Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Cancers (Basel) ; 14(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35454953

RESUMO

To assess the perioperative and short-term functional outcomes of robot-assisted partial nephrectomy (RAPN) with intraoperative navigation using an ultra-high-resolution computed tomography (UHR-CT) scanner, we retrospectively analyzed 323 patients who underwent RAPN using an UHR-CT or area-detector CT (ADCT). Perioperative outcomes and the postoperative preservation ratio of estimated glomerular filtration rate (eGFR) were compared. After the propensity score matching, we evaluated 99 patients in each group. Although the median warm ischemia time (WIT) was less than 25 min in both groups, it was significantly shorter in the UHR-CT group than in the ADCT group (15 min vs. 17 min, p = 0.032). Moreover, the estimated blood loss (EBL) was significantly lower in the UHR-CT group than in the ADCT group (33 mL vs. 50 mL, p = 0.028). However, there were no significant intergroup differences in the postoperative preservation ratio of eGFR at 3 or 6 months of follow-up (ADCT 91.8% vs. UHR-CT 93.5%, p = 0.195; and ADCT 91.7% vs. UHR-CT 94.0%, p = 0.160, respectively). Although no differences in short-term renal function were observed in intraoperative navigation for RAPN in this propensity score-matched cohort, this study is the first to demonstrate that UHR-CT resulted in a shorter WIT and lower EBL than ADCT.

2.
Phys Eng Sci Med ; 44(2): 365-375, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33620700

RESUMO

The aim of this study was to investigate the relationship of quantitative parameters between the two-dimensional region of interest (ROI) and the three-dimensional volume of interest (VOI) for accumulation of radiopharmaceutical. Single-photon emission computed tomography combined with computed tomography (SPECT/CT) images of the NEMA/IEC phantom were acquired. The ROIs and VOIs were automatically set to the sphere and background in the phantom. We defined as two-dimensional analysis (2D analysis) that which used ROIs set on the center section of the sphere, and as three-dimensional analysis (3D analysis) that which used VOIs set on the center of gravity of the sphere. Dose linearity (DL), the recovery coefficient (RC), the contrast-to-noise ratio (CNR), and standardized uptake value (SUV) were evaluated. Each index value was compared between both analyses. DL was almost 1 under both conditions. RC showed a similar tendency with 2D and 3D analyses. The CNR for 3D analysis was smaller than for 2D analysis. The maximum SUV was almost equal with both analyses. The mean SUV with 3D analysis was underestimated by 4.83% on average compared with 2D analysis. For the same accumulation, a difference may occur in the quantitative index between 2 and 3D analyses. In particular, the quantitative parameters based on the average value tends to be smaller with 3D analysis than 2D analysis. The quantitative parameters in 2D analysis showed dependence upon the cross section used for setting the ROI, whereas 3D analysis showed less dependence on the position of the VOI.


Assuntos
Compostos Radiofarmacêuticos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Imagens de Fantasmas
3.
Nucl Med Commun ; 42(8): 877-883, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33741850

RESUMO

OBJECTIVE: This study proposes an automated classification of benign and malignant in highly integrated regions in bone single-photon emission computed tomography/computed tomography (SPECT/CT) using a three-dimensional deep convolutional neural network (3D-DCNN). METHODS: We examined 100 regions of 35 patients with bone SPECT/CT classified as benign and malignant by other examinations and follow-ups. First, SPECT and CT images were extracted at the same coordinates in a cube, with a long side two times the diameter of a high concentration in SPECT images. Next, we inputted the extracted image to DCNN and obtained the probability of benignity and malignancy. Integrating the output from DCNN of each SPECT and CT image provided the overall result. To validate the efficacy of the proposed method, the malignancy of all images was assessed using the leave-one-out cross-validation method; besides, the overall classification accuracy was evaluated. Furthermore, we compared the analysis results of SPECT/CT, SPECT alone, CT alone, and whole-body planar scintigraphy in the highly integrated region of the same site. RESULTS: The extracted volume of interest was 50 benign and malignant regions, respectively. The overall classification accuracy of SPECT alone and CT alone was 73% and 68%, respectively, while that of the whole-body planar analysis at the same site was 74%. When SPECT/CT images were used, the overall classification accuracy was the highest (80%), while the classification accuracy of malignant and benign was 82 and 78%, respectively. CONCLUSIONS: This study suggests that DCNN could be used for the direct classification of benign and malignant regions without extracting the features of SPECT/CT accumulation patterns.


Assuntos
Redes Neurais de Computação , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Osso e Ossos , Humanos , Pessoa de Meia-Idade
4.
Jpn J Radiol ; 39(2): 186-197, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33037956

RESUMO

PURPOSE: To determine the image quality improvement including vascular structures using deep learning reconstruction (DLR) for ultra-high-resolution CT (UHR-CT) and area-detector CT (ADCT) compared to a commercially available hybrid-iterative reconstruction (IR) method. MATERIALS AND METHOD: Thirty-two patients suspected of renal cell carcinoma underwent dynamic contrast-enhanced (CE) CT using UHR-CT or ADCT systems. CT value and contrast-to-noise ratio (CNR) on each CT dataset were assessed with region of interest (ROI) measurements. For qualitative assessment of improvement for vascular structure visualization, each artery was assessed using a 5-point scale. To determine the utility of DLR, CT values and CNRs were compared among all UHR-CT data by means of ANOVA followed by Bonferroni post hoc test, and same values on ADCT data were also compared between hybrid IR and DLR methods by paired t test. RESULTS: For all arteries except the aorta, the CT value and CNR of the DLR method were significantly higher compared to those of the hybrid-type IR method in both CT systems reconstructed as 512 or 1024 matrixes (p < 0.05). CONCLUSION: DLR has a higher potential to improve the image quality resulting in a more accurate evaluation for vascular structures than hybrid IR for both UHR-CT and ADCT.


Assuntos
Abdome/diagnóstico por imagem , Carcinoma de Células Renais/diagnóstico por imagem , Aprendizado Profundo , Neoplasias Renais/diagnóstico por imagem , Rim/diagnóstico por imagem , Melhoria de Qualidade , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artérias/diagnóstico por imagem , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador
5.
J Endourol ; 35(7): 1006-1012, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33267680

RESUMO

Objectives: To evaluate the outcomes of robot-assisted partial nephrectomy (RAPN) in cystic renal tumors. Materials and Methods: We retrospectively analyzed patients who underwent RAPN for either cystic (n = 46) or solid (n = 271) renal tumors at Fujita Health University between 2010 and 2019. Cystic renal tumors were diagnosed using cross-sectional imaging. Perioperative, oncologic, and functional outcomes were assessed. Results: The median follow-up periods were 38, 41, and 37 months in the total, cystic, and solid groups, respectively. Most patient characteristics were similar among both groups, while the median age of the cystic group was significantly lower than that of the solid group (p = 0.02). Most perioperative variables and complications were comparable between the two groups. There was no significant difference between the groups in perioperative renal function. The estimated glomerular filtration rate preservation rates were 93.1% and 89.2% in the cystic and solid groups, respectively (p = 0.17). The cystic group showed a higher benign histology rate (19.6% vs 7%) and lower Fuhrman grade than the solid group (24.3% vs 15.1% in grade 1, and 73% vs 81.3% in grade 2), although there was no statistically significant difference between the two groups. In the solid group, 10 patients (3.7%) experienced recurrence, and 2 patients (0.7%) died of renal-cell carcinoma, while none of the patients with cystic tumors experienced recurrence. There was no statistically significant difference between the cystic and solid tumors with respect to 5-year recurrence-free survival (p = 0.18), cancer-specific survival (p = 0.55), and overall survival (p = 0.35). Conclusions: RAPN for cystic renal tumors appears to be safe and feasible with perioperative, long-term functional and oncologic outcomes comparable with those in solid tumors. RAPN can be a safe and effective surgical option for cystic renal tumors.


Assuntos
Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Rim/fisiologia , Neoplasias Renais/cirurgia , Recidiva Local de Neoplasia , Nefrectomia , Estudos Retrospectivos , Resultado do Tratamento
6.
Fujita Med J ; 6(3): 73-80, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-35111525

RESUMO

OBJECTIVES: Renal scintigraphy is widely used to evaluate residual function of a transplanted kidney from the donor. Dynamic computed tomography (CT) imaging can evaluate both kidney morphology and regional renal function. The aim of this study was to develop an imaging protocol and a calculation method using dynamic CT for assessing the effective renal plasma flow (ERPF) by model analysis, and to evaluate the validity of the obtained ERPF values. METHODS: Preoperative dynamic CT examination with a low radiation dose exposure system was performed for 25 renal transplant donors, and ERPF was calculated from the obtained images (CT-ERPF). To calculate CT-ERPF, we set the region of interest (ROI) in the renal cortex using automatic ROI-setting software developed in our laboratory. We compared the processing time with automatic and manual ROI settings. To evaluate the validity of CT-ERPF, we examined the correlation of age with CT-ERPF and compared with reported ERPF values. We also compared the uptake rates of technetium-99m-dimercaptosuccinic acid and CT-ERPF in terms of the right-to-left ratio. RESULTS: There was good agreement of CT-ERPF assessed using automatic and manual ROIs. CT-ERPF was negatively correlated with age and showed values below the reference ERPF range in 21 cases. The right-to-left ratio of CT-ERPF showed a significant correlation with that of technetium-99m-dimercaptosuccinic acid. CONCLUSIONS: Using our method, CT-ERPF was a useful indicator for preoperative evaluation of donor's renal function.

7.
Medicine (Baltimore) ; 97(9): e9906, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29489691

RESUMO

Noncontrast computed tomography (NCCT) has been used for the detection of early ischemic change (EIC); however, correct interpretation of NCCT findings requires much clinical experience. This study aimed to assess the accuracy of time maximum intensity projection computed tomography technique (tMIP), which reflects the maximum value for the time phase direction from the dynamic volume data for each projected plane, for detection of EIC, against that of NCCT.Retrospective review of NCCT, cerebral blood volume in CT perfusion (CTP-CBV), and tMIP of 186 lesions from 280 regions evaluated by Alberta Stroke Program Early CT Score (ASPECTS) in 14 patients with acute middle cerebral artery stroke who had undergone whole-brain CTP using 320-row area detector CT was performed. Four radiologists reviewed EIC on NCCT, CTP-CBV, and tMIP in each ASPECTS region at onset using the continuous certainty factor method. Receiver operating characteristic analysis was performed to compare the relative performance for detection of EIC. The correlations were evaluated.tMIP-color showed the best discriminative value for detection of EIC. There were significant differences in the area under the curve for NCCT and tMIP-color, CTP-CBV (P < .05). Scatter plots of ASPECTS showed a positive significant correlation between NCCT, tMIP-gray, tMIP-color, and the follow-up study (NCCT, r = 0.32, P = .0166; tMIP-gray, r = 0.44, P = .0007; tMIP-color, r = 0.34, P = .0104).Because tMIP provides a high contrast parenchymal image with anatomical and vascular information in 1 sequential scan, it showed greater accuracy for detection of EIC and predicted the final infarct extent more accurately than NCCT based on ASPECTS.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Feminino , Seguimentos , Humanos , Masculino , Curva ROC , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA