Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
J Craniofac Surg ; 31(6): e597-e599, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32649535

RESUMO

Schwannoma is a rare benign tumor, originating from Schwann cells of the peripheral nerve sheath. We describe a case of intraconal orbital schwannoma, causing compression to the optic nerve and progressive visual impairment treated with surgical resection. The diagnosis of benign orbital schwannoma was provided by histopathological examination (large spindle cell tumor with AntoniB-type cell pattern) and also with immunohistochemistry (positivity for S-100 protein). The 6 months' follow-up was performed. The patient was asymptomatic during the 6-month follow-up.


Assuntos
Neurilemoma/cirurgia , Neoplasias Orbitárias/cirurgia , Transtornos da Visão/etiologia , Adulto , Humanos , Imuno-Histoquímica , Masculino , Neurilemoma/complicações , Nervo Óptico/patologia , Neoplasias Orbitárias/complicações , Proteínas S100/metabolismo
2.
G Ital Med Lav Ergon ; 42(4): 231-237, 2020 12.
Artigo em Italiano | MEDLINE | ID: mdl-33600644

RESUMO

SUMMARY: The study aimed to evaluate, through the use of the EA-RfitTM Validation System, the real reduction (PAR) for the right ear (AuD), for the left ear (AuS) and biaural reduction related to each of the seven earplugs currently produced by 3M. In addition, we wanted to verify any difference between the aforementioned PARs in consideration of the tendency to predominantly use the right hand (right-handed) or the left hand (left-handed) and in relation to gender. Finally, for each insert and for each subject, an audiometric examination was conducted with the insert worn, to compare the average PAR value obtained by the EA-RfitTM system for each of the seven inserts and for all selected subjects, with the determined abatement curve through the audiometric measurement of the hearing threshold with the insert worn. The use of the E-ARfitTM system for the choice of the ear insert leads to important advantages in the protection of all workers. Moldable acoustic PPE generally proved to be more efficient than non-moldable, so much so that the higher SNRs (provided by the manufacturer), especially when referring to non-moldable inserts, were found to be misleading as to the real personal abatement capacity of the inserts. The average audiometric curves, obtained with the different inserts worn, confirmed that all of them guarantee a higher reduction for high frequencies than for "social" ones.


Assuntos
Perda Auditiva Provocada por Ruído , Ruído Ocupacional , Dispositivos de Proteção das Orelhas , Desenho de Equipamento , Mãos , Humanos
3.
J Craniofac Surg ; 30(4): 1252-1254, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30908442

RESUMO

Corneal neurotization represents an effective surgical strategy to restore corneal sensibility in patients affected by neurotrophic keratopathy.Corneal sensibility is essential in preserving structure and function of the eye. Loss of corneal sensibility can lead to a degenerative condition of the cornea known as neurotrophic keratopathy.Moreover, patients suffering from facial palsy show failure of full eyelid closure resulting in chronic corneal exposure and subsequent progressive damage.Reports have shown that the use of the contralateral ophthalmic division of the trigeminal nerve can be effective in restoring corneal sensibility. In the present study the authors expose a new technique by means of which direct neurotization of the anesthetic cornea was achieved using the homolateral second division of the trigeminal nerve. Effectiveness of the technique was evaluated using in vivo confocal microscopy.To the best of authors' knowledge, this is the first report of this technique in literature.


Assuntos
Doenças da Córnea/cirurgia , Paralisia Facial/cirurgia , Transferência de Nervo/métodos , Nervo Trigêmeo/transplante , Córnea/cirurgia , Feminino , Humanos , Ceratite/cirurgia , Microscopia Confocal , Pessoa de Meia-Idade , Regeneração Nervosa/fisiologia , Sensação , Nervo Trigêmeo/fisiologia , Doenças do Nervo Trigêmeo/cirurgia
5.
Eye Contact Lens ; 44 Suppl 2: S48-S53, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28991055

RESUMO

PURPOSE: To assess keratoconus (KC) progression in patients with allergies who also tested positive to surface matrix metalloproteinase 9 (MMP-9) point-of-care test. METHODS: Prospective comparative study including 100 stage I-II keratoconic patients, mean age 16.7±4.6 years. All patients underwent an anamnestic questionnaire for concomitant allergic diseases and were screened with the MMP-9 point-of-care test. Patients were divided into two groups: patients KC with allergies (KC AL) and patients KC without allergies (KC NAL). Severity of allergy was established by papillary subtarsal response grade and KC progression assessed by Scheimpflug corneal tomography, corrected distance visual acuity (CDVA) measurement in a 12-month follow-up. RESULTS: The KC AL group included 52 patients and the KC NAL group 48. In the KC AL group, 42/52 of patients (81%) were positive to MMP-9 point-of-care test versus two positive patients in the KC NAL group (4%). The KC AL group data showed a statistically significant decrease of average CDVA, from 0.155±0.11 to 0.301±0.2 logarithm of the minimum angle of resolution (P<0.005) at 12 months; Kmax value increased significantly, from 50.2 D±2.7 to 55.2 D±1.9 on average. The KC NAL group revealed a slight KC progression without statistically significant changes. Pearson correlation test showed a high correlation between Kmax worsening and severity of PSR in the KC AL group. CONCLUSIONS: The study demonstrated a statistically significant progression of KC in patients with concomitant allergies, positive to MMP-9 point-of-care test versus negative. A high correlation between severity of allergy and KC progression was documented.


Assuntos
Hipersensibilidade/metabolismo , Ceratocone/metabolismo , Metaloproteinase 9 da Matriz/metabolismo , Sistemas Automatizados de Assistência Junto ao Leito , Adolescente , Adulto , Criança , Progressão da Doença , Feminino , Humanos , Masculino , Estudos Prospectivos , Adulto Jovem
6.
J Craniofac Surg ; 29(8): 2312-2315, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30320676

RESUMO

PURPOSE: To describe the use of a double suture and conjunctival cuts in the lateral tarsal strip (LTS) and to evaluate postsurgical outcome in patients with severe involutional ectropion. METHODS: A prospective randomized study was conducted on 16 eyelids of 8 patients with symptomatic severe involutional ectropion. The 8 patients were between 62 and 79 years. They were distributed into 2 groups consisting of 4 patients each. The control group was treated with a conventional lateral tarsal strip (C-LTS), the second group underwent a modified lateral tarsal strip (M-LTS). The mean follow-up was 18 months. Success was defined as relief in lid laxity. The recurrence rate was also evaluated. RESULTS: Patients treated with M-LTS showed lower horizontal laxity (3.5 ±â€Š0.2) than patients treated with C-LTS (5.7 ±â€Š0.2). During the 18-month follow-up, a statistically significant difference was found between the 2 groups with P value <0.05. CONCLUSIONS: The use of a double suture and conjunctival cuts in the lateral tarsal strip proposed by Meduri showed a reduction of postsurgical ectropion's grade and postsurgical recurrences. This technique could be used for the treatment of patients with a severe ectropion.


Assuntos
Blefaroplastia/métodos , Túnica Conjuntiva/cirurgia , Ectrópio/cirurgia , Técnicas de Sutura , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Suturas
7.
Med Lav ; 106(4): 284-93, 2015 Jul 08.
Artigo em Italiano | MEDLINE | ID: mdl-26154471

RESUMO

BACKGROUND: Laboratory levels of perceived noise attenuation as heard using earplugs are always higher than the real levels that can be achieved at the workplace. The employer is bound by law to supply individual hearing protection devices (HPDs), to assess their efficiency and efficacy, and also to inform and train workers on the correct use of HPDs. OBJECTIVES: This study assessed the real "personal attenuation rating" (PAR) of HPDs  used by workers at the workplace, before (PAR A) and after (PAR B) specific and individual training. These values were also compared with the theoretical  "single number rating" (SNR) provided by the manufacturer. METHODS: The study covered all the 65 male employees of an awnings factory, using the E-A-RfitTM computerized method, which can measure PARs, based on the difference between sound pressures recorded by an "outside" microphone and an "inside" microphone placed in the auditory canal, with earplugs inserted, before (PAR A) and after (PAR B), i.e., the specific and individual training described above. RESULTS/CONCLUSIONS: PARs B were always definitely higher than PARs A, both for all tested frequencies and the corresponding average values, which were automatically detected by E-A-RfitTM. Furthermore the same PARs B were  decidedly lower than the respective SNRs supplied by the manufacturer on the basis of laboratory assessments. These data prove that specific and individual training for workers improves the performance of earplugs, contributing to a more appropriate secondary prevention of the effects of noise on hearing; they also prove that the real attenuation recorded in workers are always lower than those supplied by the manufacturer of the devices. It is recommended that the E-A-RfitTM system, which allowed these results to be achieved objectively, should be normally used to assess exposure to noise in workers, when HPDs are worn.


Assuntos
Periféricos de Computador , Dispositivos de Proteção das Orelhas , Monitoramento Ambiental/instrumentação , Ruído Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Saúde Ocupacional/educação , Adulto , Indústria da Construção , Monitoramento Ambiental/métodos , Desenho de Equipamento , Falha de Equipamento , Perda Auditiva Provocada por Ruído/prevenção & controle , Humanos , Masculino , Microcomputadores , Ruído Ocupacional/efeitos adversos , Ruído Ocupacional/legislação & jurisprudência , Doenças Profissionais/prevenção & controle , Software , Local de Trabalho/normas
8.
Int Ophthalmol ; 34(3): 651-4, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23928943

RESUMO

We report the clinical and confocal microscopic findings of the cornea in a patient with smouldering multiple myeloma (SMM) using in vivo scanning laser confocal microscopy. A 72-year-old female underwent a complete ophthalmological examination including slit-lamp biomicroscopy with digital photography, HRT II laser scanning in vivo confocal microscopy and haematological laboratory assessment. Corneal biomicroscopy revealed the presence of bilateral diffuse microgranular tiny grey opacities. In vivo confocal microscopy showed randomly oriented hyper-reflective needle-shaped crystals throughout all levels of the stroma, sparing epithelium and endothelium. In vivo confocal microscopy was very helpful in the differential diagnosis by allowing the nature of the corneal deposits to be established, revealing the typical aspect of the crystals, and excluding granular dystrophy, leading to a suspected diagnosis of SMM. Crystalline corneal deposits may easily be confused as crumb-like opacities typical of granular dystrophy on slit-lamp examination even by experienced ophthalmologists.


Assuntos
Doenças da Córnea/patologia , Neoplasias Oculares/patologia , Mieloma Múltiplo/patologia , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Microscopia Confocal
9.
Cornea ; 43(3): 285-294, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37699556

RESUMO

PURPOSE: The aim of this study was to report the 12 to 96 months results of a tissue-preservation algorithm based on ray-tracing-guided transepithelial excimer laser central corneal ablation (RT t-PRK) combined with individualized pachymetry-guided accelerated crosslinking (M nomogram ACXL) in young adult patients with stable keratoconus (KC). METHODS: This was a prospective interventional study including 38 eyes of 38 young adult patients (stage II KC) with a mean age of 35 years (range 26-46 years) who underwent simultaneous RT with t-PRK plus pachymetry-based ACXL in the worst eye. The treatments were performed using the iViS Suite iRES Excimer Laser (Ligi, Taranto, Italy). Ray-tracing-guided treatments were planned using the customized interactive programmed transepithelial ablation (CIPTA) 2 web software and diagnostic data were assessed by the Precisio 2 tomographer (Ligi, Taranto, Italy) and Sirius tomographer (C.S.O., Florence, Italy). The main outcome measures included uncorrected distance visual acuity, best spectacle-corrected visual acuity, Kmax, high-order aberrations, minimum corneal thickness, and posterior elevation, with a mean follow-up of 52 months (range 12-96 m). RESULTS: The mean UDVA improved + 3.5 ±1.28 Snellen lines (SL); 38% gained ≥ 4 ±1.34 SLs, 35% ≥ 3 ±1.21 SLs, 22% ≥ 2 ±1.12 SLs, and 5% ≥ 1 ±0.75 SLs. The mean best spectacle-corrected visual acuity increased by + 4.3 ±1.3 SL. Sixty-eight percent gained ≥ 4 ±0.88 SLs and 30% ≥ 3 ±0.78 SL. No SLs were lost. CONCLUSIONS: RT t-PRK plus ACXL significantly improved the quality of vision in patients with KC, preventing overcorrection and minimizing tissue consumption.


Assuntos
Ceratocone , Ceratectomia Fotorrefrativa , Adulto Jovem , Humanos , Adulto , Pessoa de Meia-Idade , Ceratocone/tratamento farmacológico , Ceratocone/cirurgia , Lasers de Excimer/uso terapêutico , Estudos Prospectivos , Topografia da Córnea/métodos , Córnea/cirurgia , Reagentes de Ligações Cruzadas/uso terapêutico , Fármacos Fotossensibilizantes/uso terapêutico , Ceratectomia Fotorrefrativa/métodos
10.
Surv Ophthalmol ; 69(1): 122-139, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37774800

RESUMO

Keratoconus is an ectatic corneal disorder that causes severe vision loss. Surgical options allow us to correct, partially or totally, the induced refractive error. Intracorneal ring segments (ICRS) implantation represents a minimally invasive surgical option that improves visual acuity, with a high success rate and a low overall complication rate. Corneal allogenic ICRS consists of ring segments derived from allogenic eye bank-processed donor corneas. Selective topography-guided transepithelial photorefractive or phototherapeutic keratectomy combined with CXL is another way in selected cases to improve spectacles corrected distance visual acuity. The microphotoablative remodeling of the central corneal profile is generally planned by optimizing the optical zones and minimizing tissue consumption. Phakic intraocular lens (PIOL) implant is considered in patients with stable disease and acceptable anatomical requirements. The two types of pIOLs, depending on their implantation inside the eye, are anterior chamber-pIOLs, which fixate to the anterior surface of the iris by using a polymethomethacrolate claw at the two haptics, and posterior chamber-pIOLs. In patients with both cataracts and keratoconus, the correct IOL power is difficult to obtain due to the irregular corneal shape and K values. Toric IOL is recommended, but carefully judging the topography and the possible need of subsequent keratoplasties.


Assuntos
Ceratocone , Implantação de Prótese , Humanos , Ceratocone/cirurgia , Ceratocone/tratamento farmacológico , Fármacos Fotossensibilizantes/uso terapêutico , Substância Própria , Acuidade Visual , Topografia da Córnea , Reagentes de Ligações Cruzadas/uso terapêutico , Refração Ocular
11.
J Clin Med ; 13(6)2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38541844

RESUMO

Background: To evaluate the effects of 10% GlicoPro tear substitute therapy in patients with severe dry eye disease (DED). Methods: In this prospective longitudinal study, 30 individuals receiving 10% GlicoPro four times daily for DED were evaluated. The ocular surface disease index (OSDI) questionnaire, average non-invasive break-up time (A-NIBUT), non-anesthetic and anesthetic corneal esthesiometry (CE), ocular pain, and the presence of conjunctivochalasis (CCH) were used as clinical endpoints. Treatment compliance using dosing diaries and AEs was assessed. Results: A significant improvement was observed in the clinical endpoints: the ΔOSDI questionnaire was -39.27 ± 13.22 [-65 to -15] points, ΔA-NIBUT was 3.10 ± 1.31 [1 to 5] s, Δnon-anesthetic CE was 14 ± 6.35 [5 to 25] mm, and Δanesthetic CE was 13 ± 5.35 [5 to 20] mm (p < 0.001 for all comparisons). Ocular pain was reduced in 92.5% of the patients at the end of the follow-up. However, there was no change in the presence of CCH. In addition, all the patients were fully compliant with the dosing and no AEs related to the use of the 10% GlicoPro tear substitute were reported. Conclusions: The 10% GlicoPro tear substitute has the potential to achieve beneficial effects in ocular surface treatments.

12.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593262

RESUMO

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Assuntos
Ceratocone , Lentes Intraoculares , Facoemulsificação , Humanos , Ceratocone/diagnóstico , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Facoemulsificação/métodos , Óptica e Fotônica , Refração Ocular , Biometria/métodos
13.
Biomolecules ; 14(4)2024 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-38672407

RESUMO

Purpose: To characterize microbial keratitis diversity utilizing species richness and Shannon Diversity Index. Methods: Corneal impression membrane was used to collect samples. All swabs were processed and analyzed by Biolab Laboratory (level V-SSN Excellence: ISO 9001:2015), Biolab Srl (Ascoli Piceno, Italy). DNA extraction, library preparation, and sequencing were performed in all samples. After sequencing, low-quality and polyclonal sequences were filtered out by the Ion software. At this point, we employed Kraken2 for microbial community analysis in keratitis samples. Nuclease-free water and all the reagents included in the experiment were used as a negative control. The primary outcome was the reduction in bacterial DNA (microbial load) at T1, expressed as a percentage of the baseline value (T0). Richness and Shannon alpha diversity metrics, along with Bray-Curtis beta diversity values, were calculated using the phyloseq package in R. Principal coordinate analysis was also conducted to interpret these metrics. Results: 19 samples were included in the study. The results exhibited a motley species richness, with the highest recorded value surpassing 800 species. Most of the samples displayed richness values ranging broadly from under 200 to around 600, indicating considerable variability in species count among the keratitis samples. Conclusions: A significant presence of both typical and atypical bacterial phyla in keratitis infections, underlining the complexity of the disease's microbial etiology.


Assuntos
Biodiversidade , Ceratite , Ceratite/microbiologia , Humanos , Bactérias/genética , Bactérias/classificação , Bactérias/isolamento & purificação , DNA Bacteriano/genética , Microbiota/genética
14.
Front Med (Lausanne) ; 10: 1198246, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37671401

RESUMO

Purpose: To assess the preliminary clinical results of a new, progressively higher fluence-pulsed light Epi-On accelerated crosslinking nomogram (PFPL M Epi-On ACXL) in the treatment of progressive keratoconus (KC). Setting: Siena Crosslinking Center, Siena, Italy. Methods: A prospective pilot open, non-randomized interventional study, including 32 eyes of 32 young-adult patients over 26 years old with Stages I-III progressive KC undergoing PFPL M Epi-On ACXL, was conducted. Riboflavin loading was performed by using Paracel I 0.25% for 4 min and Paracel II 0.22% for 6 min. The Avedro KXL System (Glaukos-Avedro, Burlington, USA) was used for pulsed-light accelerated crosslinking (ACXL) at air room 21% oxygenation and 13 min of UV-A irradiation. The treatment fluence was set at 7.2 J/cm2, 8.6 J/cm2, and 10.0 J/cm2 in corneas with baseline pachymetry <420 µm (group 1: 8 eyes), ≥ 420 µm <460 µm (group 2, 11 eyes), and ≥ 460 µm (group 3, 13 eyes), respectively. Uncorrected distance visual acuity (UDVA), best-spectacle corrected visual acuity (BSCVA), Scheimpflug corneal tomography, and anterior segment OCT (AS-OCT) data were collected at baseline and postoperatively at 1, 3, and 6 months. Results: UDVA and BSCVA improved in all groups (P ≤ 0.05). Maximum keratometry values (K max) showed a significant decrease in the 10.0 J/cm2 group (Δ -1.68 D). The coma (HOAs) value improved significantly by the sixth month in all groups. OCT average demarcation lines were 211 ± 19 µm in group 1, 245 ± 23 µm in group 2, and 267 ± 21 µm in group 3. Conclusions: The preliminary results show that pachymetry-based PFPL M Epi-On ACXL nomogram stabilizes ectasia progression. Higher fluence Epi-On ACXL increases CXL penetration, with better functional outcomes in the absence of complications.

15.
Am J Ophthalmol ; 255: 170-177, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37478962

RESUMO

PURPOSE: To assess the long-term outcomes of corneal collagen cross-linking according to the Dresden protocol (S-CXL) in progressive pediatric keratoconus (KC). DESIGN: Retrospective, single-center noncomparative interventional study. METHODS: Patients aged <18 years who underwent S-CXL from June 2007 to January 2011 in Humanitas Clinical and Research Center, Rozzano, Milan, Italy, and completed at least 10 years of follow-up were included. Corrected distance visual acuity (CDVA), refraction, and tomography were evaluated at baseline and ≥10 years after S-CXL. Meeting 2 of the following 3 criteria indicated reprogression: progression above 95% CI for post-CXL population of A or B values or a decrease in minimal thickness C evaluated with the ABCD display. RESULTS: Thirty-eight eyes of 24 patients fulfilled inclusion criteria. At a mean of 11.6 years postoperation (maximum 14 years), the CDVA improved significantly (from 0.703 ± 0.33 decimal fraction to 0.887 ± 0.2, P < .001). Similarly, the A value significantly improved from 2.550 ± 1.7 to 1.627 ± 1.68 (P = .019). Thirteen eyes (34%) showed significant postoperative progression in 2 of the 3 parameters A, B, and C. Of these, only 3 eyes (7.9%) of 3 patients showed a statistically significant change in the A value. CONCLUSIONS: S-CXL proved to be a safe treatment for progressive KC in pediatric patients with an anterior curvature progression rate of up to 7.9% at ≥10 years of follow-up.

16.
Indian J Ophthalmol ; 71(12): 3723-3729, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37991313

RESUMO

Corneal allogenic intrastromal ring segments (CAIRS) refer to the intracorneal placement of fresh, unprocessed, processed, preserved, or packaged allogenic rings/segments of any type/length. We described uniform-thickness CAIRS previously. We now describe a new technique of customized CAIRS to personalize the flattening effect as per individual topography. A prospective interventional case series of patients with pericentral/ paracentral decentered cones and gradation of keratometry with one side steeper than the other was conducted. Individually customized tapered CAIRS with variable volume, arc length, taper length, and gradient of taper were implanted. In total, 32 eyes of 29 patients with at least 1-year follow-up were included. Special double-bladed trephines and a CAIRS customizer template allowed the creation of individually customized CAIRS. Mean uncorrected distance visual acuity (UDVA) and spectacle-corrected distance visual acuity improved from 0.22 to 0.47 (P = 0.000) and from 0.76 to 0.89 (P = 0.001), respectively. Significant improvement was seen in K1, K2, Km, Kmax, topographic astigmatism, Q-value, sphere, cylinder, spherical equivalent, Root Mean Square (RMS), Higher Order Aberrations (HOA), and vertical coma (P < 0.01, 0.05). There was no significant change in the width or height of CAIRS between 1 month and last visit on anterior-segment optical coherence tomography. Five eyes continued to remain at the same UDVA, 27 eyes had at least 2 lines, and 13 eyes had at least 3 or more lines improvement in UDVA. The maximum improvement in UDVA was 7 lines. A significant difference in flattening was obtained at different zones across the tapered CAIRS. Thus, differential flattening was achieved across the cone based on the customization plan. Personalized customization was possible for each cornea, unlike limited models of progressive-thickness synthetic segments. Allogenic nature, greater customizability, efficacy, and absent need for large inventories are advantages compared to synthetic segments.


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Ceratocone/cirurgia , Estudos Prospectivos , Implantação de Prótese/métodos , Substância Própria/cirurgia , Topografia da Córnea , Refração Ocular , Próteses e Implantes
17.
Eye Vis (Lond) ; 10(1): 36, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37653457

RESUMO

BACKGROUND: This study aimed to compare the complication rates of epithelium-off corneal cross-linking (epi-off CXL) performed in an office-based setting with those of epi-off CXL performed in an operating room. METHODS: A retrospective cohort study, comprising 501 consecutive epi-off CXL procedures, performed in a non-sterile procedure room without laminar flow ventilation at the ELZA Institute in Zurich, Switzerland, between November 2015 and October 2021, was conducted. RESULTS: No cases of postoperative infectious keratitis were observed, while sterile infiltrates occurred in 10 out of 501 (2.00%) patients, all of whom responded well to topical steroid therapy. Delayed epithelialization (> 7 days) occurred in 14 out of 501 (2.79%) patients. No other adverse events were noted. CONCLUSIONS: Office-based epi-off CXL does not appear to be associated with an increased risk of complications when compared to operating room settings.

18.
J Ophthalmol ; 2023: 6677932, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37842327

RESUMO

Aim: To establish the diagnostic accuracy of corneal and epithelial thickness measurements obtained by spectral-domain optical coherence tomography (SD-OCT) in detecting keratoconus (KC) and suspect keratoconus (SKC). Methods: This retrospective study reviewed the data of 144 eyes separated into three groups by the Sirius automated corneal classification software: normal (N) (n = 65), SKC (n = 43), and KC (n = 36). Corneal thickness (CT) and epithelial thickness (ET) in the central (0-2 mm) and paracentral (2-5 mm) zones were obtained with the Cirrus high-definition OCT. Areas under the curve (AUC) of receiver operator characteristic (ROC) curves were compared across groups to estimate their discrimination capacity. Results: ROC curve analysis revealed excellent predictive ability for ET variables: minimum (Min) ET (0_2), minimum-maximum (Min-Max) ET (0_2), superonasal-inferotemporal (SN-IT) ET (2_5), Min-Max ET (2_5), and Min ET (2_5) to detect keratoconus (AUC > 0.9, all). Min-Max CT (0_2) was the only CT parameter with excellent ability to discriminate between KC and N eyes (AUC = 0.94; cutoff = ≤-32 µm). However, both ET and CT variables were not strong enough (AUC < 0.8, all) to differentiate between SKC and N eyes, with the highest diagnostic power for Min-Max ET (2_5) (AUC = 0.71; cutoff = ≤-9 µm) and central corneal thickness (CCT) (AUC = 0.76; cutoff = ≤533 µm). Conclusion: These results demonstrate that OCT-derived CT and ET are able to differentiate between KC and N eyes, with a high level of certainty. However, Min-Max ET (2_5) was the parameter with the highest ability to detect suspect keratoconus.

19.
J Clin Med ; 12(19)2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37834997

RESUMO

In the field of Ophthalmology, the mNGS 16S rRNA sequencing method of studying the microbiota and ocular microbiome is gaining more and more weight in the scientific community. This study aims to characterize the ocular microbiota of patients diagnosed with keratoconus who have not undergone any prior surgical treatment using the mNGS 16S rRNA sequencing method. Samples of naïve keratoconus patients were collected with an eNAT with 1 mL of Liquid Amies Medium (Copan Brescia, Italy), and DNA was extracted and analyzed with 16S NGS. The microbiota analysis showed a relative abundance of microorganisms at the phylum level in each sample collected from 38 patients with KC and 167 healthy controls. A comparison between healthy control and keratoconus samples identified two genera unique to keratoconus, Pelomonas and Ralstonia. Our findings suggest that alterations in the microbiota may play a role in the complex scenario of KC development.

20.
Biomedicines ; 11(12)2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38137498

RESUMO

Purpose: The purpose of this study was to check the efficacy and safety of a novel tear substitute containing hyaluronic acid and low-dose hydrocortisone in the treatment of moderate dry eye disease. Methods: In this prospective randomized study, 38 patients with moderate dry eye disease were divided into two treatment groups: Group 1 received one drop of 0.2% sodium hyaluronate and 0.001% hydrocortisone four times daily for 3 months, while Group 2 received 0.15% sodium hyaluronate and 3% trehalose at the same dosage. OSDI and SANDE questionnaires, Non-Invasive Break-Up time (NIBUT), Tear Meniscus Height (TMH), meibography, Lipid Layer Thickness (LLT), Tear Break-Up Time (TBUT), Corneal Staining Score (CFS), and Intraocular Pressure (IOP) were evaluated at baseline and after 1, 2, and 3 months of treatment. Results: During the treatment period, Group 1 showed statistically significant improvement in OSDI score (p = 0.002), SANDE score (p = 0.01), NIBUT (p < 0.0001), LLT (p < 0.0001), TBUT (p = 0.01), and CFS (p = 0.02). In Group 2, significant improvement was observed only in the TBUT score (p < 0.05). Comparison of the two groups showed that NIBUT and LLT were significantly different at the end of treatment (p = 0.001 for both comparisons), with more favorable results for sodium hyaluronate and hydrocortisone than for sodium hyaluronate and trehalose. No significant variations in intraocular pressure were observed in either group during the treatment period (p > 0.05). Conclusions: The study confirms that a 3-months treatment with hyaluronic acid 0.2% in combination with low-dose hydrocortisone 0.001% improves the signs and symptoms of moderate DED and that a low-dosage 0.001% hydrocortisone can be helpful in preventing the progression to chronic stages of DED.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA