Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Ear Hear ; 44(3): 566-571, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36534657

RESUMO

OBJECTIVES: To determine rates of hearing preservation and performance in patients who met candidacy for electroacoustic stimulation (EAS) and were implanted with a slim modiolar electrode (CI532 or CI632). DESIGN: Adult patients meeting Food and Drug Administration criteria for electroacoustic stimulation (preoperative low-frequency pure-tone average [LFPTA] less than 60 dB at 125, 250, and 500 Hz and monosyllabic word scores between 10% and 60% in the ear to be implanted), who received a slim modiolar electrode were included. Main outcome measures included rates of hearing preservation, defined as a LFPTA ≤80 dB at 125, 250, and 500 Hz, as well as postoperative low-frequency pure-tone threshold shifts, consonant-Nucleus-Consonant (CNC) word scores and AzBio sentences in noise scores. RESULTS: Forty-six patients met inclusion criteria during a 4-year period. Mean (standard deviation) preoperative LFPTA was 34.5 (13.0) dB, and 71.7% had preserved hearing at initial activation. The mean LFPTA shift in patients who preserved hearing at initial activation was 19.7 (14.6) dB, compared with 62.6 (17.7) dB in patients who did not preserve hearing as per our definition. Perioperative steroid use was not different in patients with and without preserved hearing (X 2 (1, N = 46) = 0.19, p = .67, V = 0.06). One year after surgery, 57% of patients had a decline in LFPTA >80 dB and were no longer considered candidates for EAS, with 34.7% still retaining low-frequency thresholds ≤80 dB. CNC word scores at 1 year were 69.9% and 61.4% among individuals with and without preserved low-frequency hearing respectively, measured in their CI ear alone, in their regular listening condition of EAS or electric only ( t (32) = 1.13, p = 0.27, d = 0.39, 95% CI = -6.51, 22.86). Device use time did not differ between groups. Among adults with preserved residual hearing at 1 year (n = 16), 44% used EAS, although there was no significant difference in performance between EAS users and nonusers with preserved hearing. Loss of residual hearing over time did not result in a decline in speech perception performance. CONCLUSION: The present study demonstrated favorable early rates of hearing preservation with a slim modiolar array. Performance was not significantly different in individuals with and without preserved low-frequency acoustic hearing, independent of EAS use. Compared with reports of short electrode use, the loss of residual hearing in patients implanted with this array did not impact speech perception performance.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Cóclea/cirurgia , Audição/fisiologia , Audiometria de Tons Puros , Resultado do Tratamento , Estimulação Elétrica , Estudos Retrospectivos
2.
Ear Hear ; 36(2): e23-34, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25319401

RESUMO

OBJECTIVES: Pitch plasticity has been observed in Hybrid cochlear implant (CI) users. Does pitch plasticity also occur in bimodal CI users with traditional long-electrode CIs, and is pitch adaptation pattern associated with electrode discrimination or speech recognition performance? The goals of this study were to characterize pitch adaptation patterns in long-electrode CI users, to correlate these patterns with electrode discrimination and speech perception outcomes, and to analyze which subject factors are associated with the different patterns. DESIGN: Electric-to-acoustic pitch matches were obtained in 19 subjects over time from CI activation to at least 12 months after activation, and in a separate group of 18 subjects in a single visit after at least 24 months of CI experience. Audiometric thresholds, electrode discrimination performance, and speech perception scores were also measured. RESULTS: Subjects measured over time had pitch adaptation patterns that fit one of the following categories: (1) "Pitch-adapting," that is, the mismatch between perceived electrode pitch and the corresponding frequency-to-electrode allocations decreased; (2) "Pitch-dropping," that is, the pitches of multiple electrodes dropped and converged to a similar low-pitch; and (3) "Pitch-unchanging," that is, the electrode pitches did not change. Subjects measured after CI experience had a parallel set of adaptation patterns: (1) "Matched-pitch," that is, the electrode pitch was matched to the frequency allocation; (2) "Low-pitch," that is, the pitches of multiple electrodes were all around the lowest frequency allocation; and (3) "Nonmatched-pitch," that is, the pitch patterns were compressed relative to the frequency allocations and did not fit either the matched-pitch or low-pitch categories. Unlike Hybrid CI users which were mostly in the pitch-adapting or matched-pitch category, the majority of bimodal CI users were in the latter two categories, pitch-dropping/low-pitch or pitch-unchanging/nonmatched-pitch. Subjects with pitch-adapting or matched-pitch patterns tended to have better low-frequency thresholds than subjects in the latter categories. Changes in electrode discrimination over time were not associated with changes in pitch differences between electrodes. Reductions in speech perception scores over time showed a weak but nonsignificant association with dropping-pitch patterns. CONCLUSIONS: Bimodal CI users with more residual hearing may have somewhat greater similarity to Hybrid CI users and be more likely to adapt pitch perception to reduce mismatch with the frequencies allocated to the electrodes and the acoustic hearing. In contrast, bimodal CI users with less residual hearing exhibit either no adaptation, or surprisingly, a third pattern in which the pitches of the basal electrodes drop to match the frequency range allocated to the most apical electrode. The lack of association of electrode discrimination changes with pitch changes suggests that electrode discrimination does not depend on perceived pitch differences between electrodes, but rather on some other characteristics such as timbre. In contrast, speech perception may depend more on pitch perception and the ability to distinguish pitch between electrodes, especially since during multielectrode stimulation, cues such as timbre may be less useful for discrimination.


Assuntos
Adaptação Fisiológica , Implantes Cocleares , Surdez/reabilitação , Percepção da Altura Sonora , Percepção da Fala , Idoso , Implante Coclear , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
3.
Neurosurg Focus ; 36(1 Suppl): 1, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24380530

RESUMO

A petroclival meningioma represents a challenging tumor to resect in the cerebellopontine angle and ventral to the brain stem. Multiple cranial nerves and blood vessels may be intimately involved with the tumor. A partial labyrinthectomy presigmoid transpetrosal approach can facilitate resection while preserving hearing. This approach allows for a direct line of sight along the petrous bone while sealing the canals can preserve hearing. In this video operative manuscript, we demonstrate a step-by-step illustration of a partial labyrinthectomy presigmoid transpetrosal resection of a petroclival meningioma. This approach affords the best chance of hearing preservation and an opportunity for maximum tumor resection. The video can be found here: http://youtu.be/29I4KEXz1vY .


Assuntos
Ângulo Cerebelopontino/cirurgia , Craniotomia , Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Neoplasias da Base do Crânio/cirurgia , Idoso , Craniotomia/métodos , Feminino , Humanos , Neoplasias Meníngeas/diagnóstico , Meningioma/diagnóstico , Neoplasias da Base do Crânio/diagnóstico
4.
Otol Neurotol ; 45(2): 121-127, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38082466

RESUMO

OBJECTIVE: To assess the safety of cochlear implants (CIs) in children under 9 months of age to better understand expected postoperative complication rates, and to provide a preliminary look at efficacy. STUDY DESIGN: Single-center retrospective review. SETTING: Tertiary referral center. PATIENTS: Children 5 to 8 months of age who received a CI between 2011 and 2021. INTERVENTIONS: Therapeutic-CI. MAIN OUTCOME MEASURES: The primary outcome was 6-month postoperative complication rate. Secondary outcomes included length of stay, device explantation/reimplantation, rehabilitation supports, and hearing and language outcomes. Complications of children implanted under than 9 months of age was compared with a cohort of children implanted 9 to 18 months of age between the years 2011 and 2016 using a chi-squared test ( p < 0.05). RESULTS: One hundred six children under 9 months of age were implanted (204 CIs) at a mean age of 6.6 months (range: 5-8). Postoperative complications occurred in 28 patients (26%) and were often minor. There were no mortalities. There was no statistically significant difference in complications, including reimplantation rates, between patients implanted under 9 months of age and those implanted 9 to 18 months of age. Speech discrimination outcomes were excellent, and mean spoken language outcomes were near normative for typically developing children. CONCLUSIONS: Cochlear implantation can be a safe and effective treatment option for children 5 to 8 months of age. Early hearing screening and referral for infants to receive appropriate intervention will continue to play a critical role in optimizing speech and language outcomes.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Percepção da Fala , Criança , Lactente , Humanos , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Audição , Fala , Resultado do Tratamento , Complicações Pós-Operatórias/cirurgia , Surdez/cirurgia
5.
Otol Neurotol Open ; 4(3): e060, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39328867

RESUMO

Objective: To better characterize the cochlear apex in relation to surgically relevant landmarks to guide surgeons and improve procedural success of apical electrode placement. Study Design: Retrospective image analysis. Setting: Tertiary referral center. Patients: Cochlear implant recipients with available preoperative computed tomography (CT) imaging. Intervention: None. Main Outcome Measure: Cochlear dimensions and cochlear apex distance measures to surgically relevant middle ear landmarks and critical structures. Results: Eighty-two temporal bone CT scans were analyzed utilizing multiplanar reformats. The average lateral width of promontory bone over the cochlear apex was 1.2 mm (standard deviation [SD], 0.3). The anteroposterior distance from the round window (avg, 4.2 mm; SD, 0.5), oval window (avg, 3.3 mm; SD, 0.3), cochleariform process (avg, 2.3; SD, 0.5), and superior-inferior distance from the cochleariform process (avg, -0.9; SD, 0.8) to the cochlear apex were measured. The relationship of the cochlear apex to critical structures was highly variable.A newly developed stapes vector was created and found to mark the posterior/superior boundary of the apex in 94% of patients. When a vector parallel to the stapes vector was drawn through the round window, it marked the anterior/inferior boundary of the cochlear apex in 89% of patients. Conclusions: This study assists in characterizing cochlear apex anatomy and its relation to surrounding structures as a means of improving procedural accuracy and reducing trauma during apical cochleostomy. Understanding both distance relationships and expected boundaries of the apex could help to inform future surgical approaches.

6.
Otol Neurotol ; 45(9): e630-e638, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39190800

RESUMO

OBJECTIVE: To characterize transimpedance matrix (TIM) heatmap patterns in patients at risk of labyrinthine abnormality to better understand accuracy and possible TIM limitations. STUDY DESIGN: Retrospective review of TIM patterns, preoperative, and postoperative imaging. SETTING: Tertiary referral center. PATIENTS: Patients undergoing cochlear implantation with risk of labyrinthine abnormality. INTERVENTION: None. RESULTS: Seventy-seven patients were evaluated. Twenty-five percent (n = 19) of patients had a TIM pattern variant identified. These variants were separated into 10 novel categories. Overall, 9% (n = 6) of electrodes were malpositioned on intraoperative x-ray, of which 50% (n = 3) were underinserted, 17% (n = 1) were overinserted, 17% (n = 1) had a tip foldover, and 17% (n = 1) had a coiled electrode. The number of patients with a variant TIM pattern and normal x-ray was 18% (n = 14), and the number of patients with normal TIM pattern and malposition noted on x-ray was 3% (n = 2; both were electrode underinsertions that were recognized due to open circuits and surgical visualization).A newly defined skip heat pattern was identified in patients with IP2/Mondini malformation and interscalar septum width <0.5 mm at the cochlear pars ascendens of the basal turn. CONCLUSIONS: This study defines novel patterns for TIM heatmap characterization to facilitate collaborative and comparative research moving forward. In doing so, it highlights a new pattern termed skip heat, which corresponds with a deficient interscalar septum of the cochlea pars ascendens of the basal turn in patients with IP2 malformation. Overall, the data assist the surgeon in better understanding the implications and limitations of TIM patterns within groups of patients with risk of labyrinthine abnormalities.


Assuntos
Implante Coclear , Implantes Cocleares , Impedância Elétrica , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Feminino , Masculino , Pré-Escolar , Criança , Lactente , Orelha Interna/anormalidades , Orelha Interna/diagnóstico por imagem , Adolescente , Adulto , Pessoa de Meia-Idade
7.
Otol Neurotol ; 45(9): 1016-1022, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39264919

RESUMO

OBJECTIVE: To better understand cochlear implant (CI) performance after reimplantation with a different device manufacturer. STUDY DESIGN: Multisite retrospective review. SETTING: Tertiary referral centers. PATIENTS: Patients older than 4 years who received a CI and subsequently underwent CI reimplantation with a different manufacturer over a 20-year period. INTERVENTION: Reimplantation. MAIN OUTCOME MEASURE: The primary outcome was difference in the best CNC score obtained with the primary CI, compared with the most recent CNC score obtained after reimplantation. RESULTS: Twenty-nine patients met the criteria at three centers. The best average CNC score achieved by adult patients after primary cochlear implantation was 46.2% (n = 16), measured an average of 14 months (range: 3-36 mo) postoperatively. When looking at the most recent CNC score of adult patients before undergoing reimplantation, the average CNC score dropped to 19.2% (n = 17). After reimplantation, the average 3- to 6-month CNC score was 48.3% (n = 12), with most recent average CNC score being 44.4% (n = 17) measured an average of 19 months (range: 3-46 mo) postoperatively. There was no statistically significant difference (p = 0.321; t11 = 0.48) identified in performance between the best CNC score achieved by adult patients after primary cochlear implantation, and the most recent score achieved after reimplantation (n = 12). Analysis of prerevision and postrevision speech performance was not possible in pediatric patients (<18 yr old) because of differences in tests administered. CONCLUSION: Patients undergoing reimplantation with a different manufacturer achieved CNC score performance comparable to their best performance with their original device.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Masculino , Adulto , Feminino , Pessoa de Meia-Idade , Idoso , Criança , Adolescente , Resultado do Tratamento , Pré-Escolar , Adulto Jovem , Percepção da Fala/fisiologia , Reoperação/estatística & dados numéricos , Reoperação/métodos , Reimplante/métodos
8.
Otolaryngol Head Neck Surg ; 168(5): 1164-1169, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36939482

RESUMO

OBJECTIVE: To assess a series of patients receiving teprotumumab therapy and objectively quantify the rates of otologic adverse events. STUDY DESIGN: A prospective cohort study of adult patients receiving teprotumumab between May 2020 and January 2022. SETTING: Tertiary referral center. METHODS: Prior to treatment initiation, an ototoxicity-specific audiometric battery was completed, which included conventional audiometry (frequencies 250-8000 Hz), ultrahigh-frequency audiometry (9000-20,000 Hz), tympanometry, speech discrimination scores, and distortion product otoacoustic emissions (DPOAEs). Testing was then repeated after treatment completion. RESULTS: In total, 35 patients were recruited, with a median (range) age of 48.5 years (21-74), and 8 (22.8%) were male. The most common subjective symptom reported was a hearing decline (25.7%), followed by aural fullness (17.1%) and tinnitus (14.3%). Fourteen patients had both pre- and posttreatment audiometric data. Among them, 3 patients (21.4%) were found to have changes in standard frequency audiometry, and 10 (71.4%) had changes in high-frequency audiometry, with 2 patients having changes in both. Less than half (n = 5) of the 11 patients with changes in standard or high-frequency pure tone hearing noted subjective hearing decline. Changes in DPOAE were noted in 4 patients out of 13 (30.7%). Two patients discontinued treatment due to hearing decline. Finally, 3 patients (8.6%) were diagnosed with patulous eustachian tube (PET) by an otolaryngologist, and another 3 patients are suspected to have PET based on symptom description during ophthalmologic follow-up. CONCLUSION: In our cohort, a high incidence of otologic symptoms was found to be associated with teprotumumab usage. Subjective hearing decline, changes in ultrahigh-frequency hearing as well as eustachian tube dysfunction may be encountered and suggest the potential ototoxicity of teprotumumab.


Assuntos
Emissões Otoacústicas Espontâneas , Ototoxicidade , Adulto , Humanos , Masculino , Adulto Jovem , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Prospectivos , Limiar Auditivo , Audiometria de Tons Puros
9.
Cochlear Implants Int ; 24(2): 87-94, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36411064

RESUMO

OBJECTIVE: Evaluate rates of Advanced Bionics Ultra 3D/Ultra cochlear implant failure in the setting of a worldwide device recall and report surgical and auditory outcomes after revision. METHODS: Retrospective chart review was performed for adult and pediatric patients implanted with at risk devices at our center from 2016 to 2020. Device failure rates, surgical, and auditory outcomes were recorded and analyzed. RESULTS: Of 113 at-risk devices, 20 devices (17.7%) in 18 patients (two bilaterally implanted) were identified as failures. All devices were with mid-scala electrodes. Eleven patients (61.1%) were children and 7 (38.9%) adults. Twelve patients were found to have failing devices after reporting subjective performance decline; the remainder were prompted by manufacturer notification. All were revised, with the majority (83.3%) choosing the same manufacturer. All had uncomplicated original and revision insertions. Among adults, average word scores on the revised side were stable pre- to post-revision (P = 0.95). DISCUSSION: Patients with device failure due to this field action performed well after revision implantation. Patients with bilateral at-risk devices but evidence of unilateral failure may elect to undergo simultaneous empiric revision of the contralateral device. Three patients who elected to change device manufacturers on revision have variable results that require further investigation. CONCLUSIONS: Patients requiring revision for a device field action overall perform well. At-risk devices continue to require monitoring as a growing number are likely to fail over time.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Criança , Humanos , Implantes Cocleares/efeitos adversos , Implante Coclear/efeitos adversos , Estudos Retrospectivos , Reoperação , Falha de Equipamento , Falha de Prótese
10.
Cochlear Implants Int ; 24(5): 268-272, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36988037

RESUMO

OBJECTIVES: Immune-checkpoint inhibitors (ICI) are being utilized with increasing frequency and may be linked to neurologic and audiovestibular toxicities. This report aimed to describe a case of ICI-induced sensorineural hearing loss ultimately requiring bilateral cochlear implantation. METHODS: A 42-year-old female with stage IV metastatic melanoma of the perianal skin was treated with ipilimumab (blocker of cytotoxic T-lymphocyte associated protein 4 [CTLA-4]) and nivolumab (anti-programmed cell death protein 1 [PD1]). After 21 weeks of therapy, she developed sudden vertigo and bilateral hearing loss. A full workup including MRI and lumbar puncture ruled out intracranial parenchymal metastases, leptomeningeal metastases, stroke and intracranial infection. ICI-associated aseptic meningoencephalitis was therefore diagnosed. The patient received systemic steroids as well as intratympanic steroids, which temporarily improved hearing, but eventually developed permanent, bilateral profound sensorineural hearing loss. RESULTS: The patient received bilateral cochlear implants and has demonstrated good performance one year after implantation. DISCUSSION: ICI are being increasingly used to treat a variety of advanced malignancies. This is the first report of bilateral cochlear implants in the context of profound hearing loss after an immunotherapy induced meningoencephalitis. CONCLUSION: ICI carries the risk of potential ototoxicity, including profound SNHL as depicted in our case. Cochlear implantation proved to be beneficial and may be considered in patients with ICI-related hearing loss.


Assuntos
Implante Coclear , Perda Auditiva Neurossensorial , Inibidores de Checkpoint Imunológico , Imunoterapia , Humanos , Feminino , Adulto , Imunoterapia/efeitos adversos , Inibidores de Checkpoint Imunológico/efeitos adversos , Perda Auditiva Neurossensorial/induzido quimicamente , Perda Auditiva Neurossensorial/cirurgia , Implantes Cocleares , Resultado do Tratamento
11.
Otol Neurotol ; 43(10): e1168-e1173, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36136609

RESUMO

OBJECTIVE: To describe the natural history of primary inner ear schwannomas over a long follow-up period. STUDY DESIGN: Retrospective case series. SETTING: Tertiary referral center. PATIENTS: Patients with primary inner ear schwannomas with serial audiometric and radiologic follow-up. MAIN OUTCOME MEASURES: Patterns of hearing loss, rate of hearing decline, presence of vestibular symptoms, and rate of tumor growth. RESULTS: A total of 12 patients with 13 tumors were identified. The mean duration of follow-up was 7 years. Forty-six percent of tumors were intracochlear, 15% were intravestibular, 23% were transmodiolar, and 15% were intravestibular-cochlear. Hearing loss was the most common presenting symptom, occurring in all patients. Among patients with serviceable hearing (American Academy of Otolaryngology-Head and Neck Surgery Class A or B) at the time of presentation, the average time to decline to a nonserviceable hearing level was 57.3 months (range, 21-117 mo). Hearing loss was sudden in 31% of patients, progressive in 61% and fluctuating in 8%. No patients had intractable vertigo; however, two required vestibular physiotherapy. On initial magnetic resonance imaging, the mean largest tumor dimension was 3.1 mm (standard deviation, 1.2 mm), and the mean largest dimension on most recent magnetic resonance imaging was 4.4 mm (standard deviation, 1.1 mm). Two tumors exhibited no growth over a follow-up of 11.3 and 2.8 years, respectively. Overall, the mean growth was 0.25 mm per year followed. Two patients underwent cochlear implantation with simultaneous tumor resection and had favorable outcomes. CONCLUSION: Long-term follow-up suggests a conservative approach, with possible hearing rehabilitation at the time of deterioration, is a safe management strategy for primary inner ear schwannomas.


Assuntos
Orelha Interna , Perda Auditiva , Neurilemoma , Neuroma Acústico , Humanos , Neuroma Acústico/complicações , Neuroma Acústico/cirurgia , Neuroma Acústico/patologia , Seguimentos , Estudos Retrospectivos , Orelha Interna/patologia , Neurilemoma/patologia , Perda Auditiva/etiologia , Perda Auditiva/cirurgia , Perda Auditiva/patologia , Resultado do Tratamento
12.
Otol Neurotol ; 43(6): 632-637, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35261375

RESUMO

OBJECTIVE: To evaluate outcomes of auditory implants in children with CHARGE syndrome and describe the evolution in management of hearing loss in this complex population. METHODS: A retrospective case review was performed at a tertiary referral center. Children with CHARGE syndrome who received either a cochlear implant (CI) or auditory brainstem implant (ABI) were included. Clinical records, demographic information, CHARGE features, neuroimaging, audiology, hearing rehabilitation interventions, operative notes, and outcomes were reviewed. RESULTS: Thirteen children with CHARGE syndrome underwent a total of 19 cochlear implants between 2008 and 2020. Among the congenitally deafened children (n = 9), six underwent bilateral implantation (five simultaneous and one sequential). Bilateral implantation was performed even in the presence of diminutive-appearing cochlear nerves. The average age of implantation was 1.1 years, and the mean device use time was 9.4 hours per day. Patients showed improvements in subjective family assessment related to hearing. In this group, two patients use oral communication, five use total communication, and two use sign language exclusively. Among the children with progressive hearing loss, the mean age of hearing deterioration was 4.4 years of age, and the device use time on average was 9.8 hours per day. The highest performer in the cohort was a child who lost hearing in their only hearing ear at age 4 and had normal cochleovestibular anatomy on that side. One child received an auditory brainstem implant at age two after deriving no benefit from a CI and can detect environmental sounds but is currently a nonuser. Over time, we noted that implantation occurred earlier in life and that practice has shifted toward bilateral implantation. CONCLUSIONS: Compared to a previous institutional cohort, children evaluated in this study were often implanted at a younger age and bilaterally with significantly improved outcomes. A CI evaluation should be considered in children with CHARGE syndrome to maximize sensory input and auditory ability.


Assuntos
Síndrome CHARGE , Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva , Síndrome CHARGE/complicações , Síndrome CHARGE/cirurgia , Criança , Pré-Escolar , Implante Coclear/métodos , Surdez/cirurgia , Perda Auditiva/cirurgia , Humanos , Lactente , Estudos Retrospectivos , Resultado do Tratamento
13.
J Neurol Surg B Skull Base ; 83(Suppl 2): e169-e172, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35832935

RESUMO

Soon after the World Health Organization declared the severe acute respiratory syndrome coronavirus 2 a global health emergency on January 30, 2020, New York City was plagued by the virus and its health system and economy pushed to their limits. The majority of the limited neurosurgical data in relation to COVID-19 is anecdotal and the higher theoretical risk of transmission of the virus among skull base aerosol generating (SBAG) cases has not been investigated or discussed in a neurosurgical population. We discuss a series of 13 patients who underwent 15 SBAG surgical procedures during the peak of COVID-19 in our hospital system and the protocols use perioperatively for their procedures. Our data support that with proper preoperative testing, a well-delineated surgical algorithm, and appropriate personal protective equipment, emergent/urgent cases can be done safely in hospitals that are currently experiencing high volumes of COVID-19 cases as we did in March to May of 2020.

14.
Otol Neurotol ; 43(9): 1027-1032, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36040040

RESUMO

OBJECTIVE: To evaluate the ability of the transimpedance matrix (TIM) measurement to detect cochlear implant electrode tip foldover by comparing results to a "gold standard," the intraoperative plain film radiograph. STUDY DESIGN: Retrospective case series. SETTING: Tertiary referral hospital. PATIENTS: One hundred three patients who underwent cochlear implantation between June 2020 and August 2021. INTERVENTIONS: Intraoperative electrophysiologic monitoring (electrode impedances, neural response telemetry, and TIM measurement) and modified Stenver's view plain film radiographs. MAIN OUTCOME MEASURES: Identification of tip foldover on both TIM and plain films. RESULTS: In total, 103 patients (117 ears) had both a TIM measurement and intraoperative X-ray available for review, including 68 adults and 35 children. One hundred patients (85%) received the Cochlear Slim Modiolar electrode. Tip foldovers were noted in three of 117 implants (2.5%). In all cases, TIM was able to detect the foldover, and the electrode arrays were reinserted with the patients still under anesthesia, with repeat X-ray demonstrating a normal configuration. Two other abnormal TIM patterns were identified. One was in a patient with an obstructed cochlea in whom only 10 electrodes could be inserted, the other was in a patient with a common cavity abnormality. One additional patient underwent electrode repositioning intraoperatively because of overinsertion. In this patient, the TIM appeared to be within normal limits, but the over-insertion was apparent on X-ray. Overall, the sensitivity and specificity of TIM measurements in detecting electrode tip foldover were both 100%. CONCLUSION: TIM measurements were able to accurately identify tip foldovers. More research is needed to define the adjunctive role of TIM as an intraoperative measure.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Criança , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Implante Coclear/métodos , Eletrodos Implantados , Humanos , Estudos Retrospectivos
15.
Otol Neurotol ; 43(9): 980-986, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36047686

RESUMO

OBJECTIVE: To review the current literature regarding cochlear implantation in patients with retrocochlear pathologies and extract speech perception scores between 6 months and 1 year after surgery. DATABASES REVIEWED: PubMed/MEDLINE, Embase and Cochrane CENTRAL via Ovid, CINAHL Complete via Ebsco, and Web of Science. METHODS: The review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Search strategies included keywords and subject headings to maximize retrieval and reflect cochlear implants and retrocochlear pathologies. Patients with previously resected vestibular schwannoma (VS) were excluded. RESULTS: There were 2,524 abstracts screened against inclusion criteria, and 53 studies were included, with individual data available for 171 adult patients. Pathologies included were either observed or irradiated VS (previously operated tumors were excluded) (n = 99, 57.9%), superficial siderosis (n = 39, 22.8%), neurosarcoidosis (n = 11, 6.4%), and previous central nervous system or skull base radiation (n = 22, 12.9%). Mean (standard deviation) postoperative consonant-nucleus-consonant (CNC) word scores were 45.4% (24.2) for observed VS, 44.4% (20.8) for irradiated VS, 43.6% (21.0) for superficial siderosis, 89.5% (3.0) for neurosarcoidosis, and 30.0% (30.2) in patients with previous central nervous system or skull base irradiation. Irradiated compared with observed VS had similar postoperative CNC word scores (effect size, 0.06; p = 0.71). Age, sex, maximal tumor dimension, and neurofibromatosis type 2 status did not significantly impact cochlear implant performance in patients with VS. Eighty-two percent of patients with reported device usage were daily users, and overall, 82% of cases benefitted from cochlear implantation. CONCLUSION: Cochlear implantation in patients with concomitant retrocochlear pathology generally results in improved speech discrimination scores sustained over time.


Assuntos
Implante Coclear , Implantes Cocleares , Neuroma Acústico , Sarcoidose , Siderose , Percepção da Fala , Adulto , Doenças do Sistema Nervoso Central , Implante Coclear/métodos , Humanos , Neuroma Acústico/complicações , Neuroma Acústico/cirurgia , Sarcoidose/complicações , Sarcoidose/cirurgia , Siderose/complicações , Resultado do Tratamento
16.
Otol Neurotol ; 43(10): e1085-e1089, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36190900

RESUMO

OBJECTIVE: To prospectively evaluate the frailty phenotype in a population of older adults and determine its association with 1) perioperative complications, 2) need for vestibular rehabilitation after surgery, and 3) early speech perception outcomes. STUDY DESIGN: Prospective cohort study. SETTING: Tertiary care hospital. PATIENTS: Adults older than 65 years undergoing cochlear implantation. INTERVENTIONS: The Fried Frailty Index was used to classify patients as frail, prefrail, or not frail based on five criteria: 1) gait speed, 2) grip strength, 3) unintentional weight loss, 4) weekly physical activity, and 5) self-reported exhaustion. MAIN OUTCOMES MEASURES: Rates of intraoperative and postoperative complications, postoperative falls, need for vestibular rehabilitation, and early speech perception outcomes. RESULTS: Forty-six patients were enrolled in this study. Five patients (10.8%) were categorized as frail and 10 (21.7%) as prefrail. The mean ages of frail, prefrail, and not frail patients were 80.9, 78.8, and 77.5, respectively. There were no intraoperative complications among all groups. Three patients required postoperative vestibular rehabilitation; all were not frail. One postoperative fall occurred in a nonfrail individual. Mean (standard deviation) device use times at 3 months in frail, prefrail, and not frail patients were 7.6 (3.5), 11.1 (3.6), and 11.6 (2.9) hours per day, respectively. Consonant-nucleus-consonant word scores 3 months after surgery in frail, prefrail, and not frail patients were 13% (12.2), 44% (19.7), and 51% (22.4), respectively. The median (range) number of missed follow-up visits (surgeon, audiologist, speech language pathologist combined) was 7 (1-10) in frail patients, compared with a median of 3 (0-4) and 2 (0-5) in prefrail and not frail patients. CONCLUSIONS: Frail patients did not have increased rates of surgical complications, need for vestibular rehabilitation, or postoperative falls. However, frail patients experienced challenges in accessing postoperative care, which may be addressed by using remote programming and rehabilitation.


Assuntos
Implante Coclear , Fragilidade , Humanos , Idoso , Fragilidade/complicações , Idoso Fragilizado , Avaliação Geriátrica , Estudos Prospectivos , Fenótipo
17.
Neurosurgery ; 91(4): 641-647, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-36001782

RESUMO

BACKGROUND: Previous studies comparing hearing outcomes in patients managed with stereotactic radiosurgery (SRS) and a watch-and-wait strategy were limited by small sample sizes that prevented controlling for potential confounders, including initial hearing status, tumor size, and age. OBJECTIVE: To compare hearing outcomes for patients with vestibular schwannomas (VS) managed with observation and SRS while controlling for confounders with propensity score matching. METHODS: Propensity score matching was used to compare 198 patients with unilateral VS with initial serviceable hearing (99 treated with SRS and 99 managed with observation alone) and 116 with initial class A hearing (58 managed with SRS and 58 with observation), matched by initial hearing status, tumor volume, age, and sex. Kaplan-Meier survival methods were used to compare risk of losing class A and serviceable hearing. RESULTS: Between patients with VS managed with SRS or observation alone, there was no significant difference in loss of class A hearing (median time 27.2 months, 95% CI 16.8-43.4, and 29.2 months, 95% CI 20.4-62.5, P = .88) or serviceable hearing (median time 37.7 months, 95% CI 25.7-58.4, and 48.8 months, 95% CI 38.4-86.3, P = .18). For SRS patients, increasing mean cochlear dose was not related to loss of class A hearing (hazard ratio 1.3, P = .17) but was associated with increasing risk of serviceable hearing loss (hazard ratio of 1.5 per increase in Gy, P = .017). CONCLUSION: When controlling for potential confounders, there was no significant difference in loss of class A or serviceable hearing between patients managed with SRS or with observation alone.


Assuntos
Perda Auditiva , Neuroma Acústico , Radiocirurgia , Seguimentos , Audição , Perda Auditiva/cirurgia , Testes Auditivos , Humanos , Neuroma Acústico/complicações , Neuroma Acústico/radioterapia , Neuroma Acústico/cirurgia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Estudos Retrospectivos , Resultado do Tratamento
18.
J Neurosurg ; 136(3): 768-775, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34416729

RESUMO

OBJECTIVE: In this study, the authors aimed to clarify the relationship between hearing loss and tumor volumetric growth rates in patients with untreated vestibular schwannoma (VS). METHODS: Records of 128 treatment-naive patients diagnosed with unilateral VS between 2012 and 2018 with serial audiometric assessment and MRI were reviewed. Tumor growth rates were determined from initial and final tumor volumes, with a median follow-up of 24.3 months (IQR 8.5-48.8 months). Hearing changes were based on pure tone averages, speech discrimination scores, and American Academy of Otolaryngology-Head and Neck Surgery hearing class. Primary outcomes were the loss of class A hearing and loss of serviceable hearing, estimated using the Kaplan-Meier method and with associations estimated from Cox proportional hazards models and reported as hazard ratios. RESULTS: Larger initial tumor size was associated with an increased risk of losing class A (HR 1.5 for a 1-cm3 increase; p = 0.047) and serviceable (HR 1.3; p < 0.001) hearing. Additionally, increasing volumetric tumor growth rate was associated with elevated risk of loss of class A hearing (HR 1.2 for increase of 100% per year; p = 0.031) and serviceable hearing (HR 1.2; p = 0.014). Hazard ratios increased linearly with increasing growth rates, without any evident threshold growth rate that resulted in a large, sudden increased risk of hearing loss. CONCLUSIONS: Larger initial tumor size and faster tumor growth rates were associated with an elevated risk of loss of class A and serviceable hearing.


Assuntos
Perda Auditiva , Neuroma Acústico , Radiocirurgia , Audição , Perda Auditiva/etiologia , Perda Auditiva/cirurgia , Testes Auditivos/efeitos adversos , Humanos , Neuroma Acústico/complicações , Neuroma Acústico/diagnóstico por imagem , Neuroma Acústico/patologia , Modelos de Riscos Proporcionais , Radiocirurgia/métodos , Estudos Retrospectivos , Resultado do Tratamento
19.
Otolaryngol Head Neck Surg ; 166(5): 957-963, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34488519

RESUMO

OBJECTIVE: To evaluate outcomes following salvage microsurgery (MS) and salvage stereotactic radiosurgery (SRS) after failure of primary treatment for vestibular schwannomas (VS). STUDY DESIGN: Retrospective chart review. SETTING: Tertiary referral center. METHODS: Patients with more than 1 intervention for their VS were divided into 4 groups: MS followed by SRS (n = 61), MS followed by MS (n = 9), SRS followed by MS (n = 7), and SRS followed by SRS (n = 7), and outcomes were evaluated. RESULTS: A total of 77 patients were included (84 procedures). In group 1 (MS then SRS), 3% developed a decline in facial function, 3% developed trigeminal sensory loss, and 13% patients had gradual improvement of facial nerve function following SRS. Group 2 (MS then MS) had the highest rates of facial nerve deterioration, although all but 1 patient achieved a House-Brackmann score of II or III. Gross-total resection (GTR) was achieved in 56% of patients. When a different approach was used for salvage resection, GTR occurred more commonly, and facial nerve outcomes were similar. In group 3 (SRS then MS), GTR occurred in 43% of cases, and 2 of 7 patients developed worsened facial function. In group 4 (SRS then SRS), no patient developed facial weakness after reirradiation, and 1 developed a trigeminal nerve deficit. CONCLUSIONS: For MS recurrences/residuals, SRS is the mainstay of treatment and does not preclude facial function recovery. If salvage microsurgery is required, an alternate approach should be considered. For SRS failures, when MS is required, less-than GTR may be preferable, and reirradiation is a potential safe alternative.


Assuntos
Neuroma Acústico , Radiocirurgia , Seguimentos , Humanos , Neuroma Acústico/radioterapia , Neuroma Acústico/cirurgia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Estudos Retrospectivos , Terapia de Salvação , Resultado do Tratamento
20.
Otol Neurotol ; 43(5): e578-e581, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35283466

RESUMO

OBJECTIVE: To investigate a new surgical and signal processing technique that provides apical stimulation of the cochlea using a cochlear implant without extending the length of the electrode array. PATIENTS: Three adult patients who underwent cochlear implantation using this new technique. INTERVENTIONS: The patients received a cochlear implant. The surgery differed from the standard approach in that a ground electrode was placed in the cochlear helicotrema via an apical cochleostomy rather than in its typical location underneath the temporalis muscle. Clinical fitting was modified such that low frequencies were represented using the apically placed electrode as a ground. MAIN OUTCOME MEASURES: Pitch scaling and speech recognition. RESULTS: All surgeries were successful with no complications. Pitch scaling demonstrated that use of the apically placed electrode as a ground lowered the perceived pitch of electric stimulation relative to monopolar stimulation. Speech understanding was improved compared with preoperative scores. CONCLUSIONS: The new surgical approach and clinical fitting are feasible. A lower pitch is perceived when using the apically placed electrode as a ground relative to stimulation using an extracochlear ground (i.e., monopolar mode), suggesting that stimulation can be provided more apically without the use of a longer electrode array. Further work is required to determine potential improvements in outcomes and optimal signal processing for the new approach.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Adulto , Cóclea/fisiologia , Cóclea/cirurgia , Implante Coclear/métodos , Surdez/cirurgia , Estimulação Elétrica , Eletrodos , Humanos , Percepção da Altura Sonora
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA