Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Nano Lett ; 24(2): 708-714, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38165767

RESUMO

Angle-dependent next-generation displays have potential applications in 3D stereoscopic and head-mounted displays, image combiners, and encryption for augmented reality (AR) and security. Metasurfaces enable such exceptional functionalities with groundbreaking achievements in efficient displays over the past decades. However, limitations in angular dispersion control make them unfit for numerous nanophotonic applications. Here, we propose a spin-selective angle-dependent all-dielectric metasurface with a unique design strategy to manifest distinct phase information at different incident angles of light. As a proof of concept, the phase masks of two images are encoded into the metasurface and projected at the desired focal plane under different angles of left circularly polarized (LCP) light. Specifically, the proposed multifunctional metasurface generates two distinct holographic images under LCP illumination at angles of +35 and -35°. The presented holographic displays may provide a feasible route toward multifunctional meta-devices for potential AR displays, encrypted imaging, and information storage applications.

2.
Blood Cells Mol Dis ; 105: 102823, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38241949

RESUMO

Peripheral blood smear examination is one of the basic steps in the evaluation of different blood cells. It is a confirmatory step after an automated complete blood count analysis. Manual microscopy is time-consuming and requires professional laboratory expertise. Therefore, the turn-around time for peripheral smear in a health care center is approximately 3-4 hours. To avoid the traditional method of manual counting under the microscope a computerized automation of peripheral blood smear examination has been adopted, which is a challenging task in medical diagnostics. In recent times, deep learning techniques have overcome the challenges associated with human microscopic evaluation of peripheral smears and this has led to reduced cost and precise diagnosis. However, their application can be significantly improved by the availability of annotated datasets. This study presents a large customized annotated blood cell dataset (named the Bio-Net dataset from healthy individuals) and blood cell detection and counting in the peripheral blood smear images. A mini-version of the dataset for specialized WBC-based image processing tasks is also equipped to classify the healthy and mature WBCs in their respective classes. An object detection algorithm called You Only Look Once (YOLO) with a refashion disposition has been trained on the novel dataset to automatically detect and classify blood cells into RBCs, WBCs, and platelets and compare the results with other publicly available datasets to highlight the versatility. In short the introduction of the Bio-Net dataset and AI-powered detection and counting offers a significant potential for advancement in biomedical research for analyzing and understanding biological data.


Assuntos
Processamento de Imagem Assistida por Computador , Leucócitos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Eritrócitos , Algoritmos , Plaquetas
3.
Opt Express ; 32(3): 4102-4110, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38297618

RESUMO

In this manuscript, what we believe to be a novel hyperbolic-graded topological nano-photonic resonator structure is proposed to excite robust topological edge states. The graded refractive index is realized by considering a porous silicon material having a deliberately modulated local refractive index. The introduction of grading effectively modifies its dispersion characteristics leading to distinctive topological properties. This results in excitation of a topologically protected edge state (TES) having significantly higher interface electric field intensity at an operational wavelength of 1521 nm. Additionally, the impact of interface layer thicknesses on the excitation of these TES is thoroughly investigated. Finally, the structure's capability to be used as a refractive index sensor is also demonstrated. The analytical results demonstrate an average sensitivity of 852.14 nm/RIU, coupled with a quality factor of 4019.23 and a figure of merit (FOM) of 1277.13 RIU-1. With its remarkable performance metrics, the proposed device holds significant promise for accurately detecting and sensing biochemical samples with very high efficiency.

4.
Nano Lett ; 23(4): 1195-1201, 2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36622968

RESUMO

Metasurfaces have shown remarkable potential to manipulate many of light's intrinsic properties, such as phase, amplitude, and polarization. Recent advancements in nanofabrication technologies and persistent efforts from the research community result in the realization of highly efficient, broadband, and multifunctional metasurfaces. Simultaneous control of these characteristics in a single-layered metasurface will be an apparent technological extension. Here, we demonstrate a broadband multifunctional metasurface platform with the unprecedented ability to independently control the phase profile for two orthogonal polarization states of incident light over dual-wavelength spectra (ultraviolet to visible). In this work, multiple single-layered metasurfaces composed of bandgap-engineered silicon nitride nanoantennas are designed, fabricated, and optically characterized to demonstrate broadband multifunctional light manipulation ability, including structured beam generation and meta-interferometer implementation. We envision the presented metasurface platform opening new avenues for broadband multifunctional applications including ultraviolet-visible spectroscopy, spatially modulated illumination microscopy, optical data storage, and information encoding.

5.
Sensors (Basel) ; 22(21)2022 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-36365810

RESUMO

There is a great demand for human-machine interfaces (HMIs) in emerging electronics applications. However, commercially available plastic-based HMIs are primarily rigid, application-specific, and hard to recycle and dispose of due to their non-biodegradability. This results in electronic and plastic waste, potentially damaging the environment by ending up in landfills and water resources. This work presents a green, capacitive pressure-sensitive (CPS), touch sensor-based keypad as a disposable, wireless, and intelligent HMI to mitigate these problems. The CPS touch keypads were fabricated through a facile green fabrication process by direct writing of graphite-on-paper, using readily available materials such as paper and pencils, etc. The interdigitated capacitive (IDC) touch sensors were optimized by analyzing the number of electrode fingers, dimensions, and spacing between the electrode fingers. The CPS touch keypad was customized to wirelessly control a robotic arm's movements based on the touch input. A low-pressure touch allows slow-speed robotic arm movement for precision movements, and a high-pressure touch allows high-speed robotic arm movement to cover the large movements quickly. The green CPS touch keypad, as a disposable wireless HMI, has the potential to enforce a circular economy by mitigating electronic and plastic waste, which supports the vision of a sustainable and green world.


Assuntos
Grafite , Tato , Humanos , Eletrodos , Eletrônica , Plásticos
6.
Sensors (Basel) ; 22(20)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36298240

RESUMO

The role of humidity sensors in different industries and field applications, such as agriculture, food monitoring, biomedical equipment, heating, and ventilation, is well known. However, most commercially available humidity sensors are based on polymers or electronic materials that are not degradable and thus contribute to electronic waste. Here, we report a low-cost, flexible, easy-to-fabricate, and eco-friendly parallel-plate capacitive humidity sensor for field applications. The sensor is fabricated from copper tape and tissue paper, where copper tape is used to create the plates of the capacitor, and tissue paper is used as a dielectric sensing layer. Along with the low cost, the high sensitivity, better response and recovery times, stability, and repeatability make this sensor unique. The sensor was tested for relative humidity (RH), ranging from 40% to 99%, and the capacitance varied linearly with RH from 240 pF to 720 pF, as measured by an Arduino. The response time of the sensor is ~1.5 s, and the recovery time is ~2.2 s. The experiment was performed 4-5 times on the same sensor, and repeatable results were achieved with an accuracy of ±0.1%. Furthermore, the sensor exhibits a stable response when tested at different temperatures. Due to the above advantages, the presented sensor can find ready applications in different areas.


Assuntos
Cobre , Eletrônica , Umidade , Capacitância Elétrica , Polímeros
7.
IEEE Trans Pattern Anal Mach Intell ; 46(2): 1148-1164, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37934645

RESUMO

Data augmentation is an effective method to improve model robustness and generalization. Conventional data augmentation pipelines are commonly used as preprocessing modules for neural networks with predefined heuristics and restricted differentiability. Some recent works indicated that the differentiable data augmentation (DDA) could effectively contribute to the training of neural networks and the augmentation policy searching strategies. Some recent works indicated that the differentiable data augmentation (DDA) could effectively contribute to the training of neural networks and the searching of augmentation policy strategies. This survey provides a comprehensive and structured overview of the advances in DDA. Specifically, we focus on fundamental elements including differentiable operations, operation relaxations, and gradient estimations, then categorize existing DDA works accordingly, and investigate the utilization of DDA in selected of practical applications, specifically neural augmentation networks and differentiable augmentation search. Finally, we discuss current challenges of DDA and future research directions.

8.
Sci Rep ; 14(1): 14393, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38909056

RESUMO

This study presents a novel method leveraging surface wave-assisted photonic spin Hall effect (PSHE) to construct physical unclonable functions (PUFs). PUFs exploit inherent physical variations to generate unique Challenge-Response pairs, which are critical for hardware security and arise from manufacturing discrepancies, device characteristics, or timing deviations. We explore PSHE generation-based PUF design, expanding existing design possibilities. With recent applications in precise sensing and computing, PSHE offers promising performance metrics for our proposed PUFs, including an inter-Hamming distance of 47.50% , an average proportion of unique responses of 62.5% , and a Pearson correlation coefficient of - 0.198. The PUF token demonstrates robustness to simulated noise. Additionally, we evaluate security using a machine learning-based attack model, employing a multi-layer perceptron (MLP) regression model with a randomized search method. The average accuracy of successful attack prediction is 9.70% for the selected dataset. Our novel PUF token exhibits high non-linearity due to the PSHE effect, resilience to MLP-based attacks, and sensitivity to process variation.

9.
Sci Rep ; 14(1): 175, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38167911

RESUMO

This work presents a dielectric material-based optical Tamm state (OTS) excitation technique with modified dispersion characteristics for photonic spin hall effect (PSHE) enhancement. The dispersion analysis of the structure is carried out to validate OTS's localization and corresponding PSHE generation for a given polarization at 632.8 nm incident wavelength. The exceptional points are optimized by considering thickness-dependent angular dispersion analysis. PSHE-based transverse displacement (PSHE-TD) is dependent on the defect layer thickness. The optimized structure provides 10.73 [Formula: see text] (or 6.78 [Formula: see text]m) PSHE-TD at an incidence angle of 41.86[Formula: see text]. The PSHE-TD of the optimized structure is sufficiently high due to the much narrower resonance than the plasmonic-based structures. Further, the structure's potential to function as a PSHE-TD-based optical sensor is assessed. The optimized structure shows an analytical average sensitivity of about 43,789 [Formula: see text]m/RIU showing its capability to detect the analytes with refractive index variations in the [Formula: see text] range. The structure demonstrates a three-time sensitivity improvement compared to similar resonance designs. Considering only dielectric materials in the proposed structure and considerably enhanced PSHE-TD, the development of highly efficient PSHE-TD-assisted commercial structures is anticipated.

10.
J Colloid Interface Sci ; 669: 458-465, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38723534

RESUMO

This article investigates the performance of a contact-mode Triboelectric Nanogenerator (TENG) utilizing polydimethylsiloxane (PDMS) with nano gratings as a dielectric in a metal-dielectric configuration. The evaluation encompasses the impact of gratings, tapping frequency, various load conditions, and contact area on the TENG performance. The fabrication involves spin-coating PDMS onto a master mold to create the device. Experimental measurements reveal a significant enhancement of 97% in open-circuit voltage by introducing gratings on PDMS. Furthermore, as the tapping frequency increases from 1 Hz to 3 Hz, there is a corresponding rise of 108% in output voltage. The influence of load resistance on TENG output performance demonstrates its ability to drive different loads efficiently. Moreover, enlarging the contact area of the device substantially increases the open-circuit voltage. A device with a 400 mm2 contact area can generate a voltage of 80 V at a low frequency of 3 Hz, indicating the importance of considering device size and contact area for specific applications. A practical circuit integrating a TENG with a full-wave bridge rectifier demonstrates energy harvesting capabilities by successfully illuminating a light-emitting diode (LED) and charging various capacitors. The fabricated devices exhibit better performance along with a cost-effective and easy fabrication process.

11.
Heliyon ; 10(7): e29091, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38596139

RESUMO

Carbon electrode-based perovskite solar cells (c-PSCs) without a hole transport layer (HTL) have obtained a significant interest owing to their cost-effective, stable, and simplified structure. However, their application is limited by low efficiency and the prevalence of high-temperature processed electron transport layer (ETL), e.g. TiO2, which also has poor optoelectronic properties, including low conductivity and mobility. In this study, a series of organic materials, namely PCBM ((Park et al., 2023; Park et al., 2023) [6,6]-phenyl-C61-butyric acid methyl ester, C72H14O2), Alq3 (Al(C9H6NO)3), BCP (2,9-Dimethyl-4,7-diphenyl-1,10-phenanthroline, C26H20N2), C60, ICBA (indene-C60 bisadduct, C78H16) and PEIE (poly (ethylenimine) ethoxylated, (C37H24O6N2)n) have been numerically analyzed in SCAPS-1D solar simulator to explore alternative potential ETL materials for HTL-free c-PSCs. The presented device has FTO/ETL/CH3NH3PbI3/carbon structure, and its performance is optimized based on significant design parameters. The highest achieved PCEs for PCBM, Alq3, BCP, C60, ICBA, and PEIE-based devices are 22.85%, 19.08%, 20.99%, 25.51%, 23.91%, and 22.53%, respectively. These PCEs are obtained for optimum absorber thickness for each case, with an acceptor concentration of 1.0 × 1017 cm-3 and defect density of 2.5 × 1013 cm-3. The C60-based cell has been found to outperform with device parameters as Voc of 1.29 V, Jsc of 23.76 mA/cm2, and FF of 82.67%. As the design lacks stability when only organic materials are employed, each of the presented devices have been analyzed by applying BiI3, LiF, and ZnO as protective layers with the performances not compromised. We believe that our obtained results will be of great interest in developing stable and efficient HTL-free c-PSCs.

12.
Sci Rep ; 13(1): 1431, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36697424

RESUMO

In this manuscript, a novel photonic crystal resonator (PhCR) structure having an exponentially graded refractive index profile is proposed to regulate and alter the dispersion characteristics for the first time. The structure comprises silicon material, where porosity is deliberately introduced to modulate the refractive index profile locally. The structural parameters are optimized to have a resonant wavelength of 1550 nm. Further, the impact of various parameters like incidence angle, defect layer thickness, and analyte infiltration on device performance is evaluated. Finally, the sensing capability of the proposed structure is compared with the conventional step index-based devices. The proposed structure exhibits an average sensitivity of 54.16 nm/RIU and 500.12 nm/RIU for step index and exponentially graded index structures. This exhibits the generation of a lower energy resonating mode having 825% higher sensitivity than conventional resonator structures. Moreover, the graded index structures show a 45% higher field confinement than the conventional PhCR structure.

13.
Sci Rep ; 13(1): 19415, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37940639

RESUMO

In this manuscript, a heterostructure-based topological nanophotonic structure is proposed for improved sensing performance. The topological effect is realized by connecting two dissimilar one-dimensional photonic crystal structures having overlapped photonic bandgaps. The structural parameters are optimized to regulate and alter the dispersion characteristics, which results in the opposite Zak phases. This demonstrates a robust topologsical interface state excitation at a 1737 nm operating wavelength. Further, a topological cavity structure having resonance mode at 1659 nm is formed by replacing the interface layers with a defect layer. The mode excitation is confirmed by analyzing the electric field confinement at the interface. The sensing capability of the structure is analytically evaluated by infiltrating different analytes within the cavity. The analytical results demonstrate the device's average sensitivity of around 774 nm/Refractive index unit (RIU) along with an average high Q-factor and figure of merit of around 5.2 × 104 and 2.6234 × 104 RIU-1, respectively. Because of the higher interface mode field confinement, the proposed structure exhibits a 92% higher sensitivity, 98% improved Quality factor, 206% improvement in figure of merit, and 86% higher interface field confinement than conventional Fabry-Perot resonator structures. Thus, the proposed topological cavity structure shows its broad sensing ability (Refractive Index: 1.3-1.6) along with a low-cost, simple fabrication and characterization process, promoting the development of highly sensitive planner nanophotonic devices.

14.
Sci Rep ; 13(1): 9292, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37286761

RESUMO

This manuscript presents a dielectric resonator structure with altered dispersion characteristics to enhance the photonic spin Hall effect (PSHE). The structural parameters are optimized to enhance the PSHE at 632.8 nm operating wavelength. The thickness-dependent angular dispersion analysis is carried out to optimize the structure and obtain the exceptional points. The PSHE-induced spin splitting shows a high sensitivity to the optical thickness of the defect layer. This gives a maximum PSHE-based transverse displacement (PSHE-TD) of around 56.66 times the operating wavelength at an incidence angle of 61.68°. Moreover, the structure's capability as a PSHE-based refractive index sensor is also evaluated. The analytical results demonstrate an average sensitivity of around 33,720 µm/RIU. The structure exhibits around five times higher PSHE-TD and approximately 150% improvement in sensitivity than the recently reported values in lossy mode resonance structures. Due to the purely dielectric material-assisted PhC resonator configurations and significantly higher PSHE-TD, the development of low-cost PSHE-based devices for commercial applications is envisaged.

15.
Stoch Environ Res Risk Assess ; : 1-15, 2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37362847

RESUMO

The time required to identify and confirm risk factors for new diseases and to design an appropriate treatment strategy is one of the most significant obstacles medical professionals face. Traditionally, this approach entails several clinical studies that may last several years, during which time strict preventative measures must be in place to contain the epidemic and limit the number of fatalities. Analytical tools may be used to direct and accelerate this process. This study introduces a six-state compartmental model to explain and assess the impact of age demographics by designing a dynamic, explainable analytics model of the SARS-CoV-2 coronavirus. An age-stratified mathematical model taking the form of a deterministic system of ordinary differential equations divides the population into different age groups to better understand and assess the impact of age on mortality. It also provides a more accurate and effective interpretation of the disease evolution, specifically in terms of the cumulative numbers of infected cases and deaths. The proposed Kermack-Mckendrick model is incorporated into a non-linear least-squares optimization curve-fitting problem whose optimized parameters are numerically obtained using the Levenberg-Marquard algorithm. The curve-fitting model's efficiency is proved by testing the age-stratified model's performance on three U.S. states: Connecticut, North Dakota, and South Dakota. Our results confirm that splitting the population into different age groups leads to better fitting and forecasting results overall as compared to those achieved by the traditional method, i.e., without age groups. By using comprehensive models that account for age, gender, and ethnicity, regional public health authorities may be able to avoid future epidemics from inflicting more fatalities and establish a public health policy that reduces the burden on the elderly population.

16.
RSC Adv ; 13(30): 20958-20965, 2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37448643

RESUMO

Numerous applications of chiro-optical effects can be found in nanophotonics, including imaging and spin-selective absorption, particularly in sensing for separating and detecting chiral enantiomers. Flat single-layer metasurfaces composed of chiral or achiral sub-wavelength structures offer unique properties to manipulate the light due to their extraordinary light-matter interaction. However, at optical wavelengths, the generation of strong chirality is found to be challenging via conventional chiral metasurface approaches. This work intends to design and optimize a dielectric chiral meta-nano-surface based on a diatomic design strategy to comprehend giant chiro-optical effects in the near-infrared (NIR) regime for potential application in circular dichroism (CD) spectroscopy. Instead of using a single chiral structure that limits the CD value at optical wavelengths, the proposed metasurface used a diatomic (two meta-atoms with distinct geometric parameters) chiral structure as a building block to significantly enhance the chiro-optical effect. Combining both meta-atoms in a single periodicity of the building block introduces constructive and destructive interferences to attain the maximum circular dichroism value exceeding 75%. Moreover, using multipolar resonance theory, the physics behind the generation of giant chiro-optical effects have also been investigated. The proposed dielectric chiral meta-platform based on the extra degree of freedom can find application in compact integrated optical setups for CD spectroscopy, enantiomer separation and detection, spin-dependent color filters, and beam splitters.

17.
Heliyon ; 9(9): e19447, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37681176

RESUMO

Wireless devices have become extremely inexpensive and popular in recent years. The two most significant advantages of wireless devices over wired ones are convenience and flexibility. Considering this, a wireless mouse pad prototype for access has been developed in this study. A capacitive sensors-based mouse pad with basic operations and conventional features has been developed using sensing arrays on paper. A facile, do-it-yourself fabrication process was utilized to develop a cost-effective, thin, wearable, and cleanroom-free wireless mouse cursor control (MCC) pad. The ablation process was used to cut the traces of conductive tape and paste them onto the paper to develop the MCC pad. The pad was connected with Espressif Systems (ESP)32 to wirelessly control the cursor of mobile and laptop. The capacitive touch sensor array-based pad is easy to reproduce and recycle. This pad can contribute to future advancements in thin human-machine interfaces, soft robotics, and medical and healthcare applications.

18.
Nanomaterials (Basel) ; 13(4)2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36839148

RESUMO

Two-dimensional materials (2DMs) have been vastly studied for various electrochemical sensors. Among these, the sensors that are directly related to human life and health are extremely important. Owing to their exclusive properties, 2DMs are vastly studied for electrochemical sensing. Here we have provided a selective overview of 2DMs-based electrochemical sensors that directly affect human life and health. We have explored graphene and its derivatives, transition metal dichalcogenide and MXenes-based electrochemical sensors for applications such as glucose detection in human blood, detection of nitrates and nitrites, and sensing of pesticides. We believe that the areas discussed here are extremely important and we have summarized the prominent reports on these significant areas together. We believe that our work will be able to provide guidelines for the evolution of electrochemical sensors in the future.

19.
Heliyon ; 9(2): e13586, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36846675

RESUMO

Nowadays, security is one of the living essentials, and there is a dire need for reliable, secure, and smarter locking systems. The stand-alone smart security systems are of great interest as they do not involve keys, cards, or unsecured communication in order to prevent carrying, loss, duplication, and hacking. Here, we report an invisible touch sensors-based smart door locking system (DLS). The passive transducer-based touch sensors are fabricated through a facile do-it-yourself (DIY) based fabrication process by pasting the hybrid geometry copper electrodes on cellulose paper. The employment of biodegradable, and non-toxic materials like paper and copper tape makes this configuration a good candidate for green electronics. For additional security, the keypad in the DLS is made invisible by covering it with paper and spray paint. One can only open the door by knowing the password as well as the location of each key on the sensor keypad. The system can efficiently recognize the exact pattern of passwords without any false values. Invisible touch sensors-based locking systems can easily contribute to the security applications in homes, banks, automobiles, apartments, lockers, and cabinets.

20.
ACS Omega ; 8(19): 16842-16850, 2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37214719

RESUMO

An eco-friendly, biodegradable, flexible, and facile fabricated interdigital electrode-based capacitive humidity sensor with applications in health and medicine has been reported here. Several sensors use copper tape as electrodes on the polyethylene terephthalate (PET) substrate, with non-woven paper as the sensing layer. Two different configurations of sensors were tested, i.e., with and without pores in the PET substrate. The sensing performance of both sensors has been tested for relative humidity ranging from 35 to 100% at temperatures ranging from 20 to 50 °C. The capacitance of the sensor varies linearly in response to the change in humidity. The sensor with pores shows a response from 28 to 630 pF as the humidity varied from 35 to 100%, whereas the sensor without pores responded from 22 to 430 pF. The response and recovery times of the fabricated sensor are observed as ∼2.4, and ∼1.8 s, respectively, and the sensitivity is 9.67 pF/% RH. The sensors are tested multiple times, and repeatable results are achieved each time with an accuracy of ±0.22%. Further, the sensor's response is also stable for different ranges of temperatures. Finally, to demonstrate an application of the proposed sensor, it has been utilized to monitor respiration through nose and mouth breathing. The low-cost, stable, repeatable, and highly sensitive response makes our fabricated sensor a promising candidate for practical field applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA