Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Enferm Infecc Microbiol Clin ; 34 Suppl 3: 1-7, 2016 Jul.
Artigo em Espanhol | MEDLINE | ID: mdl-27474240

RESUMO

The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology and molecular microbiology. This article presents the most relevant conclusions and lessons from the 2014 controls. As a whole, the results obtained in 2014 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of the SEIMC program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests.


Assuntos
Doenças Transmissíveis/diagnóstico , Laboratórios/normas , Controle de Qualidade , Bacteriologia/normas , Micologia/normas , Padrões de Referência , Espanha , Virologia/normas
2.
Enferm Infecc Microbiol Clin ; 34 Suppl 3: 8-13, 2016 Jul.
Artigo em Espanhol | MEDLINE | ID: mdl-27474241

RESUMO

Human immunodeficiency virus type 1 (HIV-1), hepatitis B virus (HBV) and hepatitis C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarizes the results obtained from the 2014 SEIMC (Spanish Society of Infectious Diseases and Clinical Microbiology) External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of 5 standards were sent. One standard consisted in seronegative human plasma, while the remaining 4 contained plasma from 3 different viremic patients, in the range of 2-5 log10 copies/mL; 2 of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (30.8% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 95.8% of laboratories reporting results within the limits (Δ < 0.5 log10 copies/mL). The HBV and HCV program consisted of 2 standards with different viral load contents. Most of the participants, 83.7% in the case of HCV and 87.9% in the HBV, obtained all the results within the accepted range (mean ± 1.96 standard deviations log10 IU/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up.


Assuntos
HIV-1 , Hepacivirus , Vírus da Hepatite B , Laboratórios/normas , Controle de Qualidade , Carga Viral/normas , Humanos , Espanha
3.
Med Oral Patol Oral Cir Bucal ; 21(2): e157-60, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26827058

RESUMO

BACKGROUND: To analyze the presence of salivary Epstein-Barr virus (EBV) DNA in oral squamous cell carcinoma and potentially malignant oral disorders. MATERIAL AND METHODS: Three groups were studied: Group 1 (12 oral squamous cell carcinomas (OSCC)), Group 2 (12 potentially malignant oral disorders (PMD)) and Group 3 (47 healthy controls). EBV DNA salivary analysis was performed by PCR. RESULTS: The highest percentage of positive salivary EBV DNA corresponded to the OSCC group (58.3%), followed by the PMD group (41.7%) and the controls (40.4%). The differences between groups were not statistically significant, however (p>0.05). CONCLUSIONS: Salivary EBV DNA was more prevalent in OSCC than in PMD or the controls.


Assuntos
Carcinoma de Células Escamosas/virologia , Herpesvirus Humano 4/isolamento & purificação , Doenças da Boca/virologia , Neoplasias Bucais/virologia , Saliva/virologia , Adulto , Idoso , Idoso de 80 Anos ou mais , DNA Viral/análise , Feminino , Herpesvirus Humano 4/genética , Humanos , Masculino , Pessoa de Meia-Idade , Saliva/química , Adulto Jovem
4.
Enferm Infecc Microbiol Clin ; 33 Suppl 2: 1-8, 2015 Jul.
Artigo em Espanhol | MEDLINE | ID: mdl-26320989

RESUMO

The External Quality Control Program of the Spanish Society of Infectious Diseases and Clinical Microbiology (SEIMC) include controls for bacteriology, serology, mycology, parasitology, mycobacteria, virology, molecular microbiology and HIV-1, HCV and HBV viral loads. This manuscript presents the analysis of results obtained of the participants from the 2013 SEIMC External Quality Control Programme, except viral loads controls, that they are summarized in a manuscript abroad. As a whole, the results obtained in 2013 confirm the excellent skill and good technical standards found in previous editions. However, erroneous results can be obtained in any laboratory and in clinically relevant determinations. Once again, the results of this program highlighted the need to implement both internal and external controls in order to assure the maximal quality of the microbiological tests.


Assuntos
Ensaio de Proficiência Laboratorial , Técnicas Microbiológicas/normas , Parasitologia/métodos , Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Adulto , Erros de Diagnóstico , Feminino , Humanos , Infectologia/organização & administração , Ensaio de Proficiência Laboratorial/organização & administração , Ensaio de Proficiência Laboratorial/normas , Ensaio de Proficiência Laboratorial/estatística & dados numéricos , Masculino , Microbiologia/organização & administração , Pessoa de Meia-Idade , Padrões de Referência , Sociedades Médicas , Espanha
5.
Enferm Infecc Microbiol Clin ; 33 Suppl 2: 9-14, 2015 Jul.
Artigo em Espanhol | MEDLINE | ID: mdl-26320990

RESUMO

Human immunodeficiency virus type 1 (HIV-1) and hepatitis B (HBV) and C virus (HCV) viral load determinations are among the most relevant markers for the follow up of patients infected with these viruses. External quality control tools are crucial to ensure the accuracy of results obtained by microbiology laboratories. This article summarized the results obtained from the 2013 SEIMC External Quality Control Programme for HIV-1, HCV, and HBV viral loads. In the HIV-1 program, a total of five standards were sent. One standard consisted in seronegative human plasma, while the remaining four contained plasma from three different viremic patients, in the range of 2-5 log10 copies/mL; two of these standards were identical aiming to determine repeatability. A significant proportion of the laboratories (25% on average) obtained values out of the accepted range (mean ± 0.25 log10 copies/mL), depending on the standard and on the method used for quantification. Repeatability was excellent, with up to 98.9% of laboratories reporting results within the limits (D < 0.5 log10 copies/mL). The HBV and HCV program consisted of two standards with different viral load contents. Most of the participants, 82% in the case of HCV and 78% in the HBV, obtained all the results within the accepted range (mean ± 1.96 SD log10 UI/mL). Data from this analysis reinforce the utility of proficiency programmes to ensure the quality of the results obtained by a particular laboratory, as well as the importance of the post-analytical phase on the overall quality. Due to the remarkable interlaboratory variability, it is advisable to use the same method and the same laboratory for patient follow up.


Assuntos
Infecções por HIV/sangue , HIV-1/isolamento & purificação , Hepacivirus/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Hepatite B/sangue , Hepatite C/sangue , Ensaio de Proficiência Laboratorial , Carga Viral , Viremia/virologia , Infecções por HIV/virologia , Hepatite B/virologia , Hepatite C/virologia , Humanos , Infectologia/organização & administração , Ensaio de Proficiência Laboratorial/normas , Microbiologia/organização & administração , Padrões de Referência , Reprodutibilidade dos Testes , Sociedades Médicas/normas , Espanha
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA