Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Phys Med ; 59: 151-157, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30852055

RESUMO

The multichannel vaginal cylinder (MVC) applicator employed for gynecological high dose rate (HDR) brachytherapy increases dose delivery complexity, and thus makes the treatment more prone to errors. A quality assurance (QA) procedure tracking the source throughout dose delivery can detect dwell position and time errors in the multiple channels of the applicator. A new MVC system with integrated real time in vivo treatment delivery QA has been developed based on diodes embedded on the outer surface of the MVC. It has been pre-calibrated and verified using a non-clinical treatment plan with consecutive test positions and dwell times within each catheter, followed by the delivery of ten clinical plans of adjuvant vaginal cuff brachytherapy following hysterectomy for endometrial cancer. The non-clinical verification showed overall mean dwell position and time discrepancies between the nominal and measured treatment of -0.2 ±â€¯0.5 mm and -0.1 ±â€¯0.1 s (k = 1), respectively. The clinical plans showed mean positional discrepancies of 0.2 ±â€¯0.4 and 0.0 ±â€¯0.8 mm, for the central and peripheral catheters, respectively, and mean dwell time discrepancies of -0.1 ±â€¯0.2 and -0.0 ±â€¯0.1 s for central and peripheral catheters, respectively. The innovative prototype of the MVC system has shown the ability to track the source with sub-mm and sub-second accuracy, and demonstrated potential for its incorporation into the clinical routine.


Assuntos
Braquiterapia/instrumentação , Neoplasias dos Genitais Femininos/radioterapia , Calibragem , Desenho de Equipamento , Feminino , Humanos , Controle de Qualidade , Planejamento da Radioterapia Assistida por Computador , Fatores de Tempo
2.
Phys Med ; 44: 58-65, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29254592

RESUMO

PURPOSE: A direct planning approach with multi-channel vaginal cylinders (MVCs) used for HDR brachytherapy of vaginal cancers is particularly challenging. Purpose of this study was to compare the dosimetric performances of different forward and inverse methods used for the optimization of MVC-based vaginal treatments for endometrial cancer, with a particular attention to the definition of strategies useful to limit the high doses to the vaginal mucosa. METHODS: Twelve postoperative vaginal HDR brachytherapy treatments performed with MVCs were considered. Plans were retrospectively optimized with three different methods: Dose Point Optimization followed by Graphical Optimization (DPO + GrO), Inverse Planning Simulated Annealing with two different class solutions as starting conditions (surflPSA and homogIPSA) and Hybrid Inverse Planning Optimization (HIPO). Several dosimetric parameters related to target coverage, hot spot extensions and sparing of organs at risk were analyzed to evaluate the quality of the achieved treatment plans. Dose homogeneity index (DHI), conformal index (COIN) and a further parameter quantifying the proportion of the central catheter loading with respect to the overall loading (i.e., the central catheter loading index: CCLI) were also quantified. RESULTS: The achieved PTV coverage parameters were highly correlated with each other but uncorrelated with the hot spot quantifiers. HomogIPSA and HIPO achieved higher DHIs and CCLIs and lower volumes of high doses than DPO + GrO and surflPSA. CONCLUSIONS: Within the investigated optimization methods, HIPO and homoglPSA showed the highest dose homogeneity to the target. In particular, homogIPSA resulted also the most effective in reducing hot spots to the vaginal mucosa.


Assuntos
Braquiterapia , Mucosa/efeitos da radiação , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Vagina/efeitos da radiação , Neoplasias do Endométrio/radioterapia , Feminino , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA