Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-26764216

RESUMO

Research is of key importance in delivering high-quality patient care through evidence-based practice. Attitude towards research and barriers to research can have an impact on research activity. A survey was conducted to establish the levels of research awareness and attitudes among clinical staff groups in this regional cancer centre and identify any barriers to participation in research. The survey consisted of 26 questions and was distributed electronically and completed online. The response rate was 22.3% (n = 123). All participants felt that clinical research will help the regional cancer centre develop and progress treatments in the future. A positive attitude towards research was evident and consistent across professional groups. The main identified barriers to research included lacking the required knowledge, skills and training, lacking support from managers, and lack of opportunity or time to be involved in research, in particular for allied health professionals. However, there appears to be the foundation of a healthy research culture for nurses supported by management. The results of the survey support the implementation of an action plan based on the recommendations of this journal article.


Assuntos
Atitude do Pessoal de Saúde , Pesquisa Biomédica , Institutos de Câncer , Corpo Clínico Hospitalar , Recursos Humanos de Enfermagem Hospitalar , Pessoal Técnico de Saúde , Conscientização , Humanos , Inquéritos e Questionários
2.
Clin Transl Radiat Oncol ; 2: 13-18, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29657994

RESUMO

INTRODUCTION AND BACKGROUND: A significant proportion of patients with intermediate and high risk squamous cell cancer of the oropharynx (OPSCC) continue to relapse locally despite radical chemoradiotherapy (CRT). The toxicity of the current combination of intensified dose per fraction radiotherapy and platinum based chemotherapy limits further uniform intensification. If a predictive biomarker for outcomes from CRT can be identified during treatment then individualised and adaptive treatment strategies may be employed. METHODS/DESIGN: The MeRInO study is a prospective observational imaging study of patients with intermediate and high risk, locally advanced OPSCC receiving radical RT or concurrent CRT Patients undergo diffusion weighted MRI prior to treatment (MRI_1) and during the third week of RT (MRI_2). Apparent diffusion coefficient (ADC) measurements will be made on each scan for previously specified target lesions (primary and lymph nodes) and change in ADC calculated. Patients will be followed up and disease status for each target lesion noted. The primary aim of the MeRInO study is to determine the threshold change in ADC from baseline to week 3 of RT that may identify the sub-group of non-responders during treatment. DISCUSSION: The use of DW-MRI as a predictive biomarker during RT for SCC H&N is in its infancy but studies to date have found that response to treatment may indeed be predicted by comparison of DW-MRI carried out before and during treatment. However, previous studies have included all sub-sites and biological sub-types. Establishing ADC thresholds that predict for local failure is an essential step towards using DW-MRI to improve the therapeutic ratio in treating SCC H&N. This would be done most robustly in a specific H&N sub-site and in sub-types with similar biological behaviour. The MeRInO study will help establish these thresholds in OPSCC.

3.
Radiother Oncol ; 59(3): 311-8, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11369073

RESUMO

BACKGROUND AND PURPOSE: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation. METHODS: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage. RESULTS: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5+/-5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4+/-3.5% and normal tissue over-coverage of 25.4+/-4.2%. CONCLUSIONS: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Simulação por Computador/estatística & dados numéricos , Neoplasias Pulmonares/radioterapia , Cuidados Paliativos , Interface Usuário-Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Reprodutibilidade dos Testes , Resultado do Tratamento
4.
Phys Med Biol ; 44(8): 1863-73, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10473200

RESUMO

Few quantitative data are available on the kinetics of polymerization reactions in polymer gel (PAG) dosimeters and their long-term stability. Post-irradiation polymerization reactions have been found to continue for several weeks, posing questions regarding dosimeter stability and its achievement. In this paper we report an investigation of polymerization kinetics in PAG dosimeters and the effect of diffusing oxygen into the dosimeter, post irradiation, as a potential method of inhibiting further polymerization and stabilizing the dose distribution. Results show continuous post-irradiation changes in transverse relaxation rate R2 with time over the five week study period and that a steady-state may not be reached for a period of months. An assessment is made of the appropriate time to image the dosimeter which shows that after three to four days the polymerization change is slow compared with imaging time. The implications of the time delay between irradiation and imaging are discussed in terms of the resultant sensitivity of the dosimeter and accuracy of the dose measured. In pairs of dosimeters, one sealed the other open to air, oxygen diffusing into the dosimeter arrests polymerization. However, the diffusion rate is too slow to make this method practicable. The slow diffusion means that while in regions near the air/gel interface polymerization is quickly arrested, in deeper regions it may continue for many hours, causing artefacts in the dose distribution. In the companion paper to this from a collaborating team, a study focusing on modelling oxygen diffusion in dosimeter gel will be presented.


Assuntos
Resinas Acrílicas/química , Modelos Teóricos , Radiometria/métodos , Resinas Acrílicas/síntese química , Relação Dose-Resposta à Radiação , Géis/síntese química , Géis/química , Oxigênio/análise , Imagens de Fantasmas , Polímeros/síntese química , Polímeros/química , Fatores de Tempo
5.
Phys Med Biol ; 43(10): 2709-20, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9814511

RESUMO

A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are irradiated separately with a 10 x 10 cm2 field end-on in a water bath, such that the characteristic depth-dose curve is recorded in the gel. The calibration is then determined by fitting the depth-dose measured in water, against the measured change in relaxivity with depth in the gel. Increased accuracy is achieved in this simple depth-dose geometry by averaging the relaxivity at each depth. A large number of calibration data points, each with relatively high accuracy, are obtained. Calibration data over the full range of dose (1.6-10 Gy) is obtained by irradiating one test-tube to 10 Gy at dose maximum (Dmax), and the other to 4.5 Gy at Dmax. The new calibration method is compared with a 'standard method' where five identical test-tubes of gel were irradiated to different known doses between 2 and 10 Gy. The percentage uncertainties in the slope and intercept of the calibration fit are found to be lower with the new method by a factor of about 4 and 10 respectively, when compared with the standard method and with published values. The gel was found to respond linearly within the error bars up to doses of 7 Gy, with a slope of 0.233 +/- 0.001 s(-1) Gy(-1) and an intercept of 1.106 +/- 0.005 Gy. For higher doses, nonlinear behaviour was observed.


Assuntos
Calibragem , Géis/efeitos da radiação , Polímeros/efeitos da radiação , Radiometria/métodos , Acrilamidas/efeitos da radiação , Braquiterapia , Gelatina/efeitos da radiação , Espectroscopia de Ressonância Magnética/métodos , Radiometria/instrumentação , Radioterapia
6.
Phys Med Biol ; 45(5): 1195-210, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10843100

RESUMO

The reproducibility of polyacrylamide gel (PAG) dosimetry has been evaluated when used to verify two radiotherapy treatment plans of increasing complexity. The plans investigated were a three-field coplanar arrangement, using the linac jaws for field shaping, and a four-field, conformal, non-coplanar plan using precision-cast lead alloy shielding blocks. Each treatment was performed three times using phantoms and calibration gels manufactured in-house. Two phantoms were specially designed for this work to aid accurate positioning of the gels for irradiation and imaging. All gels were imaged post-irradiation using a Siemens Vision 1.5T MR scanner. T2 relaxation images were calibrated to absorbed dose distributions using a number of smaller calibration vessels to produce distribution maps of relative dose. The relative dose distributions were found to be reproducible, with the standard deviation on the mean areas enclosed by the > or = 50% isodose lines measured in three orthogonal planes being 6.4% and 4.1% for the coplanar and non-coplanar plans respectively. The measured distributions were also consistent with those planned, with isodose lines generally agreeing to within a few millimetres. However, the measured absolute doses were on average 23.5% higher than those planned. Although the polyacrylamide gel dosimetry technique has some limitations, particularly when calibrating distributions to absolute dose, the ability to resolve sharp dose gradients in three dimensions with millimetre precision is invaluable when verifying complex conformal treatment plans, where avoidance of proximal, critical structures is a treatment criterion.


Assuntos
Radiometria/métodos , Radioterapia Conformacional/métodos , Resinas Acrílicas , Fenômenos Biofísicos , Biofísica , Desenho de Equipamento , Géis , Humanos , Imageamento por Ressonância Magnética , Neoplasias/radioterapia , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes
7.
Phys Med Biol ; 43(5): 1113-32, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9623644

RESUMO

BANG-gel dosimetry offers the potential for measuring the dose delivered by a radiotherapy treatment technique, in three dimensions, with high spatial resolution and good accuracy. The ability to measure comprehensively a 3D dose distribution is a major advantage of the gel dosimeter over conventional planar and point-based dosimeter devices, particularly when applied to the verification of complex dose distributions characteristic of intensity-modulated radiotherapy (IMRT). In this paper an in-house manufactured BANG-gel dosimeter was applied to study the dose distributions of two irradiation experiments for which the distributions were known: (i) a dosimetrically simple parallel-opposed irradiation, and (ii) a more complex nine-field 'static tomotherapy' intensity-modulated irradiation delivered with the Nomos MIMiC. The uniform distribution in (i) allowed a study of the magnetic resonance (MR) imaging parameters to achieve an optimal trade-off between noise and image resolution (optimum image resolution for the Siemens 1.5T Vision system was determined to be approximately 0.8 mm2 with a slice thickness of 2 mm). The spatial uniformity of gel sensitivity to radiation was found to depend strongly on the presence of oxygen, which must be eliminated for the gel dosimeter to be of use. The gel dosimeter was found to agree well with predicted dose distributions and accurately measured the steep penumbral fall-off of dose, even after many days, proving its potential for the verification of IMRT distributions. In the nine-field IMRT delivery (ii) the predicted dose was computed by both an in-house 'component-delivery' dose algorithm and the Peacock planning-system dose algorithm. Good agreement was found between the two algorithms despite the latter's omission of the change in penumbral characteristics with aperture-size during delivery, lack of inhomogeneity correction and approximate modelling of leaf leakage. These effects were found to be small for the problem studied. The predicted distribution agreed well with the gel-measured distribution at medium and high doses (50-90% isodose lines) although differences of up to 10% were observed at lower doses (30% isodose line). The gel dosimeter was found to have the potential to verify IMRT distributions but required considerable care to achieve accurate results. Attention was required to achieve uniformity of gel sensitivity (to prevent oxygen contamination), and in the calibration process.


Assuntos
Géis , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Acrilamida , Acrilamidas , Calibragem , Gelatina , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador , Dosagem Radioterapêutica , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Água
8.
Phys Med Biol ; 44(10): 2431-44, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10533920

RESUMO

It is well known that the experimental dosimetry of brachytherapy sources presents a challenge. Depending on the particular-dosimeter used, measurements can suffer from poor spatial resolution (ion chambers), lack of 3D information (film) or errors due to the presence of the dosimeter itself distorting the radiation flux. To avoid these problems, we have investigated the dosimetry of a clinical 192Ir source using a polyacrylamide gel (PAG) dosimeter. Experimental measurements of dose versus radial distance from the centre of the source (cross-line plots) were compared with calculations produced with a Nucletron NPS planning system. Good agreement was found between the planning system and gel measurements in planes selected for analysis. Gel dosimeter measurements in a coronal plane through the phantom showed a mean difference between measured absorbed dose and calculated dose of 0.17 Gy with SD = 0.13 Gy. Spatially, the errors at the reference point remain within one image pixel (1.0 mm). The use of polymer gel dosimetry shows promise for brachytherapy applications, offering complete, three-dimensional dose information, good spatial resolution and small measurement errors. Measurements close to the source, however, are difficult, due to some of the limiting properties of the polyacrylamide gel.


Assuntos
Resinas Acrílicas , Braquiterapia/métodos , Radioisótopos de Irídio/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Calibragem , Géis , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Magn Reson Imaging ; 15(3): 319-22, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9201679

RESUMO

MRI scanning generates high levels of acoustic noise that cannot only pose a safety hazard, but also impair communication between staff and patient. In this article we present active noise control (ANC) techniques that introduce antiphase noise to destructively interfere with the MRI noise and with the aim of producing a zone of quiet around the patient's ears. Using noise recorded from a 1.0 Tesla midfield MR scanner the acoustic noise generated by three standard MR imaging sequences was replayed to a real time two channel ANC system. The results obtained show a useful attenuation of low-frequency periodic acoustic noise components. Therefore, in combination with standard passive ear protection, this suggests that MR generated acoustic noise can be effectively attenuated at both low and high frequencies leading to improved patient comfort.


Assuntos
Imageamento por Ressonância Magnética , Ruído/prevenção & controle , Acústica/instrumentação , Algoritmos , Comunicação , Dispositivos de Proteção das Orelhas , Retroalimentação , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Masculino , Ruído/efeitos adversos , Relações Profissional-Paciente , Segurança , Processamento de Sinais Assistido por Computador/instrumentação
10.
Br J Radiol ; 67(796): 413-5, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8173889

RESUMO

Although much has been published concerning the various safety risks associated with magnetic resonance (MR) imaging, little mention is made of the acoustic noise generated during scanning. The existing data are now out of date with regard to currently used imaging protocols and technology. Out of concern for patient safety, measurements were made of the acoustic noise generated during various scan protocols on a high field (1.5 T) Siemens MR imager. These data were compared with published data. The data show that for certain protocols, the exposure to acoustic noise falls outside safety guidelines unless ear protection is used.


Assuntos
Imageamento por Ressonância Magnética , Ruído , Dispositivos de Proteção das Orelhas , Humanos , Segurança
11.
Br J Radiol ; 73(873): 919-29, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11064643

RESUMO

New, complex radiotherapy delivery techniques require dosimeters that are able to measure complex three-dimensional dose distributions accurately and with good spatial resolution. Polymer gel is an emerging new dosimeter being applied to these challenges. The aim of this review is to present a practical overview of polymer gel dosimetry, including gel manufacture, imaging, calibration and application to radiotherapy verification. The dosimeters consist of a gel matrix within which is suspended a solution of acrylic molecules. These molecules polymerize upon exposure to radiation, with the degree of polymerization being proportional to absorbed dose. The polymer distribution can be measured in two or three dimensions using MRI or optical tomography and, after calibration, the images can be converted into radiation dose distributions. Manufacture of the gel is reported to be reproducible, and measured dose in the range 0-10 Gy is accurate to within 3-5%. In-plane image resolution of 1 mm x 1 mm, with image slice thicknesses of between 2-5 mm, is typically achievable using clinical 1.5 T MR scanners and standard T2 weighted imaging sequences. The gels have been used to verify a number of conventional and novel radiotherapy modalities, including brachytherapy, intensity modulated radiotherapy and stereotactic radiosurgery. All the studies have confirmed the value and versatility of the dosimetry technique.


Assuntos
Acrilamida , Gelatina , Géis/síntese química , Polímeros/síntese química , Radiometria/métodos , Calibragem , Falha de Equipamento , Imageamento por Ressonância Magnética , Radiometria/instrumentação , Reprodutibilidade dos Testes
12.
Br J Radiol ; 85(1020): e1256-62, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23175491

RESUMO

OBJECTIVE: To investigate the necessity of performing MRI in the radiotherapy position when using MRI for prostatic radiotherapy. METHODS: 20 prostate patients received a CT, diagnostic MRI and an MRI scan in the radiotherapy position. The quality of registration between CT and MRI was compared between the two MRI set-ups. The prostate and seminal vesicles were contoured using all scans and intensity modulated radiotherapy (IMRT) plans were generated. Changes in the target volume and IMRT plans were investigated. Two-tailed paired Student's t-tests determined the statistical significance. RESULTS: There was a decrease in the mean distance from the centre of the bony anatomy between CT and MRI (from 3.9 to 1.9 mm, p-value<0.0001) when the MRI scan was acquired in the radiotherapy position. Assuming that registering CT with an MRI scan in the radiotherapy position is the gold standard for delineating the prostate and seminal vesicles, using a planning target volume delineated on the CT with a diagnostic MRI scan viewed separately, resulted in a mean conformation number of 0.80 instead of the expected 0.98 (p<0.0001). CONCLUSION: By registering CT with an MRI scan in the radiotherapy position, there is a statistically significant improvement in the registration and IMRT quality. ADVANCES IN KNOWLEDGE: To achieve an acceptable registration and IMRT quality in prostatic radiotherapy, neither CT with a separate diagnostic MRI nor CT registered to a diagnostic MRI will suffice. Instead, a CT registered with an MRI in the radiotherapy position should be used.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Idoso , Relação Dose-Resposta a Droga , Humanos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Neoplasias da Próstata/patologia , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
13.
Br J Radiol ; 84(1004): 750-5, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21750138

RESUMO

OBJECTIVES: To improve the integration of MRI with radiotherapy treatment planning, our department fabricated a flat couch top for our MR scanner. Setting up using this couch top meant that the patients were physically higher up in the scanner and, posteriorly, a gap was introduced between the patient and radiofrequency coil. METHODS: Phantom measurements were performed to assess the quantitative impact on image quality. A phantom was set up with and without the flat couch insert in place, and measurements of image uniformity and signal to noise were made. To assess clinical impact, six patients with pelvic cancer were recruited and scanned on both couch types. The image quality of pairs of scans was assessed by two consultant radiologists. RESULTS: The use of the flat couch insert led to a drop in image signal to noise of approximately 14%. Uniformity in the anteroposterior direction was affected the most, with little change in right-to-left and feet-to-head directions. All six patients were successfully scanned on the flat couch, although one patient had to be positioned with their arms by their sides. The image quality scores showed no statistically significant change between scans with and without the flat couch in place. CONCLUSION: Although the quantitative performance of the coil is affected by the integration of a flat couch top, there is no discernible deterioration of diagnostic image quality, as assessed by two consultant radiologists. Although the flat couch insert moved patients higher in the bore of the scanner, all patients in the study were successfully scanned.


Assuntos
Imageamento por Ressonância Magnética/normas , Posicionamento do Paciente/métodos , Neoplasias da Próstata/diagnóstico , Planejamento da Radioterapia Assistida por Computador/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Pelve , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Intensificação de Imagem Radiográfica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes
14.
Br J Radiol ; 83(992): 687-93, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20551253

RESUMO

Respiratory motion complicates target volume definition for patients with lung cancer. The use of slow CT to aid in the definition of moving target volumes was investigated. Standard and slow scans of an oscillating phantom were acquired using gantry rotation periods of 0.8 and 1.5 s and pitches of 0.95 and 0.50, respectively. The resultant images of three spheres within the phantom, labelled as A, B and C with diameters of 3.7, 2.8 and 2.2 cm, were analysed. The central co-ordinates of each volume were determined, and the ratio of the target volume outlined on CT (TV(CT)) to the true target volume (TV) was calculated. For 1.5 cm peak-to-trough (PTT) motion, standard CT mean ratios of 0.8, 0.8 and 0.7 were obtained for spheres A, B and C, respectively, whereas slow CT resulted in a mean ratio of 0.9 for all three spheres. For 2.5 cm motion, standard CT mean ratios of 0.8, 0.7 and 0.7 were obtained, whereas the slow CT mean ratios were 0.9, 0.9 and 0.8. The deviation of the central co-ordinate for the slow CT volumes was within 0.1 cm whereas deviations of up to 0.7 cm were seen using standard CT. This study indicates the potential benefit of using slow CT, even on modern scanners capable of rotation periods only down to 1.5 s, to define moving target volumes more accurately and reproducibly moving target volumes, and aid in the management of respiratory motion for patients with lung cancer.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Movimento , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Aumento da Imagem/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Mecânica Respiratória , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação
15.
Br J Radiol ; 79(944): 672-80, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16641422

RESUMO

The purpose of this study was to investigate the impact on localization of utilizing contrast-enhanced CT scans and the formal input of a radiologist in the planning process. 25 head and neck/brain patients had pre- and post-contrast CT scans in the treatment position. Radiotherapy treatment was planned on the unenhanced CT images as per standard practice. Retrospectively, their scans (unenhanced and enhanced) were re-contoured by two oncologists and a radiologist. These new contours were compared with the original unenhanced treatment contours and differences in contour volume, geographical isocentre position and tolerance coverage of the associated planning target volumes (PTVs) were evaluated using the original plans. The use of contrast enhanced CT data during localization by the oncologist shows little change in gross tumour volumes (GTVs) or PTVs, geographical position or tolerance coverage for the targets in the brain studied here. Larger changes in mean volume are seen for the head and neck cases alone. Changes are greater and statistically significant (p < 0.05, Wilcoxon signed rank test) for localization by the radiologist. Furthermore, when comparing the original PTV marked by the oncologist with a new PTV re-contoured by the oncologist, but based on a GTV marked-up by the radiologist, again statistically significant (p < 0.01) changes in percentage volume are noted. Intraoperator precision is good, percentage volume differences being of the order 3-6%. PTVs also show improved standard deviations compared with GTVs. Geographic shifts are generally within our departmental tolerance levels for daily patient setup. Comparing precision of unenhanced data with enhanced, mean percentage volume changes are smaller, but not statistically significant. The use of enhanced scan data for localization has little effect on size, geographical position or tolerance coverage of PTVs marked up by the oncologists in this study. However, more important is the input from a radiologist. Statistically significant differences due to mark-up on enhanced scans by the radiologist are shown. Furthermore, significant differences are also seen between PTVs based on oncologist-generated GTVs, and those based on radiologist-generated GTVs.


Assuntos
Neoplasias Encefálicas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/normas , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Radioterapia Conformacional/normas , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
16.
Clin Radiol ; 50(5): 331-4, 1995 May.
Artigo em Inglês | MEDLINE | ID: mdl-7743723

RESUMO

Although much has been published highlighting the safety risks of magnetic resonance imaging, little mention has been made of acoustic noise levels. As the clinically available gradient strengths of MR systems increase, acoustic noise levels will become more important. Measurements were made of the acoustic noise levels generated by magnetic resonance imaging on two high field systems (1.0T and 1.5T). These data were compared with those in the literature. On the 1.0T magnetic resonance system, comparisons were also made between data acquired using the standard gradient system (maximum levels of 10m T/m) and a new upgraded gradient system (maximum levels of 15m T/m). The results show that many sequences produce noise levels above the safe levels defined by the Department of Health and the Health and Safety Executive. Providing routine ear protection for patients is, therefore, important. Noise levels for the upgraded gradient system on the 1.0T scanner are in the range of 2 dB greater. As expected, noise levels generated were greater for the 1.5T magnetic resonance imager than on the 1.0T system.


Assuntos
Imageamento por Ressonância Magnética , Ruído , Protocolos Clínicos , Dispositivos de Proteção das Orelhas , Humanos , Imageamento por Ressonância Magnética/instrumentação , Segurança
17.
J Magn Reson Imaging ; 12(1): 37-45, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10931563

RESUMO

This review article discusses the various types of acoustic noise produced during the operation of MR systems, describes the characteristics of the acoustic noise, and presents information regarding noise control techniques. In addition, the problems related to acoustic noise for patients and healthcare workers are discussed.


Assuntos
Limiar Auditivo/fisiologia , Monitoramento Ambiental/métodos , Transtornos da Audição/etiologia , Imageamento por Ressonância Magnética/efeitos adversos , Ruído Ocupacional/efeitos adversos , Dispositivos de Proteção das Orelhas , Transtornos da Audição/prevenção & controle , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Monitorização Fisiológica/métodos , Saúde Ocupacional , Medição de Risco , Processamento de Sinais Assistido por Computador
18.
Magn Reson Med ; 17(1): 10-4, 1991 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-2067387

RESUMO

A simple high-pass cavity resonator has been constructed for NMR imaging use at 500 MHz. A capacitative circuit arrangement is used to drive the device. A novel split-coil or half-resonator design is also introduced for lower-frequency operation with applications in whole-body medical imaging.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Desenho de Equipamento , Humanos , Modelos Estruturais , Modelos Teóricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA