BAV efficacy or safety and tolerance was slightly worse.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica/cirurgia , Valvuloplastia com Balão , Estimulação Cardíaca Artificial , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/instrumentação , Valvuloplastia com Balão/métodos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Ecocardiografia/métodos , Feminino , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Masculino , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 89(4): E145-E152, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26714429

RESUMO

OBJECTIVES: To evaluate the incidence, treatment, and outcomes of acute aortic regurgitation (ARR) complicating BAV. BACKGROUND: In the transcatheter aortic valve implantation (TAVI) era, there is an increase of percutaneous balloon aortic valvuloplasty (BAV) procedures with different indications. METHODS: From the prospective BAV registry of the University of Bologna, which has enrolled patients between the year 2000 and the present, we selected those who suffered intraprocedural AAR with overt hemodynamic instability. Worsening of baseline aortic insufficiency without hemodynamic collapse, treatment of degenerated biological valve prosthesis, and BAV performed within a planned TAVI procedure were excluded. The main endpoints were in-hospital and 30-day mortality. RESULTS: Out of 1517 BAVs, we identified 26 cases of AAR (1.7%). This complication occurred in 80.8% of cases after one or two balloon inflations. Mean transaortic gradient decreased from 50.6 ± 19.3 to 26.0 ± 14.4 mm Hg (p < 0.01). In 8(30.8%) patients, AAR spontaneously resolved within few minutes; in 18 cases, the operators had to perform a rescue maneuver to reposition a valve leaflet got stuck in the opening position (this maneuver was successful in 13/18 of the cases, 72.2%). Out of 5 persistent AAR, 3 were managed with emergency TAVI or surgery, while 2 were unresolved. In-hospital mortality was 15.4% (n = 4), whereas no more deaths occurred up to 30 days. CONCLUSIONS: AAR is a fearsome complication of BAV and portends a grim prognosis. In some cases, it can be resolved with appropriate technical maneuvers; in others, a rescue TAVI or surgical valve replacement may be necessary. © 2015 Wiley Periodicals, Inc.


Assuntos
Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Valvuloplastia com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias , Doença Aguda , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 87(2): 332-8, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26010724

RESUMO

OBJECTIVES: To compare the outcomes of trans-subclavian (TS) and transapical (TA) access for transcatheter aortic valve implantation (TAVI). BACKGROUND: A considerable proportion of patients undergoing TAVI are not eligible for transfemoral approach. To date, there are few data to guide the choice between alternative vascular access routes. METHODS: Among 874 consecutive patients who underwent TAVI, 202 procedures were performed through TA (n = 142, 70.3%) or TS (n = 60, 29.7%) access. Medtronic Corevalve (CV, Medtronic, Minneapolis, MN) was implanted in 17.3% of the patients, the Edwards-Sapien (ES, Edwards Lifesciences Inc., Irvine, CA) in 81.2% and other prostheses in 0.1%. In-hospital and long-term outcome were assessed using the Valve Academic Research Consortium (VARC)-2 definitions. RESULTS: Mean age was 82 ± 6 years, STS score 9.3 ± 7.9%. The 2 groups showed a relevant imbalance in baseline characteristics. In hospital mortality was 6.4% (1.7% TS vs. 8.4% TA, P = 0.06), stroke 2.0%, acute myocardial infarction 1.0%, acute kidney injury 39.4%, sepsis 4.0% with no significant differences between groups, while bleeding was more frequent in TA patients (53.5% vs. 11.7% TS, P < 0.001). One- and 2-year survival was 85.2% and 73.2% in TS patients, and 83.9% and 74.9% in TA patients (P = ns for both). Access site was not an independent predictor of mortality at multivariable analysis. CONCLUSION: Transapical compared with trans-subclavian access for TAVI was associated with a nonsignificant trend to increased periprocedural events. However, 1- and 2-year survival appears similar.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/métodos , Cateterismo Periférico/métodos , Implante de Prótese de Valva Cardíaca/métodos , Artéria Subclávia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Cateterismo Periférico/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Eur Heart J ; 36(45): 3189-98, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26333367

RESUMO

BACKGROUND: Through contemporary literature, the optimal strategy to manage coronary chronic total occlusions (CTOs) remains under debate. OBJECTIVES: The aim of the Italian Registry of Chronic Total Occlusions (IRCTO) was to provide data on prevalence, characteristics, and outcome of CTO patients according to the management strategy. METHODS: The IRCTO is a prospective real world multicentre registry enrolling patients showing at least one CTO. Clinical and angiographic data were collected independently from the therapeutic strategy [optimal medical therapy (MT), percutaneous coronary intervention (PCI), or coronary artery bypass grafting (CABG)]; a comparative 1-year clinical follow-up was performed. RESULTS: A total of 1777 patients were enrolled for an overall CTO prevalence of 13.3%. The adopted therapeutic strategies were as follows: MT in 826 patients (46.5%), PCI in 776 patients (43.7%), and CABG in the remaining 175 patients (9.8%). At 1-year follow-up, patients undergoing PCI showed lower rate of major adverse cardiac and cerebrovascular events (MACCE) (2.6% vs. 8.2% and vs. 6.9%; P < 0.001 and P < 0.01) and cardiac death (1.4% vs. 4.7% and vs. 6.3%; P < 0.001 and P < 0.001) in comparison with those treated with MT and CABG, respectively. After propensity score-matching analysis, patients treated with PCI showed lower incidence of cardiac death (1.5 vs. 4.4%; P < 0.001), acute myocardial infarction (1.1 vs. 2.9%; P = 0.03), and re-hospitalization (2.3 vs. 4.4% P = 0.04) in comparison with those managed by MT. CONCLUSIONS: Our data showed how CTO PCI might significantly improve the survival and decrease MACCE occurrence at 1 year follow-up in comparison with MT and/or CABG.


Assuntos
Oclusão Coronária/terapia , Idoso , Fármacos Cardiovasculares/uso terapêutico , Doença Crônica , Angiografia Coronária/mortalidade , Ponte de Artéria Coronária/mortalidade , Ponte de Artéria Coronária/estatística & dados numéricos , Oclusão Coronária/mortalidade , Feminino , Humanos , Itália/epidemiologia , Masculino , Intervenção Coronária Percutânea/mortalidade , Intervenção Coronária Percutânea/estatística & dados numéricos , Prevalência , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/terapia
6.
Circulation ; 128(19): 2145-53, 2013 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-24088530

RESUMO

BACKGROUND: Little is known of the prognostic significance of mitral regurgitation (MR) on transcatheter aortic valve replacement (TAVR), the impact of TAVR on MR severity, and the variables associated with possible post-TAVR improvement in MR. We evaluated these issues in a multicenter registry of patients undergoing CoreValve Revalving System-TAVR. METHODS AND RESULTS: Among 1007 consecutive patients, 670 (66.5%), 243 (24.1%), and 94 (9.3%) presented with no/mild, moderate, and severe MR, respectively. At 1 month after TAVR, patients with severe or moderate MR showed comparable mortality rates (odds ratio, 1.1; 95% confidence interval [95% CI], 0.7-1.55; P=0.2), but both were significantly higher compared with patients with mild/no MR (odds ratio, 2.2; 95% CI, 1.78-3.28; P<0.001; and odds ratio, 1.9; 95% CI, 1.1-3.3; P=0.02, respectively). One-year mortality was also similar between patients with severe and those with moderate MR (hazard ratio, 1.4; 95% CI, 0.94-2.4; P=0.06) and still significantly higher compared with patients with mild/no MR (hazard ratio, 1.7; 95% CI, 1.2-3.41; P<0.001; and hazard ratio, 1.4; 95% CI, 1.2-2.2; P=0.03, respectively). Severe pulmonary hypertension, atrial fibrillation, and MR more than mild, but not an improvement of ≥1 grade in MR severity, were independent predictors of mortality at 1 year. At 1 year, an improved MR was observed in 47% and 35% of patients with severe and moderate MR, respectively. The rate of low implantation was consistent across groups with improved, unchanged, or worsened MR. A functional type of MR and the absence of severe pulmonary hypertension and atrial fibrillation independently predicted the improvement in MR severity. CONCLUSIONS: Baseline MR greater than mild is associated with higher mortality after CoreValve Revalving System-TAVR. A significant improvement in MR was more likely in patients with functional MR and without severe pulmonary hypertension or atrial fibrillation. The improvement in MR did not independently predict mortality.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/mortalidade , Insuficiência da Valva Mitral/mortalidade , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Sistema de Registros/estatística & dados numéricos , Índice de Gravidade de Doença
7.
Am Heart J ; 168(5): 798-806, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25440810

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an effective therapeutic option for patients with severe aortic stenosis at high risk for surgery. Identification of causes of death after TAVR may help improve patient selection and outcome. METHODS: We enrolled 874 consecutive patients who underwent TAVR at 3 centers using all approved bioprostheses and different access routes. Clinical outcomes during follow-up were defined according to the Valve Academic Research Consortium 2 definitions. Causes of deaths were carefully investigated. RESULTS: Mean logistic European System for Cardiac Operative Risk Evaluation was 23.5% ± 15.3%; Society of Thoracic Surgery score, 9.0% ± 8.2%. The Corevalve (Medtronic, Minneapolis, MN) was used in 41.3%; the Edwards Sapien (Edwards Lifesciences Inc., Irvine, CA) in 57.3%. Vascular access was transfemoral in 75.7%. In-hospital mortality was 5.0%. Cumulative mortality rates at 1 to 3 years were 12.4%, 23.4%, and 31.5%, respectively. Landmark analysis showed a significantly higher incidence of cardiovascular (CV) death in the first 6 months of follow-up and a significantly higher incidence of non-CV death thereafter. At Cox regression analysis, the independent predictors of in-hospital mortality were acute kidney injury grades 2 to 3 (hazard ratio [HR] 3.41) life-threatening bleeding (HR 4.26), major bleeding (HR 4.61), and myocardial infarction (HR 3.89). The independent predictors of postdischarge mortality were chronic obstructive pulmonary disease (HR 1.48), left ventricular ejection fraction at discharge (HR 0.98), and glomerular filtration rate <30 mL/min per 1.73 m(2) (HR 1.64). CONCLUSIONS: Around a third of patients treated with TAVR in daily practice die within the first 3 years of follow-up. Early mortality is predominantly CV, whereas late mortality is mainly non-CV, and it is often due to preexisting comorbidity.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doenças Cardiovasculares/mortalidade , Substituição da Valva Aórtica Transcateter/métodos , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Estudos de Coortes , Comorbidade , Feminino , Seguimentos , Taxa de Filtração Glomerular , Hemorragia/epidemiologia , Mortalidade Hospitalar , Humanos , Masculino , Infarto do Miocárdio/epidemiologia , Seleção de Pacientes , Modelos de Riscos Proporcionais , Fatores de Risco , Volume Sistólico , Fatores de Tempo
8.
Catheter Cardiovasc Interv ; 84(6): 912-22, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24403174

RESUMO

OBJECTIVES: To examine the differences in cardiac outcomes for patients with ST-elevation myocardial infarction (STEMI) and multivessel disease (MVD) as a function of whether they underwent culprit-only primary percutaneous coronary intervention (PPCI) or multivessel PCI, either during PPCI or as a staged procedure. BACKGROUND: MVD occurs in about 40% of patients presenting with STEMI, and it has been associated with a worse outcome compared to single-vessel disease. The most favorable PCI strategy for dealing with significant nonculprit lesions has to be established. METHODS: A total of 2061 STEMI patients with MVD undergoing PPCI, prospectively enrolled in the REAL Registry between July 2002 and December 2010, were considered: 706 underwent culprit-only PPCI; 367 multivessel PCI during the index procedure; 988 had a staged PCI within 60 days. Mortality and outcomes were calculated at 30 days and 2 years. RESULTS: At multivariate analysis, culprit-only PPCI was associated with higher rates of cardiac outcomes as compared to staged multivessel PCI, taken as reference [Hazard Ratio (HR): 2.81, 95% confidence interval (CI): 1.34-5.89, P = 0.006 for 30-day mortality, and HR: 1.93, 95% CI: 1.35-2.74, P = 0.0002 for 2-year mortality, respectively]. Short-term mortality rates were higher in multivessel PCI group as compared to staged PCI group (HR: 2.58, 95% CI: 1.06-6.26, P = 0.03); no differences were observed at 2-year follow-up (HR: 1.08, 95% CI: 0.64-1.82, P = 0.76). CONCLUSIONS: Our findings support the current guidelines recommendation to perform culprit-only PPCI in STEMI patients with MVD without hemodynamic compromise, followed by a staged PCI of noninfarct-related significant lesions.


Assuntos
Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Feminino , Hemodinâmica , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
J Interv Cardiol ; 26(5): 425-33, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23962106

RESUMO

BACKGROUND: To date, no published data are available regarding long-term follow-up of new generation DES implanted in coronary artery bypass graft (CABG) lesions. OBJECTIVES: To assess the long-term clinical outcome of patients receiving the new generation Biolimus A9-coated drug-eluting stent (DES) with biodegradable polymer in saphenous vein grafts (SVG). METHODS: Three thousand sixty-seven patients were included in the NOBORI 2 registry: 71 patients with a total of 117 lesions received at least 1 biolimus A9 DES in SVG lesions and 2,959 patients received percutaneous coronary intervention in other lesions. Clinical follow-up was performed at 1, 6, and 12 months, and annually up to 3 years. RESULTS: Compared to the non-CABG group, patients with CABG lesions were older (P < 0.001), had a higher Charlson Comorbidity Index (P = 0.004), and presented more often with acute coronary syndrome (P = 0.02). At 3-year follow-up, cardiac death occurred in 9.7% versus 2.1% (P < 0.001), myocardial infarction (MI) in 8.3% versus 3.0% (P = 0.02), target lesion failure in 13.9% versus 6.4% (P = 0.03), and major adverse cardiac event in 18.1% versus 8.6% (P = 0.01). No differences were observed in TV-MI and TLR, nor stent thrombosis (ST) which was generally low in both groups (1.4% vs 0.8%, P = NS). CONCLUSION: Albeit 3-year outcomes were less favorable in the CABG group, the higher cardiac mortality was apparently not driven by ST, target vessel MI, or TLR, but is likely due to advanced disease and age as well as comorbidity. The low TLR rate as well as the absence of late and very late ST suggest that BES are safe and effective for the treatment of CABG lesions.


Assuntos
Implantes Absorvíveis , Ponte de Artéria Coronária , Stents Farmacológicos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Veia Safena , Resultado do Tratamento
10.
Cardiology ; 124(2): 97-104, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23391968

RESUMO

OBJECTIVES: To investigate the prognostic significance of baseline white blood cell count (WBCc) in non-ST-segment elevation acute coronary syndrome (NSTE-ACS) and its additive predictive value beyond the Global Registry of Acute Coronary Events (GRACE) score. METHODS: We included 1,315 consecutive NSTE-ACS patients. Patients were divided in quartiles according to the WBCc (cells per 1 mm(3)) i.e. Q1 <6,850, Q2 = 6,850-8,539, Q3 = 8,540-10,857 and Q4 ≥10,858. The study end point was 3-year cardiovascular death (CVD). RESULTS: The median age of the study population was 76 years. Overall, 335 patients (25.5%) died with 211 of these (16%) suffering from CVD. Patients in Q4 showed a higher cumulative probability of CVD compared to patients in Q1-Q3. On multivariable analysis, patients in Q4 were at higher risk of CVD [hazard ratio (HR) = 1.47, 95% confidence interval (CI) 1.09-1.98, p = 0.011]. WBCc as a continuous variable was also independently associated with the study end point (HR = 1.043; 95% CI 1.02-1.07; p = 0.001). However, the incorporation of WBCc into the GRACE score did not improve either prediction of risk (C-index = 0.796 for GRACE score with or without WBCc) or classification of risk [relative integrated discrimination improvement = 0.0154, 95% CI) -0.029 to 0.0618; continuous net reclassification improvement = -0.0676, 95% CI -0.2149-0.0738). CONCLUSIONS: WBCc was an independent predictor of 3-year CVD in patients with NSTE-ACS. However, it did not add prognostic information beyond the GRACE score.


Assuntos
Síndrome Coronariana Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Doenças Cardiovasculares/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Contagem de Leucócitos , Masculino , Prognóstico , Medição de Risco/métodos
11.
Eur Heart J ; 33(8): 969-76, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22240494

RESUMO

AIMS: The paucity of evidences about the long-term durability of currently available transcatheter prostheses is one of the main issues of transcatheter aortic valve implantation (TAVI). We sought to assess 3-year clinical and echocardiographic outcomes of patients undergoing TAVI with the third generation CoreValve prosthesis (Medtronic Incorporation, MN, USA). METHODS AND RESULTS: From the Italian CoreValve registry, 181 who underwent TAVI from June 2007 to August 2008 and eligible for 3-year follow-up were analysed. All outcomes were defined according to the Valve Academic Research Consortium. All-cause mortality at 1, 2, and 3 years was 23.6, 30.3, and 34.8%, respectively. Cardiovascular death at 1, 2, and 3 years was 11.2, 12.1, and 13.5%, respectively. The actuarial survival free from a composite of death, major stroke, myocardial infarction, and life-threatening bleeding was 69.6% at 1 year, 63.5% at 2 years, and 59.7% at 3 years. Patients with renal insufficiency had a higher mortality at 3-year follow-up (49.0 vs. 29.2%, P = 0.007); moreover, patients experiencing post-procedural major or life-threatening bleeding had a higher rate of mortality already seen at 30 days (21.6 vs. 2.8%; P < 0.001) and this result was sustained at 3-year follow-up (62.2 vs. 27.7%; P < 0.001). Mean pressure gradients decreased from 52.2 ± 18.1 mmHg (pre-TAVI) to 10.3 ± 3.1 mmHg (1-year post-TAVI) (P < 0.001); aortic valve area increased from 0.6 ± 0.2 cm(2) (pre-TAVI) to 1.8 ± 0.4 cm(2) (1-year post-TAVI); these results remained stable over the 3 years of follow-up. Paravalvular leak was observed in the majority of patients. There were no cases of progression to moderate or severe regurgitation. No cases of structural valve deterioration were observed. CONCLUSION: This multicentre study demonstrates that TAVI with the 18-Fr CoreValve ReValving System is associated with sustained clinical and functional cardiovascular benefits in high-risk patients with symptomatic aortic stenosis up to 3-year follow-up. Non-cardiac causes accounted for the majority of deaths at follow-up.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Estenose da Valva Aórtica/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Infarto do Miocárdio/mortalidade , Hemorragia Pós-Operatória/mortalidade , Estudos Prospectivos , Desenho de Prótese , Acidente Vascular Cerebral/mortalidade , Resultado do Tratamento
12.
Circulation ; 123(3): 299-308, 2011 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-21220731

RESUMO

BACKGROUND: There is a lack of information on the incidence and predictors of early mortality at 30 days and late mortality between 30 days and 1 year after transcatheter aortic valve implantation (TAVI) with the self-expanding CoreValve Revalving prosthesis. METHODS AND RESULTS: A total of 663 consecutive patients (mean age 81.0 ± 7.3 years) underwent TAVI with the third generation 18-Fr CoreValve device in 14 centers. Procedural success and intraprocedural mortality were 98% and 0.9%, respectively. The cumulative incidences of mortality were 5.4% at 30 days, 12.2% at 6 months, and 15.0% at 1 year. The incidence density of mortality was 12.3 per 100 person-year of observation. Clinical and hemodynamic benefits observed acutely after TAVI were sustained at 1 year. Paravalvular leakages were trace to mild in the majority of cases. Conversion to open heart surgery (odds ratio [OR] 38.68), cardiac tamponade (OR 10.97), major access site complications (OR 8.47), left ventricular ejection fraction <40% (OR 3.51), prior balloon valvuloplasty (OR 2.87), and diabetes mellitus (OR 2.66) were independent predictors of mortality at 30 days, whereas prior stroke (hazard ratio [HR] 5.47), postprocedural paravalvular leak ≥ 2+ (HR 3.79), prior acute pulmonary edema (HR 2.70), and chronic kidney disease (HR 2.53) were independent predictors of mortality between 30 days and 1 year. CONCLUSIONS: Benefit of TAVI with the CoreValve Revalving System is maintained over time up to 1 year, with acceptable mortality rates at various time points. Although procedural complications are strongly associated with early mortality at 30 days, comorbidities and postprocedural paravalvular aortic regurgitation ≥ 2+ mainly impact late outcomes between 30 days and 1 year.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Incidência , Masculino , Valor Preditivo dos Testes , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo
13.
Am Heart J ; 163(5): 835.e1-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22607870

RESUMO

BACKGROUND: The optimal antiplatelet regimen in elective patients undergoing complex percutaneous coronary interventions (PCIs) is uncertain. We aimed to assess the impact of glycoprotein IIb/IIIa (GpIIb/IIIa) inhibition with eptifibatide in clinically stable subjects with diffuse coronary lesions. METHODS: Patients with stable coronary artery disease undergoing PCI by means of implantation of >33 mm of drug-eluting stent were single-blindedly randomized to heparin plus eptifibatide versus heparin alone. The primary end point was the rate of abnormal post-PCI creatine kinase-MB mass values. Secondary end points were major adverse cardiovascular events (MACEs) (ie, cardiac death, myocardial infarction, or urgent revascularization) and MACE plus bailout GpIIb/IIIa inhibitor use. RESULTS: The study was stopped for slow enrollment and funding issues after including a total of 91 patients: 44 were randomized to heparin plus eptifibatide, and 47, to heparin alone. Analysis for the primary end point showed a trend toward lower rates of abnormal post-PCI creatine kinase-MB mass values in the heparin-plus-eptifibatide group (18 [41%]) versus the heparin-alone group (26 [55%], relative risk 0.74 [95% CI 0.48-1.15], P = .169). Similar nonstatistically significant trends were found for rates of MACE, their components, or MACE plus bailout GpIIb/IIIa inhibitors (all P > .05). Notably, heparin plus eptifibatide proved remarkably safe because major bleedings or minor bleeding was uncommon and nonsignificantly different in both groups (all P > .05). CONCLUSIONS: Given its lack of statistical power, the INSTANT study cannot definitively provide evidence against or in favor of routine eptifibatide administration in stable patients undergoing implantation of multiple drug-eluting stent for diffuse coronary disease. However, the favorable trend evident for the primary end point warrants further larger randomized studies.


Assuntos
Angioplastia Coronária com Balão/métodos , Estenose Coronária/terapia , Stents Farmacológicos , Infarto do Miocárdio/prevenção & controle , Peptídeos/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Eptifibatida , Feminino , Seguimentos , Heparina/administração & dosagem , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Inibidores da Agregação Plaquetária/administração & dosagem , Modelos de Riscos Proporcionais , Medição de Risco , Índice de Gravidade de Doença , Método Simples-Cego , Estatísticas não Paramétricas , Análise de Sobrevida , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 79(2): 315-21, 2012 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21523882

RESUMO

OBJECTIVES: To assess safety and effectiveness of balloon aortic valvuloplasty (BAV) in patients with symptomatic severe aortic stenosis (AS) and significant aortic regurgitation. BACKGROUND: BAV is a palliative procedure that has possibly been underused in patients with symptomatic AS not suitable for surgical aortic valve replacement or transcatheter aortic valve implantation. Significant aortic regurgitation is commonly perceived as a contraindication to BAV. METHODS: Among 416 consecutive patients undergoing BAV at our Institution, 73 patients showed moderate or severe AR before the procedure. Demographics and baseline characteristics, as well as in-hospital clinical outcome, have been prospectively collected in a dedicated database. Transthoracic echocardiography was regularly performed in all patients undergoing BAV before the procedure and at hospital discharge. RESULTS: Patients had a high-risk profile, confirmed by advanced age (77.2 ± 11.8 years) and important comorbidity (logistic Euroscore 26.5 ± 16.3%). Advanced heart failure was present in 73.9%. Indication to BAV was cardiogenic shock in 9.6%, palliation in 31.5%, bridge in 58.9% of the patients. BAV was performed with standard retrograde approach. Aortic valve area increased from 0.62 ± 0.15 cm(2) at baseline to 0.83 ± 0.17 cm(2) before discharge (P < 0.001). The degree of AR was improved or unchanged in 65 patients (89%). In-hospital mortality was 6.9%, mainly limited to terminal patients. Symptomatic status at discharge was improved in all surviving patients. Acute AR occurred in seven patients; in five of them it was successfully resolved in the catheterization laboratory. CONCLUSIONS: When clinically indicated, BAV can be safely performed in patients with combined aortic stenosis and significant aortic regurgitation.


Assuntos
Insuficiência da Valva Aórtica/terapia , Cateterismo/métodos , Idoso , Insuficiência da Valva Aórtica/diagnóstico , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Cuidados Paliativos , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 79(5): 712-9, 2012 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-22109957

RESUMO

OBJECTIVE: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis. BACKGROUND: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM. METHODS: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge. RESULTS: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 ± 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 ± 12.8%, STS score 9.4 ± 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.32-0.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.03-1.83). CONCLUSIONS: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Bioprótese , Estimulação Cardíaca Artificial/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Ligas , Análise de Variância , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Estudos de Coortes , Ecocardiografia Doppler/métodos , Eletrocardiografia/métodos , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Itália , Modelos Logísticos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Análise Multivariada , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/terapia , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
16.
Med Phys ; 38(4): 2168-75, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21626950

RESUMO

PURPOSE: Recent recommendations of the International Commission on Radiological Protection state that the use of effective dose (E) for assessing patient exposure has severe limitations, though it can be kept for dose comparisons. In cardiology procedures, the equivalent dose (H(T)) is one of the most appropriate dose quantity to be evaluated for risk-benefit assessment. In this study, both E and H(T) values for ten critical organs in coronary angiography (CA) and percutaneous coronary interventions (PCI) were derived from in-the-field dose-area-product (DAP) measurements in order to provide a database for doses in those procedures. METHODS: Conversion factors E/DAP calculated by Monte Carlo methods in two different mathematical human phantoms were applied to DAP values measured on 193 patients (118 CA and 75 PCI). Partial DAP values were recorded in-the-field for each projection and for all patients. The partial effective doses of all projections were summed up to calculate the E of the entire procedure. Similarly, equivalent doses for ten critical organs/tissues (bone, colon, heart, liver, lung, esophagus, red bone marrow, skin, stomach, and thyroid) were derived from H(T)/DAP conversion factors for different projections calculated by Monte Carlo method. RESULTS: All parameters related to the patient dose, i.e., fluoroscopy times, number of images, DAP, effective doses, and equivalent doses, show a wide range of values depending on the complexity of the patient case and the experience of the cardiologist. The mean fluoroscopy time, DAP, and E values for coronary angiography patients were approximately threefold lower than those for PCI patients; the number of images for CA was half that for PCI. The correlation between effective dose and DAP was excellent for both CA and PCI. The equivalent doses values were in good correlations with DAP values in CA examinations, with Pearson's coefficients ranging from 0.87 (stomach) to 0.99 (skin) and r(mean) = 0.94. The same analysis was performed for PCI procedures. In this case, the trends were only slightly worse because "r" ranged from 0.70 (stomach) to 0.92 (bone) and r(mean) = 0.85. Simple conversion coefficients to estimate equivalent doses to ten critical organs/tissues from DAP values, for both CA and PCI, were provided for avoiding the need to carry out detailed in-the-field analysis for all projections and for all patients. CONCLUSIONS: Measurements in-the-field of DAP values were carried out for two common cardiology procedures and effective doses were derived for each technique from detailed analysis of dose and projection data, using conversion factors provided by two different theoretical models. Equivalent doses to organs/tissues were also calculated using conversion factors proposed in the literature for different projections and cumulative conversion factors (H)T/DAP for ten organs/tissues were estimated.


Assuntos
Angioplastia/métodos , Angiografia Coronária/métodos , Doses de Radiação , Idoso , Feminino , Humanos , Masculino
17.
Am Heart J ; 160(6 Suppl): S16-21, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21147287

RESUMO

Primary percutaneous coronary intervention (PCI) decreases myocardial damage and reduces the occurrence of mechanical complications and acute heart failure in patients with ST elevation myocardial infarction (STEMI). Nevertheless, left ventricular (LV) dysfunction remains the leading cause of in-hospital mortality in all subsets of patients and particularly for those in whom primary PCI fails to reopen the infarct-related artery. The clinical scenarios of acute LV failure are heart failure and cardiogenic shock, both conditions being associated with extremely poor outcomes. It has been estimated that LV failure accounts for >75% of the cases of shock complicating acute STEMI. As compared to similar situations, the decision-making process in these patients can potentially benefit from the known coronary anatomy and, in many instances, from the immediate implantation of an intraaortic balloon pump at the time of PCI in selected groups of patients. A thorough clinical and instrumental evaluation is mandatory to discriminate patients who will likely recover (either spontaneously or with further conventional procedures) from those who have irreversible myocardial injury and should be screened for LV assist devices and/or emergent heart transplantation. In this review, we provide a practical diagnostic and therapeutic algorithm that may be helpful for the clinical management of patients with acute LV failure after primary PCI.


Assuntos
Angioplastia Coronária com Balão , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Disfunção Ventricular Esquerda/terapia , Doença Aguda , Algoritmos , Procedimentos Cirúrgicos Cardíacos , Fármacos Cardiovasculares/uso terapêutico , Insuficiência Cardíaca/etiologia , Transplante de Coração , Coração Auxiliar , Humanos , Balão Intra-Aórtico , Prognóstico , Fatores de Tempo , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/etiologia
18.
Catheter Cardiovasc Interv ; 75(3): 327-34, 2010 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-19937776

RESUMO

BACKGROUND: Long-term outcomes of percutaneous coronary interventions (PCI) with sirolimus-eluting stents (SES) compared to paclitaxel-eluting-stents (PES) in unselected diabetics in routine practice is still debated. OBJECTIVE: This study compared the 2-year incidence of MACE (all-cause mortality, nonfatal myocardial infarction and target vessel revascularization) of SES and PES in a real-world setting of patients with diabetes. DESIGN: Observational, multicenter, nonrandomized study. SETTING: Prospective web-based registry (REAL Registry; study period, 2002-2005) comprising all 13 hospitals performing PCI. PATIENTS: Among the 945 eligible patients treated with either SES alone (n = 606) or PES alone (n = 339), 29% were insulin-requiring, 72% had multivessel coronary disease, 26% had prior myocardial infarction and 10% had poor left ventricular function. MEASUREMENTS: Unadjusted and propensity score-adjusted 2-year clinical outcome. RESULTS: After propensity score adjustment, 2-year MACE incidence in the SES and PES groups was equivalent (23.3% vs. 23.7%, HR 1.01, 95%CI 0.72-1.42, P = 0.96). Adjusted 2-year angiographic stent thrombosis occurred in 1.1% of the SES patients versus 2.6% of the PES patients (P = 0.15). In this large, real-world, diabetic population treated with DES, there was no difference in outcome between SES and PES. Further studies are needed to demonstrate the long-term safety of different types of DES in patients with diabetes.


Assuntos
Doença da Artéria Coronariana/terapia , Diabetes Mellitus , Stents Farmacológicos , Imunossupressores/administração & dosagem , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão , Angiografia Coronária , Feminino , Humanos , Internet , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Sistema de Registros , Estudos Retrospectivos
19.
Eur Heart J ; 30(1): 33-43, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18996956

RESUMO

AIMS: To evaluate the clinical impact of early administration of glycoprotein IIb/IIIa agents (IIb/IIIa agents) in the context of a dedicated hub and spoke network allowing very prompt pharmacological/mechanical interventions. METHODS AND RESULTS: Using a prospective database, we conducted a cohort study of ST-elevation myocardial infarction (STEMI) patients (n = 1124) undergoing primary percutaneous coronary interventions (PPCIs) and IIb/IIIa agents administration (period, 2003-2006). Comparisons were planned between patients receiving early IIb/IIIa agents administration (in hub/spoke centre emergency departments or during ambulance transfer; early group, n = 380) or delayed administration (in the catheterization laboratory; late group, n = 744). The primary outcome measure was long-term overall mortality/re-infarction. Baseline characteristics of the two groups were largely comparable. Angiographically, early group patients more often achieved pre-PPCI TIMI Grade 2-3 and TIMI Grade 3 flow. Clinically, the early administration group experienced lower 2-year risk of unadjusted mortality/re-infarction (17 vs. 23%; P = 0.01). After adjustment for potential confounders, early administration was associated with favourable outcome in the overall population (HR = 0.71, P = 0.03) and in high-risk subgroups (TIMI risk index >25, HR = 0.64, P = 0.02; Killip class >1, HR = 0.54, P = 0.01). CONCLUSION: In patients treated by PPCI within a STEMI network setting, early administration of IIb/IIIa agents may provide long-term clinical benefits. Notably, these results appeared magnified in high-risk patients.


Assuntos
Angioplastia Coronária com Balão/métodos , Infarto do Miocárdio/tratamento farmacológico , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Terapia Trombolítica/métodos , Idoso , Angiografia Coronária , Bases de Dados Factuais , Emergências , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Estudos Retrospectivos , Resultado do Tratamento
20.
Eur Heart J ; 30(10): 1171-9, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19276194

RESUMO

AIMS: To compare long-term clinical outcome following drug-eluting stents (DES) or bare-metal stents (BMS) implantation on lesions located at the ostium or the shaft of the left main in a large real-world population. The advent of DES decreased the risk of unprotected left main coronary artery (ULMCA) restenosis when compared with BMS, but it is unclear if this advantage continues when non-bifurcational lesions are considered. METHODS AND RESULTS: The GISE-SICI registry is a retrospective, observational multicentre registry promoted by the Italian Society of Invasive Cardiology in which 19 high-volume participating centres enrolled 1453 consecutive patients who underwent percutaneous coronary intervention on ULMCA between January 2002 and December 2006. From the registry, a total of 479 consecutive patients with ostial and shaft lesions who underwent DES (n = 334) or BMS (n = 145) implantation were analysed with extensive multivariable and propensity score adjustments. At 3-year follow-up, risk-adjusted survival rates were higher in patients treated with DES than in those treated with BMS. The adjusted hazard ratio (HR) for the risk of mortality after DES implantation relative to BMS implantation was 0.37 (95% CI: 0.15-0.96, P = 0.04). The adjusted HR for the risk of cardiac mortality was 0.31 (95% CI: 0.09-1.04, P = 0.06). The adjusted 3-year rates of target lesion revascularization (TLR) were not significantly lower in the DES group than in the BMS group (P = 0.60). CONCLUSION: In a large population of patients with lesions located at the ostium or the shaft of the left main in a real-world setting, DES were associated with favourable clinical outcomes when compared with BMS, although there was no evidence of a significant reduction in TLR with DES vs. BMS.


Assuntos
Doença da Artéria Coronariana/terapia , Reestenose Coronária/prevenção & controle , Stents , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/mortalidade , Reestenose Coronária/patologia , Vasos Coronários/patologia , Stents Farmacológicos , Métodos Epidemiológicos , Feminino , Humanos , Itália , Masculino , Metais , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA