J Am Coll Cardiol ; 42(8): 1475-83, 2003 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-14563595

RESUMO

OBJECTIVES: The goal of this study was to examine the effect of acute beta-blockade on dipyridamole Tc-99m sestamibi myocardial perfusion imaging (DMPI). BACKGROUND: Studies suggest that antianginal drugs may reduce the presence and severity of myocardial perfusion defects with dipyridamole stress. However, there are no data regarding specific drugs. METHODS: Patients with catheterization-proven coronary artery disease (CAD) were enrolled in this prospective, double-blind, placebo-controlled study and randomly assigned to DMPI after placebo, low-dose metoprolol (up to 10 mg), and high-dose metoprolol (up to 20 mg). Patients underwent one Tc-99m sestamibi study at rest on a separate day. The interval between DMPI studies was

Assuntos
Antagonistas Adrenérgicos beta/farmacologia , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Dipiridamol , Hemodinâmica/efeitos dos fármacos , Metoprolol/farmacologia , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Vasodilatadores , Antagonistas Adrenérgicos beta/administração & dosagem , Método Duplo-Cego , Teste de Esforço , Feminino , Humanos , Masculino , Metoprolol/administração & dosagem , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos
2.
J Nucl Cardiol ; 12(6): 676-86, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16344230

RESUMO

BACKGROUND: Nonuniform attenuation artifacts cause suboptimal specificity of stress single photon emission computed tomography (SPECT) myocardial perfusion images. In phantoms, normal subjects, and patients suspected of having coronary artery disease (CAD), we evaluated a new hybrid attenuation correction (AC) system that combines x-ray computed tomography (CT) with conventional stress SPECT imaging. METHODS AND RESULTS: The effect of CT-based AC was evaluated in phantoms by assessing homogeneity of normal cardiac inserts. AC improved homogeneity of normal cardiac phantoms from 11% +/- 2% to 5% +/- 1% (P < .001). Attenuation-corrected normal patient files were created from 37 normal subjects with a low likelihood (<3%) of CAD. The diagnostic performance of AC for detection of CAD was evaluated in 118 patients who had stress technetium 99m sestamibi or tetrofosmin stress SPECT imaging and coronary angiography. SPECT images with and without AC were interpreted by 4 blinded readers with different interpretative attitudes. Overall, AC improved the diagnostic performance of all readers, particularly the normalcy rate. The degree of improvement depended on interpretative attitude. Readers prone to high sensitivity or with less experience had the greatest gain in the normalcy rate, whereas a reader prone to higher specificity had improvements in sensitivity and specificity but not the normalcy rate. Importantly, improvement of one diagnostic variable was not associated with worsening of other variables. CONCLUSION: CT-based AC of SPECT images consistently improved overall diagnostic performance of readers with different interpretive attitudes and experience. CT-based AC is well suited for routine use in clinical practice.


Assuntos
Angiografia/estatística & dados numéricos , Artefatos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Aumento da Imagem/métodos , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Estados Unidos/epidemiologia