Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Eur J Appl Physiol ; 107(2): 135-44, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19533166

RESUMO

Bioelectrical impedance analysis (BIA) is an affordable, non-invasive, easy-to-operate, and fast alternative method to assess body composition. However, BIA tends to overestimate the percent body fat (%BF) in lean elderly and underestimate %BF in obese elderly people. This study examined whether proximal electrode placement eliminates this problem. Forty-two elderly men and women (64-96 years) who had a wide range of BMI [22.4 +/- 3.3 kg/m(2) (mean +/- SD), range 16.8-33.9 kg/m(2)] and %BF (11.3-44.8%) participated in this study. Using (2)H and (18)O dilutions as the criterion for measuring total body water (TBW), we compared various BIA electrode placements; wrist-to-ankle, arm-to-arm, leg-to-leg, elbow-to-knee, five- and nine-segment models, and the combination of distal (wrists or ankles) and proximal (elbows or knees) electrodes. TBW was most strongly correlated with the square height divided by the impedance between the knees and elbows (H(2)/Z (proximal); r = 0.965, P < 0.001). In the wrist-to-ankle, arm-to-arm, leg-to-leg, and five-segment models, we observed systematic errors associated with %BF (P < 0.05). After including the impedance ratio of the proximal to distal segments (P/D) as an independent variable, none of the BIA methods examined showed any systematic bias against %BF. In addition, all methods were able to estimate TBW more accurately (e.g., in the wrist-to-ankle model, from R(2) = 0.90, SEE = 1.69 kg to R(2) = 0.94, SEE = 1.30 kg). The results suggest that BIA using distal electrodes alone tends to overestimate TBW in obese and underestimate TBW in lean subjects, while proximal electrodes improve the accuracy of body composition measurements.


Assuntos
Idoso , Composição Corporal/fisiologia , Distribuição da Gordura Corporal/métodos , Obesidade/diagnóstico , Magreza/diagnóstico , Idoso/fisiologia , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Água Corporal/fisiologia , Impedância Elétrica , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Obesidade/fisiopatologia , Análise de Regressão , Magreza/fisiopatologia
2.
J Appl Physiol (1985) ; 103(5): 1688-95, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17761792

RESUMO

This study aimed to test the hypothesis that a segmental bioelectrical impedance (BI) analysis can predict whole body skeletal muscle (SM) volume more accurately than a whole body BI analysis. Thirty males (19-34 yr) participated in this study. They were divided into validation (n = 20) and cross-validation groups (n = 10). The BI values were obtained using two methods: whole body BI analysis, which determines impedance between the wrist and ankle; and segmental BI analysis, which determines the impedance of every body segment in both sides of the upper arm, lower arm, upper leg and lower leg, and five parts of the trunk. Using a magnetic resonance imaging method, whole body SM volume was determined as a reference (SMV(MRI)). Simple and multiple regression analyses were applied to (length)(2)/Z (BI index) for the whole body and for every body segment, respectively, to develop the prediction equations of SMV(MRI). In the validation group, there were no significant differences between the measured and estimated SMV and no systematic errors in either BI analysis. In the cross-validation group, the whole body BI analysis produced systematic errors and resulted in the overestimation of SMV(MRI), but the segmental BI analysis was cross-validated. In the pooled data, the segmental BI analysis produced a prediction equation, which involves the BI indexes of the trunk and upper thigh as independent variables, with a SE of estimation of 1,693.8 cm(3) (6.1%). Thus the findings obtained here indicated that the segmental BI analysis is superior to the whole body BI analysis for estimating SMV(MRI).


Assuntos
Antropometria/métodos , Composição Corporal , Impedância Elétrica , Imageamento por Ressonância Magnética , Músculo Esquelético/anatomia & histologia , Adulto , Humanos , Masculino , Modelos Biológicos , Tamanho do Órgão , Reprodutibilidade dos Testes
3.
Appl Physiol Nutr Metab ; 42(2): 157-165, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28112969

RESUMO

This study examined the validity of segmental bioelectrical impedance (BI) analysis for predicting the fat-free masses (FFMs) of whole-body and body segments in children including overweight individuals. The FFM and impedance (Z) values of arms, trunk, legs, and whole body were determined using a dual-energy X-ray absorptiometry and segmental BI analyses, respectively, in 149 boys and girls aged 6 to 12 years, who were divided into model-development (n = 74), cross-validation (n = 35), and overweight (n = 40) groups. Simple regression analysis was applied to (length)2/Z (BI index) for each of the whole-body and 3 segments to develop the prediction equations of the measured FFM of the related body part. In the model-development group, the BI index of each of the 3 segments and whole body was significantly correlated to the measured FFM (R2 = 0.867-0.932, standard error of estimation = 0.18-1.44 kg (5.9%-8.7%)). There was no significant difference between the measured and predicted FFM values without systematic error. The application of each equation derived in the model-development group to the cross-validation and overweight groups did not produce significant differences between the measured and predicted FFM values and systematic errors, with an exception that the arm FFM in the overweight group was overestimated. Segmental bioelectrical impedance analysis is useful for predicting the FFM of each of whole-body and body segments in children including overweight individuals, although the application for estimating arm FFM in overweight individuals requires a certain modification.


Assuntos
Desenvolvimento Infantil , Modelos Biológicos , Desenvolvimento Muscular , Avaliação Nutricional , Sobrepeso/patologia , Absorciometria de Fóton , Algoritmos , Composição Corporal , Índice de Massa Corporal , Criança , Impedância Elétrica , Feminino , Humanos , Japão , Masculino , Sobrepeso/diagnóstico por imagem , Sobrepeso/etnologia , Análise de Regressão , Reprodutibilidade dos Testes , Instituições Acadêmicas
4.
J Appl Physiol (1985) ; 100(2): 572-8, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16210443

RESUMO

This study aimed to investigate the validity of using segmental bioelectrical impedance (BI) analysis for estimating skeletal muscle volume (MV) in the trunk, defined as the body segment from the acromion process to the greater trochanter. Using a magnetic resonance imaging (MRI) method, the trunk MV was determined in 28 men (19 approximately 34 yr), divided into validation (n = 20) and cross-validation (n = 8) groups, and used as a reference (MV(MRI)). For BI measurements of the trunk, the source electrodes were placed at the dorsal surface of the third metacarpal bone of both hands and the dorsal surface of the third metatarsal bone of both feet, and the detector electrodes were placed at the acromion process of both shoulders and the greater trochanter of both femurs. Using this arrangement, the BI values of five parts of the trunk, both sides of the upper region, the middle region, and both sides of the lower region, were obtained and then used to calculate the whole trunk BI value and BI index (BI index(TR)). In the validation group, a simple regression analysis of the relationship between BI index(TR) and MV(MRI) showed a significant correlation between the two variables (r = 0.884, P < 0.05) and produced a prediction equation with a SE of estimation of 1,020.3 cm3 (8.5%). In the validation and cross-validation groups, there were no significant differences between the measured and estimated MV without systematic errors. These findings indicate that the segmental BI analysis employed in the present study can be used to estimate trunk MV.


Assuntos
Músculo Esquelético/anatomia & histologia , Acrômio , Adulto , Composição Corporal , Impedância Elétrica , Fêmur , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Análise de Regressão , Reprodutibilidade dos Testes
5.
Open Access J Sports Med ; 4: 97-108, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24379714

RESUMO

The aim of this study was to evaluate and quantify differences in muscle distribution in athletes of various ball sports using segmental bioelectrical impedance analysis (SBIA). Participants were 115 male collegiate athletes from four ball sports (baseball, soccer, tennis, and lacrosse). Percent body fat (%BF) and lean body mass were measured, and SBIA was used to measure segmental muscle volume (MV) in bilateral upper arms, forearms, thighs, and lower legs. We calculated the MV ratios of dominant to nondominant, proximal to distal, and upper to lower limbs. The measurements consisted of a total of 31 variables. Cluster and factor analyses were applied to identify redundant variables. The muscle distribution was significantly different among groups, but the %BF was not. The classification procedures of the discriminant analysis could correctly distinguish 84.3% of the athletes. These results suggest that collegiate ball game athletes have adapted their physique to their sport movements very well, and the SBIA, which is an affordable, noninvasive, easy-to-operate, and fast alternative method in the field, can distinguish ball game athletes according to their specific muscle distribution within a 5-minute measurement. The SBIA could be a useful, affordable, and fast tool for identifying talents for specific sports.

6.
Eur J Appl Physiol ; 94(1-2): 25-35, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15605280

RESUMO

This study tested the hypothesis that, as compared to whole-body bioelectrical impedance (BI) analysis, segmental BI analysis can estimate lean body mass (LBM) more accurately in a population with a large difference in muscularity. In addition to whole-body BI, which determines impedance (Z) between the wrist and ankle, two segmental BI analyses which determine the Z value of every body segment in each of (1) the arms, legs and trunk (distal BI) and (2) the upper arms, upper legs and trunk (proximal BI) were applied to a group of 125 male athletes and 75 non-athletes. The subjects were divided into validation and cross-validation groups. Simple and multiple regression analyses were applied to (length)(2)/Z (BI index) values for the whole-body and each body segment, to develop the prediction equations of LBM measured using air-displacement plethysmography. In the validation group, the SE of estimation was similar in the whole-body (3.4 kg, 5.4%), distal (3.4 kg, 5.5%) and proximal BI (3.3 kg, 5.2%) analyses. However, the whole-body and distal BI analyses produced systematical errors in the estimates of LBM. Moreover, the residuals in the two methods significantly (P < 0.05) correlated with the ratios of BI indices of the upper arms and upper legs to those of the arms and legs, respectively, calculated as variables approximating the relative development of lean tissues at the proximal area of limbs. On the other hand, the proximal BI analysis was validated and cross-validated. Thus, the accuracy of estimating LBM was similar in the whole-body and the two segmental BI analyses. However, the prediction equations derived from the use of the whole-body BI index and a combination of the arms, legs and trunk BI indices produced a systematical error relating to the difference between the limb segments in lean tissue development.


Assuntos
Algoritmos , Antropometria/métodos , Constituição Corporal/fisiologia , Índice de Massa Corporal , Impedância Elétrica , Modelos Biológicos , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/fisiologia , Pletismografia Total/métodos , Adulto , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Magreza/fisiopatologia
7.
J Gravit Physiol ; 11(2): P243-4, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16240530

RESUMO

We have reported that centrifuge-induced artificial gravity with ergometric exercise could reduce developing cardiovascular deconditioning in humans. In the present study, we examined this load could prevent the myatrophy and osteoporosis induced by head-down bedrest for 20 days. Subjects were ten healthy male volunteers with informed consent. They were requested to lie down at -6 degrees for 20 days, and evaluation for cardiovascular deconditioning, myatrophy, and osteoporosis. As the result, high G-load with low intensity exercise suppressed the orthostatic intolerance and increase in serum osteoporotic marker, whereas low G-load with high intensity ergometric exercise maintained the maximal oxygen intake, heart dimension, and prevented myatrophy. The combination of high/low G-load with low/high intensity exercise will determine the optimal protocol for prevention of cardiovascular deconditioning, myatrophy, and osteoporosis.


Assuntos
Repouso em Cama/efeitos adversos , Descondicionamento Cardiovascular/fisiologia , Exercício Físico/fisiologia , Gravidade Alterada , Hipergravidade , Contramedidas de Ausência de Peso , Adulto , Aminoácidos/urina , Biomarcadores , Desmineralização Patológica Óssea/prevenção & controle , Centrifugação , Ecocardiografia , Deslocamentos de Líquidos Corporais/fisiologia , Decúbito Inclinado com Rebaixamento da Cabeça , Frequência Cardíaca , Humanos , Hipotensão Ortostática/prevenção & controle , Perna (Membro) , Masculino , Músculo Esquelético/fisiologia , Atrofia Muscular/prevenção & controle , Consumo de Oxigênio , Volume Plasmático/fisiologia , Sistema Nervoso Simpático/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA