1.
J Appl Clin Med Phys ; 12(1): 3479, 2010 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-21330992

RESUMO

The transfer of radiation therapy data among the various subsystems required for external beam treatments is subject to error. Hence, the establishment and management of a data transfer quality assurance program is strongly recommended. It should cover the QA of data transfers of patient specific treatments, imaging data, manually handled data and historical treatment records. QA of the database state (logical consistency and information integrity) is also addressed to ensure that accurate data are transferred.


Assuntos
Bases de Dados Factuais , Radioterapia (Especialidade)/métodos , Radioterapia/métodos , Relatório de Pesquisa , Humanos , Imagens de Fantasmas , Controle de Qualidade , Radioterapia (Especialidade)/normas , Radioterapia/normas , Dosagem Radioterapêutica
2.
Pract Radiat Oncol ; 10(1): e45-e49, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31446148

RESUMO

Spine stereotactic body radiation therapy frequently involves the delivery of high doses to targets in proximity to the spinal cord; thus, the radiation must be delivered with great spatial accuracy. Monitoring for large shifts in target and cord position that might occur during dose delivery is a challenge for clinics equipped with a conventional C-arm Linac. Treatment must be halted, then imaging and registration must be done to determine whether a significant shift has occurred. In this retrospective study of 1019 spine SBRT treatments, we investigated the number of target shifts >2 mm in any direction that occurred in carefully immobilized patients. Orthogonal kV images were acquired 3 to 5 times during each session using in an in-room imaging system. Although the likelihood of large intrafractional shifts was found to be very low, they did occur in 6 treatment sessions. Intrafractional monitoring was found to be an important safety component of treatment delivery.


Assuntos
Lesões por Radiação/prevenção & controle , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias da Coluna Vertebral/radioterapia , Tomografia Computadorizada de Feixe Cônico , Fracionamento da Dose de Radiação , Humanos , Movimento , Órgãos em Risco/diagnóstico por imagem , Aceleradores de Partículas , Posicionamento do Paciente , Lesões por Radiação/etiologia , Radiocirurgia/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia de Intensidade Modulada/instrumentação , Estudos Retrospectivos , Medula Espinal/diagnóstico por imagem , Medula Espinal/efeitos da radiação , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Fluxo de Trabalho
3.
Phys Med Biol ; 62(8): 2961-2975, 2017 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-27983520

RESUMO

To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and a dual echo 3D mDIXON fast field echo (FFE) sequence for generating syn-CT. A dual-echo 3D FFE B 0 map was used for patient-induced susceptibility distortion analysis and a new 3D balanced-FFE sequence was evaluated for identification of implanted gold fiducial markers and subsequent image-guidance during radiotherapy delivery. Tissues were classified as air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned bulk HU values. The accuracy of syn-CT for treatment planning was analyzed by transferring the structures and plan from planning CT to syn-CT and recalculating the dose. Accuracy of localization at the treatment machine was evaluated by comparing registration of kV radiographs to either digitally reconstructed radiographs (DRRs) generated from syn-CT or traditional DRRs generated from the planning CT. Similarly, accuracy of setup using CBCT and syn-CT was compared to that using the planning CT. Finally, a MR-only simulation workflow was established and end-to-end testing was completed on five patients undergoing MR-only simulation. Dosimetric comparison between the original CT and syn-CT plans was within 0.5% on average for all structures. The de-novo optimized plans on the syn-CT met institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B 0 maps was within 1 mm and 0.5 mm in the body and prostate respectively. DRR and CBCT localization based on MR-localized fiducials showed a standard deviation of <1 mm. End-to-end testing and MR simulation workflow was successfully validated. MRI derived synthetic CT can be successfully used for a MR-only planning and treatment for prostate radiotherapy.


Assuntos
Marcadores Fiduciais , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Radioterapia Guiada por Imagem/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Osso e Ossos/diagnóstico por imagem , Humanos , Masculino , Neoplasias Pélvicas/radioterapia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Fluxo de Trabalho
4.
Radiat Oncol ; 12(1): 119, 2017 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-28716090

RESUMO

PURPOSE: To describe the details and experience of implementing a MR-only workflow in the clinic for simulation and planning of prostate cancer patients. METHODS: Forty-eight prostate cancer patients from June 2016 - Dec 2016 receiving external beam radiotherapy were scheduled to undergo MR-only simulation. MR images were acquired for contouring (T2w axial, coronal, sagittal), synthetic-CT generation (3D FFE-based) and fiducial identification (3D bFFE-based). The total acquisition time was 25 min. Syn-CT was generated at the console using commercial software called MRCAT. As part of acceptance testing of the MRCAT package, external laser positioning system QA (< 2 mm) and geometric fidelity QA (< 2 mm within 50 cm LR and 30 cm AP) were performed and baseline values were set. Our current combined CT + MR simulation process was modified to accommodate a MRCAT-based MR-only simulation workflow. An automated step-by-step process using a MIM™ workflow was created for contouring on the MR images. Patient setup for treatment was achieved by matching the MRCAT DRRs with the orthogonal KV radiographs based on either fiducial ROIs or bones. 3-D CBCTs were acquired and compared with the MR/syn-CT to assess the rectum and bladder filling compared to simulation conditions. RESULTS: Forty-two patients successfully underwent MR-only simulation and met all of our institutional dosimetric objectives that were developed based on a CT + MR-based workflow. The remaining six patients either had a hip prosthesis or their large body size fell outside of the geometric fidelity QA criteria and thus they were not candidates for MR-only simulation. A total time saving of ~15 min was achieved with MR-based simulation as compared to CT + MR-based simulation. An automated and organized MIM workflow made contouring on MR much easier, quicker and more accurate compared with combined CT + MR images because the temporal variations in normal structure was minimal. 2D and 3D treatment setup localization based on bones/fiducials using a MRCAT reference image was successfully achieved for all cases. CONCLUSIONS: MR-only simulation and planning with equivalent or superior target delineation, planning and treatment setup localization accuracy is feasible in a clinical setting. Future work will focus on implementing a robust 3D isotropic acquisition for contouring.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Fluxo de Trabalho , Humanos , Masculino
5.
Int J Radiat Oncol Biol Phys ; 82(5): 1744-8, 2012 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-21596489

RESUMO

PURPOSE: To report tumor local progression-free outcomes after treatment with single-dose, image-guided, intensity-modulated radiotherapy and hypofractionated regimens for extracranial metastases from renal cell primary tumors. PATIENTS AND METHODS: Between 2004 and 2010, 105 lesions from renal cell carcinoma were treated with either single-dose, image-guided, intensity-modulated radiotherapy to a prescription dose of 18-24 Gy (median, 24) or hypofractionation (three or five fractions) with a prescription dose of 20-30 Gy. The median follow-up was 12 months (range, 1-48). RESULTS: The overall 3-year actuarial local progression-free survival for all lesions was 44%. The 3-year local progression-free survival for those who received a high single-dose (24 Gy; n = 45), a low single-dose (<24 Gy; n = 14), or hypofractionation regimens (n = 46) was 88%, 21%, and 17%, respectively (high single dose vs. low single dose, p = .001; high single dose vs. hypofractionation, p < .001). Multivariate analysis revealed the following variables were significant predictors of improved local progression-free survival: 24 Gy dose compared with a lower dose (p = .009) and a single dose vs. hypofractionation (p = .008). CONCLUSION: High single-dose, image-guided, intensity-modulated radiotherapy is a noninvasive procedure resulting in high probability of local tumor control for metastatic renal cell cancer generally considered radioresistant according to the classic radiobiologic ranking.


Assuntos
Neoplasias Ósseas/radioterapia , Carcinoma de Células Renais/radioterapia , Neoplasias Renais , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Ósseas/mortalidade , Neoplasias Ósseas/secundário , Carcinoma de Células Renais/mortalidade , Carcinoma de Células Renais/secundário , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Análise Multivariada , Dosagem Radioterapêutica , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS