Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Resuscitation ; 185: 109738, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36806652

RESUMO

BACKGROUND: Quality of chest compressions (CC) during cardiopulmonary resuscitation (CPR) often do not meet guideline recommendations for rate and depth. This may be due to the fatiguing nature of physically compressing a patient's chest, meaning that CPR quality reduces over time. OBJECTIVE: This analysis investigates the effect of CPR duration on the performance of continuous CCs delivered by firefighters equipped with CPR feedback devices. METHODS: Data were collected from a first responder group which used CPR feedback and automatic external defibrillator devices when attending out-of-hospital cardiac arrest events. Depth and rate of CC were analysed for 134 patients. Mean CC depth and rate were calculated every 5 s during two-minute episodes of CPR. Regression models were created to evaluate the relationship between applied CC depth and rate as a function of time. RESULTS: Mean (SD) CC depth during the investigation was 48 (9) mm. An inverse relationship was observed between CC depth and CPR duration, where CC depth decreased by 3.39 mm, over two-minutes of CPR (p < 0.001). Mean (SD) CC rate was 112.06 (5.87) compressions per minute. No significant relationship was observed between CC rate and CPR duration (p = 0.077). Mean depth was within guideline range for 33.58% of patient events, while guideline rate was observed in 92.54% of cases. CONCLUSIONS: A reduction in CC depth was observed during two-minutes of continuous CCs while CC rate was not affected. One third of patients received a mean CC depth within guideline range (50 to 60 mm).


Assuntos
Reanimação Cardiopulmonar , Bombeiros , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/terapia , Desfibriladores , Fatores de Tempo
2.
Comput Methods Programs Biomed ; 241: 107780, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37651816

RESUMO

BACKGROUND AND OBJECTIVE: Quantitative measures extracted from ventricular fibrillation (VF) waveform reflect the metabolic state of the myocardium and are associated with survival outcome. The quality of delivered chest compressions during cardiopulmonary resuscitation are also linked with survival. The aim of this research is to explore the viability and effectiveness of a thoracic impedance (TI) based chest compression (CC) guidance system to control CC depth within individual subjects and influence VF waveform properties. METHODS: This porcine investigation includes an analysis of two protocols. CC were delivered in 2 min episodes at a constant rate of 110 CC min-1. Subject-specific CC depth was controlled using a TI-thresholding system where CC were performed according to the amplitude (ZRMS, 0.125 to 1.250 Ω) of a band-passed TI signal (ZCC). Protocol A was a retrospective analysis of a 12-porcine study to characterise the response of two VF waveform metrics: amplitude spectrum area (AMSA) and mean slope (MS), to varying CC quality. Protocol B was a prospective 12-porcine study to determine if changes in VF waveform metrics, due to CC quality, were associated with defibrillation outcome. RESULTS: Protocol A: A directly proportional relationship was observed between ZRMS and CC depth applied within each subject (r = 0.90; p <0.001). A positive relationship was observed between ZRMS and both AMSA (p <0.001) and MS (p <0.001), where greater TI thresholds were associated with greater waveform metrics. PROTOCOL B: MS was associated with return of circulation following defibrillation (odds ratio = 2.657; p = 0.043). CONCLUSION: TI-thresholding was an effective way to control CC depth within-subjects. Compressions applied according to higher TI thresholds evoked an increase in AMSA and MS. The response in MS due to deeper CC resulted in a greater incidence of ROSC compared to shallow chest compressions.


Assuntos
Amsacrina , Fibrilação Ventricular , Suínos , Animais , Fibrilação Ventricular/terapia , Impedância Elétrica , Estudos Prospectivos , Estudos Retrospectivos
3.
Resusc Plus ; 9: 100203, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35146463

RESUMO

AIM: Automated external defibrillators (AEDs) use various shock protocols with different characteristics when deployed in pediatric mode. The aim of this study is to assess and compare the safety and efficacy of different AED pediatric protocols using novel experimental approaches. METHODS: Two defibrillation protocols (A and B) were assessed across two studies: Protocol A: escalating (50-75-90 J) defibrillation waveform with higher voltage, shorter duration and equal phase durations. Protocol B; non-escalating (50-50-50 J) defibrillation waveform with lower voltage, longer duration and unequal phase durations.Experiment 1: Isolated shock damage was assessed following shocks to 12 anesthetized pigs. Animals were randomized into two groups, receiving three shocks from Protocol A (50-75-90 J) or B (50-50-50 J). Cardiac function, cardiac troponin I (cTnI), creatine phosphokinase (CPK) and histopathology were analyzed. Experiment 2: Defibrillation safety and efficacy were assessed through shock success, ROSC, ST-segment deviation and contractility following 16 randomized shocks from protocol A or B delivered to 10 anesthetized pigs in VF. RESULTS: Experiment 1: No clinically meaningful difference in cTnI, CPK, ST-segment deviation, ejection fraction or histopathological damage was observed following defibrillation with either protocol. No difference was observed between protocols at any timepoint. Experiment 2: all defibrillation types demonstrated shock success and ROSC ≥ 97.5%. Post-ROSC contractility was similar between protocols. CONCLUSIONS: There is no evidence that administration of clinically relevant shock sequences, without experimental confounders, result in significant myocardial damage in this model of pediatric resuscitation. Typical variations in AED pediatric mode settings do not affect defibrillation safety and efficacy.

4.
Open Heart ; 7(1)2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32513668

RESUMO

BACKGROUND: Public access defibrillators (PADs) represent unique life-saving medical devices as they may be used by untrained lay rescuers. Collecting representative clinical data on these devices can be challenging. Here, we present results from a retrospective observational cohort study, describing real-world PAD utilisation over a 5-year period. METHODS: Data were collected between October 2012 and October 2017. Responders voluntarily submitted electronic data downloaded from HeartSine PADs, and patient demographics and other details using a case report form in exchange for a replacement battery and electrode pack. RESULTS: Data were collected for 977 patients (692 males, 70.8%; 255 females, 26.1%; 30 unknown, 3.1%). The mean age (SD) was 59 (18) years (range <1 year to 101 years). PAD usage occurred most commonly in homes (n=328, 33.6%), followed by public places (n=307, 31.4%) and medical facilities (n=128, 13.1%). Location was unknown in 40 (4.09%) events. Shocks were delivered to 354 patients. First shock success was 312 of 350 patients where it could be determined (89.1%, 95% CI 85.4% to 92.2%). Patients with reported response times ≤5 min were more likely to survive to hospital admission (89/296 (30.1%) vs 40/250 (16.0%), p<0.001). Response time was unknown for 431 events. CONCLUSION: This is the first study to report global PAD usage in voluntarily submitted, unselected real-world cases and demonstrates the real-world effectiveness of PADs, as confirmed by first shock success.


Assuntos
Desfibriladores , Cardioversão Elétrica/instrumentação , Acessibilidade aos Serviços de Saúde , Parada Cardíaca Extra-Hospitalar/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/mortalidade , Parada Cardíaca Extra-Hospitalar/fisiopatologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Tempo , Tempo para o Tratamento , Resultado do Tratamento , Adulto Jovem
5.
Resuscitation ; 96: 114-20, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26234892

RESUMO

OBJECTIVE: Optimising the depth and rate of applied chest compressions following out of hospital cardiac arrest is crucial in maintaining end organ perfusion and improving survival. The impedance cardiogram (ICG) measured via defibrillator pads produces a characteristic waveform during chest compressions with the potential to provide feedback on cardiopulmonary resuscitation (CPR) and enhance performance. The objective of this pre-clinical study was to investigate the relationship between mechanical and physiological markers of CPR efficacy in a porcine model and examine the strength of correlation between the ICG amplitude, compression depth and end-tidal CO2 (ETCO2). METHODS: Two experiments were performed using 24 swine (12 per experiment). For experiment 1, ventricular fibrillation (VF) was induced and mechanical CPR commenced at varying thrusts (0-60 kg) for 2 min intervals. Chest compression depth was recorded using a Philips QCPR device with additional recording of invasive physiological parameters: systolic blood pressure, ETCO2, cardiac output and carotid flow. For experiment 2, VF was induced and mechanical CPR commenced at varying depths (0-5 cm) for 2 min intervals. The ICG was recorded via defibrillator pads attached to the animal's sternum and connected to a Heartsine 500 P defibrillator. ICG amplitude, chest compression depth, systolic blood pressure and ETCO2 were recorded during each cycle. In both experiments the within-animal correlation between the measured parameters was assessed using a mixed effect model. RESULTS: In experiment 1 moderate within-animal correlations were observed between physiological parameters and compression depth (r=0.69-0.77) and thrust (r=0.66-0.82). A moderate correlation was observed between compression depth and thrust (r=0.75). In experiment 2 a strong within-animal correlation and moderate overall correlations were observed between ICG amplitude and compression depth (r=0.89, r=0.79) and ETCO2 (r=0.85, r=0.64). CONCLUSION: In this porcine model of induced cardiac arrest moderate within animal correlations were observed between mechanical and physiological markers of chest compression efficacy demonstrating the challenge in utilising a single mechanical metric to quantify chest compression efficacy. ICG amplitude demonstrated strong within animal correlations with compression depth and ETCO2 suggesting its potential utility to provide CPR feedback in the out of hospital setting to improve performance.


Assuntos
Cardiografia de Impedância/métodos , Reanimação Cardiopulmonar/métodos , Monitorização Fisiológica/métodos , Parada Cardíaca Extra-Hospitalar/terapia , Animais , Reanimação Cardiopulmonar/normas , Modelos Animais de Doenças , Masculino , Parada Cardíaca Extra-Hospitalar/fisiopatologia , Suínos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA