Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Proc Natl Acad Sci U S A ; 119(40): e2205942119, 2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36122198

RESUMO

Spiders, the most specious taxon of predators, have evolved an astounding range of predatory strategies, including group hunting, specialized silk traps, pheromone-loaded bolas, and aggressive mimicry. Spiders that hunt prey defended with behavioral, mechanical, or chemical means are under additional selection pressure to avoid injury and death. Ants are considered dangerous because they can harm or kill their predators, but some groups of spiders, such as the Theridiidae, have a very high diversification of ant-hunting species and strategies [J. Liu et al., Mol. Phylogenet. Evol. 94, 658-675 (2016)]. Here, we provide detailed behavioral analyses of the highly acrobatic Australian ant-slayer spider, Euryopis umbilicata (Theridiidae), that captures much larger and defended Camponotus ants on vertical tree trunks. The hunting sequence consists of ritualized steps performed within split seconds, resulting in an exceptionally high prey capture success rate.


Assuntos
Formigas , Comportamento Predatório , Aranhas , Animais , Austrália , Feromônios , Comportamento Predatório/fisiologia , Seda , Aranhas/fisiologia , Árvores
2.
J Evol Biol ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38843076

RESUMO

Statistical analysis and data visualisation are integral parts of science communication. One of the major issues in current data analysis practice is an over-dependency on - and misuse of - p-values. Researchers have been advocating for the estimation and reporting of effect sizes for quantitative research to enhance the clarity and effectiveness of data analysis. Reporting effect sizes in scientific publications has until now been mainly limited to numeric tables, even though effect size plotting is a more effective means of communicating results. We have developed the Durga R package for estimating and plotting effect sizes for paired and unpaired group comparisons. Durga allows users to estimate unstandardised and standardised effect sizes and bootstrapped confidence intervals of the effect sizes. The central functionality of Durga is to combine effect size visualisations with traditional plotting methods. Durga is a powerful statistical and data visualisation package that is easy to use, providing the flexibility to estimate effect sizes of paired and unpaired data using different statistical methods. Durga provides a plethora of options for plotting effect size, which allows users to plot data in the most informative and aesthetic way. Here, we introduce the package and its various functions. We further describe a workflow for estimating and plotting effect sizes using example data sets.

3.
Anim Cogn ; 27(1): 39, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789697

RESUMO

The Australian red honey ant, Melophorus bagoti, stands out as the most thermophilic ant in Australia, engaging in all outdoor activities during the hottest periods of the day during summer months. This species of desert ants often navigates by means of path integration and learning landmark cues around the nest. In our study, we observed the outdoor activities of M. bagoti workers engaged in nest excavation, the maintenance of the nest structure, primarily by taking excess sand out of the nest. Before undertaking nest excavation, the ants conducted a single exploratory walk. Following their initial learning expedition, these ants then engaged in nest excavation activities. Consistent with previous findings on pre-foraging learning walks, after just one learning walk, the desert ants in our study demonstrated the ability to return home from locations 2 m away from the nest, although not from locations 4 m away. These findings indicate that even for activities like dumping excavated sand within a range of 5-10 cm outside the nest, these ants learn and utilize the visual landmark panorama around the nest.


Assuntos
Formigas , Animais , Formigas/fisiologia , Austrália , Aprendizagem , Caminhada , Comportamento de Nidação , Clima Desértico , Comportamento de Retorno ao Território Vital , Sinais (Psicologia) , Navegação Espacial
4.
Biol Lett ; 20(2): 20230330, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38351747

RESUMO

Adaptive evolution relies on both heritable variation and selection. Variation is the raw material upon which selection acts, so any mechanism that limits or prevents the generation of heritable variation reduces the power of selection to lead to adaptation. Such limitations are termed evolutionary constraints. While it is widely accepted that constraints play an important role in shaping evolutionary outcomes, their relative importance, as opposed to adaptation, in determining evolutionary outcomes remains a subject of debate. Evolutionary constraints are often evoked as the reason behind the persistence of inaccurate mimicry. Here, we compared the variation and accuracy of body-shape mimicry in ant-mimicking spiders with that of ant-mimicking insects, predicting greater constraints, and hence inaccuracy, in spiders mimicking ants, due to their evolutionary distance from the ant model. We found high inter-species variation in mimetic accuracy, but dorsally, no overall difference in mimetic accuracy between spider and insect mimics, which is inconsistent with a constraint causing inaccurate mimicry. Our study provides empirical evidence suggesting that imperfect mimicry in spiders and insects is predominantly shaped by adaptive processes rather than constraints or chance. Our findings contribute to our understanding of the mechanisms underlying evolutionary diversity and the processes that shape phenotypic outcomes.


Assuntos
Comportamento Predatório , Aranhas , Animais , Comportamento Predatório/fisiologia , Aranhas/fisiologia
5.
Proc Biol Sci ; 288(1952): 20210815, 2021 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-34102888

RESUMO

Many animals mimic dangerous or undesirable prey as a defence from predators. We would expect predators to reliably avoid animals that closely resemble dangerous prey, yet imperfect mimics are common across a wide taxonomic range. There have been many hypotheses suggested to explain imperfect mimicry, but comparative tests across multiple mimicry systems are needed to determine which are applicable, and which-if any-represent general principles governing imperfect mimicry. We tested four hypotheses on Australian ant mimics and found support for only one of them: the information limitation hypothesis. A predator with incomplete information will be unable to discriminate some poor mimics from their models. We further present a simple model to show that predators are likely to operate with incomplete information because they forage and make decisions while they are learning, so might never learn to properly discriminate poor mimics from their models. We found no evidence that one accurate mimetic trait can compensate for, or constrain, another, or that rapid movement reduces selection pressure for good mimicry. We argue that information limitation may be a general principle behind imperfect mimicry of complex traits, while interactions between components of mimicry are unlikely to provide a general explanation for imperfect mimicry.


Assuntos
Mimetismo Biológico , Animais , Austrália , Evolução Biológica , Aprendizagem , Modelos Biológicos , Fenótipo , Comportamento Predatório
6.
Breast J ; 25(2): 296-300, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30706574

RESUMO

A radiation dose survey has been undertaken involving 256 patients to investigate the dosimetric impact of breast tomosynthesis screening by employing different breast densities estimated by the Dance model, 50-50 breast model, and patient-specific density software: Volpara. Mean glandular dose (MGD) based on the Dance model provided the most realistic dose estimate with an average difference of -3.3 ± 4.8% from the patient-specific estimation. Average differences of -8.2 ± 6.5% and -7.3 ± 4.7% were observed for the 50-50 breast model and console MGD, respectively. We conclude that the Dance model should be used for dose calculations in radiation dose surveys and establishing diagnostic reference levels (DRL).


Assuntos
Densidade da Mama , Mamografia/métodos , Doses de Radiação , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Modelos Biológicos , Radiometria/métodos
7.
Biol Lett ; 14(5)2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29720447

RESUMO

Clearwing moths are known for their physical resemblance to hymenopterans, but the extent of their behavioural mimicry is unknown. We describe zigzag flights of sesiid bee mimics that are nearly indistinguishable from those of sympatric bees, whereas sesiid wasp mimics display faster, straighter flights more akin to those of wasps. In particular, the flight of the sesiids Heterosphecia pahangensis, Aschistophleps argentifasciata and Pyrophleps cruentata resembles both Tetragonilla collina and T. atripes stingless bees and, to a lesser extent, dwarf honeybees Apis andreniformis, whereas the sesiid Pyrophleps sp. resembles Tachysphex sp. wasps. These findings represent the first experimental evidence for behavioural mimicry in clearwing moths.


Assuntos
Mimetismo Biológico , Voo Animal/fisiologia , Mariposas/fisiologia , Animais , Comportamento Animal/fisiologia , Gravação em Vídeo
8.
Surg Endosc ; 30(7): 2834-9, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26490772

RESUMO

BACKGROUND: Conventional laparoscopic instruments used for retraction may cause trauma at the retraction site. Alternative retraction/lifting especially of heavy solid organs such as the liver may be obtained by other means. The present study was designed to explore the use of C3-muco-adhesive polymers (C3-MAPs), which exhibit strong binding to the liver shortly after application to the organ and which retain strong adhesion for sufficient time, to enable sustained retraction during laparoscopic operations. METHODS AND MATERIALS: C3-muco-adhesive polymers were produced specifically for the study. In an ex vivo experimental set-up, discs of C3-MAPs were placed on the surface of porcine livers for adhesion and retraction studies involving objective measurements by tensiometry. RESULTS: Experiments were carried out on 14 porcine livers. The force required to detach the C3-MAPs from the liver exceeded 2.0 N 30 s after application. The adhesion force by C3-MAPs files was sufficient to enable sustained retraction force necessary for exposure of the gall bladder, which was achieved by a mean retraction force of 4.85 N (SD = 0.63). This was sustained for a mean of 130 min (range 17.0-240.0). In the adhesion studies, the forces at 30 s required to detach the polymer discs from the liver exceeded 20 N (upper limit of the load cells of the Instron). The duration of the adhesion enabled sustained optimal gall bladder exposure for periods ranging from 17 to 240 min, with a mean of 130 ± 91 min. CONCLUSIONS: The results of the present study demonstrate that the adhesion and retraction properties of the engineered C3-MAP films are sufficient to enable complete exposure of the gall bladder for a period exceeding 1 h, confirming their potential for atraumatic retraction in laparoscopic and other minimal-access surgical approaches.


Assuntos
Acrilatos/uso terapêutico , Derivados da Hipromelose/uso terapêutico , Laparoscopia/métodos , Fígado , Poloxâmero/uso terapêutico , Adesivos Teciduais/uso terapêutico , Abdome , Animais , Fenômenos Mecânicos , Suínos
9.
J Appl Clin Med Phys ; 16(4): 244­253, 2015 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-26219009

RESUMO

This study investigated the clinical performance of a novel solid-state diagnostic dosimeter, the RaySafe Xi transparent detector, by comparing its performance to a reference-class ionization chamber. Firstly a comparison of dosimeter response "free-in-air" with standard beam qualities was made, followed by an investigation into its relative transparency in an X-ray field and angular sensitivity dependence. The second part of the study looked at the overall performance of the transparent detector under scatter conditions with a number of beam qualities, including standard beam and those hardened by copper (Cu) filtration of thickness up to 0.9 mm, as would be encountered in the equipment testing of fluoroscopy systems. Overall, the transparent detector has demonstrated equivalent measurement properties to the ionization chamber under standard conditions and provided similar X-ray attenuation as reflected by the nearly identical radiographic parameters selected for both dosimeters by the automatic dose rate control (ADRC) system. Yet, it also possessed an asymmetric angular response which respectively under- and overestimated the dose contribution from the rear and lateral directions by the same amount of 50%. The transparent detector provided comparable dose reading of ± 3% to the ionization chamber with standard beam qualities and backscatter radiation present. These results were in good agreement with those of free-in-air measurement, indicating that the angular under- and overresponse might potentially compensate one another for accurate measurement. However, for identical Cu filtered beam qualities and setups, the transparent detector on average overresponded by 5.4% across the useful tube voltage range. In conclusion, the transparent detector, with its novel design, is essentially equivalent, within a 5% tolerance, to an ionization chamber, except in situations where beams hardened with Cu filtration are used with backscatter radiation present requiring larger uncertainty error estimations.


Assuntos
Fótons , Garantia da Qualidade dos Cuidados de Saúde , Radiometria/instrumentação , Radiometria/métodos , Desenho de Equipamento , Humanos , Doses de Radiação , Espalhamento de Radiação , Raios X
10.
Surg Endosc ; 28(4): 1277-83, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24366187

RESUMO

BACKGROUND: Despite the importance of efficient grasping during laparoscopic surgery, the published literature on jaw features, e.g., fenestrations and surface profiling on grasping efficiency defined as resistance to slip without inflicting trauma, is limited. METHODS: Various surface geometries of the jaws were tested with respect to (i) inclusion of fenestrations; (ii) surface contact to fenestration area ratio, and (iii) surface profiling of the jaws. Various loads were applied to the tissue which was subsequently pulled at a constant rate until free from the jaws. The maximal force necessary to pull the tissue free was recorded. The jaws were designed for use in parallel-occlusion graspers to avoid the well documented high pinch forces encountered with pivoted occlusion. RESULTS: At all applied forces the force needed to pull tissue from any fenestration design was significantly higher than the force necessary to pull tissue from non-fenestrated jaws (p < 0.05) with no significant differences between the three fenestration designs. The ratio of surface contact to fenestration area must exceed 1:0.4 to achieve a significant increase in the tissue retention. All the profiles studied were made using a single fenestration and with a surface contact to fenestration area ratio of 1:0.8. All such profile designs studied performed significantly better than the control (p < 0.005). The ratio of the mean retraction to applied force across all load conditions tested were 1.23:1.0 and 1.7:1.0 for the waved and toothed profile respectively, with standard deviations for the corresponding retraction force of ±0.45 and ±0.38 respectively. CONCLUSIONS: The retention efficiency of laparoscopic graspers is improved by fenestration which must, however, exceed a certain ratio (>1.0:0.4). Likewise surface profiling of the jaws enhances retention efficiency and its design (tooth, waved, mixed) directly influences the amount of pressure needed to retain tissue.


Assuntos
Força da Mão , Laparoscópios , Laparoscopia/instrumentação , Desenho de Equipamento , Humanos , Propriedades de Superfície
11.
Heart Vessels ; 29(2): 199-205, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23615833

RESUMO

Dual-axis rotational coronary angiography (DARCA) is a new imaging technique involving three-dimensional rotation of the gantry around the patient with simultaneous left to right and craniocaudal movements. This allows complete imaging of the left or right coronary tree with a single acquisition run. Previous small studies have indicated that DARCA is associated with reduced radiation dose and contrast use in comparison with standard coronary angiography (SCA). We conducted a registry of unselected patients undergoing DARCA or SCA. DARCA was used in 107 patients and SCA in 105 patients. Mean number of acquisition runs was 2.6 for DARCA and 6.9 for SCA (P < 0.0001). Mean radiation dose (dose-area product, DAP) was 30.4 Gy cm(2) for SCA and 15.9 Gy cm(2) for DARCA (P < 0.0001). Mean contrast volume was 41.7 ml for SCA and 25.7 ml for DARCA (P < 0.0001). Case time for DARCA in the first half of the study was 20.8 ± 1.4 min compared with 15.2 ± 2.0 min in the second half of the study (P = 0.0015), suggesting a learning curve. In the DARCA group, 64 % of patients required only two acquisition runs for complete and satisfactory imaging. There were no adverse effects resulting from DARCA. Two cases are presented to illustrate the diagnostic ability of DARCA. DARCA was associated with a 48 % reduction in radiation dose and 36 % reduction in contrast volume in comparison with SCA, with comparable diagnostic ability.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Meios de Contraste , Doença da Artéria Coronariana/terapia , Feminino , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Sistema de Registros , Adulto Jovem
12.
J Med Imaging Radiat Oncol ; 68(4): 385-392, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38687690

RESUMO

INTRODUCTION: While there are many papers on maternal and foetal radiation doses from computed tomography pulmonary angiography (CTPA) and ventilation/perfusion (V/Q) lung scanning examinations for diagnosing pulmonary embolism in pregnant patients, few have used clinical data to examine the patient lifetime attributable risk (LAR) of different cancer types. This paper aims to estimate the cancer risk from maternal radiation doses from CTPA and V/Q examinations and associated foetal doses. METHODS: Dosimetric data were determined for 267 pregnant patients who received CTPA and/or V/Q examinations over 8 years. Organ and foetal doses were determined using software allowing patient size variations for CTPA and using two different activity-to-organ dose conversion methods for V/Q scans. The LAR of cancer incidence was estimated using International Commission on Radiological Protection (ICRP) modelling including estimates of detriment. RESULTS: Estimated total cancer incidence was 23 and 22 cases per 100,000 for CTPA and V/Q examinations, respectively, with detriment estimates of 18 and 20 cases. Cancer incidence was evenly divided between lung and breast cancer for CTPA with lung cancer being 80% of all cancer for V/Q. The median foetal doses were 0.03 mSv for CTPA and 0.29 mSv for V/Q. Significant differences in estimated foetal dose for V/Q scans were obtained by the two different methods used. The differences in dose between the modes of CTPA scan acquisition highlight the importance of optimisation. CONCLUSION: Maternal cancer incidence and detriment were remarkably similar for each examination. Optimisation of examinations is critical for low-dose outcomes, particularly for CTPA examination.


Assuntos
Angiografia por Tomografia Computadorizada , Neoplasias Induzidas por Radiação , Embolia Pulmonar , Doses de Radiação , Humanos , Embolia Pulmonar/diagnóstico por imagem , Feminino , Gravidez , Angiografia por Tomografia Computadorizada/métodos , Neoplasias Induzidas por Radiação/diagnóstico por imagem , Adulto , Cintilografia de Ventilação/Perfusão , Incidência , Medição de Risco , Feto/diagnóstico por imagem , Feto/efeitos da radiação , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem
13.
BMC Health Serv Res ; 13: 190, 2013 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-23705824

RESUMO

BACKGROUND: Goal setting is considered 'best practice' in stroke rehabilitation; however, there is no consensus regarding the key components of goal setting interventions or how they should be optimally delivered in practice. We developed a theory-based goal setting and action planning framework (G-AP) to guide goal setting practice. G-AP has 4 stages: goal negotiation, goal setting, action planning & coping planning and appraisal & feedback. All stages are recorded in a patient-held record. In this study we examined the implementation, acceptability and perceived benefits of G-AP in one community rehabilitation team with people recovering from stroke. METHODS: G-AP was implemented for 6 months with 23 stroke patients. In-depth interviews with 8 patients and 8 health professionals were analysed thematically to investigate views of its implementation, acceptability and perceived benefits. Case notes of interviewed patients were analysed descriptively to assess the fidelity of G-AP implementation. RESULTS: G-AP was mostly implemented according to protocol with deviations noted at the planning and appraisal and feedback stages. Each stage was felt to make a useful contribution to the overall process; however, in practice, goal negotiation and goal setting merged into one stage and the appraisal and feedback stage included an explicit decision making component. Only two issues were raised regarding G-APs acceptability: (i) health professionals were concerned about the impact of goal non-attainment on patient's well-being (patients did not share their concerns), and (ii) some patients and health professionals found the patient-held record unhelpful. G-AP was felt to have a positive impact on patient goal attainment and professional goal setting practice. Collaborative partnerships between health professionals and patients were apparent throughout the process. CONCLUSIONS: G-AP has been perceived as both beneficial and broadly acceptable in one community rehabilitation team; however, implementation of novel aspects of the framework was inconsistent. The regulatory function of goal non-attainment and the importance of creating flexible partnerships with patients have been highlighted. Further development of the G-AP framework, training package and patient held record is required to address the specific issues highlighted by this process evaluation. Further evaluation of G-AP is required across diverse community rehabilitation settings.


Assuntos
Serviços de Saúde Comunitária/métodos , Planejamento de Assistência ao Paciente , Reabilitação do Acidente Vascular Cerebral , Adulto , Idoso , Serviços de Saúde Comunitária/organização & administração , Serviços de Saúde Comunitária/normas , Feminino , Humanos , Entrevistas como Assunto , Masculino , Pessoa de Meia-Idade , Terapia Ocupacional/métodos , Terapia Ocupacional/normas , Planejamento de Assistência ao Paciente/organização & administração , Planejamento de Assistência ao Paciente/normas , Especialidade de Fisioterapia/métodos , Especialidade de Fisioterapia/normas , Relações Profissional-Paciente , Avaliação de Programas e Projetos de Saúde
14.
PeerJ ; 11: e16413, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38047024

RESUMO

The current consensus is that sexual selection is responsible for the rapid and diverse evolution of genitalia, with several mutually exclusive mechanisms under debate, including non-antagonistic, antagonistic and stabilizing mechanisms. We used the orb-web spider, Argiope lobata (Araneidae), as a study model to quantify the allometric relationship between body size and genitalia, and to test for any impact of genital structures on male mating success or outcome in terms of copulation duration, leg loss or cannibalism. Our data do not support the 'one-size-fits-all' hypothesis that predicts a negative allometric slope between genitalia and body size. Importantly, we measured both male and female genitalia, and there was no sex specific pattern in allometric slopes. Unexpectedly, we found no predictor for reproductive success as indicated by copulation duration, cannibalism, and leg loss.


Assuntos
Aranhas , Animais , Masculino , Feminino , Genitália , Copulação , Genitália Feminina , Tamanho Corporal
15.
Australas Phys Eng Sci Med ; 35(1): 41-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22143903

RESUMO

A contrast-detail experiment was simulated using Monte Carlo methods, to test the hypothesis that quantum limitations lead to an optimum minimum focal spot size below which no further improvement in image quality may be obtained. The simulation included a variable X-ray tube focal spot size, patient equivalent water phantom, X-ray couch, automatic exposure control, anti-scatter grid and indirect digital radiography detector. A number of simplifications were necessary in order to limit the calculation time to 8 days per image. Four images were produced for each focal spot size and these were scored by eight experienced observers. The contrast-detail curves were found to improve monotonically as focal spot size was reduced, with the best images produced by a point source. This contradicts the hypothesis of quantum limitation of focal spot size. We conclude that further work is required on the optimization of focal spot size. To assist with this, a new definition of system detective quantum efficiency is suggested, that includes the focal spot modulation transfer function, but does not include scattered radiation from the patient.


Assuntos
Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Algoritmos , Simulação por Computador , Humanos , Fótons , Doses de Radiação , Espalhamento de Radiação , Ecrans Intensificadores para Raios X
16.
PeerJ ; 10: e12839, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35341059

RESUMO

Many ecological interactions of spiders with their potential prey and predators are affected by the visibility of their bodies and silk, especially in habitats with lower structural complexity that expose spiders. For instance, the surface of tree trunks harbours relatively limited structures to hide in and may expose residents to visual detection by prey and predators. Here we provide the first detailed description of the novel retreat building strategy of the tree trunk jumping spider Arasia mullion. Using fields surveys, we monitored and measured over 115 spiders and 554 silk retreats. These spiders build silk retreats on the exposed surface of tree trunks, where they remain as sedentary permanent residents. Furthermore, the spiders decorate the silk retreats with bark debris that they collect from the immediate surrounding. We discuss the role of silk decoration in the unusual sedentary behaviour of these spiders and the potential mechanisms that allow A. mullion to engineer their niche in a challenging habitat.


Assuntos
Seda , Aranhas , Animais , Seda/química , Comportamento Predatório , Ecossistema , Comportamento Animal
17.
Sci Data ; 9(1): 265, 2022 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-35654905

RESUMO

Trait databases have become important resources for large-scale comparative studies in ecology and evolution. Here we introduce the AnimalTraits database, a curated database of body mass, metabolic rate and brain size, in standardised units, for terrestrial animals. The database has broad taxonomic breadth, including tetrapods, arthropods, molluscs and annelids from almost 2000 species and 1000 genera. All data recorded in the database are sourced from their original empirical publication, and the original metrics and measurements are included with each record. This allows for subsequent data transformations as required. We have included rich metadata to allow users to filter the dataset. The additional R scripts we provide will assist researchers with aggregating standardised observations into species-level trait values. Our goals are to provide this resource without restrictions, to keep the AnimalTraits database current, and to grow the number of relevant traits in the future.


Assuntos
Metabolismo Basal , Peso Corporal , Encéfalo , Bases de Dados Factuais , Animais , Ecologia , Tamanho do Órgão , Fenótipo
18.
Australas Phys Eng Sci Med ; 42(1): 193-199, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30707352

RESUMO

Further assessment of suspicious lesions found during asymptomatic breast cancer screening is critical and involves mammographic follow up with biopsy. The X-ray procedure is complex and variable in nature and until now there is little information on the radiation dose to the breast or associated risks. A survey of radiation doses from a Siemens MammoTest prone biopsy with the support of a Sectra L30 AIR mammographic unit for workup and post clip images has been completed. Procedure details and outcomes, including radiographic and patient related variables have been collected and analysed using standard dosimetric formulation. The partial irradiation of the breast in biopsy and magnification views was considered. The average mean glandular breast dose was 5.13 mGy, comprising of 3.52 mGy from the biopsy procedure and 1.61 mGy from the workup and post clip images, with an average of 8.4 biopsy images and 5.8 workup and post clip images. The risk from these dose levels are dependent on the age of the woman, however are not considered high for a symptomatic X-ray procedure.


Assuntos
Mama/patologia , Mama/efeitos da radiação , Mamografia , Biópsia , Relação Dose-Resposta à Radiação , Feminino , Humanos , Tamanho do Órgão/efeitos da radiação , Radiometria
20.
Australas Phys Eng Sci Med ; 40(1): 153-158, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27832459

RESUMO

The use of parameters water equivalent diameter (D W ) and size-specific dose estimate (SSDE) are becoming increasingly established as a recognised method to relate patient dose from a CT examination to the dose indicator volume CT dose index (CTDIVOL). However, the role of the attenuation due to the patient table in these estimations requires careful consideration and is the subject of this study. The aim of this study is to investigate the impact of a minimal part of the patient table when calculating the D W and SSDE. We investigated 164 patients who had undergone CT examinations for the pelvis, abdomen, thorax and head. We subsequently calculated D W and SSDE using two methods: one using a small circular region of interest (ROI) including a minimal part of the patient table and the other using a ROI fitted to the patient border alone. The results showed that the water equivalent diameter calculated with the table included in the ROI (D W,t ) is greater, compared to that without the consideration of the patient table (D W,nt ), by 1.5-6.2% depending on the anatomy being imaged. On the other hand, the SSDE calculated with inclusion of the patient table (SSDEt) is smaller than otherwise (SSDEnt) by 1.0-5.5% again depending on the anatomy being imaged. The effect of the patient table on D W and SSDE in the thorax CT examination was statistically significant, but its effect on D W and SSDE in the other examinations of head, pelvis and abdomen was relatively small and not statistically significant.


Assuntos
Doses de Radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Especificidade de Órgãos , Tomografia Computadorizada por Raios X , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA